R&S ESW Test Receiver Release Notes Firmware Version V1.40 SP1

Similar documents
R&S ESR EMI Test Receiver Release Notes Firmware Version V3.36 SP2

R&S ESU EMI Test Receiver. Release Notes. Firmware Version V5.74 SP1. Only an ESU with Windows 7 Operating System is supported

R&S RTA4000 Digital Oscilloscope Release Notes Firmware Version

R&S RTC1002 Digital Oscilloscope Release Notes Firmware Version

R&S ELEKTRA Release Notes Software Version V2.10

R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version

R&S GNSS Test Automation Release Notes Software Version 1.3.2

R&S Spectrum Rider FPH Release Notes Firmware Version V1.50

R&S Spectrum Rider FPH Release Notes Firmware Version V1.40

R&S SMB100B Release Notes Firmware Version

R&S SMA100B Release Notes Firmware Version

R&S RECAL + Release Notes Software Version 4.01

How to Apply MS17-10 to prevent WannaCrypt Attacks

Firmware Release V1.83 SP3

R&S AVG Pattern Import Release Notes Firmware Version 02.25

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.6

How to Apply MS17-10 to prevent WannaCrypt Attacks

R&S CMW Bluetooth Release Notes Software Version V3.2.70

R&S Broadcast Drive Test Release Notes Software Version 03.13

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.7

R&S SGT100A RF Source Base Unit Release Notes FW Version

Release Notes. R&S FSC Spectrum Analyzer

R&S FSVA and R&S FSV Signal and Spectrum Analyzer Release Notes Firmware Version V3.40

R&S DSA DOCSIS Signal Analyzer Release Notes Firmware Version 2.2.1

R&S TSMA Release Notes Firmware Version

R&S NRP-Z51/-Z52/-Z55/-Z56/- Z57/-Z58 Thermal Power Sensors Release Notes

R&S TSMAx Release Notes Firmware Version

R&S RTB2000 Oscilloscope Release Notes Firmware Version

R&S VISA Release Notes Software Version 5.8.6

How to deal with the effects of CVE

R&S FSW Signal and Spectrum Analyzer

Release Notes Revision: 01

R&S AVBrun Sequencer Software. Release Notes. Firmware Version Release Notes. Broadcasting

R&S FSL Spectrum Analyzer Resolving Security Issues When Working in Secure Areas

Release Notes. Revision: 01. R&S FSH4/FSH8/FSH13/FSH20 Handheld Spectrum Analyzer. Firmware Release 2.40

R&S DigIConf Software Release Notes Firmware Version Build 170 SP1

R&S CMW500 CDMA2000 1XRTT and 1xEV-DO Release Notes Software Version

Firmware Version Build 170 SP1

R&S VSE Vector Signal Explorer Release Notes Firmware Version V1.40

R&S Power Meter NRP Release Notes Firmware Version

R&S LXI Class C Support V1.21 (XP)

R&S QuickStep Test Executive Software Flexibility and excellent performance

Resolving Security Issues When Working with the R&S ESIB in Secure Areas

R&S NRP-Z27/-Z37 Power Sensor Module Release Notes Firmware Version 04.18a

R&S NRPV Virtual Power Meter Release Notes Application Version 3.2

R&S InstrumentView Spectrum Analyzer Software Manual

Release Notes. R&S ES-SCAN EMI Measurement Software

TD-SCDMA Mobile Station Test Application Firmware R&S FS-K77

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V3.10

BitLocker White Paper Windows 10

R&S InstrumentView Software Manual

TopSec Mobile Secure voice encryption for smartphones and laptops

R&S MSD Modular System Device Flexible antenna switching and rotator control

R&S ETL TV Analyzer Release Notes Firmware Version 3.40

Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Application Note

Firmware Release V2.40

R&S WinIQSIM2 Simulation Software Release Notes Firmware Version

R&S ELEKTRA EMC Test Software Swift and reliable measurement of electromagnetic disturbances

R&S InstrumentView Software Manual

LabVIEW driver history for the R&S HMC8012 Driver Documentation

R&S FPS Release Notes Firmware Version V1.40 SP2

R&S DVMS DTV Monitoring System Release Notes Firmware Version

1xEV-DO Mobile Station Test

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V4.30SP1

cdma2000/1xev-dv Mobile Station Test

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V2.80

R&S FSH4/8/13/20 Spectrum Analyzer Quick Start Guide

Simple Sequencing Tool for SCPI Commands Application Note

R&S ETL TV Analyzer Release Notes Firmware Version 3.51

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V4.21

R&S SFC / SFC-U / VT-B600 Compact Modulator / USB Compact Modulator / Broadcast TX Modulator Release Notes Firmware Version 02.96

PC Software R&S FS300-K1

R&S Browser in the Box Release Notes

R&S ZN-Z15x Calibration Units User Manual

TopSec Product Family Voice encryption at the highest security level

R&S NGE100 Power Supply Series Reduced to the max

EMC Measurement Software EMC32

Firmware Release 2.4

Firmware Release 2.92 SP3 (NT)

.NET programming interface for R&S GTSL and R&S EGTSL

Voice Quality Measurements with R&S ROMES. Application Note

R&S ZN-Z5x Calibration Units User Manual

SVA1000X Series Spectrum Analyzer. Quick Guide QG0701X-E01A

R&S RTO-K81, R&S RTP-K81 PCIe Compliance Test Test Procedures

R&S SMB100A Release Notes Firmware Version

TSML-W Radio Network Analyzer

SpectrumShot. Software for the GSP-9330 Spectrum Analyzer QUICK START GUIDE REVISION MAY 2016 ISO-9001 CERTIFIED MANUFACTURER

Spectrometer Visible Light Spectrometer V4.4

Resolving Security Issues When Working with the R&S FS315 in Secure Areas

R&S SMW200A Vector Signal Generator Instrument Security Procedures

Application Firmware R&S FS-K5 Release for R&S FSP, FSU, FSQ, FMU, FSUP Analyzer Firmware 4.1x

3G FDD BTS/3GPP HSDPA BTS

R&S SMW200A Creating Tutorials and Interactive Examples Application Sheet

Sending s without the risk! The Rohde & Schwarz Secure Web Interface

Aeroflex 2300 Series Stabilock TETRA Test Sets. Release Notes Firmware Version 2.11

R&S SMB100A RF and Microwave Signal Generator Instrument Security Procedures

22, 2017 RIGOL TECHNOLOGIES, INC.

R&S GP-U gateprotect Firewall How-to

R&S SGS100A SGMA RF Source Instrument Security Procedures

R&S SpycerBox Ultra TL Spec Sheet

Transcription:

R&S ESW Test Receiver Release Notes Firmware Version V1.40 SP1 These Release Notes are for following models of the R&S ESW EMI Test Receiver: R&S ESW8, order no. 1328.4100.08 R&S ESW26, order no. 1328.4100.26 R&S ESW44, order no. 1328.4100.44 We highly recommend to upgrade instruments with firmware 1.31 to 1.31 SP1 or higher 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com Internet: http://www.rohde-schwarz.com Subject to change. R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. The following abbreviations are used throughout this document: R&S ESW is abbreviated as R&S ESW. Release Notes Test and Measurement PAD-T-M: 3574.3288.02/02.00/CI/1/EN/

Current Version and History New s Table of Contents 1 Current Version and History... 3 1.1 New s... 3 1.2 Modified s... 4 1.3 Improvements... 5 1.4 Known Issues... 7 1.5 Modifications to the Documentation... 7 2 Firmware Update... 8 2.1 Performing the Firmware Update on the Instrument... 8 2.2 Performing the Firmware Update from a Windows PC... 9 2.3 Operation with and without Administrator Rights...10 2.4 Installing Firmware Options...11 2.4.1 Firmware options included in basic instrument...11 2.4.2 Enabling Options by Entering Option Key Codes...11 3 Customer Support... 13 Release Notes 1328.4780.00-04 2

Current Version and History 1 Current Version and History 1.1 New s The following table lists the new functions and indicates the version in which the new function was introduced: New s in Firmware V1.40: 1.40 K7: Added Display Lines for all measurement displays. 1.40 The frequency step size in receiver mode can now be configured to be identical for the up and down key and the rotary wheel. New s in Firmware V1.31: V1.31 Support for option ESW-B21 External Mixer New s in Firmware V1.30: V1.30 B10 Support in Receiver Mode V1.30 B10: Supports R&S SGS and R&S SGT V1.30 Spectrum Mode: Added 5.6 MHz Channel Filter V1.30 Support for dbx/mhz for 3dB Gauss Filters V1.30 Added Preselector State and Frequency Stepsize to the Fast Access V1.30 Possibility to rename scan ranges in the scan table V1.30 Display the scan ranges in the receiver diagram V1.30 Hardcopy extended to show a preview before printing. Hardcopy of multiple windows on multiple pages in PDF format is now supported. V1.30 Supports Relative Band Power measurements in Spectrum mode and I/Q Analyzer mode for the display Spectrum. For Band Power measurements the result now supports units other than db and the Band Power Span is added to the result table. V1.30 Remote screen now displays the protocol used for remote control as well as the address of the controlling device (if available). A custom string can also be displayed. New s in Firmware V1.20: V1.20 Support for 4-Channel Click Rate Analyzer. The Click Rate Analyzer Software will be installed with the ESW Firmware. V1.20 Support for option ESW-B8 Resolution Bandwidth > 10 MHz V1.20 Support for option ESW-K7 Analog Modulation Analysis for AM/FM/φM V1.20 Receiver Mode: Added ability to view the transducer correction as trace. V1.20 Receiver Mode: Support for Trace Mathematics V1.20 Added "Disconnect RF" button to toolbar. V1.20 Receiver mode: Improved Time Domain Scan speed by a factor of up to 2 when not using any CISPR Detectors. Release Notes 1328.4780.00-12 3

Current Version and History V1.20 The final measurement detector in receiver mode can be set to None to exclude the specified traces from the final measurement. The remote command is :SENSe1:DETector1:FMEasurement NONE. V1.20 Receiver Mode: New comment field in every row of the Peak List and Final Results List V1.20 Possibility to apply a user defined name to every Quick Saveset by a long touch on the corresponding saveset. V1.20 Receiver Mode: Added Squelch Level display to bargraph V1.20 Spectrum Mode: Added 8 MHz Channel Filter 1.2 Modified s The following table lists the modified functions and indicates the version in which the modification was carried out: Modified functions of Firmware V1.40: V1.40 Switching the AUX port settings for controlling a LISN and the settings for the probe power supply is now global for all operating modes. V1.40 Switching between channels will now put a running scan on hold instead of stopping it. V1.10 The self alignment now uses the same algorithm for the preselector range from 2.3 MHz to 30 MHz and the range from 150 khz to 30 MHz. V1.40 The frequency resolution of the YIG preselector positioning algorithm was increased for frequencies between 8 GHz and 18.5 GHz. Modified functions of Firmware V1.31 SP1: V1.31SP1 Modification to hardware setup algorithms for production internal reasons. Modified functions of Firmware V1.31: V1.31 Receiver Scans can now consist of up to 10,000,001 scan points. V1.31 Real Time Mode can now be used to monitor the complete CISPR band B. Modified functions of Firmware V1.30: V1.30 Scrolling in result tables is now possible by swiping inside the table in addition to using the scroll bars. V1.30 The scaling factor of IQ.TAR files is now taken into account during import I/Q data. V1.30 Scan stop frequency is indicated after starting a scan with too many measurement points. V1.30 YIG preselector positioning algorithm optimized Modified functions of Firmware V1.20: V1.20 Spectrum mode: EMI measurement allows up to 512001 sweep points Release Notes 1328.4780.00-12 4

Current Version and History 1.3 Improvements The following tables list the improvements and indicate which version the issue could be observed: Improvements of Firmware V1.40 SP1: V1.40 Self alignment failed in rare cases on devices with option B24. This issue is solved. Improvements of Firmware V1.40: V1.00 Loading a save set could sometimes lead to an inactive Input 2 LED. This issue is solved. V1.00 K7: Sometimes the marker symbol was not correctly graphically placed on the corresponding trace, although the numeric results were displayed correctly. This issue is solved. V1.00 The self alignment dialog and self test dialog were hidden in rare cases. This issue is solved. V1.00 After switching the trigger preview off and on again in the trigger config dialog, the trigger preview did not appear. This issue is solved. V1.00 The bargraph preview did not appear after activating the bargraph config dialog of the Receiver Mode. This issue is solved. V1.00 Spectrum Analyzer: An active transducer set was not correctly taken into account during the auto leveling. As a consequence the resulting sensitivity of the measurement was lower than expected. This issue is solved V1.00 Switching the preselector below 30 MHz into the 150kHz-2MHz-30MHz mode did not have any effect in spectrum analyzer mode as well as in the stepped scan of the receiver mode. This issue is solved. Improvements of Firmware V1.31SP2: V1.31 IF Analysis was not updated, continuously when using a Quasi Peak Detector in the Bargraph display. This issue is solved V1.30 The instrument could, in very rare cases, show the following message on startup. This issue is solved. Improvements of Firmware V1.30: V1.20 Improved update rate of the Bargraph when changing the receiver frequency using the wheel. V1.10 SEM and Spurious Emission measurements: The drop down box for transducer factors did not show all transducer factors due to missing scroll bars. This issue is solved. V1.10 Zooming into traces with logarithmic x-axis may lead to an invisible trace. This issue is solved. V1.10 The Color Setup is now part of the Save Set. V1.10 Shortcut keys for the k, M and G did not work in limit line entry and transducer dialog entry boxes. This issue is solved. Release Notes 1328.4780.00-12 5

Current Version and History V1.00 Improved Auto Ranging algorithm below 1 GHz. V1.00 Improved frequency response for frequencies below 10 Hz when using the FFT sweep with an RBW of 5 Hz and smaller. Release Notes 1328.4780.00-12 6

Current Version and History Improvements of Firmware V1.20SP1: V1.20 The installation of the R&S Click Rate Analyzer did not succeed in combination with the firmware installation. This issue is solved. V1.20 Shut down of the instrument via the front facing Power Button did not succeed for a certain instrument configuration. This issue is solved. V1.00 The SCPI command :OUTPut1:UPORt:VALue did not work correctly when in Receiver mode. This issue is solved. Improvements of Firmware V1.20: V1.00 The center frequency changed to 4 GHz when activating the LN Preamplifier in Real-time mode. This issue is solved V1.11 IQ Analyzer Mode: Axis scaling in I/Q vector diagram didn t work. This issue is solved V1.00 Parameter Coupling for the RF attenuation value deactivated the Auto Range function in the Receiver Mode. This issue is solved. 1.4 Known Issues The following table lists the known issues and indicates which version the issue could be observed: V1.10 When continuously measuring in Realtime mode, the message "Instrument warming up" remains on the display even after the device has warmed up. 1.5 Modifications to the Documentation Release Notes 1328.4780.00-12 7

Firmware Update 2 Firmware Update The firmware update file for the R&S ESW is one file including the main firmware version number e.g. ESWSetup_V1.00.exe. It will be referred as ESWSetup.exe later in the text. The file can be found on Rohde & Schwarz web page 2.1 Performing the Firmware Update on the Instrument There are three ways to make the setup ESWSetup.exe visible to the device: Using a memory stick: 1. Copy the file to a directory of the memory stick and insert the memory stick into one of the USB sockets of the R&S ESW. Using the remote desktop and copying the installation files to a directory of the instrument: 1. Connect the R&S ESW to your LAN. 2. Start the remote desktop on your PC (C:\winnt\system32\mstsc.exe). 3. Enter the TCP/IP address of the instrument, you want to update. Ensure that the "local resources" > "drives" option is selected and press the "Connect" button. (To get the TCP/IP address of the R&S ESW press the hard key Setup and then the softkey Network + Remote. The IP address consists of 4 numbers between 0 and 255. 4. Login to the instrument (user name: instrument and default password 894129 ). 5. Copy the ESWSetup.exe from your PC to a new folder e.g. C:\FWUpdate. 6. You can now access this directory with the ESWSetup.exe from the R&S ESW analyzer firmware. Using a network drive: 1. Connect your R&S ESW to your LAN, and establish a connection to one of your servers. (Please ask the local IT administrator for support) 2. Copy the ESWSetup.exe from your PC to a directory on this server 3. You can now access the directory with the ESWSetup.exe from the R&S ESW analyzer firmware. Performing the update on the instrument: The firmware update process is performed by the following steps: 1. Switch the instrument on and wait until the Analyzer has resumed operation. 2. Press the "SETUP" hard key, then the softkey System Config, and select the tab Firmware Update. A file browser is displayed to select the proper ESW*.exe setup file. Change the path to the drive and directory which you prepared in the step before (USB stick Release Notes 1328.4780.00-12 8

Firmware Update directory, remote PC directory or directory on a server) and close the dialog with the Install button. 3. Press the "Next" button to come to the selection of the firmware packages. By default all application should be installed. Ensure that the applications needed are selected. 4. Press the "Install" button. The firmware will be stopped and the installation starts. After a few minutes the system restarts automatically. After the restart the firmware installation is complete. After the firmware update the "UNCAL" flag appears. A self-alignment is necessary. 5. Press the "SETUP" hard key, the softkey "Alignment" and then press the button "Start Self Alignment" to invoke the alignment procedure. 2.2 Performing the Firmware Update from a Windows PC The new firmware can also be uploaded without using a memory stick or a network drive. Just a LAN connection from the instrument and a Windows PC is necessary. 1. Run ESWSetup.exe on your PC. 2. Select Remote Installation and click the button Next. 3. Select the Packages which shall be installed and click the button Next. HINT FOR FIRE WALL USERS: The ESWSetup.exe is communicating with the instruments via LAN. Therefore it is necessary that the ESWSetup.exe may pass the fire wall. After adding it to the fire wall rules, restart the scan by clicking on Rescan. 4. After scanning your LAN subnet all found instruments are listed. Select the instruments you want to update. It is possible to select up to 5 instruments for updating in parallel. Release Notes 1328.4780.00-12 9

Firmware Update Please be careful and check twice if you have selected the correct instruments. Depending on your company s network structure also instruments of other departments will show up! 5. Additional help will be displayed after clicking the button Help and further options are available by clicking the button Options. 6. Start the installation by selecting Install 7. Confirm that you want to reboot the instrument in order to activate the firmware update (the instrument then restarts automatically) 2.3 Operation with and without Administrator Rights The analyzer may be operated with or without administrator rights. Some administrative tasks (e.g. LXI functions or network configuration) do require administrator rights. A firmware update is also possible without administrator rights. In the default configuration, auto login is enabled, and the Instrument account with administrator rights is active. This means that no password is required, and the full functionality of the analyzer is available. An additional user account (user name NormalUser with default password 894129 ) is pre-defined. Use standard Windows functionality if you wish to deactivate the auto login mechanism and activate the NormalUser account. Please refer also to the Quick Start Manual of the ESW. Release Notes 1328.4780.00-12 10

Firmware Update 2.4 Installing Firmware Options 2.4.1 Firmware options included in basic instrument The R&S ESW-K7 and ESW-K33 application software package is included in the basic instrument firmware. Therefore, they do not have a separate item in the installer to be selected. 2.4.2 Enabling Options by Entering Option Key Codes This section can be skipped if the option key was entered once. To activate application software packages, you must enter a license key for validation. If a XML-file with an option key was sent to you see the install description below. The license key is in the device certificate or delivered as a part of the software package. The process is performed in the following steps: 1. Press the "SETUP" hard key. 2. Go to the tab Versions + Options 3. Press the button "Install Option". A dialog box is displayed. 4. Enter the option key number using the keypad. 5. Press "ENTER". After a successful validation the message "Option Key valid" is displayed. If the validation failed, the option software is not installed. 6. Reboot the device. Installation of options via XML-file 1. Press the "SETUP" hard key. 2. Go to the tab Versions + Options 3. Press the button "Install Option by XML". A file browser is displayed. 4. Select the path to the XML file (e.g. network drive or USB stick) 5. Press "Select". After a successful validation the message "Option Key valid" is displayed. If the validation failed, the option software is not installed. 6. Reboot the device. Release Notes 1328.4780.00-12 11

Firmware Update Release Notes 1328.4780.00-12 12

Customer Support 3 Customer Support Technical support where and when you need it For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde & Schwarz equipment. Up-to-date information and upgrades To keep your instrument up-to-date and to be informed about new application notes related to your instrument, please send an e-mail to the Customer Support Center stating your instrument and your wish. We will take care that you will get the right information. Europe, Africa, Middle East Phone +49 89 4129 12345 customersupport@rohde-schwarz.com North America Phone 1-888-TEST-RSA (1-888-837-8772) customer.support@rsa.rohde-schwarz.com Latin America Phone +1-410-910-7988 customersupport.la@rohde-schwarz.com Asia/Pacific Phone +65 65 13 04 88 customersupport.asia@rohde-schwarz.com China Phone +86-800-810-8828 / +86-400-650-5896 customersupport.china@rohde-schwarz.com Release Notes 1328.4780.00-12 13