PL-8 PL-PLUS POWER CONDITIONER AND LIGHT MODULE

Similar documents
Series II PL-PRO II PL-PRO D II PM-PRO II 20A POWER CONDITIONERS. Series Mode Protection

SERIES II 20 AMP POWER CONDITIONERS

PS-8R POWER SEQUENCER, 15A

AR-1215 AC LINE VOLTAGE REGULATOR MODELS AR-1215, AR-1215J, AR-2306 VOLTAGE REGULATORS

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PS8 - II. Professional Power Sequencer. User s Manual

The PST-6. Owners Manual 1

AC LINE VOLTAGE REGULATOR AND POWER CONDITIONER

POWER FACTOR PRO MANUAL

1

features Introduction

MFJ ENTERPRISES, INC.

A Creative Light & Sound Company

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Power and protection for your rackmount and cabinet equipment.

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

What s in the Box. Table of Contents

A Creative Light & Sound Company

I need to protect my equipment against damaging power surges and spikes.

Surge Protectors and Digital Timer

ETA-PD8A AC Power Conditioner & Distribution Unit

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web:

MFJ ENTERPRISES, INC.

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

DV-HDA-12AUD 1x2 HDMI Distribution Amplifier Manual

The PST-8D. Owners Manual 1

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Plugstrip and Wallmount Surge Protectors

AP-S20 AC Power Distribution Unit & Surge Suppressor

Protect It! 8-Outlet Industrial Safety Surge Protector, 25-ft. Cord, 3900 Joules, Cord Wrap, Hang Holes

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

ΤΥΠΟΣ ΤΕΧΝΙΚΑ ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ TIMH

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal

DV-HDA-14AUD 1x4 HDMI Distribution Amplifier Manual

Pulse LED Instruction Guide

USER MANUAL. DV-HDA-15 HDMI Distribution Amplifier

MFJ-1164B AC Line RFI Filter

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

AP-S15HR AC Power Conditioner & Distribution Unit

Broadband Automatic Disconnect Switch. User Manual

1-36V, 0-3A DC Power Supply

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

ETA-PD8 Power Conditioner & Distribution Unit

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal

CANARY AUDIO. Vacuum Tube Compact Disc Player CD-100 OWNER S MANUAL. Handcrafted in California MADE IN USA

User Manual. C Type Power Filter. Model C3 and C3BLK

TSD-DA28 2x8 Balanced Line Distribution Amplifier

Basketball Shot Clock Set LX2180 Manual

User s Guide. POWERVAR Single Phase Power Conditioners

SX2200 Series INSTALLATION INSTRUCTIONS. Electronic Systems Protection, Inc 8001 Knightdale Blvd. Suite 121 Knightdale NC 27545

Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing

Elite 10 E owner s manual

Burson Audio DA-160 Audio DAC User Manual

DVI ELR Extender over one CAT5

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

1

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

OPERATING MANUAL TCAT-2DF CONTROLLER PHYSITEMP INSTRUMENTS INC. 154 Huron Avenue Clifton NJ USA Tel: Fax:

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Now, we are proud to introduce Series

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

7-Outlet Home/Business Theater Surge Protector, 6-ft. Cord, 2100 Joules, Tel/Modem/Coax Protection

Dirty Power... A Guide to Surge Suppression & Filtering. Surge & Signal Protection for Business-Critical Continuity. EmersonNetworkPower.

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

20W Tungsten-Halogen Light Source. Operation Manual

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

Isobar UL 1363 Hospital-Grade 6-Outlet Surge Protector, 15 ft. Cord, 3330 Joules, LEDs, Not For Patient-Care Vicinities

USER MANUAL. DV-HXT-1 HDMI to CAT5e /6 EXTENDERS LIT1375A

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

User Guide. Control Box. RoscoLED TM.

FEATURES. - COMPATIBLE WITH ALL ipod / MP3 PLAYERS / SATELLITE RADIOS. - SMALL IN OR UNDER DASH CONTROL HEAD WITH 3.5mm HEADPHONE INPUT

After the storm leaves the area, you pat yourself on the back for protecting your data and equipment. The worry is over. Or is it?

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

CANARY AUDIO CA-430. Vacuum Tube MM/MC Phono Preamplifier OWNER S MANUAL. Handcrafted in California MADE IN USA

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Common Mode Noise The Often Neglected Tenth Power Problem

Operating Manual RISH DPM Hz

Contents. Table of. Welcome to Ayre Connections and Installation Controls and Operation Customization and Configuration...

USB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1

Splitter for HDMI 1.3 with Digital Audio

JuiceRack & JuiceBlock 500 series Power Supplies. Operating Manual V 1.1

User's Guide. MiniTec TM Series Model MN25 MultiMeter

700 Series 200 Amp Clamp Meters

Dual Link DVI Extender

Office Product. Surge Protection Devices

Sonic Ruptor 400. User Manual

iconverter 2-Module Power Chassis

Innovative Circuit Technology Ltd.

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Operating Instructions

Transcription:

PL-8 PL-PLUS POWER CONDITIONER AND LIGHT MODULE 15 AMP SERIES

PL-8 FEATURES Two slide-out, swiveling light fixtures for rack illumination Eight accessory outlets in rear, controlled by a front panel switch Triple mode varistor spike and surge protection RFI / EMI filtering Circuit breaker, 15-amp rating Dimmer control for lamp brightness Separate switch for lamps Ten-foot, heavy duty 14-gauge AC cord PL-PLUS FEATURES All PL-8 features, plus Line Voltage monitor reads 90 to 128 Volts High performance RFI/EMI noise filter PL-8 The Furman PL-8 and PL-PLUS Power Conditioners and Light Modules are the perfect accessory for any rack-mount system. lnstall a PL-8 in the top slot of your rack, and the eight switched AC outlets on the rear panel will power up all your equipment while its two slide-out light fixtures provide discreet illumination of the controls on stages, in studios, and in other dark places. A dimmer control lets you adjust the lamp brightness to just the right level. The PL-8 protects your delicate electronic equipment by combining a high-voltage surge and transient suppressor with an RFI/EMI interference filter. The fast-acting suppression circuit responds in less than a nanosecond, clamping transient voltages to safe levels. The peak clamping voltage is 340 VAC, effective for spikes on any of the three AC conductors, and the clamping circuitry can absorb a total of up to 240 Joules. These specifications indicate a very high degree of protection when compared with competitive products. The filter works to prevent noise from fluorescent lights, dimmers, radio transmitters, and similar sources of electronic pollution from contaminating the AC line and from there, leaking 1

into sensitive audio, video or computer circuits. The eight circuit-breaker protected outlets are rated at 15 amps. If the total load on the PL-8 (combining all outlets) exceeds 15 amps, the circuit breaker will trip, cutting off power to your rack. If this occurs, reduce the load by unplugging one or more units from the PL-8. Then push the black button on the circuit breaker (on the front panel) down and in to reset it. The PL-8 s lamps come supplied with five-watt night-light bulbs. Replacements are readily available at most hardware stores or almost anywhere household light bulbs are Light Switch sold. Bulbs are easily replaced without removing the unit from the rack by unscrewing the cap on the end of each light tube. The caps and light tubes become quite warm to the touch in normal operation. To avoid burning your fingers, allow the cap to cool completely before unscrewing it. Be careful not to push the tubes in while the caps are unscrewed. If you find that the heat from the tubes is excessive, try reducing the setting of the dimmer knob. As an alternative, you may wish to substitute four-watt bulbs or even colored Christmas tree bulbs. The PL-8 has a master switch for the rear outlets which lights up when the Circuit Breaker Dimmer Switch Rack Lights 8 Switched Outlets Power Switch 2

power is on. There is also a separate switch for the lamps, allowing you to check your rack s settings before applying power to it. The lights do not turn off automatically when the tubes are pushed in, so be sure to use the switch. PL-PLUS Model PL-PLUS is an enhanced version of the PL-8. Its front panel provides a handy display of AC line voltage by means of a 20 LED bargraph meter, reading from 90 to 128 Volts in two-volt steps. The normal range voltages are indicated in green, with moderate and extremely high or low voltages in yellow and red respectively. Note that the LED meter continues to read even when the master switch is off. This was done Light Switch Voltmeter purposely to allow you to check the voltage before powering up. The LEDs are designed for continuous, ongoing use. They consume little power, just a few cents worth per month, much like a clock. The PL-PLUS features 15 amp capacity, as well as a more sophisticated RFI filter network with a greatly improved capacity for stopping line noise. This filter is a low-pass type, composed of high-voltage capacitors and an inductor. It passes the low (50 or 60 Hz) line frequency while rejecting high frequencies, with maximum attenuation in the region from 1 to 100 MHz. The PL-PLUS voltmeter has a basic accuracy of +/- 2 volts, (extreme cold or heat may cause an additional one volt of error). Should the voltage reading ever become inaccurate, it can be easily recalibrated by a qualified service technician. Circuit Breaker Dimmer Switch Rack Lights Power Switch 3 8 Switched Outlets

Please note that the voltage reading is advisory only. The PL-PLUS does not compensate for high or low line voltage. If you frequently move your rack to different locations, derive power from generators, use long extension cords, travel internationally or are in an area prone to brownouts, you may benefit from the use of one of Furman s AR Series AC Line Voltage Regulators. 220/240 VOLT VERSIONS ( E SUFFIX) Versions of the PL-8 and PL-PLUS with the E suffix are intended for use in countries with nominal 220 to 240 volt AC lines. These units have 10 rear panel outlets, using the internationally accepted IEC-320 connectors, and are rated at 10 amps. The voltmeter on the PL-PLUS E reads from 180 to 256 volts AC. EFFECTS OF LIGHTNING AND INCORRECT VOLTAGES Lightning presents the most difficult circumstance faced by power protection products. The degree of protection a PL-8 or PL-PLUS unit can offer depends on the intensity of the strike. If lightning strikes a distant power line and causes a relatively small disturbance to reach your location, the spike suppressors in the PL unit will absorb the excess voltage invisibly and harmlessly. However, if lightning strikes the actual building where the PL unit is installed (or somewhere nearby), some damage may be unavoidable due to the extremely high voltage and current present. If this does occur, the damage, most likely, will be limited to the PL unit itself and will affect only the spike suppression components (called varistors or MOV s.) In this suicide mode, the PL unit will sustain minor damage to itself. However, it generally will protect all equipment plugged into it from much more serious and costly damage as long as that equipment is properly grounded. Proper grounding requires the use of three-prong AC cords and that the outlets themselves are actually grounded (as specified by electrical codes). Any PL unit known to have taken a direct lightning hit should be checked by a qualified technician or Furman factory staff to determine whether the MOVs need replacement. (If they are damaged, the PL unit may appear 4

to be working normally, but its vital spike-suppression capability will be eliminated.) You should not rely exclusively on the PL unit for optimum protection against a direct lightning hit. The first line of defense against lightning should be a lightning arrestor installed on your building s electrical service entrance. If your building does not have one, contact your local power company or an electrical contractor to have one installed. The PL-8 and PL-PLUS are not intended to protect against accidental connection to an improper voltage supply (such as 220 Volts in North America or 380 Volts in other areas.) If such a connection is made, the PL unit s MOVs will most likely be destroyed, which may or may not provide sufficient time for its circuit breaker to trip. If it does not trip in time, it is possible for equipment downstream to be damaged. In our experience, such accidents happen surprisingly often. For complete protection against this possibility, a more sophisticated protection device is needed, such as a Furman PRO Series Power Conditioner, AR Series AC Line Voltage Regulators, or Furman s SMP products. DEFINITIONS SPIKE: This is a pulse of energy on the power line. Spikes can have voltages as high as 6000 volts. Though they are usually of very short duration, the energy they contain can be considerable, enough to damage sensitive solid-state components in audio and computer equipment. Spikes can also foul switch contacts and degrade wiring insulation. They are an unavoidable component of electric power. They are caused unpredictably by electric motors switching on or off (on the premises or outside), utility company maintenance operations, lightning strikes and other factors. Spikes (also called surges or transients) are absorbed by special components called varistors or MOVs in the PL-8 and PL-PLUS to provide safe voltage levels to protect your equipment. RFI/EMI INTERFERENCE: Noise from RFI (Radio Frequency Interference) or EMI (Electro Magnetic Interference) involves lower voltages and less energy than is found in spikes, but it is continuous rather than transient in nature. It is not likely to cause damage, but it can certainly be annoying, producing static in audio circuits, snow on video screens, or garbled data in computers. Noise can be introduced into AC lines by nearby radio transmitters, certain kinds of lighting, electric motors, and other sources. Because noise occurs at higher frequencies than the 50 or 60 Hz AC line, it can be effectively reduced through use of low-pass filtering. 5

THREE YEAR LIMITED WARRANTY The Furman PL-8 and PL-PLUS are protected by a limited three year warranty, covering defects in materials and workmanship, provided that the registration card is filled out and returned by the customer. Otherwise, a one year warranty applies. Products must have a proof of purchase from a Furman authorized dealer. During this period, Furman will make any necessary repairs without charge for parts or labor. Shipping charges to the factory or repair station must be prepaid by the owner; return shipping charges (via UPS ground) will be paid by Furman. This warranty applies only to the original owner. Also, it does not apply to repairs done by other than the Furman factory or Authorized Repair Stations. This warranty may be cancelled by Furman at its sole discretion if the unit has been subjected to physical abuse (including, but not limited to, connection to improper AC or DC voltages), or has been modified in any way without written authorization from Furman. Furman s liability under this warranty is limited to repair or replacement of the defective unit. Furman will not be responsible for incidental or consequential damages resulting from the use or misuse of its products. Some states do not allow the exclusion of incidental or consequential damages, so this limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date (if a Warranty Registration Card was mailed in at the time of purchase, this is not necessary). Before returning any equipment for repair, please be sure that it is adequately packed and cushioned against damage in shipment, and that it is insured. Please enclose a note giving your name, address, phone number and a description of the problem. Service: All equipment being returned for repair must have a Return Authorization (RA) Number. To get an RA Number, please call the Furman Service Department, (707) 763-1010 ext. 120 or 121, between 8 a.m. and 5 p.m. U.S. Pacific Time, or fax to (707) 763-1310. Please display your RA Number clearly on the front of the package. 6

SPECIFICATIONS Current rating: 15 Amps ( E versions 10 Amps) Input Voltage: 85 to 135 VAC ( E versions 190 to 270 VAC) Voltmeter Accuracy: PL-PLUS only: ±2 VAC, calibrated with internal trimpot adjustments Spike Protection Modes: Line to neutral, neutral to ground, line to ground Spike Clamping Voltage: Initial turn-on at 200 Volts; TVSS rating of 400 Volts peak at 500 Amps, L-N, N-G, L-G (tested to UL-1449) (Initial turn-on for E versions, 390 Volts peak L-N; 680 Volts peak N-G, L-G) Response time: 1 nanosecond Maximum surge current: 6,500 Amps Maximum spike energy: 80 Joules per mode, 240 Joules total protection ( E versions 130 Joules L-N, 160 Joules N-G, L-G, 450 Joules total) Noise attenuation: Transverse and common modes: 20 db at 200 khz, rising to >40 db, 1 to 100 MHz Mechanical: Dimensions: 1.75 H x 19 W x 8 D. Weight: 6 lbs (2.7 kg). Construction: Steel chassis, zinc chromate plating;.125 brushed and black anodized aluminum front panel; glass epoxy printed circuit boards. Power Consumption: PL-8, 14 Watts PL-PLUS, 20 Watts Safety Agency Listings: UL, CUL, CE, NRTL-C 092203-C Furman Sound, Inc. 1997 South McDowell Blvd. Petaluma, California 94954-6919 USA Phone: 707-763-1010 Fax: 707-763-1310 Web: www.furmansound.com E-mail: info@furmansound.com