CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

Similar documents
RB24 Relay Box Installation Guide For use in low voltage motorized window and skylight systems

QUASAR Installation & Maintenance Guide motorized actuator for windows and skylights

Home Automation Systems Installation Guide for FFI Actuator & Control Projects

Stand Alone Actuator Systems

ACTUATOR. Terminal Blocks. Terminal Blocks. motor. motor. input 24 VDC. input 24 VDC. input 24 VDC RQ60DUM RQ60DUM. Control Circuit.

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Model HM-535 Power Supply Installation and Service Instructions

SOLARIMMERSION IV Advanced Installation Manual v1.9

S82S (3/7.5-W Models)

User's Guide. Model High Precision Quad Output DC Power Supply

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

Digital Lighting Systems, Inc.

RELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS

Ultra Slim Relays 24

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Ambient Weather WM-3 Handheld Wind Meter with Temperature and Humidity User Manual

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RТTH DUAL ROOM SWITCH

User's Guide. Model W 3-in-1 Switching DC Power Supply

Operating instructions. Switching amplifier DN0210 DN / / 2015

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Installation Instructions

Conductive Level Controller

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Operating instructions. Speed monitor D / / 2014

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

AirTest Model CN9000 Series Sensor Controller

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

MTP INSTRUCTION MANUAL

1-36V, 0-3A DC Power Supply

INSTALLATION AND MOUNTING MANUAL

OZONE SWITCH Model OS-6. OS-6 Features

CMSA-100 Manual. Cinema Media Server Automation

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

NJ-Series Power Supply Unit NJ-PA/PD

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

SP6R Level Controller Operation Manual

Tempco Instruction Manual

INSTRUCTION MANUAL A START-UP AND SHUT DOWN LOAD SEQUENCER AND AUTOMATIC LOAD SHEDDING SYSTEM WITH INTEGRAL RELAYS FOR 8 LOADS MODEL #091-60A

Z-350 FAZER USER MANUAL

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

MAXIMA+ Series Rotary Level Indicator

Model Number Structure

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

MAXIMA + Series ROTARY LEVEL CONTROL

PRODUCT SPECIFICATION. PC Board Relays. Series.

MICRO GROW GREENHOUSE SYSTEMS, INC

YJ Carat and Gold Scales

User's Guide. Extech AM A AC Analog Clamp Meter

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

Thank you for your purchase of the Supa-Charger! Features Include:

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Number of input channels

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Evolution Variable Output. With Override Pot. Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033

Z-380 Fazer Machine User Manual English

DCM Digital Control Modules

Owner s Instruction Manual

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

RAINPROOF* COLOR CAMERA SECURITY SYSTEM

Installation, Operation and Maintenance Manual

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

I/O Expansion Box Installation & Operator s Instruction Manual

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

AC 3000 Digital Camera AC/DC Power Adapter

2-Way Wireless I/O Expander Installation Guide

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

NX8 Pocket Toner Users Guide

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

SLA Battery Capacity Analyzer

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Motorized Curtain Tracks Progress 50 Motor Set

AD-7830 Servo Amplifier

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

What s in the Box? REAR VIEW SAFETY

DVI ELR Extender over one CAT5

DVI ELR Extender over one CAT5

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3

4170 POS System Installation Guide

700 Series 200 Amp Clamp Meters

Basketball Shot Clock Set LX2180 Manual

Robot Light V2. User Manual

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

Manual Control Unit GFC 32

Transcription:

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional relay box or power supply is not needed, unless use exceeds CRM capacity (4 amp for CRM3 for DC actuators; 7 amps for CRM4 for AC actuators). Use CRM to add Remote Control option to actuator(s). Use CRM to add Weather Sensor option(s) to actuators. Recommendations for FFI Actuators & Controls: FFI only recommends UL compliant systems. FFI is a UL registered firm. Read FFI data sheets & installation guides before specifying project details. Project-specific needs vary depending on the number of actuators, electrical layouts, building management systems, distance between power supplies & actuators, and other details. Project specifications to comply with electric & building codes for wire gauge, wire connections and run distance, conduits, junction boxes must be arranged by the project electrical contractors. Distribute this guide to all project parties, including electrical contractors, architects, and building management personnel. 29-Oct-13 800-677-0228 www.fenestration.net page 1 of 11

CRM Specifications CRM3 for DC actuators part # 40821J CRM4 for AC actuators part # 40822K Supply Voltage 115 Vac ± 10%, 60 Hz (line voltage) 115 Vac ± 10%, 60 Hz (line voltage) Total output (all 4 groups)* 4 amps @ 24 Vdc 7 amps @ 115 Vac Power Cable 2 wires (polarity inversion) 4 wires (Open, Close, Common, Ground) Safety Marks CE rated, not UL-Recognized CE rated, not UL-Recognized Operating environment 14 to 140 F (-10 to 60 C) 14 to 140 F (-10 to 60 C) Max. Relative Humidity 60% 60% Case Dimensions 7-13/16 x 5-11/16 x 3-1/8 7-13/16 x 5-11/16 x 3-1/8 * FFI recommends do not exceed 80% of maximum amp capacity for control panels. Attention: Prior to installation it is essential to read these safety notices, warnings and installation instructions. SAFETY NOTICES (1) Read this guide carefully prior to installation. (2) After installation keep these instructions for later review. (3) Incorrect application or improper installation may result in system malfunction and/or damage to people or property. (4) To avoid electrocution when the CRM s cover is removed, check that the CRM is disconnected from the power circuit prior to making electrical connections at its internal terminals, or performing any other operation. (5) It is recommended that the CRM be connected to a dedicated power circuit. (6) Installation must be done by licensed electricians and/or engineers. (7) Prior to installation make sure that: a) The existing electrical system complies with local building codes and regulations. b) The power supply is compatible with the CRM s specifications. WARNINGS (1) Do not attempt to repair the CRM Control Panel. In case of malfunction, contact FFI Customer Service at 800-677-0228 or service@fenestration.net for instructions. For defect claims, FFI must inspect the component. The two-year warranty is provided by Ultraflex Control Systems (UCS). (2) CRM control panel, keyboard, remote control, and thermostat are for indoor use only, and not recommended for high humidity areas, such as greenhouses. Naturally, the rain and wind detectors can be installed outdoors. (3) To be covered by the Warranty, UCS actuators must be used together with UCS-approved accessories (such as power supplies, control panels, control boxes, relay boxes, weather detectors, switches, etc.) MANUFACTURER S LIMITED WARRANTY Ultraflex Control Systems S.r.l. (UCS) products are guaranteed against defects in material and workmanship for a period of two years from the date of manufacture. Alleged defective products returned, freight prepaid, within the warranty period will be repaired or replaced free of charge, at UCS s option, if found effectively below UCS quality standards. This guarantee does not cover other claims for direct or indirect damages. In particular, UCS declines liability and excludes guarantee (except for what is stated above) if improper installation or misuse should result in a failure of UCS products. UCS motors should be used together with UCS-approved accessories. Substitutions must meet UCS specifications. Functional Fenestration Inc. (FFI) will honor the manufacturer s limited warranty (stated above) for two years from the date of sale listed on FFI s invoice. 29-Oct-13 800-677-0228 www.fenestration.net page 2 of 11

FFI TERMS Liability of Functional Fenestration Inc (FFI), Hawthorne, CA, as the seller for any defective product is limited to the replacement or credit of FFI product at original cost, and shall not include damages of any kind, whether incidental, consequential or otherwise. Any claim and return must be made in accordance with FFI Terms and Conditions. CORRECT DISPOSAL OF THIS PRODUCT Responsible disposal of this and other electronic products will help prevent potential negative consequences for the environment and human health. Its aluminum case and other re-usable elements should be re-cycled. INSTALLATION INSTRUCTIONS These instructions refer to the installation and sample wiring diagrams on the following pages. Installation Overview and Preparation The physical dimensions of the CRM3/CRM4 Control Panel are shown in the diagram Control Panel Dimensions. The CRM3, 24 Vdc Control Panel, part# 40821J can deliver power directly to low voltage actuators; or it can serve as a switch for multiple RB24 Relay Boxes, which deliver power to low voltage actuators, as shown in sample diagrams on the following pages. It allows independent control of 1 to 4 actuator groups via output terminals M1-M4, subject to a maximum current draw of 4 amps on any combination of the 4 terminals. Its input power requirement is a line voltage connection, 115 Vac, 60Hz. A back-up power source can be connected at the JP4 terminal within the CRM case. The CRM4, 115 Vac Control Panel, part# 40822K delivers power directly to line voltage actuators. It allows independent control of 1 to 4 actuator groups via its output terminals M1-M4, subject to a maximum current draw of 7 amps on any combination of the 4 terminals. Its input power requirement is a line voltage connection, 115 Vac, 60Hz. A back-up power source can be connected at the JP4 terminal within the CRM case. The Control Panel s four actuator groups start up sequentially to eliminate the risk of excess current draw. The Control Panel can receive commands from the optional control accessories shown in the table below. Signals from these accessories cause an alarm state within the Control Panel, and thereby cause the actuators to close the windows. Alarm State 1 persists for a minimum of 8 minutes, during which the windows cannot be opened via the Keypad, Momentary Switch or External Control System unless the rain and wind sensors are disabled. Control Accessory Alarm State Alarm State Enable/Disable Switch Seniority Minimum Duration Rain sensor 1 8 minutes External switch on Control Panel Wind detector 1 8 minutes External switch on Control Panel Thermostat 2 3 minutes External switch on Thermostat Push-button Keypad 3 3 minutes Not Applicable Infra-red Remote Control 3 3 minutes Not Applicable Momentary contact switch or other external control system 3 3 minutes Not Applicable 29-Oct-13 800-677-0228 www.fenestration.net page 3 of 11

Installation Procedure When reading the text below please refer to the sample diagrams on the following pages. Check that the Control Panel s electrical fuses are in place, as shown in diagram Control Panel Fuse Locations. Momentary Contact Switch or External Control System A single pole double throw (SPDT) momentary contact switch or external control system connects to the Control Panel at terminal JP7. The momentary switch delivers the OPEN and CLOSE commands as brief impulse signals (0.5 to 2 seconds duration). The Control Panel then acts on all four actuator groups, as if the command came from a Keypad with all 4 LEDS turned on. Both the Keypad and the Momentary Contact Switch can be connected to the Control Panel. For Wall Switch (Momentary Contact Switch): - 15 amps max draw per switch; use with DC motors with CRM or relay box. - Dimensions: 4 x 1-1/4 x 1-1/2. Push-Button Keypad Installation (Part # 40770K) The Keypad connects to the Control Panel at terminals JP5 and JP6, as shown in Sample Wiring Diagram B. Multiple keypads can be connected in parallel, as shown in Sample Wiring Diagram C. Dimensions: 3 x 3 x 1-1/2. The Keypad allows independent control of 1 to 4 actuator groups (by means of a serial communication protocol). Use the SELECT button to turn on 1, 2, 3, 4 or all 4 LEDs, which are mounted in the Keypad s cover. Each LED corresponds to actuator groups 1 to 4. After selecting the desired group(s), press the OPEN or CLOSE buttons to activate the actuators. Press the opposite button once to stop the motor. In response to input from the Keypad, the Control Panel delivers power to the actuator group(s) for a 3-minute interval, at which time power is turned off as a safety precaution. The Keypad has an 8-channel infra-red signal detector for receiving commands from the Remote Control. When set to channel 0 (factory setting), the Keypad accepts commands on all frequencies. When set to any of channels 1-7, the Keypad accepts commands only from Remote Controls transmitting commands on that channel. Channel 0 Channel 4 Channel 2 Channel 6 Remote Control Installation (optional, part # 40771L) The Remote Control uses a serial communication protocol and line-of-sight, infra-red light signals to communicate with the Keypad. (Therefore remote must be pointed at the keypad, not at the actuator, to work.) Its effective range is approximately 30 feet. Its buttons resemble the Keypad s buttons and work the same way. The Remote Control requires two 1.5V AAA alkaline batteries (not included). The Remote Control has an 8-channel infra-red signal transmitter for issuing commands to the Keypad. When set to channel 0 (factory setting), the Remote Control issues commands on channel 0. When set to any of channels 1-7, the Remote Control issues commands on that channel only. Dimensions: 4 x 1-13/16 x 1. 29-Oct-13 800-677-0228 www.fenestration.net page 4 of 11

Wind Detector (optional weather sensor, part # 37185V) The wind detector (anemometer) connects to the Control Panel at terminal JP9. It sends the Control Panel a variable signal according to wind intensity. An 8-position selector within the Control Panel sets the threshold for closing the windows. 0 disables the wind detector; positions 1-7 correspond to the Beaufort wind force scale, listed in the table below. One wind sensor can connect with up to six CRM Control Panels. Disable the sensor via the external switch on the Control Panel Case. Dimensions: 4-1/2 x 4 x 4. Intensity Setting for the Wind Detector Selector Position Beaufort Scale Knots Mi/Hr Feet/sec Description 0 0 0 0 0 calm 1 1 1-3 1-3 <7 light air 2 2 4-6 4-7 7-10 light breeze 3 (factory setting) 3 7-10 8-12 11-16 gentle breeze 4 4 11-16 13-18 17-23 moderate breeze 5 5 17-21 19-24 24-33 brisk breeze 6 6 22-27 25-31 34-43 strong breeze 7 7 28-33 32-38 44-53 near gale Wind Intensity Selector (Located in Control Panel) Thermostat (optional weather sensor, part # 40675K) The thermostat has a single threshold setting. When the ambient temperature rises above the threshold, the windows open. When the temperature is below the threshold, the windows close. The rain and wind sensors have priority over the thermostat. To disable sensor, use the external ON/OFF switch on the thermostat s Case. One thermostat can connect with up to six CRM Control Panels. Dimensions: 3 x 3-1/4 x 1-1/2. Rain Sensor (optional weather sensor, part # 40690A) Rain sensor connects to CRM at terminal JP8. One rain sensor can connect to up to six CRM Control Panels. Mount the sensor outside with its copper-colored grid exposed to the sky. Dimensions: 1-1/2 x 2 x 2. The Rain sensor has a heating element to prevent ice from forming on the sensor surface. When choosing a location for the sensor, consider prevailing winds and keep it away from obstructions. Do not run wiring through an opening in a window screen occupied by the actuator s chain, or anywhere near the chain s path. The rain and wind sensors have priority over the thermostat. To disable the sensor, use the external switch on the Control Panel Case. Do not use rain sensor if the actuator is being used for Smoke Ventilation. Plan for routine maintenance to clean the rain sensor. Dirt or debris on the sensor s copper-colored grid can produce alarm states within the Control Panel, which will cause the vents to stay closed even when rain is not present. Clean the sensor surface regularly with a mild soap and water. Rain Sensor sample installation diagrams (generic examples, not project specific): 29-Oct-13 800-677-0228 www.fenestration.net page 5 of 11

Actuator Connections Groups of actuators connect to the Control Panel at output terminals M1, M2, M3 and M4. CRM3 24 Vdc Control Panel, part# 40821J, delivers power directly to DC low voltage actuators; or it can serve as a switch for multiple Relay Boxes, which deliver power to low voltage actuators, as shown in sample diagram on the following pages. It allows independent control of 1 to 4 actuator groups via its output terminals M1-M4, subject to a maximum current draw of 4 amps on any combination of the 4 terminals. Input power required is a line voltage connection, 115 Vac, 60Hz. A back-up power source can be connected at the JP4 terminal within the CRM case. CRM4 115 Vac Control Panel, part# 40822K, delivers power directly to AC line voltage actuators. It allows independent control of 1 to 4 actuator groups via output terminals M1-M4, subject to a maximum current draw of 7 amps on any combination of the 4 terminals. Input power required is a line voltage connection, 115 Vac, 60Hz. A back-up power source can be connected at the JP4 terminal within the CRM case. Control Panel Approx. Dimensions 29-Oct-13 800-677-0228 www.fenestration.net page 6 of 11

Control Panel Fuse Locations Fuse Controls CRM3 CRM4 Part # A Transformer 5x20 5A (fast) 5x20 5A (fast) 58812L B Input & Output Line Voltage 5x20 1A (time delayed) 5x20 1A (time delayed) 82983N C Input & Output Line Voltage None 5x20 6.3A (time delayed) 82982M D Input & Output Line Voltage None 5x20 6.3A (time delayed) 82982M 29-Oct-13 800-677-0228 www.fenestration.net page 7 of 11

Control Panel Internal Sample Wiring Diagram A CONNECTION SPECIFICATIONS SHOWN ARE GENERIC AND NOT PROJECT SPECIFIC. Read FFI actuator and installation guides before specifying and purchasing for automation projects. 29-Oct-13 800-677-0228 www.fenestration.net page 8 of 11

Control Panel Internal Sample Wiring Diagram B CONNECTION SPECIFICATIONS SHOWN ARE GENERIC AND NOT PROJECT SPECIFIC. Example B-1: Using Multiple Keypads with one CRM Example B-2: Using CRM accessories with multiple CRMs Read FFI actuator and installation guides before specifying and purchasing for automation projects. 29-Oct-13 800-677-0228 www.fenestration.net page 9 of 11

CRM Control Panel Installation Guide Control Panel Internal Sample Wiring Diagram C: Control Panel Switching RB24 Relay Boxes CONNECTION SPECIFICATIONS SHOWN ARE GENERIC AND NOT PROJECT SPECIFIC. Read FFI actuator & installation guides before specifying and purchasing for automation projects. 29-Oct-13 800-677-0228 www.fenestration.net page 10 of 11

CRM Control Panel Installation Guide RB24 Relay Box - Internal Connections for 24V DC motors only CONNECTION SPECIFICATIONS SHOWN ARE GENERIC AND NOT PROJECT SPECIFIC. The RB24 Relay Box is a passive device for use in controlling low voltage actuators via its output terminals Motor1 and Motor2, subject to a maximum current draw of 10 amps on each terminal or 20 amps per Relay Box. The Relay Box takes care of reversing the polarity of the output terminals Motor1 and Motor2. A single pole double throw (SPDT) momentary contact switch or external control system connects to the Relay Box at terminal CN6. The momentary switch delivers the OPEN and CLOSE commands as brief impulse signals (0.5 to 2 seconds). The switch operates all actuators connected to the Relay Box. Operation with Jumper In Place (One Touch Switch Operation) Press the switch once and the RB24 powers the actuators for a 3-minute interval, long enough to fully open or close. To stop the motor, press the switch for opposite direction. Operation with Jumper Removed (Press & Hold Switch Operation) Press and hold switch until full OPEN or CLOSE complete. To stop the motor, release the switch. Read FFI actuator and installation guides before specifying and purchasing for automation projects. 29-Oct-13 800-677-0228 www.fenestration.net page 11 of 11