Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Similar documents
Operating manual GTL 142 GTL 152. Temperature probe. Please keep the manual for future use.

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Digital Quick-Response Thermometer

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

GMH Operating Manual for Digital Quick-Response Thermometer

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Manometer. (Over- /Under- And Difference Pressure) Operating Manual GDH

Universal interface adapter for GMSD / GMxD - sensor

Hygro-/Thermometer. Operating Manual GFTH 95

Operating instructions. Standstill monitor A / / 2011

Flow Sensor SONOFLOW CO.55

Operating instructions. Switching amplifier DN0210 DN / / 2015

CMC III Temperature/Humidity Sensor

CMC III Universal Sensor

Programming module and software for Wachendorff panel meters and controller TA/TH/TI/UA/UR/VZ/ZD

Installation manual plugs and connectors with screw connection (16/32 A)

Operating instructions. Speed monitor D / / 2014

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

Option H10, Multi-line 2 unit with USB service port. To be used when the multi-line 2 unit service port is USB type

Installation Instruction. HART Add-On Module

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

Operating Manual for Controller mp-x

ModemUSB/E12 User Manual v0.1

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

SIMPLY PRECISE USER MANUAL. ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation

PTZ Control VMC Joystick

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

FlowJam Plus. Superior with Solids. Material flow monitor with blockage detector. Operating instructions

Operating instructions Optical distance sensor. OID25x / / 2014

TELTONIKA ModemUSB/G10 User Manual v0.1

Operating manual. UNIData1100. Data transfer software for data exchange between a PC and UNIMET 1000/1100ST

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. OID20x / / 2014

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

English. Operating Manual. Universal Isolating Amplifier TV125M / ST125M. Save for later reference. Companies / Brands of GHM

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Operating Instructions VEGAMET 381

Operating Manual -ENGLISH- Page 1 KWG-ISO

FX-USB-AW/FX3U-USB-BD. USER'S MANUAL USB Driver Installation Edition

Technical Documentation

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Technical Documentation

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Serial PROFIBUS Interface

Electronic Temperature Controller. Instruction Manual Version

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

3700 SERIES USER MANUAL

Installation and Maintenance

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

BNI USB A501. USB IO-Link Master User's Guide. english

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Operating Manual Configuration software for EASYBus devices

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

SolConeX extra-low voltage flange socket

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

Operating instructions Evaluation system for flow sensors VS / / 2013

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

SONOFLOW Monitor Short Instructions. For SONOFLOW Sensors of the Series CO.55 V2.0

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a

Operating instructions Optical distance sensor. OID20x / / 2015

Operating Manual MPI-300 NCS-M Parameter Tool

Operating Instructions

BODAS-design. RE 95112/ /8 Replaces: Data sheet. Version 3.0. Contents. Features

38 MHz Passive Voltage Probe R&S RT-ZP1X

R60 USB to CAN interface Manual (1.4 EN)

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

Sliding shutter control Aluminium shutters

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

CPCI-PS24 24V-Power Supply

Data setting software MEXE02

MANUAL Functional Safety

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Card Enrollment Station. User Manual UD05870B

MANUAL LML-P, LML-S, LML-Ex

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

Cube LAN Gateway. Operating manual BC-LGW-O-TW

testo Saveris Adjustment software Instruction manual

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

TETRIS 2500 High Impedance Active Probe. Instruction Manual

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

2-PHASE STEPPING MOTOR DRIVER FE Z4 TRANSFER

Expansion module EM-BAC-MOD-01. Installation manual

Operating Instructions Differential Pressure Transducer PS27

Transcription:

Operating manual GTL - Configuration tool Please keep the manual for future use. V1.00-01

GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33 www.greisinger.de info@greisinger.de Table of contents page 1 Intended use (application area)... 3 1.1 Safety signs and symbols... 3 1.2 Safety guidelines... 4 1.3 Product liability and und warranty... 4 1.4 Standards and guidelines... 4 2 Product description... 5 2.1 Scope of supply... 5 2.2 Functional principle... 5 3 Assembly and installation... 5 3.1 System requirements... 5 3.2 Installation GTL - Configurator... 6 3.3 Electrical installation... 6 4 Operation of the software... 7 4.1 GTL transducer settings... 7 4.2 Warning messages of the software... 8 5 Specifications USB adapter... 9 6 Return... 10 7 Disposal notes... 10 8 Troubleshooting... 11 8.1 USB-Driver... 11 8.2 Windows Settings... 12 9 Legal notice... 14 2 / 14

1 Intended use (application area) The chapter "Product description" provides details on the application area. The operational safety of the device is only ensured for the intended use according to this manual. Any changes not described in this manual must only be done by personnel authorized by the manufacturer due to security and warranty aspects. Unauthorized reconstructions or changes are expressly prohibited. Application-specific hazards may provoked by improper or not intended use of this device. The device must not be used in potentially explosive areas or for security-related components according to SIL. General safety notices, application This manual must be kept at a place at which it can be looked at anytime by the qualified personnel. All procedures described in this manual must only be done by skilled and authorized personnel with adequate protective clothing. All rights reserved. 1.1 Safety signs and symbols Warnings are labeled in this document with the followings signs: DANGER Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance. Attention! This symbol warns of possible dangers or dangerous situations which can provoke damage to the device or environment at non-observance. Note! This symbol point out processes which can indirectly influence operation or provoke unforeseen reactions at non-observance. 3 / 14

GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33 www.greisinger.de info@greisinger.de 1.2 Safety guidelines Read this document carefully before you use the device. Assure that the device is suitable for the desired application. The operator is responsible for interference-free operation. He must assure the accordance to required job safety measures of the current applicable regulations during the whole period of application. DANGER 1.3 Product liability and und warranty Disclaimer: The content of the manual is checked for conformity to the described device. However, differences cannot be excluded completely. Therefore we cannot guarantee full conformity. All information of this manual are continuously checked and necessary corrections are included to the following editions. Technical modifications are reserved. Additionally all claims are subject to the latest "General Terms of Delivery for Products and Services of the Electrical Industry (ZVEI)" 1.4 Standards and guidelines Conform to EMVG 2004/108/EG CE-conformity EN 61326-1 : 2007 (class B, table 3) 4 / 14

2 Product description Configuration tool for configuring temperature sensors of type GTL with integrated transducer. 2.1 Scope of supply USB interface adapter Connection cable for M12-plug Connection cable with loose ends Connection cable with alligator clips CD with driver and configuration software "GTL Configurator" Operating manual possibly further documents 2.2 Functional principle The GTL - Configuration adapter is connected to a Computer via USB interface. Suitable connection cables for all 3 possible device types are provided to connect the GTL to the adapter. The configuration software can read-out and change the configuration data of the GTL via the adapter. 3 Assembly and installation 3.1 System requirements Supported system architectures: x86, x64 Supported operating systems: Microsoft Windows XP Microsoft Windows Server 2003 Windows Vista Windows Server 2008 Windows 7 Hardware requirements: 620 MB free hard disk space 1024 MB main memory Minimum: 400 MHz CPU, 800x600 8-bit color Recommended: 1.0 GHz or more CPU, 1024x768 32-bit color free USB 2.0 interface Software requirements: Microsoft.NET Framework 3.5 (SP1) Silicon Labs CP210x USB to UART Bridge device driver version 6.3.0.0 or later 5 / 14

GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33 www.greisinger.de info@greisinger.de 3.2 Installation GTL - Configurator Do not plug-in the GTL - Configuration adapter until the installation has ended successfully. You need a user account with administrator rights to install the software. If you don't have that rights please switch user or ask your system administrator. The USB driver is automatically installed or updated by the GTL Configurator. If the installation program only finds outdated drivers or no driver at all a selection for the driver installation is displayed. The program needs the Microsoft.NET Framework 3.5 (SP1) and installs it automatically from the CD if it isn't already installed. Start the installation by double-clicking "GTL Configurator Setup.exe". Follow the instructions. 3.3 Electrical installation DANGER The device may only be installed by a electrically skilled person. The national and international regulations for installation of electrical systems of the particular country of operation apply. The connection cable with loose ends or alligator clips must be connected first to the transducer. After that it can be connected to the adapter. Connect the suitable connection cable to the transducer: M12 Connect the socket of the connection cable to the M12-plug of the temperature transducer Loose ends Connect wires to the terminals of the transducer: 1 brown wire 2 white wire 1: power supply + 2: power supply - / output Alligator clips Fix alligator clips to the wires of the transducer's connection cable: red clip brown or blue wire black clip white wire b.) Connect the cable to the USB adapter. 6 / 14

4 Operation of the software The software can be intuitively operated. Any error or misentry causes a popup with information and possible solutions. Possible languages of the user interface are English, Czech and German. The language can be changed without program restart by clicking on the flag symbol in the lower left corner of the program window. After program start the whole system is checked and all transducers connected to a GTL - Configuration adapter are read-out. You can change between the connected transducers by means of the central button at the top of the window. Depending on the used transducers some fields may be inactive and cannot be set. 4.1 GTL transducer settings 4.1.1 Measuring range and display Unit: choose between C and F Resolution: A measured value of 10 C ( F) is displayed as 10 if "1" is set and if "0.1" is set as 10.0. The resolution is "0.1" and cannot be changed if the GTL transducer has no display. Measuring range: You can choose between several predefined measuring ranges. Choose "Arbitrary range" to set the range on your own via the fields "Temperature at 4 ma" and "Temperature at 20 ma". The range length must be > 50 C (or > 90 F) Backlight: If the transducer has a display and background illumination you can switch it on and off with this field. 7 / 14

GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33 www.greisinger.de info@greisinger.de 4.1.2 Filter and output Filter: You can choose between several filter speeds. Output in case of an error: You can choose whether the output should be set to > 20 ma (approx. 22 ma) or < 4 ma (approx. 3.75 ma) in case of a detected error (i.e. measured value out of measuring range) Temperature at 4 ma: Lower measuring range limit. This field is only active if "Measuring range" is set to "Arbitrary range". Acceptable values are from -20.0 200.0 C (-4.0 392.0 F) Temperature at 20 ma: Upper measuring range limit. This field is only active if "Measuring range" is set to "Arbitrary range". Acceptable values are from -20.0 200.0 C (-4.0 392.0 F) Tube wall correction: A setting of the parameter Tube wall correction is available if the transducer supports Tube wall correction. WLP10S, silicone thermal conductance paste is used for the calculation. 4.1.3 Offset- and scale-correction Sensor tolerances and/or deviations due to the measuring arrangement can be corrected with the offset and scale value. Incorrect values for offset and scale result in faulty measuring values! You should change these values only if you are absolutely sure about the adjustment. Offset-correction: Adds an offset to the measured temperature value. Acceptable values are from -5.0 5.0 C (-9.0 9.0 F) Scale-correction: Changes the slope of the sensor curve. Acceptable values are from -10.0 10.0 % 4.2 Warning messages of the software Transmission error: sensor module not responding (Found no GTL - Configuration adapter) Transmission error: sensor module not responding (Found no GTL sensors) No GTL - Configuration adapter is found. Check the correct installation of the USB driver and the right connection of the GTL - Configuration adapter. In very few cases it is necessary to deactivate the energy-saving policy of your computer. No sensor is found at the GTL - Configuration adapter Plug-in a GTL sensor with integrated transducer, check the cable connection 8 / 14

5 Specifications USB adapter to the sensor. Connections: Computer: standard USB-plug (type A) GTL: 2-pole screw / clamp terminal, RM 3.81 (max. cross section: 1.5 mm²) GTL connection data: Max. load: 20 ma Transfer rate: 4800 Baud Short-circuit strength: short-circuit proof for short time Insulation voltage: 500 V DC Power supply: no external supply required (USB port powered) Current consumption: max. 300 ma Working conditions: -25... +50 C Storage temperature: -25... +70 C Housing: Dimensions: 56 x 31 x 24 mm (L x W x H) Cable length: 30 cm Weight: 40 g 9 / 14

GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33 www.greisinger.de info@greisinger.de 6 Return DANGER Statutory regulations to protect environment and our employees demand that it must be possible to handle returned devices that have been in contact with liquids without any danger to persons or environment. Therefore, we ask you to take the following regulations into account if you have to send a device back for inspection or repair: You can download a returns form from our homepage at "Download" -> "Repair / Service". The repair can be carried out fast and without queries if: each device has a filled returns form. the device is cleaned and a adequate package is used that prevents damaging to the device. the filled form and (as the case may be) a material safety data sheet of the measured medium is fixed outside to the package. 7 Disposal notes Material separation and recycling of device components has to be considered at the disposal. Currently applicable regulations and rules must be observed. This device must not be disposed as residual waste. To dispose this device, please send it directly to us (adequately stamped) together with a filled returns form (see chapter 6). We will dispose it appropriately and environmentally friendly. 10 / 14

8 Troubleshooting 8.1 USB-Driver 8.1.1 Driver update not successful (x64 edition) In some cases on 64 bit windows systems (e.g. Windows XP x64 Edition) it may happen, that the existing drivers of the known devices are not updated. In this case connect the GTL Configuration adapter and open the Device Manager as administrator. In Ports (COM & LPT) right click the corresponding Silicon Labs CP210x USB to UART Bridge (COMxx) device. In the context menu select Properties and open the tab Driver in the new window. Press the button Uninstall and activate delete driver from this Computer. If then a manual select of the driver position is needed, the folder with the driver information is found in the GTL Configurator folder under SiLabs CP210x V followed by the version (e.g. SiLabs CP210x V6.5 here always select the newest one). 8.1.2 GTL Configuration adapter or driver not found The Driver files are copied by the GTL Configurator Setup to the installation folder, under SiLabs CP210x V followed by the version (e.g. SiLabs CP210x V6.5 ). If this directory does not exist run the setup again. Now connect the GTL Configuration adapter and open the Device Manager as administrator. Now a device exclamation mark should be shown. Normally it can be found under Ports (COM & LPT) and its name is Silicon Labs CP210x USB to UART Bridge. Right click the device and select Properties in the context menu and open the tab Driver in the new window. Here click the button Update Driver, In the Hardware Update Wizard check Install from a list or specific location (Advanced) and press next. Then only check Include this location in the search and press Browse. In the new window select the driver position press OK, then Next and follow the instructions on the screen. 11 / 14

GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33 www.greisinger.de info@greisinger.de 8.2 Windows Settings 8.2.1 GTL connected to the Computer is always turned off The reason for this are the computer s energy saving options. For saving energy the computer can turn off the GTL Configuration adapter. To prevent this, connect the GTL Configuration adapter and open the Device Manager as administrator. In Ports (COM & LPT) right click the corresponding Silicon Labs CP210x USB to UART Bridge (COMxx) device. In the context menu select Properties and open the tab Power Management in the new window. Here deselect Allow the computer to turn off device to save power. 12 / 14

13 / 14

B07.0.1X.6C-02 9 Legal notice Managing director: Günther Oehler Place of fulfillment and place of jurisdiction: Regenstauf Copyright: GREISINGER electronic GmbH. All rights reserved. Reprint, digital usage of any kind, reproduction only with written permission of GREISINGER electronic GmbH.