P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31

Similar documents
DPhy v1.2 Decoder MIPI 2.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. January Rev 1.31

P338 Dual 4-lane MIPI DPhy Probe Data Sheet & User Manual. October Rev 1.1

P5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD

1103 Power Supply (SN B and Above) Instruction Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TCP305A & TCP312A AC/DC Current Probes Instructions

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

DPhy Preprocessor MIPI 1.5Gb/s Protocol Analyzer Hardware DataSheet & User Manual. February Rev 1.2

DPhy Decoder MIPI 1.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. March Rev 1.0

DPhy v1.2 Decoder MIPI 2.5Gb/s Protocol Decoder Hardware DataSheet & User Manual. June Rev 1.0

SCC-AO10 Isolated Analog Output Module

SCC-RLY01 Relay Module

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

RSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions

CTB MIPI CPhy/DPhy Termination Board Data Sheet & User Manual. June Rev 1.2

RSA306B Real-Time Spectrum Analyzer Installation and Safety Instructions

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

KHT 6000 C HV-Probe Calibrator. Instruction Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual

NI PXI-2567 Specifications

80W (16V/5A) Power Supply with USB Output. User Manual

User s Manual Model PBL250 Logic Probe IM E. 3rd Edition

TLA5Fxxx, TLA62F0x, & TLA7Fxxx PowerFlex Field Upgrade Kit Logic Analyzers Instructions

NI PXI-1042 Series Power Supply Shuttle

RSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions

±15 V Current-Limited Power Supply

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

User Manual VX4234 Digital Multimeter Module

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

PanelView Plus/VersaView CE Terminals and Display Modules

CPCI System Subrack 1 U

Metro-Optical Transport Access Nodes

OPERATOR S MANUAL ATE 1/2 RACK POWER SUPPLY AUTOMATIC TEST EQUIPMENT MODEL

PML 791-RO Low-Z Passive Probe. Instruction Manual

MC 11 EB-2 Power supply cabinet with external bus, AC version

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

NI Serial Hardware Specifications Guide

ACCESS 9340/9360 Meter Input/Output Module

Line Impedance Stabilization Network (LISN)

38 MHz Passive Voltage Probe R&S RT-ZP1X

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

OM GHz, OM GHz Optical Modulation Analyzer Installation and Safety Instructions

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

USER MANUAL. Elo Touch Solutions 2D Barcode Scanner Peripheral

General Warranty. For more details, please refer to the user manual on the supplied CD, it can also be downloaded at

GPS Synchronization Module

2 Mesa Ethernet Dock User s Manual

UV Power Flood. User Manual. Order code: EQLED029

USB-2001-TC. USB-based Thermocouple Input. User's Guide

Blitzer Strobe. User Manual. Order code: EQLED366

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

TruVision IP Thermal Camera Installation Guide

Instructions. TLA5Fxxx, TLA6Fxx, & TLA7Fxx PowerFlex Field Upgrade Kits for TLA5000, TLA600, and TLA700 Logic Analyzers

User Guide True RMS Multimeter Extech EX205T

3/4 U CPCI Serial Case System

Crossfire. User Manual. Order code: EQLED061

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

CS2 DMX Distribution Splitter

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

SCXI -1313A Terminal Block

3+1 U CPCI Serial System

5 B&W Rear View System Camera

Network Camera. Quick Guide DC-B1203X. Powered by

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

Mini Digital Multimeter

Service Manual. P GHz Active Probe

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

Safety Standards. Model Number:

User's Guide. Digital Multimeter. Model MN42

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

SIP 3CX Based Private Branch Exchange

User s Manual Power Supply IM E. 5th Edition

designed for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

CPCI System Subrack 3 U

CMSA-100 Manual. Cinema Media Server Automation

DS1000B Series Digital Oscilloscope

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Sentry Series Video Quality Monitors Installation and Safety Instructions

RGB Power Batten. User Manual. Order code: EQLED032

PMT 221A High Impedance Passive Probe. Instruction Manual

Microbar COB System. User Manual. Order code: EQLED137

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

PCT2000. User Manual. Precision current transducer 2000 A

Enclosed Power Supplies

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

PanelView 600 Terminals

NI 6521 Specifications

DC 100 A Current Probe

Transcription:

P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual January 2018 - Rev 1.31

P344 MIPI D-PHY Probe IMPORTANT SAFETY and USEAGE INFORMATION Please review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified. Only The Moving Pixel Company should perform service procedures. Do not attempt service yourself. Return the unit to The Moving Pixel Company for service. While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions related to operating the system. To Avoid Fire or Personal Injury or Damage to Equipment Qualified Personnel to Operate this Product This manual and the product marking assumes that the user has more than basic electrical/electronic circuit knowledge and is a person comfortable by experience and education to safely connect probes to electrical circuits and systems. Do not operate this equipment nor connect it to any circuit or system if you are not qualified to do so by either education or experience. Use Proper Power Cord. Use only the power cord specified for this product and certified for the country of use. Use only the external power supply that is included with the product. Connect and Disconnect Properly. Do not connect or disconnect probes or test leads while they are connected to a voltage source. Ground the Product. This product is not inherently grounded through the grounding conductor of the power cord; it has a floating power supply. The negative lead of the power supply is directly connected to the metal shell of the unit and all SMA connections are also electrically connected to the metal shell of the unit. It is possible that improper connection to an external system could electrify the shell to potentially high voltages above ground. To avoid electric shock, the product must be tied to ground externally. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded. Any markings, symbols, or textual references to ground, GND, and similar refer to the metal shell of the unit and assume that the metal shell is tied to a saftey ground externally.

Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product. The inputs are not rated for connection to mains or Category II, III, or IV circuits. Connect the probe reference lead to earth ground only, no floating grounds allowed. Power Disconnect. The power cord disconnects the product from the power source. Do not block the power cord; it must remain accessible to the user at all times. Do Not Operate Without Covers. Do not operate this product with covers or panels removed. Do Not Operate With Suspected Failures. If you suspect that there is damage to this product, have it inspected by The Moving Pixel Company. Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present. Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry. Provide Proper Ventilation. Refer to the manual s installation instructions for details on installing the product so it has proper ventilation. Symbols and Terms These terms may appear in this manual: WARNING. Warning statements identify conditions or practices that could result in injury or loss of life. CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.

These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. The following symbol(s) may appear on the product:

Before Operating the Instrument Verify the ambient temperature: 5 C to +45 C. Verify the operating humidity: 8% to 80% relative humidity at up to +32 C 5% to 45% relative humidity above +32 C up to +45 C noncondensing, and is limited by a maximum wet-bulb temperature of +29 C (derates relative humidity to 32% at +45 C) Verify the operating altitude: 3,000 m, derate maximum operating temperature by 1 C per 300 meters above 1500 meters altitude. CAUTION. Operate in upright position only, keeping cooling holes on the sides of the unit clear of obstructions. Power Supply Requirements for the external power supply (provided): Source Voltage 100 240 VAC Frequency 50 60 Hz Power Consumption 70 W maximum It may be helpful to check our website for any updates to this documentation before you operate the instrument: http://www.movingpixel.com/mipi.html If you have any questions at all about the warnings or operating conditions listed above: STOP! Do not operate the instrument. Contact The Moving Pixel Company and resolve your question before continuing. Contacting The Moving Pixel Company Phone +1.503.626.9663 US Pacific Time Zone (UTC-8) Fax +1.503.626.9653 Address Email Web site The Moving Pixel Company 4905 SW Griffith Drive, Suite 106 Beaverton, Oregon 97005 USA information@movingpixel.com http://www.movingpixel.com

Declaration of Conformity The Moving Pixel Company declares that the P344 product conforms to the following Standards: EN/IEC 61326-1:2013, Class A Radiated Emissions AS/NZS CISPR 11:2011 Class A Radiated Emissions FCC 15.109(g):2014 Class A Radiated Emissions FCC 15.109:2014 Class A Radiated Emissions ICES-003:2012 Class A Radiated Emissions VCCI:2014-04 Class A Radiated Emissions EN/IEC 61326-1:2013, Class A Conducted Emissions AS/NZS CISPR 11:2011 Class A Conducted Emissions FCC 15.107:2014 Class A Conducted Emissions ICES-003:2012 Class A Conducted Emissions VCCI:2014-04 Class A Conducted Emissions EN61326-1:2013 Industrial in the following areas: 1. IEC 61000-4-2:2008 ESD immunity 2. IEC 61000-4-3:2010 RF electromagnetic field immunity 3. IEC 61000-4-4:2012 Electrical fast transient/burst immunity 4. IEC 61000-4-5:2005 Power line surge immunity 5. IEC 61000-4-6:2013 Conducted RF immunity 6. IEC 61000-4-8:2009 Magnetic Field immunity 7. IEC 61000-4-11:2004 Voltage dips and interruptions immunity Equipment type: Test and measurement equipment, indoor use only. Pollution Degree 2 as defined in IEC61010-1. Rated for indoor use only. This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference. Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object. For compliance with the EMC standards listed here, high quality shielded interface cables that incorporate low impedance connection between the cable shield and the connector shell should be used.

Product end-of-life handling Observe the following guidelines when recycling an instrument or component: Equipment recycling. Production of this equipment required the extraction and use of natural resources. The equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product s end of life. To avoid release of such substances into the environment and to reduce the use of natural resources, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately. This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2012/19/EU and 2006/66/EC on waste electrical and electronic equipment (WEEE) and batteries. For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com). Restriction on Hazardous Substances Directive 2011/65/EU EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restrictions of hazardous substances.

P344 MIPI D-Phy Stimulus Generator 1.0 General: The P344 is a stand-alone D-Phy Pattern Generator. It features 4 data lanes. Data rate operation up to 2.5 Gb/s per lane is supported. LP Voh, LP Vol, HS Voh and Vol are adjustable. Power is from an external 24 V supply (included). This manual assumes that the user has a reasonable level of familiarity with the MIPI D-Phy standard. It is designed to run in conjunction with the DPhyGenCtl software. 2.0 Requirements: The P344 requires a USB2.0 or USB3.0 A Windows Win7/Win8 PC with a USB 2.0 or USB 3.0 connection. Updated versions of the instrument firmware and the DPhyGenCtl software can be freely downloaded from the PG3A website: www.movingpixel.com/dphygen.html.

3.0 Connections The data and clock lane connections on the front panel are made via SMA connectors arranged as illustrated below. Additional indicators and connections: Y yellow LED currently reserved for future use. R red LED currently reserved for future use G green LED currently on after unit boots. TrigOut: SMA carrying the trigger out signal The Trig Out signal swings from about 0.6V to about 1.4V into 50 ohms. The DC output resistance of the signal is quite low so unterminated the output voltage is not much higher. Connections to the rear panel: Starting from the left: DC adapter connection Indicator that power has been applied. General Purpose I/O. USB 3.0 Micro B connector used for communication with a PC.

Evt0 Evt1 GPO0 GPO1 GPI0 GPI1 Details for the connections to the GPIO connector: 25 26 +3.3V G N/C N/C G N/C G 25 23 21 19 17 15 13 11 9 7 5 3 1 26 24 22 20 18 16 14 12 10 8 6 4 2 G N/C N/C G G G G G G G N/C G +3.3V 1 2 The General Purpose I/O connector is not used by most users. We have designed this to take a mass-terminated 2x13 0.1 square pin socket connector. Also we have provided 2 connections that output low current 3.3Vdc and many additional ground connections. The signals Evt0,1, GPI0,1, and GPI 0,1, and +ClockOut and -ClockOut are either reserved for future use or are supplying signals as described in the DPhyGenCtl manual.

4.0 Usage Connect external 24 volt power to P344. Note that there is a green LED visible next to the power connector. A note about the MIPI low power signals: low power signals are not terminated at the user system. Additionally, the output impedance for the low power signals is in the range of 210 ohms. Connection to 50 ohm coaxial cables will result in a very slow rise and fall times (which is anticipated by the MIPI spec) that is length-dependent. This is not an error condition. Cable lengths should also be kept to a minimum (probably should not exceed 0.3m) because of the reflections that will occur in LP mode and the resultant glitches perceived by the user system under test. If you terminate the MIPI signals into a 50 ohm scope, it will be difficult to discern the LP signals they will have about the same amplitude as the standard HS signal. This will not damage the P344.

5.0 Electrical specification for the P344 probe Characteristic Specification Notes Maximum data output rate 2.5 Gb/s per lane HS mode: Voh/Vol -0.1 V - +0.5 V open circuit, user-adjustable, 2 mv resolution 1 HS mode: rise/fall time ~3V/nS Loaded, typ, 20%-80% 200mV risetime is ~70pS LP mode: Voh 0.6 V to +1.8 V open circuit, user-adjustable, 2mV resolution (@Vol = 0V) LP mode: Vol -0.2V to +0.7V 2mV resolution, LP mode: rise/fall time ~14nS/V ~5nS/V typ, 20%-80%, user-system dependent at the sma, no cable HS output resistance 50 Ω nominal, single ended LP output resistance 210 Ω nominal Trig Out electrical details Vol Voh Pattern memory capacity ~0.6V ~1.4V 2 GByte Terminated in 50 ohms DC output resistance is very low. External Power Supply 24 Vdc, 60 watts max supplied with P344 Weight ~1300 grams approximate, without supply Weight, power supply and cord ~620 grams approximate, Overall Dimensions 345mm x 195mm x 80mm Approximate, without supply 1 implies that the minimum amplitude is 0 volts, both single-ended and differential.

For more information, contact: The Moving Pixel Company 4905 SW Griffith Drive Suite 106 Beaverton, Oregon 97005 +1.503.626.9663 phone PST www.movingpixel.com information@movingpixel.com