Pulse Input Adapters (Part # S-UCC/D-M006) for use with HOBO H21 and H22 Series Data Loggers

Similar documents
12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

8-Bit Temperature Smart Sensor (Part # S-TMA-M0XX)

HOBO State Data Logger (UX90-001x) Manual

HOBO State Data Logger (UX90-001x) Manual

For HOBOware Pro Software. User s Guide

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

1000 Series Data Logger

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

For HOBOware Pro Software. User s Guide

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

Tempco Instruction Manual

PMDX-170 Slotted Optical Sensor

Adapter Kit - Remote QSI Electronics Installation Instructions

9500 and 9600 I/O Card Installation Instructions

Satellite INSTALLATION GUIDE

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

MTX-A Temperature Gauge User Manual

WS115 BREAKOUT ADAPTER USER MANUAL

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Quick Draw Electronics. Shooting Sports Timer User Manual. Model AIO-1

TR-3000 STORM WATER SAMPLER MANUAL OF OPERATION.

V-9939B MICROPHONE ADAPTER

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

User's Guide. Extech AM A AC Analog Clamp Meter

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Product Manual MNX10043 REV A MODEL DSB. Dual Sensor Modular Switch box

Progressive Industries, Inc. EMS Electrical Management System

USER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

V-9939C MICROPHONE ADAPTER

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Visit us at

JR3 EXTERNAL SENSOR ELECTRONICS WITH SERIAL DATA OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

4" AMPLIFIED RECESSED CEILING SPEAKERS 8" AMPLIFIED RECESSED CEILING SPEAKERS

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

Atlas. GPI Smart Matrix. User Manual

PagePac PAGEPAC PLUS ZONE EXPANSION UNIT V

Measurement Systems Datascan Installation and User Guide

EMS Electrical Management System

MUTING VOLUME CONTROL CONNECTION TERMINAL

VADDIO /CANON BU-SERIES PTZ CAMERAS

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

ES-600 Ozone Controller Operation Manual

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Irrigander 8/2 Pro Expander 8 Zone Irrigation Expander Installation & User Guide Model 8ZEXT V1.0

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2

An ISO-9001 Certified Company

OZONE SWITCH Model OS-6. OS-6 Features

DI-148U. User's Manual. The way PC-based instrumentation should be. 8-Channel USB Data Acquisition Starter Kit. Manual Revision B

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

JR3 EXTERNAL SENSOR ELECTRONICS WITH ANALOG OUTPUT. JR3, Inc. 22 Harter Ave. Woodland, CA 95776

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

PRO REMOTE 25 LV CAPACITANCE PROBE

Remote Water Level Monitoring Technical Note Product: HOBO RX3000 Station

PMDX-105 Quad Isolator Board

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Global Water globalw.com. Global Water. Instrumentation, Inc.

HOBO Motor On/Off Data Logger (UX90-004x) Manual

Chapter 1 Introducing the OM-USB-1608FS-Plus... 6 Functional block diagram... 6

EMS Electrical Management System

ANSI C Dimming Receptacles

Precipitation Station Manual V /20/2001

OPERATION MANUAL MODEL TT-LP

Telephone Line Monitor USER GUIDE

Digital Lighting Systems, Inc.

MTX-A, Fuel Pressure Gauge PSI

Adjustable Timing Control PN 8680

Installing Sentor. Hardware Installation

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

INSTRUCTION and OPERATIONS MANUAL. for

EMS-LCHW30 & EMS-LCHW50

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

Drive 3G-S ENGLISH. Cellular Signal Booster A Customer Support: Mon-Fri 8 am to 6 pm.

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

Hybrid AC Driver [GCNC-1110]

Installation Operation

OPERATIONS MANUAL PCM-I/O48

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

INSTRUCTION MANUAL. SGB20(D) Transient Protection System. June Copyright 2008 Campbell Scientific (Canada)Corp.

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

SERIES 5100 INSTALLATION & SPECIFICATION GUIDE

V-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT

MIR-K16S-2101Q IR Distribution Kit with 6 Ports

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

DIN Molded Cable Assemblies

Transcription:

s (Part # S-UCC/D-M006) for use with HOBO H21 and H22 Series Data Loggers The s are used to log the number of switch closures per interval and are designed to work with smart sensor-compatible HOBO data loggers. The adapter has a plug-in modular connector that allows it to be added easily to these loggers. Two versions are available: one for mechanical contact closures (ideal for connecting tipping-bucket rain gauges to HOBO H21 series loggers), and one for solid-state electronic switches (used for connecting compatible pulse output sensors to HOBO H22 series loggers). Inside this package 2 wire nuts Specification S-UCC-M006 for Electronic Switches S-UCD-M006 for Contact Closures Maximum Input Frequency 120 Hz (120 pulses per second) 2 Hz (2 pulses per second) Measurement Range 0 65,533 pulses per logging interval Resolution 1 pulse Lockout time 45 µs ± 10% 327 ms ± 10% Recommended Input Type Electronic solid state switch closure or CMOS-level digital output (example: FET, opto-fet or open collector) Mechanical contact closure (example: reed switch in a tipping-bucket rain gauge) Preferred Switch State Active low input Normally open Edge Detection Falling edge, Schmitt Trigger buffer (logic levels: low 0.6 V, high 2.7 V) Minimum Pulse Width 1 ms Input/Output Impedance 100 KΩ Open Circuit Input Voltage 3.3 V Maximum Input Voltage 3.6 V User Connection 24 AWG wires, 2 leads: white(+), black(-) Operating Temperature -40 to 75 C (-40 to 167 F) Range Overall Cable Length 6.5 m (21 ft.) Housing Weatherproof PVC housing protects input adapter electronics Housing Dimensions 14 x 0.95 cm (5.5 x 0.375 in.) Weight 310 g (11 oz.) Bits per Sample 16 Number of Data Channels 1 Measurement Averaging No (reports the number of pulses over the logging interval) Option Part Number S-UCC-M006 S-UCD-M006 For maximum battery life, the s should be used with their preferred switch type. The adapters will work with active high inputs (S-UCC) and normally closed switches (S-UCD), but battery life will not be optimized. 2007 Onset Computer Corporation Part #: MAN-S-UCC/D Doc #: 11805-A

s Using the with the H21-001 HOBO Weather Station or H21-002 HOBO Micro Station Connecting the Input Adapter Typical Setup The adapter housing should be installed outside the logger enclosure. Be sure to follow the instructions included with the logger to ensure that the logger is properly sealed where the sensor cable exits the logger enclosure. Secure the adapter housing to the mast or sensor mounting arm. Excess cable should be coiled and secured with cable ties. When making a connection to a third-party sensor, take time to make sure that the connection is reliable. The connection should be protected from rain, dirt, and direct exposure to the elements. The input cable can be connected directly to screw terminals on the sensor or to sensor cables with the included wire nuts. To use the wire nuts, strip about 1 cm (3/8") of insulation from the end of wires, taking care not to nick the metal conductors. Then, twist the stripped wires together clockwise and then screw on the wire nut clockwise. Check the connection by gently pulling on the wires to verify a solid mechanical connection. Always strain-relief the connection to make sure that the connection is not broken by being jerked or repeatedly worked back and forth. Installation Considerations If sensor cables are left on the ground, use a conduit to protect against animals, lawn mowers, exposure to chemicals, etc. Refer to the HOBO Weather Station User s Guide or the HOBO Micro Station User s Guide for information about setting up complete stations. Input Connections The sensor has two input connections. The white wire (+) is powered at 3.3 V through a 100 KΩ resistor. This power is supplied from the logger s battery. The black wire (-) is connected through the adapter to the logger s ground connection. Typical Setup of S-UCD-M006 with a Tipping Bucket Rain Gauge or Mechanical Contact Switch The Contact Closure (S-UCD-M006) is designed to work with Tipping-Bucket Rain Gauges and other devices with normally open, mechanical contact closure, switched outputs with a maximum pulse frequency of 2 Hz. This sensor has a pre-set lockout time of 327 ms and is designed to work with signals that must be de-bounced to be accurately measured. Note Bounce is a phenomenon where a single pulse may contain several false pulses or bounces. De-bouncing a signal is typically required when measuring signals from mechanical switches, contact closures, and reed switches. The lockout time prevents bounce-induced false pulses from being counted as separate switch closures. If your gauge has a counter display and battery, disconnect them and connect the in their place. In most cases, the black and white wires can be connected directly to the relay output. (When connecting to relay or switch contacts, polarity does not matter.) Page 2 of 6

s A typical setup for connecting a sensor with a mechanical switch output is shown below. H21-001 HOBO Weather Station (shown) or H21-002 HOBO Micro Station Device with Mechanical Contact Closure Output (Tipping-Bucket Rain Gauge shown as example) Sensor S-UCD-M006 3.3 Volts 100 K Ohms Normally Open Switch White Black 1 K Ohms Input Port S-UCD-M006 Figure 1: 2 Hz (S-UCD-M006) connected to a device that has a mechanical contact closure output Note The s consume about 1 µa of current with the input high (switch open) and about 33 µa with the input low (switch closed). For maximum logger battery life, use the Pulse Input Adapters with normally open switches or with transducers that are off (circuit open) for 90% of the time or longer. GND Connecting to the Logger To start using the, stop the logger and insert the adapter s modular jack into an available sensor connection port on the logger. If no port is available, use a 1-to-2 sensor connection adapter (Onset Part # S-ADAPT), which allows you to plug two sensors into one port on the HOBO Weather Station only. (The HOBO Weather Station supports a maximum of 15 data channels and 15 sensor ports. The HOBO Micro Station supports a maximum of 15 data channels and 4 sensor ports and cannot be expanded with the 1-to-2 adapters.) The logger automatically detects the new input adapter the next time you launch it. Launch the logger and verify that the is functioning correctly. Refer to the HOBO Weather Station User s Guide for more details about connecting HOBO smart sensors to the HOBO Weather Station. Verifying Functionality To verify proper operation of the, connect the adapter to a logger and launch the logger. With the logger launched, enter a known number of pulses (for example, if using a tipping-bucket rain gauge, tip the bucket several times). Then read out the logger and verify that the number of pulses in the data file is correct. If you think that the is not capturing pulses, check the connections to the adapter and verify that the device being measured is functioning normally. If you believe the adapter is not working properly, you can send the adapter back to Onset for repair. Contact Onset or your Onset Authorized Dealer for a Return Merchandise Authorization (RMA) number. Page 3 of 6

s Using the with the H22-001 HOBO Energy Logger Pro TM Connecting the Input Adapter Typical Setup When making a connection to a third-party sensor, take time to make sure that the connection is reliable. Note: Third-part sensors purchased from Onset, such as WattNode or Veris pulse output kwh transducers, are supplied with documentation that provides additional information for system configuration. To use the included wire nuts, strip about 1 cm (3/8") of insulation from the end of wires, taking care not to nick the metal conductors. Then, twist the stripped wires together clockwise and then screw on the wire nut clockwise. Check the connection by gently pulling on the wires to verify a solid mechanical connection. Always strain-relief the connection to make sure that the connection is not broken by being jerked or repeatedly worked back and forth. Input Connections The sensor has two input connections. The white wire (+) is powered at 3.3 V through a 100 KΩ resistor. This power is supplied from the logger s battery. The black wire (-) is connected through the adapter to the logger s ground connection. Typical Setup of S-UCC-M006 with a FET Switch Transducer The 120 Hz (S-UCC-M006) is designed for devices with a normally open solid-state switch, FET switch or open collector, with a maximum pulse frequency of 120 Hz. This input adapter will not work with sensors that have mechanical switch outputs, AC outputs, or outputs that must be debounced (see previous section). A typical setup of a FET switch transducer is shown below. H22-001 HOBO Energy Logger Pro Device with FET Switch Output (Pulse Output Kwh Transducer shown as example) S-UCC-M006 3.3 Volts Transducer Pulse Output FET White 100 K Ohms 1 K Ohms Input Port Black S-UCC-M006 Figure 2: 120 Hz (S-UCC-M006) connected to a device that has a FET switch output Note The s consume about 1 µa of current with the input high (switch open) and about 33 µa with the input low (switch closed). For maximum logger battery life, use the Pulse Input Adapters with normally open switches or with transducers that are off (circuit open) for 90% of the time or longer. GND Page 4 of 6

s Connecting to the Logger To start using the, stop the logger and insert the adapter s modular jack into an available sensor connection port on the logger. If no port is available, use a 1-to-2 sensor connection adapter (Onset Part # S-ADAPT-5), which allows you to plug two sensors into one port on the HOBO Energy Logger Pro. The HOBO Energy Logger Pro supports a maximum of 15 data channels. The logger automatically detects the new input adapter the next time you launch it. Launch the logger and verify that the is functioning correctly. Refer to the HOBO Energy Logger Pro User s Guide for more details about connecting HOBO smart sensors to the HOBO Energy Logger Pro. Verifying Functionality To verify proper operation of the, connect the adapter to a logger and launch the logger. If you think that the is not capturing pulses, check the connections to the adapter and verify that the device being measured is functioning normally. If you believe the adapter is not working properly, you can send the adapter back to Onset for repair. Contact Onset or your Onset Authorized Dealer for a Return Merchandise Authorization (RMA) number. Page 5 of 6

s Warranty This product is warranted to be free from defects in material and workmanship for a period of one year from the date of original purchase. During the warranty period, Onset will, at its option, either repair or replace products that prove to be defective. This warranty is void if the Onset products have been damaged by customer error or negligence, or if there has been an unauthorized modification. Tune-up Service Onset will examine and retest this or any other smart sensor or input adapter. A tune up fee may be charged. 2007 Onset Computer Corporation. All rights reserved. Onset and HOBO are registered trademarks and Energy Logger Pro is a trademark of Onset Computer Corporation. Other products and brand names may be trademarks or registered trademarks of their respective owners. Part #: MAN-S-UCC/D Document #: 11805-A Page 6 of 6