Operating manual GTL 142 GTL 152. Temperature probe. Please keep the manual for future use.

Similar documents
Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Englisch. Operating Manual. Capacitive Level Sensor MLC490/491/492. Retain for future reference. V3.01. Company / GHM brands

Operating Manual MLC420/422. Capacitive Level Switch. Patent no.: DE Retain for future reference V3.01

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Digital Quick-Response Thermometer

Manometer. (Over- /Under- And Difference Pressure) Operating Manual GDH

GMH Operating Manual for Digital Quick-Response Thermometer

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Hygro-/Thermometer. Operating Manual GFTH 95

Englisch. Operating Manual. Operating Software GHMware Retain for further references. Unternehmen / Marken der GHM

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Installation manual plugs and connectors with screw connection (16/32 A)

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Operating Instructions VEGAMET 381

Inductive sensor NI3-EG08K-Y1-H1341

Electronic Temperature Controller. Instruction Manual Version

Operating instructions. Standstill monitor A / / 2011

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Temperature Switches

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

TEMPERIX S Clamp. FAFNIR GmbH Schnackenburgallee 149 c Hamburg Germany

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Operating Instructions

Operating instructions. Switching amplifier DN0210 DN / / 2015

LS 6600 Technical Datasheet

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

MANUAL LML-P, LML-S, LML-Ex

CPCI-PS24 24V-Power Supply

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Manual MPI-300 NCS-M Parameter Tool

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Operating instructions. Speed monitor D / / 2014

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

Type Quickstart (from device Version 2)

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

English. Operating Manual. Universal Isolating Amplifier TV125M / ST125M. Save for later reference. Companies / Brands of GHM

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

SolConeX Wall-Mounted Socket, 16 A

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions Evaluation system for flow sensors VS / / 2013

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Inductive sensor with analog output BI15-M30-LI-EXI

Flow Sensor SONOFLOW CO.55

Immersion Temperature Sensors

MDM 011-Z1 Regen Resistor

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

Installation Instruction. HART Add-On Module

Operating Instructions

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Type Quickstart

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

Operating instructions RFID evaluation unit DTE / / 2016

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

FlowJam Plus. Superior with Solids. Material flow monitor with blockage detector. Operating instructions

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Vibration Sensor Type 640

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

SolConeX extra-low voltage flange socket

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Technical Manual Room temperature controller

Operating Manual -ENGLISH- Page 1 KWG-ISO

BA01236F/00/EN/ Products Solutions Services. ToF Adapter FXA291

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Installation instructions Inclination sensor EC2019 EC / / 2013

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

MSI-RM2 Safety Relays

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

KROHNE 12/ GR Installation and Operating Instructions BM 500

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

Transcription:

Operating manual Temperature probe GTL 142 GTL 152 Please keep the manual for future use. L01.0.1X.6C-02

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de Table of contents Page 1 Intended use (application area)... 3 1.1 Safety signs and symbols... 3 1.2 Safety instructions... 4 1.3 Product liability and warranty... 4 1.4 Standards and directives... 4 1.5 Approval... 4 2 Product description... 5 2.1 Scope of supply... 5 2.2 Ambient temperature... 5 2.3 Design of temperature probe... 5 2.4 Type label... 6 3 Mounting and electrical installation... 6 3.1 Mechanical mounting... 6 3.2 Welding instructions... 7 3.3 Electric installation... 8 3.4 Connection... 8 4 Operating elements and functions... 9 4.1 Operation (with integrated on-site-display)... 9 4.2 Configuration of device with button (with integrated on-site display)... 9 4.3 Configuration of device with GTL - Configuration tool... 10 5 Commissioning, maintenance and servicing... 11 6 Technical data... 12 6.1 Mechanical design / dimensions... 13 6.2 Ordering code... 14 6.3 Accessories... 15 7 Device transport and storage... 15 8 Returns... 15 9 Disposal... 15 10 EC conformity certificate... 16 11 Imprint... 16 2 /16

1 Intended use (application area) The chapter Product description provides details on the application area. The operational safety of the device is only ensured for the intended use according to this manual. Any changes not described in this manual must only be done by personnel authorized by the manufacturer due to security and warranty aspects. Unauthorized reconstructions or changes are expressly prohibited. Application-specific hazards may be provoked by improper or not intended use of this device. The device must not be used in potentially explosive areas or for security-related components according to SIL. General safety notices, application This manual must be kept at a place at which it can be looked at any time by the qualified personnel. All procedures described in this manual must be done only by skilled and authorized personnel with adequate protective clothing. All rights reserved. 1.1 Safety signs and symbols Warnings are labeled in this document with the followings signs: GEFAHR Caution! This symbol warns of imminent danger, death, serious injuries and significant damage to property at non-observance. Attention! This symbol warns of possible dangers or dangerous situations which can provoke damage to the device or environment at non-observance. Note! This symbol point out processes which can indirectly influence operation or provoke unforeseen reactions at non-observance. Table 1 3 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 1.2 Safety instructions Read this document carefully before you use the device. Assure that the device is suitable for the desired application The operator is responsible for interference-free operation. He must assure the accordance to required job safety measures of the current applicable regulations during the whole period of application. GEFAHR 1.3 Product liability and warranty Disclaimer: The content of the manual is checked for conformity to the described device. However, differences cannot be excluded completely. Therefore we cannot guarantee full conformity. All information of this manual are continuously checked and necessary corrections are included to the following editions. Technical modifications are reserved. Additionally all claims are subject to the latest General Terms of Delivery for Products and Services of the Electrical Industry (ZVEI). Please note that Greisinger electronic cannot check or repair devices without the specified, fully completed form (see chapter 8, Returns ). 1.4 Standards and directives Conform to EMVG 2004/108/EG CE-conformity EN 61326-2-3:2007-05 Vibration test EN60068-2-6 1.5 Approval EHEDG Conform to FDA and 3A 4 /16

2 Product description The GTL 142 and GTL 152 are temperature probes with or without transmitter for collecting and converting temperature input signals. 2.1 Scope of supply Temperature probe This operating manual Possibly further documents 2.2 Ambient temperature Restrictions dependent on ambient temperature (recommended values) Max. ambient temperature Max. process temperature Note up to 20 C 150 C up to 40 C 130 C 140 C if t 30min up to 60 C 110 C 120 C if t 30min Note: The max. permitted process temperature depends on the ambient temperature and must not be exceeded to ensure faultless functioning. 2.3 Design of temperature probe GTL 142 e housing type label wrench size SW17 process thread sealing edge to process Figure 1 sensor tip 5 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 2.4 Type label The type label (Fig. 2) provides important identification data: Type and article name Technical data Serial number 3 Mounting and electrical installation 3.1 Mechanical mounting Figure 2 The correct seating of the device, correct function and sealing of the connection can only be ensured by using the GHMadapt accessories. The device is not suitable for use in abrasive materials. No additional sealing material (e.g. Teflon tape) must be used on the sealing cone or on the thread. Use a suitable welding mandrel for the correct installation of GHMadapt welded sleeves. The switch must not be sued as a welding aid. Installation direction of the welded sleeves (Fig. 3 and 4). The marking shows the position of the M12 connector or cable screw fitting. Line marking on the sleeve Figure 4 Figure 3 6 /16

3.2 Welding instructions Welding in tanks: Figure 5 1. Drill a hole with the outer diameter of the sleeve, max. tolerance +0.2 mm 2. Tack the sleeve in place at 4 points (Fig. 5) Note the correct sequence of the tacking 3. Screw in the welding aid (see Product information GHMadapt AMH121, -122, -123) 4. Weld the sections between the tacks 4 sections for thread M12 Welding in pipes: In addition to the APH pipe system, ball sleeves or sleeves with a welding shoulder for pipes with collars are also available. Note the maximum permissible tightening torque when mounting! Remove the switch before carrying out any welding work on the tank. This will avoid damage to the electronics due to inductive coupling. The case must not be used for screwing in! Tightening will result in damage to the electronics. Use the hexagonal provided for screwing in the switch. In order to avoid excess heating or warping of the sleeve during the welding process, allow a pause between the individual sections so that the sleeve can cool down. 3.2.1 Instructions for installation to EHEDG The installation without gap and dead space is based on the hygienic elastomer-free sealing principle. For this purpose, we offer corresponding fitting accessories such as sleeves and adapters with the GHMadapt sealing principle. 7 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 3.3 Electric installation GEFAHR The device must be installed only by a qualified electrician. The national and international regulations for the installation of electrical systems of the relevant operator country apply. Power supply according to DIN EN66664-1, SELV, PELV. 3.4 Connection For electric connection: Cable junction M12-plug With transmitter Without transmitter Figure 6 Figure 7 For electric connection: Cable gland M16x1.5(PG) With transmitter Without transmitter Figure 8 Figure 9 8 /16

4 Operating elements and functions 4.1 Operation (with integrated on-site display) min/max Press button (Fig. 10) shortly: The following points are displayed one after another: Display Duration Lo 0.5s Min value 1.5s Hi 0.5s Max value 1.5s blank 0.5s Current value Figure 10 Press button for 2s while the device still displays Lo, Hi or the corresponding values to delete min/max values. Confirmation: display of CLr 4.2 Configuration of device with button (with integrated on-site display) To configure the device s functions proceed as follows: Switch the device on Press button 4s until the first parameter rang is displayed o Press button shortly to select next parameter o No button-press >5s: restart, data is saved Press button for 2s until the current parameter value is displayed o Press button shortly to set parameter value o No button-press >2s: back to parameter selection Parameters adjustable via button Parameter Display Parameter value Meaning Temperature range rang r1-10.0..40.0 C r2 0.0 50.0 C r3 0.0 100 C r4 0.0 150.0 C r5 0.0 200.0 C Filter FiLt off no filter 1 filter stage 1 2 filter stage 2 3 filter stage 3 Default state of output da.er Lo 3.75 ma Hi 22 ma Backlight bl off off on on 9 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de Example: Switch-on backlight Switch the device on Press button 4s until the first parameter rang is displayed Press button shortly to select next parameter until bl is displayed Press button for 2s until the current parameter value ( off or on ) is displayed Press button shortly to select parameter value on No button-press >2s: back to parameter selection No button-press >5s: restart, data is saved 4.3 Configuration of device with GTL - Configuration tool The transmitter integrated in GTL 142 / GTL 152 provides several configuration possibilities. For parameterization the GTL - Configuration tool is needed. The operating manual of the GTL - Configuration tool provides detailed information. The following parameters are supported: Measuring range Filter Default state Parameter measuring range: 5 predefined and a freely selectable measuring range can be chosen. M1: -10..+40 C M2: 0..50 C M3: 0..100 C M4: 0..150 C M5: 0..200 C MB: measuring range freely selectable, span 50 K Parameter filter Integrated software filter (low-pass filter) to smooth the output signal. 4 filter steps are available: 0: Filter off, maximal reaction time 1: T 90 approx. 250 ms 2: T 90 approx. 800 ms 3: T 90 approx. 3000 ms Parameter default state This parameter allows selecting whether < 3.75 ma or > 20.5 ma is outputted in case of a detected error. 10 /16

5 Commissioning, maintenance and servicing Commissioning 1. Check the integrity at the sleeve. 2. Ensure that the M12-plug or cable gland is correctly fitted. Maintenance When cleaning take care that case surface and seals are not attacked by the cleaning agent. If the case is cleaned using a high-pressure cleaning appliance, ensure not to direct the spray jet at the electrical connection. Deposits of cleaning agents on the thread must be avoided. Servicing Clean the switch (and especially the sealing cone) and the auxiliary tool after dismantling and before refitting the device carefully with suitable tools and agents, in order to maintain the integrity and hygiene requirements. The device itself cannot be repaired. 11 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 6 Technical data Housing Probe head Neck tube (GTL152) Protection tube and tip Protection class : 1.4305 (V2A) : 1.4305 (V2A) : 1.4404 (V4A) : IP67 / IP69K Ambient conditions Working temperature : -20..+70 C Storage temperature : -20..+85 C Climate class : EN 60068-2-38:06/2010 Vibrations : EN 60068-2-6 Sensor Sensor type : Pt100 to IEC 60751 Temperature range : -40..200 C (probe tip) Accuracy : class A, class AA Response time : FS Ø 3 mm: T 90 1.5 s : FS Ø 4 mm: T 90 3.6 s : FS Ø 6 mm: T 90 7.4 s Process temperature : -20..+200 C (see chapter 2.2) : CIP-/SIP-capable Process pressure : max.10 bar Process material : 1.4404 (V4A) Process connection : M12 Tightening torque : 5..10 Nm Electric connection : M12-plug or cable gland Transmitter Supply voltage : 10..28 V DC Measuring ranges : -10 C..+40 C, 0 C..+50 C, 0 C..+100 C : 0 C..+150 C, 0 C..+200 C : or freely selectable within range -20..200 C Measuring span : 50K Accuracy : 0.2% FS Temperature drift : 0.01 % FS/K Reaction time* : 200 ms (filter off) : filter selectable in 4 steps Initialization time : 1.5 s Output : 4..20 ma, 2-wire Sensor break / short circuit: 3.75 ma or 20.5 ma 12 /16

6.1 Mechanical design / dimensions GTL 142 GTL 152 Figure 11 13 / 16

GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax -33 www.greisinger.de info@greisinger.de 6.2 Ordering code 1. 2. 3. 4. 5. 6. 7. GTL - - - - - - 1. Design type 142 without neck tube 152 with neck tube (HL = 100 mm) 2. Electric connection P cable screwing M16x1.5 (PG) M cable connection M12-plug 3. Fitting length EL 0050 50 mm 0100 100 mm 0150 150 mm 0250 250 mm xxxx any EL in mm (e.g. 320 = 320 mm) Ø 6: max. 1000 mm 4. Diameter protection tube and probe tip 6 Ø 6 mm, without taper 4 Ø 4 mm, without taper 3 Ø 6 mm, with tapered probe tip Ø 3 mm 5. Accuracy class A class A D class AA (1/3 class B) 6. Transmitter GTML1 (programmable) 00 without transmitter M1 with transmitter, measuring range -10..+40 C M2 with transmitter, measuring range 0..50 C M3 with transmitter, measuring range 0..100 C M4 with transmitter, measuring range 0..150 C M5 with transmitter, measuring range 0..200 C MB transmitter with special measuring range in C (state special measuring range separately e.g.: 0..75 C or -20..+30 C) keep a minimum range of 50 C 7. Option 00 without option VO with integrated on-site display (LCD) (only combined with electric connection: cable connection M12-plug and integrated transmitter) 14 /16

6.3 Accessories For sleeves, adapters and connection cables, see separate product information Accessories Hygienic Design. 7 Device transport and storage The case must be packed carefully and stress-free for transport (no automatic binding of the packaging). The device must be stored under the ambient conditions specified in the technical data. 8 Returns GEFAHR Legal regulations for the protection of the environment and our personnel require that returned devices which have come into contact with media can be handled without risk to personnel and the environment. If you send a device back to us for checking or repair, we must request that you pay strict attention to the following requirements: A returns form can be downloaded from our homepage under: Download / Repair/Service. The repair can be carried out quickly and without further questions if: 1. A completed form is available for every device. 2. The device has been cleaned and returned in packaging which prevents any damage to the device. 3. The completed form and any possible safety data sheet on the measurement medium are attached to the outside of the packaging. 9 Disposal The device components and packaging must be separated by materials for disposal. The legal regulations and guidelines applicable at the relevant time must be observed. The device must not be disposed of as general waste. If a device is to be disposed of, send it back to us direct with the completed Returns form specified under Point 8 and we will then take care of proper disposal. 15 / 16

10 EC conformity certificate 11 Imprint Managing Director: Günther Oehler Place of fulfillment and jurisdiction: Regenstauf Copyright: GREISINGER electronic GmbH. All rights reserved. Reprinting, digital use of any type and duplication is allowed only with the written permission of GREISINGER electronic GmbH.