USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

Similar documents
FX-485PC-IF RS485 Interface Unit Hardware Manual

FX1N JAPANESE SPECIFICATION UNITS

FX-1HC SPECIAL FUNCTION BLOCK USER'S GUIDE

FX1N-2EYT-BD Output Expansion Board

FX1N-4EX-BD Input Expansion Board

FX2N-4AD-PT SPECIAL FUNCTION BLOCK

FX2NC-ENET-ADP Ethernet adapter USER'S MANUAL

HARDWARE MANUAL GRAPHIC FX-50DU-TK(S)-C UNITS

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

USER S MANUAL. FX2N-32ASI-M AS-interface Master Block

INTRODUCTION FX2N-1HC SPECIAL FUNCTION BLOCK USER S GUIDE

MODEL: R2K-1 SEN TRONIC AG. R2K Series

1) Indicates that the identified danger WILL cause physical and property damage.

USER S MANUAL. FX2N-32DP-IF Profibus-DP Interface Unit

Guidelines for the Safety of the User and Protection of the F940WGOT Series.

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

USER S MANUAL. FX2N-5A Special function block

FX-10GM POSITIONING CONTROLLER USER'S GUIDE

Safety Relay Unit (I/O Unit Type)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

USER'S MANUAL - MODBUS Serial Communication Edition FX3U SERIES PROGRAMMABLE CONTROLLERS

User safety and equipment protection guidelines

Guidelines for the Safety of the User and Protection of the F94*GOT-*WD-E

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

VB -1HC SPECIAL FUNCTION BLOCK USER'S GUIDE

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Programmable Relay ZEN V2 Units

SYSMAC Remote Transistor Module

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Communication Controller CC-Link/CPL Converter CMC10A

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

1) Indicates that the identified danger WILL cause physical and property damage.

Conductive Level Controller

Manual name Manual No. Description. When installed to a PLC 2 (0.07) (1.57) (0.35) (1.03) (0.86) 28 (1.1) (0.55) 2.6(0.1) (1.25) 8 (0.31) 8 (0.

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

V E2B Snap-in I/O Module

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Model Number Structure

FX3S/FX3G/FX3GC/FX3U/FX3UC SERIES PROGRAMMABLE CONTROLLERS USER'S MANUAL. MODBUS Serial Communication Edition

TABLE OF CONTENTS. Communication Functions

EX-RC1 Remote I/O Adapter

DC I/O Conversion Module

Specifications. 2.1 General Specifications. Operating ambient temperature 0 to 40 C Storage ambient temperature -20 to 60 C

RS232C/RS485 Data can be easily monitored by LAN

V E1B Snap-in I/O Module

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Electronic timer CT-ARS.11

DC I/O Conversion Module FA-TB32XY

MODEL: GR8-EM. Communication Adaptor GR8 Series

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

PRODUCT OVERVIEW. Redundant CPUs. High speed µs processing. Redundant power supplies. Large 62K-word program and 24Kword data memory capacity

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

LC0 DVP

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Maximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual

V E1B Snap-in I/O Module

Suitable for detecting transparent films or transparent bottles

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

USER S MANUAL FX-10DM-E DISPLAY MODULE

Ordering Information. Interface Converter K3SC. List of Models

HARDWARE MANUAL FX1N SERIES PROGRAMMABLE CONTROLLERS

V-3000 Series Miniature Basic Switches

Electronic timer CT-ERS.21

I/O delay. (0.32 in ±0.06 in)

MODEL: R1M-GH. PC Recorders R1M Series

EX-RC1 Remote I/O Adapter

Electronic timer CT-ERD.12

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

Package Contents. GP Options (Made by Digital)

Appendix 3 Using NS-AL002 Converters

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

This manual classifies the safety precautions into two categories: and.

Solid State Relays with Failure Detection Function

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Programmable Controller Analog Terminal Block Conversion Module FA1-TBS40ADGN, FA1-TBS40ADDG, FA1-TBS40DAG User's Manual

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

USER'S MANUAL. FX3U-64DP-M PROFIBUS-DP Master Block

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Ordering Information. Interface Converter K3SC. List of Models

Inductive Proximity Sensor

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

EX-RC1 Remote I/O Adapter

[ ACD-NA ] User s Manual. O-Sung Electric Machinery Co., Ltd. 136, Hataemal-gil, Wollong-Myeon Paju-si, Gyeonggi-do, Korea

Terminal block 2 A 5 X 3. Specification

Electronic timer CT-AHD.22

Transcription:

FX- COMMUNICATION ADAPTER FX0N- COMMUNICATION ADAPTER USER'S GUIDE JY992D53201C This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX and FX0N, 485 communication adapters. It should be read and understood before attempting to install or use these units. Further information can be found in the FX PROGRAMMING MANUAL, FX and FX0/FX0N series hardware manuals. When the FX0N- is used with the FX2N series programmable contoller, please see the FX2N-485-BD USER'S GUIDE for operation.

1 INTRODUCTION The adapter for FX- RS485 or the adapter for FX0N- RS485 (both called hereinafter) is designed to link the data between PC and computer by using 485PC-IF. (1)Data exchange by request from computer Specified data can be exchanged by sending a request command from the computer to the PC. Except for few functions (global function, on-demand function), the program for data link is not needed at the PC side. Batch read / write of all devices (word unit, bit unit) of PC is possible. By reading out the content of each device of the PC, the operating state can be monitored, or the data can be acquired and analyzed. Besides, by writing data into each device, production control and production direction can be effected. Remote run / stop of PC is possible. A stopped PC can be started and stopped again from the computer, and therefore the PCs are remote controlled. A batch instruction can be issued to all PCs. When one computer and plural PCs are connected, a specific device (special auxiliary relay M8126) can be turned on or off from the computer to all PCs on the circuit. This function is called the global function. This special auxiliary relay M8126 is an exclusive device for global function. (2)Data exchange by request from PC If transmission of emergency data from the PC to the computer is necessary, the PC issues a send request to interrupt in the computer. This function is called on-demand function, and is enabled only when the system is composed of one computer and one PC. 1.1 External dimensions FX- 2 3 4 5 140 (5.51) MITSUBISHI FX- 2- φ5.5 (0.22) Mounting hole 1 12.5 (0.49) 25 (0.98) 125 (4.92) FG 24+ 24G 6 7 45 (1.77) Weight : Approx. 0.3 kg (0.66 lbs) Units : mm (inches) 1 Direct mounting hole 8 9 10 (0.39) 2 Power LED lighting while power is correctly supplied. 3 RD LED lighting while receiving data. 4 SD LED lighting while sending data. 5 Terminal screws (M3 (0.12)) 6 Extension cable 7 Terminal cover 8 Groove for mounting DIN rail (DIN rail width : 35 (1.38)) 9 Hook for mounting DIN rail 10 Top cover FX0N- 2- φ 4.5 (0.18) 90 (3.54) 80 (3.15) 4 (0.16) 43 (1.69) 10 2 3 4 6 FX0N- Weight : Approx. 0.3 kg (0.66 lbs) Units : mm (inches) 9 (0.35) 87 (3.43) 1 8 9 5 24+ 24G FG 24+ 24G FG

,,,, 1.2 System configuration The system configuration of computer and PC is either 1 : 1 or 1 : n, and for communication with the computer, the RS-485 or RS-422 is used.,,, (1) Computer and PC by 1 : 1 configuration : RS-232C interface FX,FX2C : RS-485 interface series PC : RS-232C cable : Computer 485PC-IF Station No.0 RS-422 or RS-485 cable,,,,,,,,,,, Max. 500m (2) Computer and PC by 1 : n configuration In this case, the number of link stations is 16 PCs at maximum for one computer, including the FX series PCs and A series PCs. Such system of data exchange with plural PCs with one computer is called the multi-drop link system.,,, Computer FX series PC FX series PC FX series PC CPU A series PC 485PC-IF Station Station Station No.0 No.1 No.2 Station No.15,,, Max. 16 stations including A series PCs (total extension distance 500m),,, Computer link unit : RS-232C interface : RS-485 interface : RS-232C cable : RS-422 or RS-485 cable

For setting up the system, the can be connected to the following PCs. FX0N- FX- PC series FX0N FX, FX2C PC version Ver. 1.20 or later Ver. 3.30 or later Remarks Exclusive protocol format 1 and format 4 are supported. Exclusive protocol format 1 and format 4 are supported. As for exclusive protocol formats (1, 4), see the 485PC-IF manual. For connection with the PC, connect the serial port provided at the left side facing the PC basic unit and the extension cable of the. It must be noted however that only one special adapter (FX-8AV, FX-232ADP, etc.) such as can be connected to the PC. In the case of FX0N- In the case of FX- MITSUBISHI 24G 24+ FG 1.3 Applicable PCs 1.4 Connection with PC FX- 2 WIRING The connecting method with the 485PC-IF is available in two-pair wiring and one-pair wiring, which may be used as follows. As for connection of the 485PC-IF and computer, see the 485PC-IF manual. Two-pair wiring is required when : 1 The RS-422 device is incorporated in the system configuration. 2 A high speed response is required (message waiting time * is desired to be less than 70 ms). 3 The on-demand function is used (however, the system configuration must be 1 : 1). 4 Adding to a system already using two-pair wiring. * See the 485PC-IF manual. One-pair wiring is required when : 1 Adding to a system already using one-pair wiring. 2 The system configuration is standardized to RS-485 devices, and two-pair wiring is not needed.

2.1 Examples of two-pair wiring (for RS-422 circuit) (1) When connecting one computer and one PC 485PC-IF Signal name R *1 R *1 Cable connection and signal direction Grounding resistance of 100 Ω or less FX base unit DC24V 485PC Signal name R *1 R 1 FG *2 24V *3 24G *3 Application Reception data Reception data Transmission data Transmission data Signal ground Frame ground Power supply terminal Power supply terminal (2) Computer and PCs in 1 : n connection ( n has a maximum value of 16 ). The terminal lagout shown is diagrammatic only. As for, see chapter 1, and as for 485PC-IF, and computer link unit for A series PC, see the individual manuals. Computer 485PC-IF Computer link unit of A series PCs SD R *1 SD Station No. 0 Station No. 1 Station No. 15 R *1 RD R *1 RD *2 FG *2 FG *2 FG *1 R *1 R is the terminating resistance. Connect the terminating resistance (330 Ω) between terminals and, and terminals and. For details see section 2.3. *2 Connect terminal FG to earth terminal of the PC main body grounded with resistance of 100 Ω or less. However, as for the computer link unit of the A series PC, see the manual of the computer link unit. *3 The 24V DC power requirement can be taker from the service power supply of the PC.

2.2 Examples of one-pair wiring (for RS-485 circuit) (1) When connecting one computer and one PC 485PC-IF Signal name R *1 Cable connection and signal direction Grounding resistance of 100 Ω or less FX base unit DC24V Signal name R *1 FG *2 24V *3 24G*3 Application Reception data Reception data Transmission data Transmission data Signal ground Frame ground Power supply terminal Power supply terminal (2) Computer and PCs in 1 : n connection ( n has a maximum value of 16 ). The terminal lagout shown is diagrammatic only. As for, see chapter 1, and as for 485PC-IF, and computer link unit for A series PC, see the individual manuals. Computer 485PC-IF Station No. 0 Station No. 1 Station No. 15 SD SD RD RD R *1 *2 FG *2 FG *2 FG *1 R *1 R is the terminating resistance. Connect the terminating resistance (110 Ω) between terminals and. For details see section 2.3. *2 Connect terminal FG to earth terminal of the PC main body grounded with resistance of 100 Ω or less. However, as for the computer link unit of the A series PC, see the manual of the computer link unit. *3 The 24V DC power requirement can be taker from the service power supply of the PC.

2.3 Terminating resistances The terminating resistances are resistances connected between terminals and, and between terminals and at both end stations of the circuit (or the interface when an interface such as 485PC-IF is used at both end stations), when connecting with the RS-485 or RS-422 circuit. For connection examples, see section 2.1 and 2.2. Classification of terminating resistances In this product, two sets of terminal end resistances (330 Ω 2, 110 Ω 1) are packaged, and the terminating resistances to be connected differ as shown below depending on the circuit being used. When communicating with the RS-422 circuit, connect the resistances of 330 Ω 1/4W as the terminating resistances. When communicating with the RS-485 circuit, connect the resistances of 110 Ω 1/2W as the terminating resistances. 330 Ω 110 Ω Two-pair wiring Orange Brown Brown Orange One-pair wiring Terminating resistance (330 Ω) Terminating resistance (330 Ω) Terminating resistance (110 Ω) 2.4 Cautions for wiring As one of the conditions for exhibiting the function of the sufficiently and building up a reliable system, external wiring resistant to noise is essential. Cautions for external wiring are given below. (1) In this system, the data is read or written (turned on or off by force) while the PC is operating. Accordingly, if abnormal data is written into the PC due to effect of noise, the PC may malfunction, leading to machine trouble or accident, and therefore the following cautions should be strictly observed. Never lay near or bundle together with the main circuit, high voltage line or load line. Or effects of noise or surge induction may be serious. Keep at least a safe distance of over 100 mm from these lines. Ground the shield wire or shield of shield cable at one point at the PC side. Never ground commonly with high voltage line. (2) Terminals screws of terminal block for RS-485 are M3 threaded. Therefore, connect wiring by fitting a crimped terminal suited to the terminal screws (see below) to the cable. M3 M3 threads threads 6.2 mm (0.24 inches) or less 6.2 mm (0.24 inches) or less (3) Tightening torque of terminals is 0.5 to 0.8 N m (5 to 8 kgf cm). Screw terminals must be secure enough to prevent a loose connection from causing a malfunction.

3 Environmental specifications Operating ambient temperature Humidity no condensation Vibration resistance Shock resistance Noise immunity Dielectric withstand voltage Insulation resistance Ground Operating ambience SPECIFICATIONS 0 to 55 C, storage temperature -20 to 70 C 35 to 85% RH (No condensation) Conforming to JIS C 0911. 10 to 55 Hz, 0.5 mm (max. 2G), 2 hr each in 3 axes; however, 0.5G when mounting DIN rail. Conforming to JIS C 0912. 10G, 3 times each in 3 axes Noise voltage 1000V p-p, noise width 1µsec, period 30 to 100 Hz, by noise simulator. 500V AC, 1 min Between all terminals in batch and FG terminal 500V DC, 5 M Ω by Megger Grounding resistance of 100 Ω or less (class 3) Free from corrosive gases, minimal dust. Power source specification and type of isolation Supply voltage Current consumption Type of isolation 5V DC (supplied from PC), 24V DC ±10% External power supply : 24V DC, max. 50 ma Internal power supply from PC : 5V DC, max. 30 ma Power source is isolated by transformer ; PC and communication signal lines are isolated by photo coupler. Performance specification Transmission specification * For detail of Special D8120, D8121, and D8129, see the 485PC-IF manual. Item Interface Communication method Synchronization method Transfer speed (bps) Data format Error detection Start bit Data bit Vertical parity bit Stop bit Parity check Sum check Transfer control procedure Access cycle Circuit configuration (computer : PC) ransfer RS-485, RS-422 distance RS-232C Station numbers Time-out judging time FX0N (Special D8129 ) FX, FX2C Specifications Conforming to RS-422 / 485. Exclusive protocol, half-duplex communication system Start-stop synchronous system 300,600,1200,2400,4800,9600,19200 1 7 or 8 The communication format of the PC is set using 1 or none special D8120. * 1 or 2 Odd / even / none Yes / no Protocol format 1 or format 4 One request is processed at the time of END processing of sequence program. Therefore, access cycle is one scan time. 1 : 1 or 1 : n (n = 0 to 15, max. 16 stations) Total extension within 500 m Within 15 m 0 to 15 (set by Special D8121 ) 1 to 255 (10 to 2,550 ms) ; however, setting of 0 hrenders 100 ms. 1 to 3,276 (10 to 32,760 ms) ; however, setting of 0 hrenders 100 ms.

4 COMMAND AND DEVICE RANGE 4.1 Computer commands Command Symbol ASCII code BR WR BW WW BT 42H,52H 57H,52H 42H,57H 57H,57H 42H,54H Function To read out on/off state of bit device in batch in the unit of 1 point. To read out on/off state of bit device in batch in the unit of 16 points. To read out numerical data stored in word device in batch in the unit of 1 point. To write on/off state into bit device in batch in the unit of 1 point. To write on/off state into bit device in batch in the unit of 16 points. To write numerical data into word device in batch in the unit of 1 bit. To specify bit device at random in the unit of 1 point, and set/reset by force. Objective Number of processing points done by one communication device symbol X,Y,M,S,T,C X,Y,M,S T,C,D X,Y,M,S,T,C X,Y,M,S T,C,D X,Y,M,S,T,C FX0N 54 points 13 words, 208 points 13 points 46 points 10 words, 160 points 11 points 10 points FX, FX2C 256 points 32 words, 512 points 64 points 160 points 10 words, 160 points 64 points 20 points WT RR RS PC GW 42H,54H 52H,52H 52H,53H 52H,43H 47H,57H To specify bit device at random in the unit of 16 points, and set/reset by force. To specify word device at random in the unit of 1 point, and write data by force. To remote-run the PC. To remote-stop the PC. To read out the type name of PC. To turn on/off global signal (special auxiliary relay M8126 in FX series) to all PCs connected to computer link. To transmit the data received from computer directly back TT 54H,54H to the computer. * Counter except for high speed counter, 32-bit counter (C200 to C255). X,Y,M,S T,C *, D Special auxiliary relay M8126 6 words, 96 points 6 points 1 points 25 characters 10 words, 160 points 10 points 1 points 254 characters 4.2 PC commands The command to be effected from the PC is the on-demand command only. This command can be used only when the system configuration is 1:1. In this on-demand command, the content of the data register specified at the PC side is transmitted to the computer side from the PC side. The maximum number of points of the data register that can be transmitted as follows. PC series FX0N FX, FX2C Max. number of points 13 words 64 words 4.3 Device range Bit device Word device Device Input relay Output relay Auxiliary relay State Special auxiliary relay Timer contact Counter contact Timer present value Counter present value Data register File register RAM file register Special data register ( X) ( Y) ( M) ( S) ( M) ( T) ( C) ( T) ( C) ( D) ( D) ( D) ( D) Device number range (characters) FX0N series PC X0000 ~ X0177 Y0000 ~ Y0177 M0000 ~ M0511 S0000 ~ S0127 M0000 ~ M8254 TS000 ~ TS063 CS000 ~ CS031 CS235 ~ CS254 TN000 ~ TN063 CN000 ~ CN031 CN235 ~ CN254 D0000 ~ D0255 D1000 ~ D2499 D8000 ~ D8255 FX, FX2C series PC X0000 ~ X0337 Y0000 ~ Y0337 M0000 ~ M1535 S0000 ~ S0999 M8000 ~ M8255 TS000 ~ TS255 CS000 ~ CS255 TN000 ~ TN255 CN000 ~ CN255 D0000 ~ D0999 D1000 ~ D1999 D6000 ~ D7999 D8000 ~ D8255 Decimal/Octal expression Octal Decimal As for timer and counter, it must be noted that the character symbols differ as follows between the bit device and word device. Timer Counter Bit device (contact) TS CS Word device (present value) TN CN

5 DIAGNOSTICS In case of trouble, check the following points, and remedy according to the troubleshooting guide in the 485PC- IF manual. (1) Power LED Lit : The extension cable is normally connected to the PC. Otherwise : The extension cable is not connected correctly, or external 24 V DC power supply is not functioning correctly. Check and connect correctly. (2) As for SD LED, RD LED, check and remedy according to the troubleshooting guide in the 485PC-IF manual.

6 START UP PROCEDURE Prior to start of operation, follow the procedure below. As for detail of procedure, see the 485PC-IF manual. Determine system configuration See section 1.2. (1) Setting of transfer specification (D8120) Specification of data length Specification of parity Specification of stop bit Specification of transfer speed (baud rate) Specification of sum check Specification of transfer procedure (exclusive protocol) (2) Setting of station number (D8120) (3) Setting of time-out check time (D8129) For each item of the communication format e. g., station number, timeout check time, please see the 485PC-IF manual. When using the FX0N series PC, be sure to turn on the special auxiliary relay M8120 because special data registers D8120, D8121, and D8129 are reserved. When the special auxiliary relay M8120 is in an ON state, it must be noted that the backed up data registers D254, D255 become general data registers. Creation of program at computer side External wiring Create communication program on the computer by using BASIC or the similar programming tools. See section 2.1 and 2.2. Connection of terminal end resistance See section 2.3. Loop test Execute loop test, and confirm data exchange. For details see the 485PC-IF manual. Creation of sequence program for data transmission and reception When using on-demand function or global function, the sequence program for transmission and reception is required at the PC side. For details see the 485PC-IF manual. Operation

Guidelines for the safety of the user and protection of the FX-, FX0N- communication adapter This manual has been written to be used by trained and competent personnel. This is defined by the European directives for machinery, low voltage and EMC. If in doubt at any stage during the installation of the FX-, FX0N- always consult a professional electical engineer who is qualified and trained to the local and national standards. If in doubt about the operation or use of the FX-, FX0N- please consult the nearest Mitsubishi Electric distributor. Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment. All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples. Manual number : JY992D53201 Manual revision : C Data : AUGUST 1997 HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUCH TOKYO 100 HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN TELEX : J24532 CABLE MELCO TOKYO JY992D53201C Effective AUG. 1997 Specifications are subject to change without notice.