Your Global Automation Partner. IM Interface Technology in Modular Housings

Similar documents
Interface technology. Interface technolog. Interface technology INTERFACE TECHNOLOGY. Sense it! Connect it! Bus it! Solve it!

Sense it! Connect it! Bus it! Solve it! INTERFACE TECHNOLOGY

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

APPLICATION GUIDE. Interface Modules IM Series.

Your Global Automation Partner. excom I/O System

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Temperature Converters

Inductive sensor BI1.5-EG08-Y1-H1341

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive sensor NI3-EG08K-Y1-H1341

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Sense it! Connect it! Bus it! Solve it! Temperature measurement

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

excom Remote-I/O system Short Description

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Analog Output Isolators

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Fieldbus I/O module PROFIBUS-DP 16 configurable digital channels, as PNP inputs or 2 A outputs TBDP-L2-16DXP

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

CPU module for zone 2 Series 9442/35

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Signal conditioners with Functional Safety The MACX ranges

Sense it! Connect it! Bus it! Solve it! REMOTE I/O excom

Intrinsically Safe Barriers

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Your Global Automation Partner. Temperature Sensors Industrial Temperature Measurement in Fluids and Gases

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Compact multiprotocol I/O module for Ethernet 16 digital pnp inputs FGEN-IM

Safety manual. This safety manual is valid for the following product versions: Version No. V1R0

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

5 Fieldbus Technology

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Intrinsically Safe Remote I/O System

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Inductive sensor BI1.5-EG08-Y1-H1341

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs 8 digital outputs 2 A FGEN-IOM

SITOP in the SIMATIC Design

Compact multiprotocol I/O module for Ethernet 16 configurable digital channels pnp inputs / outputs 2 A FGEN-XSG

Ethernet spanner Master to master data exchange, NAT router, 16 digital PNP inputs TBEN-LG-EN1

TBEN-S Multiprotocol Module for Ethernet Compact RFID and I/O module TBEN-S2-2RFID-4DXP

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

S900 Remote I/O System Intrinsic safety in the field ABB

PROFIBUS-PA Positioner Type 3785

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

Ethernet Spanner Master to master data exchange, NAT router, 16 digital PNP inputs TBEN-L5-EN1

BL compact Multiprotocol Station for Industrial Ethernet 16 Digital PNP Inputs BLCEN-16M8LT-8DI-P-8DI-P

REMOTE I/O excom F 395/08

Compact multiprotocol I/O module for Ethernet 8 Digital PNP Inputs and 8 Digital PNP Outputs 2 A TBEN-LG-8DIP-8DOP

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Profibus-DPV1 Set in IP20 TI-BL20-DPV1-2

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

TBEN-L Multiprotocol Module for Ethernet Compact RFID and I/O Module Programmable via CODESYS V3 with WebVisu License TBEN-L5-4RFID-8DXP-CDS-WV

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs, input diagnostics per channel TBEN-S1-8DIP-D

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Compact multiprotocol I/O module for Ethernet 8 universal digital channels, configurable as PNP inputs or 0.5 A outputs TBEN-S1-8DXP

Digital Positioner 8049

Compact multiprotocol I/O module for Ethernet 16 digital PNP outputs TBEN-L1-16DOP

Rotary Measurement Technology Absolute Encoders, Singleturn

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

Compact multiprotocol I/O module for Ethernet 16 digital PNP inputs TBEN-L1-16DIP

Flow monitoring For the connection of intrinsically safe flow sensors IO-Link device with relay outputs FMX-IM-3UR38X

Compact multiprotocol I/O module for Ethernet 8 Digital PNP Inputs and 8 Digital PNP Outputs 2 A TBEN-L1-8DIP-8DOP

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Technical Data. General specifications. Rated operating distance s n 3 mm

BL67 electronic module 4 analog inputs for current/voltage BL67-4AI-V/I

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Compact multiprotocol I/O module for Ethernet 16 Universal Digital Channels, Configurable as PNP Inputs or 2A Outputs TBEN-L1-16DXP

Compact Multiprotocol I/O Module for Ethernet 16 Universal Digital Channels, Configurable as NPN Inputs or 2 A Outputs TBEN-L4-16DXN

Compact Multiprotocol I/O Module for Ethernet 16 digital NPN Inputs TBEN-L4-16DIN

Inductive sensor BI5-EM18-Y1X-H1141

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

DeltaV Bulk Power Supplies

PI-EX-ME-2NAM/COC-24VDC

Compact Multiprotocol I/O Module for Ethernet 16 Digital PNP Outputs TBEN-L4-16DOP

Compact multiprotocol I/O module for Ethernet 16 digital outputs 2 A FGEN-OM

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL September/2016 VTT10-PH. HART TEMPERATURE TRANSMITTER panel model

Transcription:

Your Global Automation Partner IM Interface Technology in Modular Housings

Interface Technology in Modular Housings IM Series Functions and selection guide 10 11 12 7 8 9 16 17 18 19 20 11 12 13 14 15 10 11 12 7 8 9 Pwr 1 2 104 89 NO 1 off off NO 2 off off NC WB SC NC WB SC IM... 4 5 6 1 2 3 IM... 6 7 8 9 10 1 2 3 4 5 IM1-22Ex-R 230VAC 4 5 6 1 2 3 110 27 The housing concept Depending on the device s scope of functions, there are housings with a width of 18 or 27 mm, while they are 104 mm high. All modules may be mounted directly next to each other and can be powered via the power bus. Universal power supply With a universal power supply ranging from 20 250 VUC, or / for the intrinsically safe versions, the new IM-modules may be connected to practically all industrial power networks. The universal power supply facilitates device selection, as well as device and spare parts inventory management. Removable terminal blocks Removable terminal blocks simplify installation and device replacements significantly. The terminals are coded, thus preventing interchange errors. ATEX compliance All interface devices of the IM series feature intrinsically safe input and output circuits and are approved according to the new framework directive 94/9/EC, regarding equipment and protective systems intended for use in potentially explosive atmospheres. They can thus be used as associated equipment. The blue terminals are designated for connection of intrinsically safe signals. Further information on the ATEX directive is available via the Internet: http://ec.europa. eu/enterprise/atex/guide/index.htm Hans Turck GmbH & Co. KG 45466 Mülheim an der Ruhr, Germany T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com

U EN 60947-5-6 I Isolating s Processing of switching states of mechanical and sensors according to EN 60947-5-6 (NAMUR). (Page 4) Rotational speed monitors/frequency-current converters Rotation speed monitoring for overspeed/underspeed and window function, operating range between 0.06 600000/min (Page 5) Analog data s/intrinsically safe input isolators Galvanic isolation and/or conversion of analog current and voltage signals. There are devices with intrinsically safe input and output circuits. (Page 6) J P I HART P I HART Isolating transducers Supply and transmission of current signals of 2-wire s located in explosion hazardous areas. HART devices enable bi-directional communication. This range incorporates devices with and without auxiliary power and active or passive outputs. Series-FSD includes smoke and fire detectors. (Page 7) Temperature measuring s Linear conversion of temperature values into standard current signals. Linear conversion of temperature values, which are detected by a thermo-element, into standard current signals. All customary thermo-elements or mv-signals may be connected. Types -Ci, -CRi = programmable via PC using software PACTware. (Page 8) Analog data s/intrinsically safe output isolators Galvanic isolation and transfer of analog current signals into the explosion hazardous area. The family comprises a selection of devices with intrinsically safe output circuits. HART devices enable bi-directional communication. (Page 9) Potentiometer s Conversion of the variable resistance values of a potentiometer into standard current and voltage signals. The input circuit is intrinsically safe, so that the potentiometer may be mounted in the explosion hazardous area. (Page 10) Limit value monitors Monitoring of standard current and voltage signals relative to preset limit values. This series includes devices with three limit values and versions with current output. Types -SR, -SRi feature a manual teach function, whereas types -R and -Ri are adjustable via a coded rotary switch. (Page 11) Valve control modules Intrinsically safe supply of magnetic valves, pilot indicators, s etc. (Page 12) Coupling devices Galvanically isolated transmission of binary switching states. These devices function as a reliable interface between different potentials. (Page 13) Power supplies Power supply with galvanic isolation used to power low power consumers, particularly suited for powering the switching and monitoring devices of Turck s interfacemodul, multimodul und multisafe series. (Page 14) 1 2... 31 32 2000 45 Programming adapter For programming the IM-modules via a PC. Power-bus for power distribution Distribution of the power supply to several modules. xx in the type code stands for the number of modules, 03 for 3-pole terminals. Cage-clamp terminals Removable cage-clamp terminals (3/5-pole) for IM modules. 2015 11 2 3

Type IM1-12Ex-R IM1-12Ex-T IM1-12-T IM1-22Ex-R IM1-22-R IM1-22Ex-T [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] Function Voltage supply Inputs 1 Namur sensor or 1 Namur sensor or Outputs 2 x relays (N.O.) 2 transistors 30 V, 50 ma, 5 KHz Approvals Special features ATEX, IECEx, UL, cfmus, CSA,, NEPSI, KOSHA, TIIS, CCOE SIL 2, mounting in zone 2 ATEX, IECEx, UL, FMus, CSA,, NEPSI, KOSHA, TIIS, CCOE SIL 2, mounting in zone 2 1 Namur sensor or 2 Namur sensors or 2 Namur sensors or 2 NAMUR sensors or 2 x transistors 2 x relays (N.O.) 2 x relays (N.O.) 2 x transistors 30 V, 50 ma, 5 KHz SIL 2 ATEX, IECEx, UL, cfmus, CSA,, NEPSI, KOSHA, TIIS, CCOE SIL 2, mounting in zone 2 SIL 2 ATEX, IECEx, UL, cfmus, CSA,, NEPSI, KOSHA, TIIS, CCOE SIL 2, mounting in zone 2 Isolating s EN 60947-5-6 Evaluation and processing of switching states of mechanical and sensors according to EN 60947-5-6 (NAMUR). Hans Turck GmbH & Co. KG 45466 Mülheim an der Ruhr, Germany T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com

IM1-22Ex-MT IM1-121Ex-R IM1-231Ex-R IM1-451Ex-R IM1-451-R IM1-451Ex-T [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] 20...250 VAC 20...125 VDC 250 VUC 2 Namur sensors or 1 Namur sensor or 2 Namur sensors or 4 NAMUR sensors or 4 NAMUR sensors or 4 Namur sensors or 2 MOSFETS 250 VAC 2 relays (N.O.) incl. 1 alarm output 2 relays (change-over) additionally 1 alarm output (N.O.) 5 Relais (N.O.) incl. 1 alarm output 5 Relais (N.O.) incl. 1 alarm output 5 transistors, incl. 1 alarm output CSA,, NEPSI, KOSHA, TIIS, CCOE CSA,, NEPSI, KOSHA, TIIS, CCOE ATEX, IECEx,, INMETRO CSA,, INMETRO, TIIS CSA,,INMETRO, TIIS SIL 2, mounting in zone 2 [ Ex ia ] Speed monitors/frequency-current converters Selectable line monitoring for wirebreak/short-circuit (ON/OFF mode), galvanic isolation of input circuits, output circuits and supply voltage, rotation speed monitoring for overspeed/underspeed and window function, operating range between 0.06 600000/min, sensor control acc. to EN 60947-5-6 (NAMUR), connection of 3-wire sensors and external voltage sources 5 30 VDC, 2 relay and one transistor output, pulse divider, current output 0/4 20 ma, reversible, pulse output, adjustable analog output in case of input circuit errors FDT/DTM with diagnostic function HART, ring buffer for storing of measured values, removable terminal blocks, universal operating voltage (/ for Ex-version, 20 250 VUC for non-ex-version). 2015 11 4 5

Type IM1-451-T IM12-22Ex-R IM12-22ExR/24VDC IM12-22ExR-230VAC IM21-14Ex-CDTRi IM21-14-CDTRi Function Voltage supply Inputs Outputs 20 250VAC 20 250VDC 4 NAMUR sensors or 5 transistors, incl. 1 alarm output [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] 2 NAMUR sensors or Approvals ATEX, IECEx, UL, cfmus, CSA,, NEPSI, KOSHA, TIIS, CCOE Special features Speed monitor/freq.- current converter 10 30 VDC 196 253 VAC 2 NAMUR sensors or 2 NAMUR sensors or 2 x relays (N.O.) 2 x relays (N.O.) 2 x relays (N.O.) 2 x relays (N.O.) 1 transistor 1 x 0/4 20 ma ATEX, cfmus, ATEX, cfmus, ATEX, IECEx, cfmus,, NEPSI, TIIS, KOSHA Signal multiplier Signal multiplier Display, programmable via PC (FDT/DTM), Speed monitor/freq.- current converter 250 VUC 1 NAMUR 1 Namur or 3-wire sensors, 5 30 VDC 2 x relays (N.O.) 1 transistor 1 x 0/4 20 ma Display, programmable via PC (FDT/DTM) U I Analog data s/intrinsically safe input isolators Galvanic isolation and/or conversion of analog current and voltage signals. There are devices with intrinsically safe input and output circuits. Hans Turck GmbH & Co. KG 45466 Mülheim an der Ruhr, Germany T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com

IM31-11Ex-i IM31-11-i IM31-12Ex-i IM31-12-i IM31-22Ex-U IM31-22Ex-i IM31-22-i [ Ex ia ] [ Ex ia ] [ Ex ia ] Analog data Analog data Analog data Analog data Analog data Analog data 250 VUC 0/2 10 V 0/4 20 ma 0/2 10 V 0/4 20 ma 0/2 10 V 0/4 20 ma 250 VUC 0/2 10 V 0/4 20 ma 2 x 0/2 10 V 2 x 0/4 20 ma 0/4 20 ma 1 x 0/4 20 ma 2 x 0/4 20 ma 2 x 0/4 20 ma 2 x 0/4 20 ma 2 x 0/2...10 V 250 VUC 2 x 0/2 10 V 2 x 0/4 20 ma 2 x 0/4 20 ma, NEPSI, NEPSI, NEPSI Signal multiplier, Isolating transducers HART These devices are suited for the supply and transmission of current signals of 2-wire s located in explosion hazardous areas. HART devices enable bi-directional communication. This range incorporates devices with and without auxiliary power and active or passive outputs. Series-FSD includes smoke and fire detectors. FDT/DTM with diagnostic function. 2015 11 6 7

Type IM33-11Ex-Hi/24VDC IM33-12Ex-Hi/24VDC IM33-12-Hi/24VDC IM33-22Ex-Hi/24VDC IM33-22-Hi/24VDC IM33-11Ex-Hi Function Voltage supply [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] HART isolating transducer HART isolating transducer HART isolating transducer HART isolating transducer HART isolating transducer HART isolating transducer 24 VDC 24 VDC 19 29 VDC 24 VDC 19 29 VDC Inputs 0/4 20 ma 1 x 0/4 20 ma 1 x 0/4 20 ma 2 x 0/4 20 ma 1 x 0/4 20 ma 1 x 0/4 20 ma Outputs 0/4 20 ma 2 x 0/4 20 ma 2 x 0/4 20 ma 2 x 0/4 20 ma 2 x 0/4 20 ma 1 x 0/4 20 ma Approvals ATEX, IECEx, UL, cfmus,, TIIS, CCEO, KOSHA ATEX, IECEx, UL, cfmus,, TIIS, CCEO, KOSHA ATEX, IECEx, UL, cfmus,, TIIS, CCEO, KOSHA ATEX, IECEx, cfmus,, INMETRO Special features /SIL 2, /SIL 2, /SIL 2, /SIL 2, J Temperature measuring s Linear conversion of temperature values, which are detected by a thermo-element or RTD, into standard current signals. All customary or RTP thermoelements or mv signals may be connected. Types -Ci, -CRi = programmable via PC using software PACTware and FDT/DTM, with diagnostic function, HART transparent Hans Turck GmbH & Co. KG 45466 Mülheim an der Ruhr, Germany T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com

IM33-12Ex-Hi IM33-22Ex-Hi IM33-14Ex-CDRi IM33-FSD-Ex/L IM34-11Ex-i IM34-11Ex-Ci [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] HART isolating transducer HART isolating transducer Transmitter power supply with trip 1 x 0/4 20 ma 2 x 0/4 20 ma 0/4 20 ma oder 0/2 10 V oder 2 x 0/4 20 ma 2 x 0/4 20 ma 1 x 0/4 20 ma, 3 Relais (Schließer) ATEX, IECEx, cfmus, TR CU, INMETRO ATEX, IECEx, cfmus, TR CU, INMETRO ATEX, IECEx, Isolating transducer Without auxiliary energy Temperature measuring 2 x 0 20 ma Ni/Pt100 or thermo-elements or mv-input Temperature measuring Ni/Pt100 or thermo-elements or mv-input 2 x 0 20 ma 1 x 0/4 20 ma 1 x 0/4 20 ma ATEX, cfmus, ATEX, IECEx, cfmus, UL,, INMETRO, CCOE ATEX, IECEx, cfmus, UL,, INMETRO, CCOE /SIL 2, mounting in zone 2 /SIL 2, mounting in zone 2 Display, programmable via PC (FDT/DTM), Transducer for fire and smoke indicators Programmable via PC (FDT/DTM), mounting in zone 2 P I P I HART Analog data s/intrinsically safe output isolators Galvanic isolation and transfer of analog current signals into the explosion hazardous area. The family comprises a selection of devices with intrinsically safe output circuits. HART devices enable bi-directional communication. 2015 11 8 9

Type IM34-11Ex-Ci/24VDC IM34-11-Ci IM34-12Ex-Ri IM34-12Ex-CRi IM34-14Ex-CDRi IM35-11Ex-Hi/24VDC [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] Function Temperature measuring Temperature measuring Temperature measuring Temperature measuring Temperature measuring HART Analog data Voltage supply 20 30 VDC 24 VDC Inputs Ni/Pt100 or thermo-elements or mv-input Ni/Pt100 or thermo-elements or mv-input Ni/Pt100 or thermo-elements or mv-input Ni/Pt100 or thermoelements or mv-input Ni/Pt100 or thermoelements or mv-input 0/4 20 ma Outputs 1 x 0/4 20 ma 1 x 0/4 20 ma 1 x 0/4 20 ma, 1 relays (N.O.) 1 x 0/4 20 ma, 1 relays (N.O.) 3 relays (N.O.) 1 x 0/4 20 ma) 0/4 20 ma Approvals ATEX, IECEx,, INMETRO, CCOE ATEX, IECEx, cfmus, UL,, INMETRO, CCOE ATEX, IECEx, cfmus, UL,, INMETRO, CCOE ATEX, IECEx, cfmus, TIIS, KOSHA ATEX, IECEx, UL, cfmus, Special features Programmable via PC (FDT/DTM), mounting in zone 2 Display, programmable via PC (FDT/DTM),, mounting in zone 2 Potentiometer s Conversion of the variable resistance values of a potentiometer into standard current and voltage signals. The input circuit is intrinsically safe, so that the potentiometer may be mounted in the explosion hazardous area. Hans Turck GmbH & Co. KG 45466 Mülheim an der Ruhr, Germany T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com

IM35-11-Hi/24VDC IM35-11Ex-Hi IM35-22Ex-Hi/24VDC IM35-22Ex-Hi IM36-22Ex-I IM36-11Ex-i/24VDC HART Analog data [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] [ Ex ia ] HART Analog data 24 VDC HART Analog data r HART Analog data 24 VDC Potentiometer Potentiometer 0/4 20 ma 1 x 0/4 20 ma 2 x 0/4 20 ma 2 x 0/4 20 ma 800 Ω bis 100 kω 800 Ω bis 20 kω 24 VDC 0/4 20 ma 1 x 0/4 20 ma 2 x 0/4 20 ma 2 x 0/4 20 ma 0 20 ma 0 20 ma ATEX, ATEX, ATEX, IECEx, ATEX,, mounting in zone 2 /SIL 2, mounting in zone 2, mounting in zone 2 Limit value monitors Monitoring of standard current and voltage signals relative to pre-set limit values. This series includes devices with three limit values and versions with current output. Types -SR and -SRi = a manual teach function, Types -R and -Ri = adjustable via a coded rotary switch Typ -CDRi: programmable via FDT/DTM with diagnostic function HART transparent 2015 11 10 11

Type IM36-22Ex-U IM36-11Ex-U/24VDC IM43-13-R IM43-13-SR IM43-14-Ri IM43-14-CDRi Function Voltage supply [ Ex ia ] [ Ex ia ] Potentiometer Potentiometer Inputs 800 Ω bis 100 kω 800 Ω bis 20 kω 0/4 20 ma or 0/2 10 V or Limit value monitor Limit value monitor Limit value monitor Limit value monitor 24 VDC 20 250 VUC 20 250 VUC 20 250 VUC 20 250 VUC 0/4 20 ma or 0/2 10 V or 0/4 20 ma or 0/2 10 V or Outputs 0 10 V 0 10 V 3 relays (N.O.) 3 relays (N.O.) 3 relays (N.O.), 1 x 0/4 20 ma Approvals ATEX, IECEx, ATEX, cfmus, cfmus, cfmus, 0/4 20 ma or 0/2 10 V or 3 relays (N.O.) 1 x 0/4 20 ma Special features Setting of limit values via rotary coding switch Manual teach function Setting of limit values via rotary coding switch Display, programmable via PC (FDT/DTM Valve control modules Intrinsically safe supply of magnetic valves, pilot indicators, s etc. Hans Turck GmbH & Co. KG 45466 Mülheim an der Ruhr, Germany T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com

IM72-11Ex/L-24VDC IM72-22Ex/L-VDC IM73-12-R IM73-22Ex-R/24VUC [ Ex ia ] [ Ex ia ] [ Ex ia ] Valve control module Valve control module Relay coupler Relay coupler Without power supply Without power supply Without auxiliary energy 10 30 VUC 19 30 V 19 30 V 19 30 V 24 VUC 230 VAC 2 x 10 30 VUC 24 V/45 ma 15 V/45 ma KOSHA,, NEPSI, INMETRO SIL 3, Loop-powered, 24 V/45 ma 15 V/45 ma KOSHA,, NEPSI, INMETRO SIL 3, Loop-powered, 2 Relais (Wechsler) 2 Relais (Wechsler) ATEX, SIL 3 Coupling devices Galvanically isolated transmission of binary switching states. These devices function as a reliable interface between different potentials. 2015 11 12 13

Typ IM82-24-2,5 IM82-24-5,0 IM82-24-10 IM82-24-20 Function Power supply Power supply Power supply Power supply Voltage supply 85 264 VAC, 90 375 VDC 90 132 VAC, 186 264 VAC, 210 370 VDC 90 132 VAC, 186 264 VAC, 210 370 VDC Outputs 24 V/2,5 A 24 V/5 A 24 V/10 A 24 V/20 A Approvals UL UL UL 90 264 VAC, 120 370 VDC Special features Class 1 Div 2 Class 1 Div 2 Class 1 Div 2 Power supplies The IM82-24 switching power supplies provide safety extra-low voltage (SELV) acc. to EN 60950. They supply electrical equipment as well as IM, IME, IMS and IMC interface modules with 24 VDC. Hans Turck GmbH & Co. KG 45466 Mülheim an der Ruhr, Germany T +49 208 4952-0 F +49 208 4952-264 more@turck.com www.turck.com

IM82-24-5,0-3P IM82-24-10-3P 3-phase power supply 3-phase power supply 340 575 VAC, 480 820 VDC 340 575 VAC, 480 820 VDC 24 V/5 A 24 V/10 A UL Class 1 Div 2 UL Class 1 Div 2 2015 11 14 15

28 subsidiaries and over 60 representations worldwide! D200586 2015/11 *D200586ßß1511* www.turck.com