The dual display means that the current value and the threshold value, it makes direct setting of threshold value

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure

Head-separated Dual Display Digital Pressure Sensor DPC-100 SERIES DPH-100 SERIES

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

One step ahead in performance and mounting ease

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Dual 3-color display makes operation easier!

Head-separated Digital Pressure Sensor For Gas DP5 SERIES DPH SERIES. High speed response of 1/1,000 sec. High speed response 1 ms

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

Suitable for detecting transparent films or transparent bottles

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

No. 1. The World s in Compactness. Amplifier Built-in Ultra-minute Photoelectric Sensor EX-Z SERIES panasonic.net/id/pidsx/global

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

The World s in Compactness. * Among photoelectric sensors with built-in amplifier, as of June 2015 (survey by our company)

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

Compact Inductive Proximity Sensor

NA1-5. Ultra-slim Body 25mm Beam Pitch Area Sensor. Even a Slim Hand Is Detected by the 25mm Pitch Beam Curtain AREA SENSORS.

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

SERIES. FX-311 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology.

SERIES Amplifier Built-in Miniature-size Photoelectric Sensor

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

Optimum sensing capability for LCD manufacturing

Low Price Rectangular-shaped Inductive Proximity Sensor. The GL-N12 series is recommended to large volume users for cost reduction.

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

The GL-N12 series is recommended to large volume users for cost reduction. Exclusive mounting bracket. Cost saving. Conventional model.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Convergent Reflective Micro Photoelectric Sensor

DC 2-wire Cylindrical Inductive Proximity Sensor

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

EX-30SERIES. Threaded Miniature Photoelectric Sensor. The next-generation New Form series. A new alternative to fiber sensors. M4(Reflective type: M6)

U-shaped Type/Convergent Reflective Type. onlinecomponents.com

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Even a specular background does not affect the sensing performance if the sensor is located 30mm away from it (when directly opposite).

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

GP-X SERIES Conforming to EMC Directive

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

Color Detection Fiber Sensor FZ-10 SERIES. Reliable and precise color discrimination. Red, green and blue LEDs. Easy set up

The GL-N12 series is recommended to large volume users for cost reduction. Exclusive mounting bracket. Cost saving. Conventional model

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection. Hardly affected by background

Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES. Ultra-compact sensor head A high-functionality intelligent controller

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

panasonic.net/id/pidsx/global Up to 16 I/O devices can be connected at once using MIL connectors

NPN open-collector transistor (Judgment output) Current / voltage output (Linear output)

Capable of diagnosing own state and reporting to the host device

LCD Readout Digital Pressure Switch

High Accuracy Eddy Current Type Displacement Sensor. Linearity 0.5 % F.S.

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES. Ultra-compact sensor head A high-functionality intelligent controller

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

Inductive Proximity Sensor

ISE5B. Series ZSE5B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Long sensing range of 500 mm in (HL-T1005A, HL-T1010A) and 2 m ft (HL-T1001A) are available. Adoption of a Class 1 laser

Mini Photoelectric Sensor

A line width of approx. 240 mm in (typical) at a 1,000 mm in sensing distance

Series Pressure Sensor Instruction Sheet

Laser Collimated Beam Sensor

LS-500 SERIES. Digital Laser Sensor Amplifier-separated. Industry s smallest* Industry s smallest* + Stainless steel (SUS) enclosure

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Thread length (overall length) material

Precise sensing in wide area. Sensing area: mm in Minimum sensing object: "0.1 mm "0.004 in Repeatability: 10!m 0.

Series Pressure Sensor Instruction Sheet

Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES. Ultra-compact sensor head A high-functionality intelligent controller

SERIES. Ultra-compact Photoelectric Sensor. Long sensing range

Amplifi er-separated. A line width of approx. 240 mm in (typical) at a 1,000 mm in sensing distance

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Long sensing range. 2 m ft. Retroreflective type. 200 mm in. Diffuse reflective type. 160 mm in

BGS (at min. setting) BGS (at max. setting)

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

LS-500 SERIES. Digital Laser Sensor Amplifier-separated. Industry s smallest* Industry s smallest* + Stainless steel (SUS) enclosure

Cylindrical Proximity Sensor

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm

Type Pressure range description Part number

Superb craftsmanship!

PRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

DIGITAL LASER SENSOR. User friendly, high precision Digital Laser Sensor SERIES mm in. Easy 1 Installation.

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

187 HG-C SERIES panasonic.net/id/pidsx/global Reliable detection in repeatability 10 μm mil Overwhelmingly stable

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

Slim Body Analog Fiber Sensor. Analog output type for diverse applications. Slim size. Analog voltage output. Various uses. Saturation indicator

The World s Smallest TOF Sensor lineup with analog output type

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Transcription:

73 PHOTO PHOTO Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions... P.1566 MEASURE Simple & easy operation panasonic.net/id/pidsx/global Simple and easy operation Redesigned for improvement of pressure sensor usability from ground up Two levels of configuration for easy operation of essential functions The RUN mode is for setting the threshold value, the zero point adjustment and key lock/release setting, and the detailed configuration allows the basic settings of sensor operation. The two-level configuration enables an easy and immediate use of the product. Digital Detailed configuration Main menu for detailed configuration Pressure unit setting mode Operation setting mode* NO/NC setting mode RUN mode Threshold value setting Zero point adjustment Key lock setting / release Operation setting mode NO/NC setting mode Response time setting mode Display color setting mode Settings initializing mode Select from EASY mode, hysteresis mode or window comparator mode. Response time setting mode Select the response time from 2.5 ms, 25 ms or 25 ms. Set the comparative output operation to NO or NC. Display color setting mode Select the comparative output ON/ OFF display color and the normal display color from red or white. * Refer to p.75 for details of operation setting mode. Functional design Black body for enhanced visibility of LCD display The unit body is completely black to make the LCD display easier to see. Firm and crisp clicking feel The buttons offer firm and crisp clicking feel for smooth and reliable setting operations. Crisp clicking feel

Digital Pressure Sensor SERIES 74 APPLICATIONS Suction confirmation for electronic parts Reference pressure check High-quality LCD display Simple and highly visible display The LCD offers a wide viewing angle so the display is easy to see even from an oblique angle. The alphanumeric display (12-segment display), the key lock mark and the OVER mark are also clear and easy to see. Comparative output ON/OFF display Key lock icon OVER mark setting display Pressure unit display Low pressure type: kpa, kgf/cm 2, bar, psi, mmhg High pressure type: MPa, kgf/cm 2, bar, psi of display color from red or white The display color can be selected from red or white in accordance with the output operation. Since the detailed setting mode display is pink (unchangeable), the pressure sensor status can be easily recognized by color. Mode RUN mode Display color setting Comparative output ON Comparative output OFF Red for ON, white for OFF Red White White for ON, red for OFF White Red Red in normal status White in normal status RUN mode Red White Detailed mode Pink Detailed setting mode PHOTO PHOTO MEASURE Compact & light weight design Extra-short depth and light weight The unit body measures only 24.9 mm.98 in in depth to allow installation in a shallow space. The main unit weighs only about 25 g. The lightweight unit means minimal load when mounted on a moving part such as a robot arm. Comparison with Depth conventional model dimension : Approx. 41% shorter! series standard Main unit ( pressure port type ) weight : Approx. 38% lighter! series Approx. 25 g 24.9 mm.98 in < Actual size > Conventional model ( series standard pressure port type) Approx. 4 g 42.5 mm 1.673 in Low pressure type and high pressure type available Two types to choose from depending on your application The low pressure type can be used with positive or negative pressure, while the high pressure type is suitable for positive pressure of up to 1 MPa. 1 kpa kpa Low 1 pressure type High pressure type <Low pressure type> Ideal for applications such as suction. No mis-operations occur due to vacuum breakdown. 1 kpa <High pressure type> Ideal for applications such as checking reference pressure. Can also be used for simple suction. 2 1 MPa

75 Digital Pressure Sensor SERIES PHOTO PHOTO MEASURE Three output modes Equipped with three output modes for use in a wide range of applications Pressure P-1 Comparative ON output OFF (1) EASY mode This mode is used for comparative output ON/ OFF control. Designed for easy installation Panel mounting bracket H (Hysteresis) Pressure P-2 P-1 Comparative ON output OFF (2) Hysteresis mode This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON/OFF control. H (Hysteresis) (3) Window comparator mode This mode is used for setting comparative output ON and OFF at pressures within the setting range. P-2 P-1 Comparative ON output OFF H (Hysteresis) H (Hysteresis) *H: 4 digits (fixed) (1 digits or more when using psi unit) *H: 2 digits or more (5 digits or more when using psi unit) *H: 4 digits or more (1 digits or more when using psi unit) Tight installation is possible An exclusive mounting bracket that is suitable for 1 to 3 mm.39 to.118 in panel thickness is available. Panel mounting bracket MS-DP1-8 Neat and space saving Pressure Front protection cover MS-DP1-3 Tight installation is possible Exclusive mounting bracket Supports tight installation Space savings can also be achieved even when an L-shaped mounting bracket is used. Tight installation is possible Connection cable A single mounting hole Cable can be connected with one-touch Connector attached cable (2 m 6.562 ft), as an accessory, can be connected easily with one-touch connection. Positioning bosses for easier mounting bracket installation Connection cable * * Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.44 ft types are also available. Ceiling mounting MS-DP1-1 Floor mounting M3 (length 6 mm.236 in) screws with washers (Accessory for MS-DP1-1) Types without connector attached cable are also available -J Commercially-available connectors can be used for cable connections. Cables in required length can be used, so this contributes to reduction in waste of unwanted cables. MS-DP1-5 M3 (length 6 mm.236 in) screws with washers (Accessory for MS-DP1-5) Environmentally friendly Commercially-available parts can be used! Rear mounting * Refer to p.76 for recommended commercially-available connectors.

Digital Pressure Sensor SERIES 76 ORDER GUIDE Model No. 1 - P - J Rated pressure range 1 : 1. to +1. kpa (Low pressure type) 2 :. to +1. MPa (High pressure type) Cable None : Connector attached cable 2 m 6.562 ft J : Type without connector attached cable Comparative output None : NPN output type P : PNP output type Type Appearance Rated pressure range Model No. Pressure port Comparative output Low pressure type High pressure type *CN-14A-C2 (Connector attached cable 2 m 6.562 ft ) is attached. Type without connector attached cable 1. to +1. kpa. to +1. MPa Type without connector attached cable CN-14A-C2 is available. When ordering this type, suffix -J to the Model No. (e.g.) Type without connector attached cable of 1-P is 1-P-J 1 1-P 2 2-P Accessory M5 female thread NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor CN-14A-C2 (Connector attached cable 2 m 6.562 ft) Designation Model No. Description CN-14A-C1 Length: 1 m 3.281 ft.2 mm 2 4-core cabtyre cable with Connector CN-14A-C2 (Note) Length: 2 m 6.562 ft connector on one end attached cable CN-14A-C3 Length: 3 m 9.843 ft Cable outer diameter: ø3.7 mm ø.146 in CN-14A-C5 Length: 5 m 16.44 ft CN-14A-R-C1 Length: 1 m 3.281 ft.2 mm 2 4-core bending-resistant Connector attached cable CN-14A-R-C2 Length: 2 m 6.562 ft cabtyre cable with connector on one end Bending-resistant CN-14A-R-C3 Length: 3 m 9.843 ft ( Cable outer diameter: ø3.7 mm cable ) ø.146 in CN-14A-R-C5 Length: 5 m 16.44 ft Connector CN-14A Set of 1 housings and 4 contacts Sensor mounting bracket Panel mounting bracket Front protection cover MS-DP1-1 MS-DP1-5 MS-DP1-8 MS-DP1-3 Allows sensors to be installed on the flooring or ceiling. Multiple sensors can also be mounted closely. Allows sensors to be installed on the wall. Multiple sensors can also be mounted closely. Allows installation to panels with thickness of 1 to 3 mm.39 to.118 in. Multiple sensors can also be mounted closely. Protects the adjustment surfaces of sensors. (Can be attached when using the panel mounting bracket) Conversion bushing MS-DP1-7 Pressure port can be converted to Rc 1 /8 female thread. Note: The connector attached cable CN-14A-C2 is supplied with the series. Recommended connector Contact: SPHD-1T-P.5, Housing: PAP-4V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Recommended crimping tool Model No.: YC-61R (Manufactured by J.S.T. Mfg. Co., Ltd.) Recommended connector (e-con) Applicable connector: 3714-3122- FL (Manufactured by 3M Japan Limited) Note: Contact the manufacturer for details of the recommended products.

77 Digital Pressure Sensor SERIES SPECIFICATIONS Model No. Type Low pressure High pressure NPN output 1 2 Item PNP output 1-P 2-P CE marking directive compliance Type of pressure EMC Directive, RoHS Directive Gauge pressure Rated pressure range 1. to +1. kpa. to +1. MPa Set pressure range 11. to +11. kpa 1.3 to +1.3 kgf/cm 2 1.1 to + 1.1 bar 14.65 to +14.65 psi 756 to +756 mmhg.1 to +1.1 MPa.1 to +1.3 kgf/cm 2.1 to + 1.1 bar.1 to +146.5 psi Pressure withstandability 5 kpa 1.5 MPa Applicable fluid Air, non-corrosive gas Selectable unit Low pressure type: kpa, kgf/cm 2, bar, psi, mmhg High pressure type: MPa, kgf/cm 2, bar, psi Supply voltage Power consumption Comparative output Output operation Hysteresis <NPN output type> NPN open-collector transistor Maximum sink current: 5 ma Applied voltage: 3 V DC or less (between comparative output and V) Residual voltage: 2 V or less (at 5 ma sink current) 12 to 24 V DC ±1 % Ripple P-P 1 % or less 3 ma or less Selectable either NO or NC by key operation Minimum 2 digits (variable) <PNP output type> PNP open-collector transistor Maximum source current: 5 ma Applied voltage: 3 V DC or less (between comparative output and +V) Residual voltage: 2 V or less (at 5 ma source current) Repeatability ±.2 % F.S. (within ±4 digits) ±.4 % F.S. (within ±4 digits) Response time 2.5 ms, 25 ms, 25 ms, selectable by key operation Display Environmental resistance Protection Short-circuit protection Displayable pressure range Incorporated 3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 25 ms) 11. to +11. kpa 1.3 to +1.3 kgf/cm 2 1.1 to + 1.1 bar 14.65 to +14.65 psi 756 to +756 mmhg IP4 (IEC).1 to +1.1 MPa.1 to +1.3 kgf/cm 2.1 to + 1.1 bar.1 to +146.5 psi Ambient temperature to +5 C +32 to +122 F (No dew condensation allowed), Storage: -1 to +6 C +14 to +14 F Ambient humidity Voltage withstandability Insulation resistance Vibration resistance Shock resistance 35 to 85 % RH, Storage: 35 to 85 % RH 5 V AC for one min. between all supply terminals connected together and enclosure 5 MΩ or more with 5 V DC megger between all supply terminals connected together and enclosure 1 to 15 Hz frequency, double amplitude.75 mm.3 in or maximum acceleration 49 m/s 2, in X, Y and Z directions for two hours each 1 m/s 2 acceleration (1 G approx.) in X, Y and Z directions three times each Pollution degree 2 Overvoltage category Usable altitude I 2, m 6,562 ft or less Temperature characteristics (+ C +68 F standard) Grounding method Pressure port Material Weight Accessory +1 to +4 C +5 to +14 F: Within ±1 % F.S. to +5 C +32 to +122 F: Within ±2.5 % F.S. Floating M5 female thread +1 to +4 C +5 to +14 F: Within ±2 % F.S. to +5 C +32 to +122 F: Within ±5 % F.S. Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Brass (nickel plated) Mounting threaded part: Brass, O-ring: Nitrile rubber (NBR), Key section: Polycarbonate 25 g approx. CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1 pc. Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of + C +68 F.

Digital Pressure Sensor SERIES 78 I/O CIRCUIT AND WIRING DIAGRAMS NPN output type I/O circuit diagram D1 Terminal No. Color code of connector attached cable (Brown) +V 1 Terminal arrangement diagram Sensor circuit 3 (White) Not connected (Note) Load D2 (Black) Comparative output 2 Tr 5 ma MAX. ZD (Blue) V 4 Internal circuit Users circuit Note: Open or, connect to V. + 12 to 24 V DC ±1 % Terminal No. 1 2 3 4 Designation +V Comparative output Symbols D1, D2: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: NPN output transistor Note: Open or, connect to V. Not connected (Note) V PNP output type I/O circuit diagram Sensor circuit D1 Tr ZD D2 Internal circuit Note: Open or, connect to V. Terminal No. Color code of connector attached cable (Brown) +V 1 5 ma MAX. 2 (Black) Comparative output 3 (White) Not connected (Note) Load (Blue) V 4 Users circuit Symbols D1, D2: Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr: PNP output transistor + 12 to 24 V DC ±1 % Terminal arrangement diagram Terminal No. 1 2 3 4 Note: Open or, connect to V. Designation +V Comparative output Not connected (Note) V

79 Digital Pressure Sensor SERIES PRECAUTIONS FOR PROPER Part description ON mark OFF mark Key lock mark OVER mark Mode selection key Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. This product is used for non-corrosive gas. The product shall not be used for liquid or corrosive gas. Never use fluids having inflammability, toxicity, etc., that affect the human body, either. Digital display unit Setting value UP key Setting value DOWN key Connecting connector Pressure port (M5 female thread) Piping When using this product, connect a joint available in the market to the pressure port. At the time, the tightening torque should be 1. N m or less. Mounting Use sensor mounting bracket MS DP1 1 prepared independently. When mounting this product with sensor mounting bracket, etc., the tightening torque should be.5 N m or less. Sensor mounting bracket MS-DP1-1 (Optional) M3 (length 6 mm.236 in) screws with washers (Accessory with MS-DP1-1) Panel mounting bracket MS DP1 8 (optional) and front protection cover MS DP1 3 (optional) are available. For the method for mounting panel mounting bracket, refer to the instruction manual that came with the MS DP1 8. Wiring Make sure that the power supply is OFF while performing the wiring operation. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. When extending the cable, use a cable whose conductor crosssection area is.3 mm 2 or more. The cable can be extended to up to 1 m 32.88 ft in total length. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Do not apply stress directly to the connection cable leader or to the connector. Connection How to connect Insert the cable with connector CN 14A( R) C into this product s connection connector section as shown in the right figure. How to disconnect Pressing the release lever of the cable with connector, pull out the connector. Note: Do not pull by holding the cable without pressing the release lever, as this can cause cable break or connector break. Factory setting Type Low pressure type High pressure type Operation setting EASY mode NO/NC setting NC NO Threshold value 5..5 Pressure unit kpa MPa Display color Response speed Error indication Red when ON, White when OFF 2.5 ms Error indication Description Remedy The load is short-circuited causing an overcurrent to flow. Pressure is applied during zero point adjustment. The applied pressure exceeds the upper limit of the displayed pressure range. The applied pressure exceeds the lower limit (back pressure) of the displayed pressure range. When other error massage is displayed, contact us. Refer to p.1566 for general precautions. Release lever Cable with connector CN-14A(-R)-C Turn OFF the power and check the load. Applied pressure at the pressure port should be brought to atmospheric pressure and zero-point adjustment should be done again. Applied pressure range should be brought within the rated pressure range. Others This product has been developed / produced for industrial use only. The product shall be used only within the rated pressure range. Do not apply pressure exceeding the pressure resistance. Otherwise, destruction of diaphragm occurs, preventing the product to perform normal operation. Do not use during the initial transient time (.5 sec.) after the power supply is switched ON. The specification may not be satisfied in a strong magnetic field. This product is suitable for indoor use only. Take care that strong impact such as fall is not given to this product. Otherwise, it may be destroyed. Avoid dust, dirt, and steam. Take care that the product does not come into contact with organic solvents such as thinner. Take care that the product does not come into contact with oil or grease. Take care that the product does not come into contact with strong acid or alkaline. Do not insert wire into the pressure port. Otherwise, destruction of diaphragm occurs, preventing the product to perform normal operation.

Digital Pressure Sensor SERIES 71 DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website. 3 1.181 Mode selection key 3 1.181 4.9.193 Display Setting value DOWN key Setting value UP key 24.9.98 1.3.51 ø8.35 ø.329 Connector 2-M3 female thread, 4.157 deep Sensor 2-ø2.5.98, 5.197 deep M5 female thread, 4.157 deep MS-DP1-1 9.5 14.5.571.374 R13 R.512 t 2 t.79 4.2.165 21.827 3 1.181 13.512 ø2.3 ø.91 1.39 2-R2.1 R.83 2-ø3.5 ø.138 ( ) 5.3.9 5.5 44.217 1.732 Assembly dimensions 45 ( 1.772) 22.866 2-R2.1 R.83 4.2.165 14.5 9.5.571.374 3 1.181 45 1.772 15.591 Sensor mounting bracket (Optional) 24.9.98 1.3.51 4.9.193 ø8.35 ø.329 3 t 2 1.181 t.79 Material: Cold rolled carbon steel (SPCC) (Trivalent uni-chrome plated) Two M3 (length 6 mm.236 in) screws with washers are attached. MS-DP1-5 3 1.181 Sensor mounting bracket (Optional) 22.75.896 4.5.177 29.5 1.161 ø4.5 ø.177 8.5.335 44.5 3 1.752 1.181 28 1.12 Assembly dimensions 16.63 R6.75 R.266 24.9.98 4.9.193 13.5 2-ø3.5 ø.138.531 Material: Stainless steel (SUS34) Two M3 (length 6 mm.236 in) screws with washers are attached. t 1.5 t.59 49.5 ( 1.949) ø4.5 ø.177 29.5 1.161 3 1.181 49.5 1.949 1.122 28.5 4.5.177 ø8.35 ø.329 1.3.51 26.5 1.43 48 1.89 t 1.5 t.59

711 Digital Pressure Sensor SERIES DIMENSIONS (Unit: mm in) The CAD data can be downloaded from the website. MS-DP1-7 Conversion bushing (Optional) 15.8 (.622) Assembly dimensions 3.5.138.5 (. ) 7.8.37 14.551 M5 male thread Gasket 11.433 1.394 8.315 36.4 1.433 Rc 1 /8 female thread Material: Brass (Nickel plated) Weight: 1 g approx. MS-DP1-8 MS-DP1-3 Mounting drawing with Panel mounting bracket (Optional), Front protection cover (Optional) Panel cut-out dimensions ( ) 34.5 1.358 (39.3 1.547) 34.5 1.358 5 1.969 33.4 1.315 Front protection cover 11.433 7.2 12.8.283.54 8.5.335 4.9.193 ø8.35 ø.329 A Panel thickness dimension 1 to 3 mm.39 to.118 in When 1 unit is installed 31.4 1.2.16 31.4 1.2.16 When n units are installed horizontally in series 55 2.165 or more 31 1.2 n + 3.5.138 (n-1) 31.4 1.2.16 When n units are installed vertically in series 31 1.2 n + 3.5.138 (n-1) 31.4 1.2.16 33.4 1.315 (52 2.47 max.) Connector Note: The panel thickness should be 1 to 3 mm.39 to.118 in. 55 2.165 or more Note: The panel thickness should be 1 to 3 mm.39 to.118 in. View A Material: Polyacetal (Panel mounting bracket) Polycarbonate (Front protection cover) CN-14A(-R)-C Connector attached cable (Optional, CN-14A-C2 is attached to the sensor) 35 1.378 8.315 L 5 ( ) ( 1.969) 8 ( ) ( ) ø3.7 ø.146 cable.315 Model No. Cable length L (mm in) CN-14A(-R)-C1 1, 39.37 CN-14A(-R)-C2 2, 78.74 CN-14A(-R)-C3 3, 118.11 CN-14A(-R)-C5 5, 196.85

MEMO 712