Anthropomorphic Phantoms

Similar documents
OBJECT ORIENTED DESIGN OF ANTHROPOMORPHIC PHANTOMS AND GEANT4-BASED IMPLEMENTATIONS ABSTRACT

Towards patient specific dosimetry in nuclear medicine associating Monte Carlo and 3D voxel based approaches

State of the art of voxel phantom development

Development and Use of Computational Anthropomorphic Phantoms for Medical Dosimetry Nina Petoussi-Henss

Katja the 24 th week of virtual pregnancy for dosimetric calculations

ICRP Symposium on Radiological Protection Dosimetry

Tomographic Anthropomorphic Models. Part IV: Organ Doses for Adults due to Idealized External Photon Exposures

EFFECTIVE DOSE RATIOS FOR TOMOGRAPHIC AND STYLIZED MODELS FROM EXTERNAL EXPOSURE TO PHOTONS

Three Dimensional Dosimetry Analyses In Radionuclide Therapy Using IDL And MCNP-based Software Tools

MODELLING RADIATION TRANSPORT IN VOXEL GEOMETRIES WITH THE MONTE CARLO CODE MCNPX

IMPLEMENTATION OF SALIVARY GLANDS IN THE BODYBUILDER ANTHROPOMORPHIC PHANTOMS

Monte Carlo Simulations for In Vivo Internal Dosimetry (including phantom development)

Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code

Computational Anthropomorphic Models of the Human Anatomy: The Path to Realistic Monte Carlo Modeling in Radiological Sciences

GSF MALE AND FEMALE ADULT VOXEL MODELS REPRESENTING ICRP REFERENCE MAN THE PRESENT STATUS

GSF Male and Female Adult Voxel Models Representing ICRP Reference Man

Absorbed Fractions for Multi-Region Models of the Kidneys in ICRP/ICRU Voxel Phantoms

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

Computer-assisted segmentation of CT images by statistical region merging for the production of voxel models of anatomy for CT dosimetry

Computational Phantoms of the ICRP Reference Male and Reference Female

DRAFT TO BE SUBMITTED TO HEALTH PHYSICS JOURNAL

Image-based Monte Carlo calculations for dosimetry

FASH and MASH: Female and Male Adult human phantoms based on polygon mesh surfaces Part II: Dosimetric calculations

Development and anatomical details of Japanese adult male/female voxel models

Mathematical methods and simulations tools useful in medical radiation physics

Construction of Voxel-type Phantom Based on Computed Tomographic Data of RANDO Phantom for the Monte Carlo Simulations

Mesh Human Phantoms with MCNP

3D/4D HUMAN MODELING AND MONTE CARLO DOSE CALCULATION FOR RADIATION PROTECTION, IMAGING AND RADIOTHERAPY

Internal radionuclide dosimetry of model and patient based voxelised phantoms using the GATE toolkit

Voxel phantoms and Monte Carlo methods applied to internal and external dose calculations.

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

DEVELOPMENT OF BIOLOGICAL VOXEL-BASED COMPUTATIONAL MODELS FROM DICOM FILES FOR 3-D ELECTROMAGNETIC SIMULATIONS

An image-based skeletal canine model for pre-clinical evaluations of osteosarcoma molecular radiotherapy

CT vs. VolumeScope: image quality and dose comparison

SESAME: A NEW TOOL FOR THE NUMERICAL DOSIMETRIC RECONSTRUCTION OF A RADIOLOGICAL ACCIDENT CAUSED BY AN

Michael Speiser, Ph.D.

Joint CI-JAI advanced accelerator lecture series Imaging and detectors for medical physics Lecture 1: Medical imaging

Deformation of mesh-type ICRP reference computational phantoms in different statures and postures for individualized dose calculations

Dosimetry Simulations with the UF-B Series Phantoms using the PENTRAN-MP Code System

Radiation Dose Optimization For Critical Organs. Yasaman Khodadadegan

Geant4 simulation in a distributed computing environment

Tomographic Reconstruction

Quantitative imaging for clinical dosimetry

4. Conclusions. 5. References

DUAL-ENERGY CT IN PROTON THERAPY

Av. Professor Lineu Prestes São Paulo, SP ABSTRACT

TWENTY YEARS OF VISUAL MONTE CARLO

Attenuation Coefficients for Layered Ceiling and Floor Shields in PET/CT Clinics

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Library of Mesh and NURBS female phantoms for pulmonary in vivo counting studies

MONTE CARLO SIMULATION FOR RADIOTHERAPY IN A DISTRIBUTED COMPUTING ENVIRONMENT

Improvement in the calibration techniques of approved dosimetry services in Spanish nuclear power plants of whole body counters with NaI detectors.

COMPARISON OF DOSE CALCULATION ALGORITHMS FOR LEKSELL GAMMA KNIFE PERFEXION USING MONTE CARLO VOXEL PHANTOMS

The OpenGATE Collaboration

Development of a mouse computational model for MCNPx based on Digimouse images and dosimetric assays

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

USER MANUAL VP PLANNING

USER MANUAL VP PLANNING

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

Dose Point Kernel calculation and modelling with nuclear medicine dosimetry purposes

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Machine Learning for Medical Image Analysis. A. Criminisi

DIGITAL HUMAN PHANTOM FOR USE IN THE FDTD COMPUTATION

Design and Fabrication of Kidney Phantoms for Internal Radiation Dosimetry Using 3D Printing Technology

Use of Deformable Image Registration in Radiation Therapy. Colin Sims, M.Sc. Accuray Incorporated 1

A Monte Carlo shielding model for PET/CT clinics

ANALYSIS OF CT AND PET/SPECT IMAGES FOR DOSIMETRY CALCULATION

REAL-TIME ADAPTIVITY IN HEAD-AND-NECK AND LUNG CANCER RADIOTHERAPY IN A GPU ENVIRONMENT

Simulation Techniques Using Geant4

A CT-based Monte Carlo Dose Calculations for Proton Therapy Using a New Interface Program

Physics-based Modeling of the Pregnant Woman

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Medical Images Analysis and Processing

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology

Author's Accepted Manuscript

The Recipient of 2015 Randall S. Caswell Award for Distinguished Achievements in the Field of Ionizing Radiation Measurements and Standards

Verification / Validation Tools

Voxels and Medical Applications. FLUKA Beginners course

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

8/3/2016. Image Guidance Technologies. Introduction. Outline

Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam

Effects of the difference in tube voltage of the CT scanner on. dose calculation

LA-UR- Title: Author(s): Intended for: Approved for public release; distribution is unlimited.

Organ-specific SPECT activity calibration using 3D printed phantoms for molecular radiotherapy dosimetry

A New High-Resolution Electromagnetic Human Head Model

gpmc: GPU-Based Monte Carlo Dose Calculation for Proton Radiotherapy Xun Jia 8/7/2013

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Outline. Monte Carlo Radiation Transport Modeling Overview (MCNP5/6) Monte Carlo technique: Example. Monte Carlo technique: Introduction

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

3-D Monte Carlo-based Scatter Compensation in Quantitative I-131 SPECT Reconstruction

Dynamic digital phantoms

Optimization of Beam Spectrum and Dose for Lower-Cost CT. Mary Esther Braswell. Graduate Program in Medical Physics Duke University.

Feasibility study of a new platform based on the Case-Based Reasoning principles to efficiently search and store voxel phantoms

Handling of high resolution imaging data for usage in Monte Carlo calculations

Geant4 in Brachytherapy

GPU-based Fast Cone Beam CT Reconstruction from Undersampled and Noisy Projection Data via Total Variation

Transcription:

Anthropomorphic Phantoms Susanna Guatelli Barbara Mascialino Maria Grazia Pia INFN Genova, Italy IEEE Nuclear Science Symposium San Diego, 30 October 4 November 2006

Anthropomorphic phantoms A precise representation of the human body is important for accurate dosimetry Total Body Irradiation Courtesy of ESA Oncological radiotherapy Radiation protection studies Space science etc. Anderson Rando phantom

Mathematical Phantoms The size and form of the body and its organs are described by mathematical expressions (combinations/intersections of planes, circular and elliptical cylinders, spheres, cones, tori, etc.) MIRD5: Estimates of Absorbed Fractions for Mono-energetic Photon Sources Uniformly Distributed in Various Organs of a Heterogeneous Phantom W. S. Snyder, Mary R. Ford, G. G. Warner, and H. L. Fisher, Jr, J. Nucl. Med. Vol.10, Suppl.3, 5-52 (1969) Many derivations from the MIRD5 phantom MIRD5 revised (1978) Rosenstein et al (1979) Kramer et al (1982): Adam and Eva Jones and Wall (1985) Cristy & Eckerman (1987): new-born and 1-5-10-15 year old children Jones and Shrimpton (1991) Hart et al (1994): all organs of the ICRP91 Report etc.

Voxel Phantoms Based on digital images recorded from scanning real people Computed Tomography (CT) or Magnetic Resonance Imaging (MRI) M. Caon, Voxel-based computational models of real human anatomy: a review Rad. Env. Biophys. 42 (2004) 229 235

Still a hot topic Monte Carlo 2005 Conference, Chattanooga (TN) Session on Tomographic Models for Radiation Protection Dosimetry GSF Male And Female Adult Voxel Models Representing ICRP Reference Man (K. Eckerman) Effective Dose Ratios for the Tomographic Max and Fax Phantoms (R. Kramer) Reference Korean Human Models: Past, Present and Future (C. Lee) The UF Family of Paediatric Tomographic Models (W. Bolch and C. Lee) Development and Anatomical Details of Japanese Adult Male/ Female Voxel Models (T. Nagaoka) Dose Calculation Using Japanese Voxel Phantoms for Diverse Exposures (K. Saito) Stylized versus Tomographic Models: an Experience on Anatomical Modelling at RPI (X. G. Xu) Use of MCNP with Voxel-Based Image Data for Internal Dosimetry Applications (M. Stabin) Application of Voxel Phantoms for Internal Dosimetry at IRSN Using a Dedicated Computational Tool (I. Aubineay-Laniece) The Use of Voxel-Based Human Phantoms in FLUKA (L. Pinsky) The Future of Tomographic Modelling in Radiation Protection and Medicine (Panel discussion)

Anthropomorphic Phantoms revisited A fresh look at an old problem Exploit modern software technology Focus on architectural issues, rather than implementation details Open source code Based on Object Oriented technology Powerful geometry modeling Detailed material description Versatility and precision of physics for dosimetry

Mathematical Phantom versus Voxel Phantom Which technique is better? Both! Each one has its pro and contra (precision, memory usage, speed of simulation execution ) Which one is better depends on one s own specific use case Take the best of And what about a novel unorthodox both worlds approach? Mix and match: composite mathematical-voxel phantoms

ORNL MIRD Adam&Eva VoxelMan NORMAN Golem VIP-man Otoko Frank Max ADELAIDE Donna Helga Irene etc. Which one is the best for my dosimetry study? All None of the existing phantoms My own phantom Mix & match ORNL liver + MIRD heart + Max frame + Frank head And what about embedding an organ from my own CT scanning into a standard phantom model?

Analysis & Design Domain decomposition Abstraction of the process of building a phantom Abstraction of the model of body organs

Assembling a phantom Builder Pattern The process of assembling a phantom is handled through a Builder design pattern Concrete builders treated polymorphically through their base class G4PhantomBuilder Build a phantom by adding anatomy components one by one Customization Implementations G4MaleBuilder G4FemaleBuilder Derive your own class Build just the components you want (e.g. head only)

Standard Phantom Models Mix & Match A Builder may instantiate different BodyFactories, treated through the same abstract interface, and pick organs from different phantom models, or mix organs from standard phantom models with user-created ones Abstract Factory Pattern An Abstract Factory (G4VBodyFactory) is responsible for the creation of anatomy components Concrete factories (e.g. G4ORNLBodyFactory,G4MIRDBodyFactory) implement specific phantom models

Phantom parameters Parameters of anatomy components Geometry, sizes Position and rotation of body elements Materials Stored in satellite files for some standard phantom models Use GDML (Geometry Description Markup Language) GDML Reader can create a Geant4 geometry out of the stored GDML description Easy to provide user-defined phantom parameters Supply your own GDML file with parameters Use one of the standard Factories/Builders to assemble a phantom with your own sizes, materials, positions etc. But you are not forced to use GDML, if you don t wish so

Components in G4PhantomBuilder Skull Thyroid Lungs Breasts Heart Liver Upper Large Intestine Uterus Urinary Bladder Not visible: Geant4-Genova Group(inside the Brain Spine Esophagus Arm Bones Spleen Pancreas Stomach Kidneys Pelvis Ovaries Lower Large Intestine Leg Bones

Female ORNL Anthropomorphic Phantom 3 materials skeleton lung soft tissue G4FemaleBuilder + G4ORNLBodyFactory

Dosimetry Anatomical components can be defined as Geant4 SensitiveDetectors Energy deposit collected in Geant4 Hits

Mix & Match Mathematical phantom with one voxel breast MIRD mathematical breast Dance & Hunt voxel breast D. R. Dance and R. A. Hunt, REPORT RMTPC 02/1005

Dosimetry in mixed mathematical-voxel phantom Dose in each breast voxel 35 30 Dose in analytical organs Energy deposit 25 20 15 10 5 0 17 18 19 20 Uterus 16 Bladder 15 Thyroid 14 Stomach 13 Spleen 12 Skull 11 Pelvis 10 Pancreas 9 Spine Ovary 8 Lungs 7 Liver Intestine 6 Leg bone 5 Kidney 4 Heart 3 Head 2 Brain Breast Arm bone 1

Conclusions OO technology + A novel approach to an old problem + Geant4 powerful functionality = anthropomorphic phantoms Versatility of modeling Precision of Geant4 physics Public release in Geant4 8.2 December 2006 Open source