Installation and Operation Guide P/N Rev 04

Similar documents
Disk and OE Matrix. EMC VNXe 3200 Series Storage Systems. VNXe 3200 series storage systems

Disk and OE Matrix. EMC VNXe Series. Storage Systems

Disk and OE Matrix. EMC VNXe Series Storage Systems. VNXe series storage systems

Best Practices Guide. EMC VMAX3 Family. Best Practices Guide for AC Power Connections REVISION 2.0. August, 2015

Disk and OE Matrix. EMC VNX5100 and VNX5300 Series Storage Systems P/N

Disk and FLARE OE Matrix PN

Parts Location Guide P/N Rev 01

Disk and FLARE OE Matrix P/N REV A17 February 22, 2011

Dell SC460 Expansion Enclosure Getting Started Guide

Drive and FLARE OE Matrix

Customer Replacement Procedure

Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid

EMC VNXe. Replacing a link control card in a 12-slot disk-array enclosure REV 02. July, 2015

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

Replacing a 3.5-inch disk drive

Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems

TRC-190 User s Manual

EMC VNX5100 AND VNX5300 BLOCK STORAGE

VNXe1600 BLOCK STORAGE SYSTEM

Dell Storage MD1400 and MD1420 Enclosures Getting Started Guide

EMC VMAX Best Practices Guide for AC Power Connections

Installing and Configuring Rialto Analytic Appliances

EMC VNXe. Adding input/output modules to a disk processor enclosure REV 03. July, 2015

Dell SC7020 Storage Controller Getting Started Guide

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Dell EMC Unity Family Dell EMC Unity All Flash, Unity Hybrid, UnityVSA. Unity shut down and restart the system (power down and power up)

Customer Replacement Procedure

Open Processor with Square D Driver

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Release Notes P/N Rev A01

High Power over Ethernet Midspans PD Port Model PD Port Model

EMC1600 Series Media Converter and Ethernet Extender Chassis

Power Supply and Fan Module Installation

Customer Replacement Procedure

RPX Series USER S MANUAL

Power Supply Installation

Digital ac/dc (24V) Input Module

EMC Symmetrix VMAX Cloud Edition

EMSwitch RF Switch Plug-In Card

Power Supply and Fan Module Installation

FP-PS-4. Features. Installation

TRC-190 User s Manual

Customer Upgrade Procedure

EMC CLARiiON CX3 Series FCP

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

EMC Celerra NS-120 System (Single Blade) Installation Guide

DIN Rail. user manual Models , & INT /503556/ UM

Multi-Channel RS-232 Current Loop Interface Converter (CLIC)

EMC VNXe SERIES UNIFIED STORAGE SYSTEMS

TECHNICAL SPECIFICATION. Brocade 6510 Switch Technical Specifications

Customer Replacement Procedure

EMC Celerra NS-120 System (Dual Blade) Installation Guide

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Customer Replacement Procedure

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Brocade ICX 6610 Switch

First of all, thank you for purchasing R2W series redundant power supply.

Technical Manual SMART TRAC PS Card

VCE Vblock Specialized Systems for Extreme Applications. Gen 2.1 Physical Planning Guide

2201 Rack Chassis User Manual

A.G.P. Pro Specification

Customer Upgrade Procedure

Installation Instructions

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Release Notes P/N REV A01 February 23, 2006

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

170 ADI VDC - 16 Pt. Discrete Input Module Base

Prisma II Platform. Optoelectronics

AT-8900, AT-9900, AT-9900s Switches Removable Power Supply and Fan Installation Guide

Installation AC Power Supply

Installation and Maintenance

PRODUCT DESCRIPTION. Vertically cooled 2RU rectifiers with wide range of output modules available.

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Power Supply (48Vdc, 2.5A)

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

Customer Replacement Procedure

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

CPX8216 Series CompactPCI High Availability System

smar Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Installation Instructions

EMC VNXe3200 UNIFIED STORAGE SYSTEM

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Customer Replacement Procedure

Reference Architecture

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Installation Instructions

PACSystems* RX3i IC695PSA040

Dell MD1280 Storage Enclosure Getting Started Guide

Ink-Dot Series II Driver

FLEX Ex Spring Clamp Terminal Base

DNS-2608 Enterprise JBOD Enclosure User Manual

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

C5C Cross-Connect System

Transcription:

EMC DC-Powered VNXe Enclosures Installation and Operation Guide P/N 300-012-582 Rev 04 September 24, 2015 This document describes the few exceptions in which DC-powered VNXe1600, VNXe3200, and VNXe3300 series systems differ from their AC counterparts. Topics include: Power considerations... 2 Cabling DC power and powering the system up and down... 5 In general, you configure, operate, and maintain DC-powered systems as you would the more common AC systems. DC in the 15-slot and 25-slot disk processor enclosures (DPE) and 15-slot disk-array enclosures (DAE6S) include power on/off switches or buttons. The DC in the 25-slot disk-array enclosures (DAE5S) do not include power on/off switches or buttons. For the most up-to-date and complete set of VNXe series documentation, visit the support site at emc.com/vnxesupport. IMPORTANT Systems with DC power are intended for use in environments with redundant and highly available power sources (for example, "Central Office" grade power within the telecommunications industry), and DC power provided by the site must meet this requirement. The sudden loss of all incoming DC power to a storage system may cause unexpected abnormal behavior of the storage system and loss of write-cache data.

Power considerations Power considerations Power distribution must support the number of outlets required for the device (two per enclosure) and the device power rating. Table 1 lists the power specifications for EMC VNXe1600 series disk processor and supported DC disk-array enclosures. Table 1 Disk processor/array enclosure (VNXe1600, DAE5S), DC ratings Description (note all ratings assume fully configured systems) Requirement DC line voltage VNXe1600 12-slot DPE VNXe1600 25-slot DPE DAE5S -39 to -72 V DC (nominal -48 V or -60 V power systems) DC line current (operating 10.1 A max at -39 V DC 8.4A max at -48 V DC 5.7A max at -72 V DC 12.3 A max at -39 V DC 10.2 A max at -48 V DC 6.9 A max at -72 V DC 7.56 A max at -36 V DC 5.67 A max at -48 V DC 3.78 A max at -72 V DC Power consumption (operating 392 W max at 39 V DC 402 W max at 48 V DC 413 W max at 72 V DC 480 W max at 39 V DC 488 W max at 48 V DC 498 W max at 72 V DC 272 W max Heat dissipation (operating 1.41 x 10 6 J/hr, (1,338 Btu/hr) max @ -39 V DC 1.45 x 10 6 J/hr, (1,372 Btu/hr) max @ -48 V DC 1.49 x 10 6 J/hr, (1,409 Btu/hr) max @ -72 V DC 1.73 x 10 6 J/hr, (1638 Btu/hr) max @ -39 V DC 1.76 x 10 6 J/hr, (1,665 Btu/hr) max @ -48 V DC 1.79 x 10 6 J/hr, (1,699 Btu/hr) max @ -72 V DC.979 x 10 6 J/hr (928.1 Btu/hr) max In-rush current DC protection 40 A fuse in each power 40 A fuse in each power 20 A fuse in each power DC inlet type PLB3W3M1000 Mating DC connector PLB3W3F7100A1 Ride-through time 1 ms min at -50V input 1 ms min at -50V input 5 ms min at -40 V input Current sharing ± 5% of full load, between ± 10% of full load, between ±15% of full load, between 2 VNXe Series Hardware in NEBS-Compliant Environments Installation Guidelines

Power considerations Table 2 lists the power specifications for EMC VNXe3200 series disk processor and supported DC disk-array enclosures. Table 2 Disk processor/array enclosure (VNXe3200, DAE5S), DC ratings Description (note all ratings assume fully configured systems) Requirement DC line voltage VNXe3200 15-slot DPE VNXe3200 25-slot DPE DAE5S -36 to -72 V DC (nominal -48 V or -60 V power systems) DC line current (operating 12.56 A max at -36 V DC 9.42 A max at -48 V DC 6.28 A max at -72 V DC 11.78 A max at -36 V DC 8.83 A max at -48 V DC 5.89 A max at -72 V DC 7.56 A max at -36 V DC 5.67 A max at -48 V DC 3.78 A max at -72 V DC Power consumption (operating 452 W max 424 W max 272 W max Heat dissipation (operating 1.63 x 10 6 J/hr, (1,542 Btu/hr) max 1.53 x 10 6 J/hr, (1,447 Btu/hr) max.979 x 10 6 J/hr (928.1 Btu/hr) max In-rush current 20 A peak per requirements in DC protection 50 A fuse in each power 50 A fuse in each power 20 A fuse in each power DC inlet type PLB3W3M1000 Mating DC connector PLB3W3F7100A1 Ride-through time 1 ms min at -50V input 1 ms min at -50V input 5 ms min at -40 V input Current sharing ± 10% of full load, between ± 10% of full load, between ±15% of full load, between VNXe Series Hardware in NEBS-Compliant Environments Installation Guidelines 3

Power considerations Table 3 lists the power specifications for EMC VNXe3300 series disk processor and supported DC disk-array enclosures. Table 3 Disk processor/array enclosure (VNXe3300, DAE6S, DAE5S), DC ratings Description (note all ratings assume fully configured systems) Requirement DC line voltage VNXe3300 15-slot DPE VNXe3300 25-slot DPE DAE6S DAE5S -36 to -72 V DC (nominal -48 V or -60 V power systems) DC line current (operating 12.6 A max at -36 V DC 9.5 A max at -48 V DC 12.5 A max at -36 V DC 9.4 A max at -48 V DC 7.86 A max at -36 V DC 5.90 A max at -48 V DC 3.93 A max at -72 V DC 7.56 A max at -36 V DC 5.67 A max at -48 V DC 3.78 A max at -72 V DC Power consumption (operating 455 W max 450 W max 283 W max 272 W max Heat dissipation (operating 1.64 x 10 6 J/hr (1,560 Btu/hr) max 1.64 x 10 6 J/hr (1,540 Btu/hr) max 1.02 x 10 6 J/hr (965.6 Btu/hr) max.979 x 10 6 J/hr (928.1 Btu/hr) max In-rush current 35 A peak 35 A peak 20 A peak 20 A peak per requirements in DC protection 30 A fuse in each power 30 A fuse in each power 20 A fuse in each power 20 A fuse in each power DC inlet type PLB3W3M1000 PLB3W3M1000 Mating DC connector PLB3W3F7100A1 PLB3W3F7100A1 Ride-through time 10 ms min at -50 V input 10 ms min at -50 V input 5 ms min at -40 V input 5 ms min at -40 V input Current sharing ±10% of full load, between ±10% of full load, between ±15% of full load, between power supplies ±15% of full load, between power supplies 4 VNXe Series Hardware in NEBS-Compliant Environments Installation Guidelines

Cabling DC power and powering the system up and down Power cords Figure 1 shows a typical power cord provided by EMC. Table 4 describes the pin outs. Figure 1 VNXe DC power cable cord Table 4 Cabling pinout P1 designation Description Wire color 1 DC positive (+) Black 2 DC negative (-) Brown 3 Chassis ground Green/Yellow Cabling DC power and powering the system up and down After installing the storage-system hardware, cable DC power and power up the system components. Note: VNXe DPEs and DAEs start immediately when connected to active DC input; you do not need to press or toggle the power switches. Connect each power to a DC power source. See Figure 2 on page 6. For high availability, be sure to connect the A and B power cords in each enclosure to different power source feed circuits. VNXe Series Hardware in NEBS-Compliant Environments Installation Guidelines 5

- + - + Cabling DC power and powering the system up and down + - + - CL4809 Figure 2 DC power cord connection Note: Grounding screws on the provide additional grounding sources, if necessary. Powering down a DC-powered VNXe series system Follow these instructions to power down VNXe series storage systems with DC power: 1. Stop all I/O activity to the storage system. Note: Stopping the I/O allows the SP to destage cache data, and may take some time. The length of time will be based on criteria such as the amount of cache, the amount of data in the cache, the type of data in the cache, and the target location on the disks, but it is typically less than one minute. 2. If the server connected to the storage system is running the UNIX operating system, unmount the file systems. 3. On the disk processor enclosure, push the power button on each power and hold the button in for two seconds. Refer to Figure 3 on page 7. 6 VNXe Series Hardware in NEBS-Compliant Environments Installation Guidelines

Cabling DC power and powering the system up and down DAE6S power switch (2) DPE power button (2) CL4796 Figure 3 DC power switches Note: Allow the power to complete its shutdown sequence before removing the power source. An orderly shutdown that flushes all cache can take up to several seconds before the host sends a STOP to the power. We recommend that you wait two minutes before removing a power from the DPE chassis. 4. Power down power strips A and B. Note: If you need to retain power to other systems in a rack/cabinet, leave the power strips powered up. If necessary, toggle the DAE6S power switches to the off position; remove power cords from the DAE5S enclosures. Copyright 2015 EMC Corporation. All rights reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS IS. EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date regulatory document for your product line, go to the Technical Documentation and Advisories section on EMC Powerlink. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. All other trademarks used herein are the property of their respective owners. VNXe Series Hardware in NEBS-Compliant Environments Installation Guidelines 7