B R E A T H A L Y S E R

Similar documents
Wingmate Rover Components

Thank you for purchasing an AlcoSense Surety breathalyser.

Instruction Manual. 24" and 48" Electronic Digital Level Model Nos &

Instruction Manual. 24" and 48" Waterproof Electronic Digital Level Model Nos &

MODEL: JUPITER. Instruction Manual

MODEL: JUPITER X. Instruction Manual

Contents Introduction... 1 Getting Started... 2 Time and Date... 8 Alerts Messages... 14

TRAC TRAC OWNER'S MANUAL. Ver: HW Safe Community Institute

AlcoScan AL3500 [ AL3500FC ] Operating Manual

An energy metering system that gives flexibility, security and control. Century House, Roman Road, Blackburn, BB1 2LD

Indoor Air Quality Meter/Datalogger

Personal Sound Level Meter

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Contents Introduction... Effective Use of Your Pager.. Features... Getting Started... Battery Information... Installing/Replacing the Battery...

CS-2900DP-FM 2-Way Infinity

Pro II. Sound Level Meter V-9992

MODEL BAC-100 Instructions Manual

User Guide for 7950 V2. Amcom Software, Inc.

SR200 GPS SPORTS WATCH. Keeping you one step ahead. User manual

LE5 Alcohol Tester User Manual

SIGMATEST Operating Instructions

Quick Start Installation Guide V.2.0. Copyright 2012, OmniSite, All Rights Reserved

Model Instruction Manual. Heat Stress Meter. reedinstruments. www. com

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

Lifeloc FC20. Operations Manual. Unlock the Power of Alcohol Testing

Agenda. Charging the QRAE II

PW-II Service Manual PW-II SERVICE MANUAL

User Manual. DE910/DE920/DE920 Ex Alphanumeric POCSAG pager

GPS mini Watch User Manual Introduction. Getting Started. Caution: Step 1) Know your Watch:

REMOTE CONTROL OPERATING INSTRUCTIONS

BOWMONK 2000 OPERATING MANUAL


Introduction. Pager Controls and Indicators

CO Analyzer. The Value Leader TM

LED Wall Clock With Calendar and Temperature Display

Instruction Manual Digital Sound Level Meter

Instruction Manual. Electronic Self-Leveling Dual Grade Horizontal / Vertical Rotary Laser Model No

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

Model 8702 DP-CALC Micromanometer

LE5 Breathalyser User Manual

USER'S MANUAL SUN TELECOM INTERNATIONAL

User's Guide. Datalogging Hygro-Thermometer Model SD500

HYgro-blu. Instruction Manual

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

IMPORTANT SAFETY INSTRUCTIONS

Operation Guide CT32 ENGLISH

Quick Guide v. 1.1 DeFelsko Corporation USA 2012

Motorola Advisor Pro User s Guide

SENSIT HCN Hydrogen Cyanide Analyzer

MTG8 Material Thickness Gauge

Model. Instruction Manual. WBGT Heat Stress Meter. reedinstruments. www. com

OPERATION MANUAL. Pen type, air oxygen and Temp. O2 METER. Model : PO2-250

PILLBOX TIMER WITH PULSEMETER

Functions. Technical Data. Wireless Room Thermostat

Datalogging Hygro-Thermometer

Model 8732 IAQ-CALC TM Indoor Air Quality Meter

Fingerprint Door Lock OPERATOR S MANUAL

AIPB O. ADVISOR Pro. User s Guide

Digital Kitchen Scale

Alpha-Numeric Display Pager. MODEL: AL-924e

Pillbox Timer with Pulsemeter Model: PMP238 User Manual

Fingerprint Door Lock User MANUAL

Barometric Pressure / Humidity and Temperature Datalogger

RS Stock No Instruction Manual RS Input Data Logging Thermometer

BODY SCANNER METAL DETECTOR

GPS Tracking Software Included

Hubbell Power Systems

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

Operation 6035 ENGLISH PROG MENU

C A GA Alle Sprachen / 7 WORD A 4 E 6020 Plus

EasyLog 21CFR Compatible Temperature, Humidity & Dew Point Data Logger with LCD Screen

IDS-801 Series Compact Bench Counting Scale. User Manual

600 g x 0.02 g DIGITAL BALANCE

Carbon Dioxide Monitor Instruction Manual

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

Datalogging Hygro-Thermometer

*GA e9e* MODEL : AP-824 /AP-924

USER S GUIDE INTRODUCTION INTRODUCTION. Contents. Controls

SAVANT PRO 8 APP AT A GLANCE

SMART & NEW! Sensor probe Interchangeable Normal measurement SMART PORTABLE IAQ METER SERIES -3 (SPECIFICATION )

Heat meter User guide Sharky Heat Meters

Introduction. Getting Started. Step 1) Know your watch: GPS 2.0 Watch Instruction Manual. Push button location:

BRAVO LX. User s Guide

SENSIT HCN. Hydrogen Cyanide Analyzer Instruction Manual Model HCN

Smart Nutrition Scale

Press main button again and hold down until "Power OFF" is displayed and the screen goes blank.

Dual Type Coating Thickness Tester LZ-990. Operating Manual

AutoRanging Digital MultiMeter

QUICKSTART: 1. Download app in GooglePlay or the App Store. 2. Turn on Honey by pressing the button for 5 seconds, until you hear a two-tone beep.

HG-21B. Digital Over-Ear Headphones. User Manual

Wireless Digital Video Doorbell CL-3684 USER S MANUAL

J Do not fit rechargeable batteries. j Keep the Trio II away from. L For use in a dry, indoor. J It is not necessary for you to

User's Guide. 3 Channel Datalogging Thermometer Model SD200

Disclaimer External Documents note to reader

CompX elock. Manual Programming Guide

SOUND LEVEL CALIBRATOR DVM1356 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1356 SOUND LEVEL CALIBRATOR 1

RF-Link 2.4GHz Digital Wireless Color Security/Baby Monitor. Model: ABM-4161 User's Manual

User's Guide. Extech CG204 Coating Thickness Tester. 99 Washington Street Melrose, MA Phone Toll Free

User Manual. DE900 Alphanumeric POCSAG pager

DTB-1. Digital Thermometer Battery Powered

Transcription:

BREATHALYSER

Congratulations on buying your new Wingmate Pro breathalyser. We hope you enjoy owning your Wingmate Pro breathalyser. If you have any questions regarding the unit or want to speak with us further, please visit andatech.com.au or call 1300 800 200 (between 9am and 5pm Monday to Friday). Wingmate Pro Components Mouthpiece Slot Breath out (do not cover) Digital LCD Display Power Button Contents: Breathalyser, mouthpieces (x5), AAA batteries (x2), and user s manual Battery Cover (Back) Specifications Sensor Indication of B.A.C Accuracy Operation Temperature Storage Temperature Warm Up Time Response Time Display Power Supply Use Mouthpiece Dimensions (mm) Weight Calibration Fuel Cell Sensor 0.000 to 0.400 %BAC ±0.005 %BAC at 0.050 %BAC 5 C to 40 C 0 C to 40 C 15 ~ 35 seconds 3 ~ 22 seconds 3-Digit LCD Two 1.5V AAA size alkaline batteries Compatible with Wingmate mouthpieces 114 (height) X 47 (width) X 24 (thickness) 61.5g (84g including batteries) Recommended every 500 tests or 6 months, whichever comes first. Australian Standards Requirement: 1 month

Display Device is ready to take a test. Start blowing. Battery low. Replace with new batteries. Test result is displayed as a 3 decimal place %BAC reading Displays test result Dual colour LCD backlight. See Warnings Display section in the manual. Result is above 0.050% BAC Operating Instructions 1. Insert a mouthpiece into the mouthpiece slot 2. Press the power button. ON will display and the breathalyser will start warming up, which will take about 15 ~ 35 seconds. 3. The breathalyser will beep and display BLO on the screen. Blow steadily into the mouthpiece and continue blowing until you hear another beep. (If you do not blow into the breathalyser within 20 seconds, it will automatically switch off. Press the power button to switch it back on.) 4. The breathalyser will display a circling line as it analyses the breath sample. It will then beep and display the result for 20 seconds. backlight will change to red and display WARN and sound an audible alert. dim down in the last 5 seconds). another test. The breathalyser will start warming up for a second test. 5. To take another test, repeat from step 2. 6. Switch the breathalyser off by pressing the power button for 2 seconds. Please note:

Warnings Display The breathalyser s LCD Backlight will turn red when any of these errors occur. If the result is higher than 0.050% BAC, the breathalyser will display WARN and sound an audible alert. If the result is above 0.400% BAC, Hot signal is displayed along with alarm sound. If you have tested over 500 times, CAL will show up on the display screen for 3 seconds before warming up for a test. Please send the breathalyser back for calibration. The battery voltage is too low to perform a test. The device will turn off automatically after showing this signal. Please replace with new 1.5V alkaline batteries. The breath sample was not strong enough for a measurement. Please power on the unit again and make sure the breath is strong and steady during sampling. When the ambient temperature is out of the working temperature range (5 C~ 40 C) the unit shows OUT and then turns off. Keep and use the unit within the recommended temperature range. How to Change Batteries Step 1: Apply a small amount of pressure on the battery cover located on the back of the unit. Step 2: Push down and away from the unit to release the cover. Step 3: Replace with new alkaline batteries in the proper positive(+) and negative(-) positions as indicated. Then, replace the battery cover.

unit Pro The Wingmate Pro uses a fuel cell sensor to measure breath alcohol levels. Depending upon the amount of alcohol registered by the sensor after a period of time, it will require recalibration. Andatech recommends the Wingmate Pro is calibrated every 6 months or after 500 uses, whichever comes first. To maintain the unit to Australian Standards, calibration every one (1) month is required.

Version 1.0. Updated December 2015.

Product Registration Wingmate Pro