DATA RECORDING SOFTWARE FOR PC

Similar documents
Image Loader Program (ILP) for High Performance Controllers. Book E33 - version 1.03

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

Table of Contents. On-Call Advanced Diabetes Data Management Software V1.0 User s Manual

1. Move your mouse to the location you wish text to appear in the document. 2. Click the mouse. The insertion point appears.

Table of Contents Lesson 1: Introduction to the New Interface... 2 Lesson 2: Prepare to Work with Office

A white icon denotes there are no queries at the present time

N Series BIOS BIOS SETUP UTILITY

U-20 Data Collection Software (U-20 for Win-XP/E) Operation Manual

2. Click New in the upper left corner of the standard toolbar (along the top) to open a new message box.

Lorex Client 7.0 & Lorex Message Master

PART 7. Getting Started with Excel

1. Right-click the worksheet tab you want to rename. The worksheet menu appears. 2. Select Rename.

DOWNLOAD KIT CYCLOCOMPUTER INTRODUCTION. Download unit & Download Software [e-train Data Ver.3] for Windows 98/ME/2000/XP

NEC Versa 4200 Windows 98 Upgrade Information

Contents. Page. Installation ClaroRead Toolbar ClaroRead Features Font... 4 Spacing Homophones... 11

Quick & Simple Imaging. User Guide

Fujitsu LifeBook A Series

RONA e-billing User Guide

Quick Tips & Tricks. Important You must use SEMICOLONS ( ie; ) to separate address when sending mail to multiple users

All textures produced with Texture Maker. Not Applicable. Beginner.

Wavy for PAS&PWR Ver. 5.0

Tremblay Harrison Inc Dufferin St Toronto, ON M6H 3M Version 1.2

NEC Versa 500D/550D Windows 98 Upgrade Information

PowerPoint Basics (Office 2000 PC Version)

Links to Activities ACTIVITY 1.1. Links to Activities Links to Activities

Contents Microsoft PowerPoint Lesson 1: The PowerPoint Window...2 The Quick Access Toolbar...3 The Title Bar...3 Rulers...

N Series BIOS BIOS SETUP UTILITY

Web Accessibility Change Your Mouse Pointer Visibility Handbook

Table of Contents. 1. Intended Use Overview Materials Required System Requirements User Mode 4

3465 Diablo Avenue, Hayward, CA U.S.A Fax:

I.A.M. National Pension Fund Remittance Report Software

DISCLAIMER Whilst every effort has been made

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

PROSIM and Its Installation Guide

User Manual version 1.4 PROG DB. DATA STORAGE PROGRAM for W SERIES weight indicators (Options: OPZWUSB_ ; OPZWDATIPC)

Unit 12. Electronic Spreadsheets - Microsoft Excel. Desired Outcomes

OptionPower 3.2. for Office 2007 STARTUP GUIDE. Interactive Audience Response Systems

User Manual pdoc Signer

Sun VirtualBox Installation Tutorial

MICROSOFT EXCEL TUTORIAL HANDOUT

GDC MEMORIAL COLLEGE BAHAL (BHIWANI)

STAR OFFICE WRITER. Lesson 2

Fujitsu LifeBook N Series

Manual Version 5. STIHL Service Communication. STIHL SC

The DataDude (MS Excel) and Documentation for users are available at: Contents

UPDATING YOUR POS SOLUTIONS NEWSAGENCY SYSTEM

Customizing Windows XP

Remote Tools User Guide

Office 365: . Accessing and Logging In. Mail

Software Operations Manual

DATA ARCHIVING SOFTWARE V.

Microsoft Excel 2010 Basic

Excel Advanced

The Fundamentals. Document Basics

Print Station. Point-and-Click Printing WHITE PAPER

Windows Me Navigating

Cloud Control Panel User Manual v1.1

Touring the Universe through Binoculars Atlas Help File

DriveWizard Plus Instruction Manual

Tables in Microsoft Word

Let s work together. Instructions pcvisit ProfiSupport version from

Quick Reference Guide - Assignment Costing

Troubleshooting in Microsoft Excel 2002

Section 2. Slides. By the end of this Section you should be able to:

WordPsychic. User s Manual. InvoTek, Inc Riverview Drive Alma, AR (479)

Bridgeware Systems War Board Documentation

ShiftWizard User Guide. Version 4

Chapter 2 Surfer Tutorial

WhatsUp Gold 2016 Distributed Edition

GeoWeb Portal. User Manual

MS Access Let s begin by looking at the toolbar and menu of Access.

Word 2007 Appendix B Copy Student Files to Hard Drive

Using Inspiration 7 I. How Inspiration Looks SYMBOL PALETTE

MICROSOFT WORD 2010 BASICS

USING PERFORMANCE PRO An Appraiser s Quickstart Guide. Hrperformancesolutions.net 9/2015 v. 3.4

1. The PowerPoint Window

Design Submission Management & Completion. Steps to Create a Design Submission

Windows 2000 Disk Management

TopPoint User's Guide

Fujitsu LifeBook B Series

Wavy for PAX Ver. 4.0

PowerView for the EnergyPro

Insurer User Manual Chapter 5: Common Functionality

Microsoft Access 2010

TYPING IN ARABIC (WINDOWS 7)

User Guide for ID-e Tag List Feature

N2KExtractor. NMEA 2000 Data Extractor Software. User s Manual

Fujitsu LifeBook N Series

User Guide. Version

Community Medical Centers EMR 10.1 Physician Reference

RITIS Training Module 10 Script. To return to the Florida Analytics main page, select Florida Analytics Tools in the upper left corner of the page.

Version 11. NOVASTOR CORPORATION NovaBACKUP

Guide to SiS RAID Utility for Windows XP / 2000

TA320/TA520 Optical Disk Jitter Analysis Software

Rooms Management Manual

Wavy for PLZ-4W Ver. 4.0

MS Word MS Outlook Mailbox Maintenance

Computer Essentials Session 1 Lesson Plan

Video Management Software

BIOS SECTION S6210/6220

Transcription:

DATA RECORDING SOFTWARE FOR PC (FE-700 Optional Kit) This application software is used for collecting data of date, time, depth, draft, latitude, longitude, speed and course from the Navigational Echo Sounder FE-700. The interconnection between the FE-700 and PC is as follows. FE-700 DISPLAY UNIT FE-701 DISTRIBUTION BOX FE-702 EIA232-TD EIA232-RD GND TB1 4 5 6 COM Cable * < < <2< RXD <3< TXD <5< GND < < PC* Connect to COM port. (Either port will do) *: Local supply Figure 1 Interconnection between FE-700 and PC 1. INSTALLATION 1.1 Installing the program System Requirements The DATA RECORDING SOFTWARE FOR PC runs under Windows 2000/XP, and also 128 MB and more of RAM are recommended. Procedure 1. Insert the program floppy disk supplied with the DATA RECORDING SOFTWARE FOR PC kit into your floppy disk drive. 2. Double-click the floppy disk drive icon to display files in the floppy disk. 3. Double-click the Setup.exe icon. The installation program starts and guides you through the installation process. 4. Follow the instructions displayed on the screen. DATA RECORDING SOFTWARE FOR PC will be installed C: FURUNO FE700 on default. 5. Keep your original floppy disk in a safe place. www.furuno.co.jp

1.2 Setting up the program 1. Click the START button on the Windows to open the Start menu. 2. Move the mouse pointer on the PROGRAM option to open the Program menu. 3. Move the mouse pointer on the Fe700 option. The application menu opens. 4. Move the mouse pointer on the application program icon Fe700 and click it. The DATA RECORDING SOFTWARE FOR PC will start up. The following screen appears. 1.3 Setting the serial port Version information display (displayed three seconds) Figure 2 Start-up Display 1. Select Setting-Serial port from the menu bar. 2. Select the port (COM 1 to COM 9) which has been connected to the PC. 3. Press OK button. 2. OPERATION PROCEDURES Note: If you open the system menu 1, 2 or 3 of the FE-700 during downloading, Communication error! will appear. Press the OK button and repeat from beginning. 2

2.1 Downloading data To download real time data (one second intervals data) from the FE-700, press the Start button on the toolbar, or select Download - Start from the menu bar. Also, pressing F9 key on your keyboard downloads real time data. The data is downloaded at one second intervals and displayed in log (Log mode) or graph (Graph mode) form. Figure 3 Log Mode (text screen) Line (green) Figure 4 Graph Mode (graphic screen) 3

To change the mode, press the or button on the screen or select Mode Log Data / Graph from the menu bar. Also, pressing F7 key or F8 key on your keyboard changes the mode to log mode or graph mode, respectively. To inscribe line (s) on the graphic screen, click the Mark button on the toolbar, or select Option-Mark from the menu bar (or F1 key) at the moment you want to pay attention. M mark is displayed on the text screen. To stop downloading at any time, press the Stop button on the toolbar or select Download - Stop from the menu bar. Also, pressing F10 key on your keyboard stops downloading. 2.2 Downloading RAM data in the FE-700 To download one hour of data (one second intervals data) or 24 hours of data (five seconds intervals data) in the RAM of the FE-700 (accumulated at the Echo Sounder FE-700), select Download - Loading Option - 1h Data or 24h Data. The Download dialog box appears, showing "Now downloading" and indicating data volume. You can cancel downloading at any time by selecting Cancel. Figure 5 Download dialog box When downloading is completed, "Download Completed" is shown. Click the OK button. The downloaded data is saved at a file named after date of the moment you just start downloading. For example, one hour data file is named as 20000717_1h.dat. (This file has created at July 17, 2000.) When you open the file from the FILE menu, you can observe the data in the log mode. 4

2.3 Setting option items The Option menu provides various settings for downloading real time data or depicting graphics. To open the File dialog box, select Option - Option on the menu bar. Click the File tab if it is not already selected. The File dialog box appears. Figure 6 File tab on the Option dialog box File Saving option Create new files at 00:00: New files will be automatically created every day at 00:00. (Initial file is created when the Start button is pressed.) Files will be named as yyyymmdd (year+month+day). Create a new file at specific time period (1h - 24h): A new file is created and data is saved at a period of specified time (hour). Set hour(s) between 1 and 24 hours at 1-hour period. If you set one hour, for example only the recent one hour data is saved and old data is overwritten. The file is named as userfile.dat. Not saving: Data received from the FE-700 is displayed on the screen, but not saved to the hard disk of the PC. Time Interval option Select time interval to extract received data. Extracted data is displayed on the text screen or graphic screen. Auto Printing option Log: Printing is automatically performed every 60 lines of text data. Graphic: Printing is automatically performed every graphic page. Off: No automatic printing. To change a setting, press appropriate radio buttons or press up/down arrow button. After setting as desired, press the OK button. The dialog box closes. 5

To open the Graphic dialog box, select Option - Option on the menu bar and click the Graphic tab if it is not already selected. The Graphic dialog box appears. Figure 7 Graphic tab on the Option dialog box Scale option: Select an appropriate depth scale for graphics, between 5 m to 800 m. Pixels option: Select appropriate number of pixels to display per one received data from the dropdown list to depict the contour of the seabed. The choices are 1, 2, 5 and 10 pixels. Mode option: Select the drawing method for graphics among Solid, Line (Wide) and Line (Narrow). Line Color option: Select seabed color for graphics among gray, red, yellow and black. Back Color option: Select background color for graphics, between black and white. Set Depth option: Select Off to display all depth data. Select On to display depth data which is shallower than depth setting. For On, set the depth you wish to display. A red line (blue when Line Color is set for Red ) appears at set depth position. To change a setting, press appropriate radio buttons or press down-arrow button. After setting as desired completed, press the OK button. The dialog box closes. 6

2.4 Opening a file There are two methods to open a file: File option and Time Selection option. To open a file and display it on the text screen, select the File - Open from the menu bar (or Ctrl +O) or click File Open button. The normal Windows Open File dialog box appears. Select an appropriate file and click the Open button and the Select Data dialog box appears. The Select Data dialog box lets you specify which data to read in. After choosing data, click the OK button. The data is displayed in the log or graph mode. Read in all data. Read in data from a specific date. Read in data from a specific time frame. Figure 8 Select Data dialog box Note: No data is denoted with a black double line. The color is light-blue when there is no data for more than one day. To read data from specified start date/time to end date/time and display it on the text or graphic screen, select File - Time Selection from the menu bar. The Time Selection dialog box appears. Enter start date/time and end date/time, then click the OK button. You can display the time selection data on the text screen or graphic screen. (In this method, the 1h-data file (xxxxxxx-1h.dat), 24h-data file (xxxxxxx-24h.dat) and userfile.dat can not be opened.) You can set the from/to period for maximum 11 hours 59 minutes. Example: From Year 2000/Month 7/Day 5/Hour 13/Minutes 1 To Year 2000/Month 7/Day 6/Hour 1/Minutes 0 Figure 9 Time Selection dialog box 7

2.5 Saving a file Data can be saved with any name in Excel format. Select File - Save as CSV-file from the menu bar or click the Save as CSV-file button. The normal Windows Save as dialog box appears. Type file name, select the location to save and click the OK button. 2.6 Printing a file You may print out data. Select File - Print from the menu bar and then click one of the following depending on your objective. The normal Windows Print dialog box appears. Click the OK button to print out the data. Log Data: Print log mode data. This can also be done by clicking Print Log Data button. Graph (Hardcopy): Print graph mode data. This can also be done by clicking Print Graph Hardcopy button. Graph (All Data): Compress all graph data into one page and print. This can also be done by clicking Print Graph All Data button. 2.7 Displaying version information Select About Program Version from the menu bar to show the version information, see Figure 2 in section 1.2. To close the display, click the OK button. 2.8 Exiting the program Select File Program Exit from the menu bar. The program closes and return to the Windows screen. 2.9 Error Messages Below is a list of error messages shown on the screen. Message Meaning Remedy Initializing error!: COM Failed initialization of COM port. For example, other application uses COM port. Match the serial port setting (section 1.3) with the COM port connection of the PC. Communication error! 8 Failed communication with FE-700. Confirm the connection between FE-700 and COM port of PC. No data Can not open! Could not read or save data. Not enough memory to There was not enough Delete unnecessary files. save! space on the hard disk on the PC. Invalid data! Specified time was wrong. Try to specify date/time again. (less than 12 hours). Not found the data! ( YOSH) Pub. No. OME-23661-G FE-700 DATA REC.SOFT There was no data in the file at specified time. Try to specify date/time again. A : JUL. 2000 G : JUN. 19, 2007