QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

Similar documents
Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Retired. Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

QuickSpecs. Models. Overview

QuickSpecs. What's New. Models. Overview

QuickSpecs. Models. Overview

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

QuickSpecs. HPE Integrity Smart Array P411/256 2-port External PCIe 6Gb SAS Controller. Overview. What's New Boot from Tape

QuickSpecs. What's New. Models. Overview

QuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview.

QuickSpecs. What's New. Models. Overview

QuickSpecs. What's New. Models. Overview

QuickSpecs. Models. Overview

The use of the HP SAS Expander Card requires a minimum of 256MB cache on the SA-P410 or SA-P410i Controller.)

QuickSpecs. What's New. Models. Overview

QuickSpecs. Compaq Smart Array 431 Controller M ODELS

QuickSpecs. Models. HP Smart Array P600 Controller Overview

QuickSpecs. Models. Overview

QuickSpecs. What's New. Models. Overview. Retired

QuickSpecs. Model Host Bus Adapter HP H222 Host Bus Adapter B21. HP H222 Host Bus Adapter. Overview

QuickSpecs. Models. Overview

QuickSpecs. HPE Smart Array P222 Controller. Overview

При обращении используйте промокод AND-PDF и получите скидку.

HP SATA DVD-ROM Optical Drives Overview

QuickSpecs. HP Serial-ATA (SATA) Entry (ETY) and Midline (MDL) Hard Drive Option Kits Overview

QuickSpecs HP StorageWorks Modular Smart Array 20

QuickSpecs. HP StorageWorks 60 Modular Smart Array. Overview

QuickSpecs. What's New New HP221 PCIe 3.0 SAS HBA

QuickSpecs. HPE H220 Host Bus Adapter. Overview. Model Host Bus Adapter HP H220 Host Bus Adapter B21

QuickSpecs. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

QuickSpecs. Models. Overview

NOTE: For additional information regarding the different features of SATA Entry drives please visit the SATA hard drive website:

QuickSpecs. What's New New for Smart Array Advanced Pack 2.0: Features are base offering on HP Smart Array P222, P420i, P420, and P421.

QuickSpecs. What's New. HP Smart Array P410 Controller. Overview

QuickSpecs. Models. Overview. Retired

QuickSpecs. What's New. HP Smart Array P411 Controller. Overview

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter

QuickSpecs. HP StorageWorks 60 Modular Smart Array. Overview

HP 20 Modular Smart Array Overview

QuickSpecs. What's New. HP Smart Array P410 Controller. Overview. Retired

Fully integrated and tested with most ProLiant servers and management software. See list of servers with each adapter specifications.

QuickSpecs. HPE Smart Array P431 Controller. Overview

It is also available as part of the HP IS DVD and the Management DVD/HPSIM install.

Rack-mountable 14 drive enclosure with single bus, single power supply. Tower 14-bay drive enclosure, single bus, single power supply, LCD monitor

QuickSpecs. HP Smart Array P430 Controller. What's New. Models. HP Smart Array P430 Controller. Overview

QuickSpecs. HP SAS Hard Drives. Overview

QuickSpecs. HP PCIe IO Accelerators for ProLiant Servers. Overview

QuickSpecs. HP SATA Hard Drives. Overview

QuickSpecs. Models HP I/O Accelerator Options. HP PCIe IO Accelerators for ProLiant Servers. Overview

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview

QuickSpecs. What's New. HP SB40c Storage Blade. Overview. Do you need a direct attached or shared storage solution within your BladeSystem enclosure?

QuickSpecs. What's New. Models. HP SATA Hard Drives. Overview. HP 6G SATA SmartDrive Carriers

QuickSpecs. What's New 300GB 6G SAS 15K rpm SFF (2.5in) Enterprise Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives.

QuickSpecs. What's New HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

QuickSpecs. HP 50 Modular Smart Array Enclosure. Overview

HP ProLiant m300 1P C2750 CPU 32GB Configure-to-order Server Cartridge B21

QuickSpecs. Models. HP StorageWorks Modular Smart Array 30 Multi-Initiator (MSA30 MI) Enclosure. Overview

QuickSpecs. Integrated NC7782 Gigabit Dual Port PCI-X LOM. Overview

HP ProLiant ML370 G4 Storage Server

QuickSpecs. What's New New 146GB Pluggable Ultra320 SCSI 15,000 rpm Universal Hard Drive. HP SCSI Ultra320 Hard Drive Option Kits (Servers) Overview

QuickSpecs HP Disk System 2120

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter

QuickSpecs. HP PCIe IO Accelerators for ProLiant Servers. Overview

QuickSpecs. HP IP Console Switch with Virtual Media Overview

QuickSpecs. HP Server Console Switches Overview

QuickSpecs. What's New HP 120GB 1.5Gb/s SATA 5400 rpm SFF HDD. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview

QuickSpecs. HPE SATA Hard Drives. Overview. HPE Hard Disk Drives

QuickSpecs. Models HP SC11Xe Host Bus Adapter B21. HP SC11Xe Host Bus Adapter. Overview

Retired. HP NC7771 PCI-X 1000T Gigabit Server Adapter Overview

Retired. ProLiant iscsi Acceleration Software Pack for Embedded Multifunction Server Adapters Overview

StorageWorks Dual Channel 4Gb, PCI-X-to-Fibre Channel Host Bus Adapter for Windows and Linux (Emulex LP11002)

HP 9.5mm SATA DVD RW Optical Drive

What's New Smart Array P440 controller complies with FIPS cryptographic module requirements

QuickSpecs. HP Smart Storage Administrator. Overview. Retired

QuickSpecs. HPE Smart Array E208i-p SR Gen10 Controller. Overview

QuickSpecs. HPE Smart Array P204i-b SR Gen10 Controller. Overview

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD ROM Optical Drive. Overview

QuickSpecs. Models ProLiant Cluster F200 for the Entry Level SAN. Overview

QuickSpecs. What's New. Models. Overview

QuickSpecs. Models. HP NC110T PCI Express Gigabit Server Adapter. Overview. Retired

HP SATA DVD RW Optical Drives Overview. HP 9.5mm SATA DVD RW Optical Drive

QuickSpecs. ProLiant Cluster F500 for the Enterprise SAN. Overview. Retired

Retired. Models HP NC340T PCI-X 4-port 1000T Gigabit Server Adapter B21

HPE HDD portfolio: Proven performance for every workload Class Enterprise Midline Entry* Workload High Medium Low

Retired. For more information on HP's ProLiant Security Server visit:

NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510F adapter. HP NC510F PCIe 10 Gigabit Server Adapter

QuickSpecs. What's New Updating list of supported servers. HP Half-Height SATA DVD RW Optical Drive. Overview

QuickSpecs. What's New. HP Smart Array P822 Controller. Overview. Retired

QuickSpecs HP Insight with Microsoft System Center Essentials 2010

QuickSpecs. What's New. HP Solid State Drives (SSD) Overview

QuickSpecs HP Power Manager 4.2

QuickSpecs. HPE SAS Expander Card. Overview. What's New Updating supported hard drives. Models

QuickSpecs. What's New. HP 70 Modular Smart Array. Overview. Retired

HPE HDD portfolio: Proven performance for every workload Class Enterprise Midline Entry* Workload High Medium Low

QuickSpecs. What's New Support for HP software and hardware server support. Models. HP Insight Server Migration software for ProLiant v.3.

QuickSpecs HP Insight Rapid Deployment software 6.0

Retired. Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers) Overview. Models HP 8X/24X SlimLine DVD-ROM Drive B21

ProLiant DL F100 Integrated Cluster Solutions and Non-Integrated Cluster Bundle Configurations. Configurations

QuickSpecs. Models. HP StorageWorks 8Gb PCIe FC HBAs Overview

Transcription:

Overview The Smart Array 642 Controller (SA-642) is a 64-bit, 133-MHz PCI-X, dual channel, SCSI array controller for entry-level hardwarebased fault tolerance. Utilizing both SCSI channels of the SA-642 allows you to configure up to 6 internal and 14 external hard drives to store up to 6 TB of storage. The 64MB and 128MB BBWC (Battery Backed Write Cache) Enabler upgrade allows the SA-642 controller an option to add transportable BBWC for improved controller performance and increases the total controller memory, up to 192MB. The SA-642 also features complete data compatibility with previous generation's Smart Array controllers to ease data migration from server to server and for easy controller upgradeability. Models Smart Array 642 Controller Smart Array 642 Controller 291967-B21 DA - 12069 Worldwide Version 16 September 15, 2009 Page 1

Standard Features The Smart Array Advantage HP's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HP Smart Array family brings an unparalleled return on investment through: Data Compatibility among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of Smart Array controllers understand the data format of other Smart Array Controllers. Consistent Configuration and Management Tools. All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HP server storage. Universal Hard Drive form factor is for use across multiple HP servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives. Pre-Failure Warranty means HP Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your HP Server documentation. Key Features Compatibility with all Ultra320, Ultra3 and Ultra2 LVD family products. In addition, a seamless upgrade to next generation HP high performance and high capacity mainstream Ultra320 Smart Array controllers. Recovery ROM protects against a ROM corruption. Ultra320 SCSI technology delivers high performance and data bandwidth up to 320-MB/s bandwidth per channel. Modular, easy-to-upgrade design lets you optimize performance as needed with the 64MB and 128MB BBWC Enabler, from 64-MB of memory for RAID and read cache to up to 128-MB of BBWC. Mix-and-match LVD SCSI compatibility protects your investments and lets you deploy drives as needed. Software consistency among all Smart Array family products: Array Configuration Utility, Insight Manager (CIM), Array Diagnostic Utility (ADU) and SmartStart. 64-bit, 133-MHz PCI-X interface boosts bandwidth above 1B/s burst transfer rate over PCI-X bus. 64-bit memory addressing supports servers with greater than 4 GB of memory. 64-MB memory optimizes performance and data throughput. NOTE: 64 MB of DDR memory used for RAID and read cache. Online Management Features Online Capacity Expansion Online RAID Level Migration Online Stripe Size Migration Online Spares (Global) User Selectable Expand and Rebuild Priority Channels Dual Channel: Provides the ability to support up to 20 (6 internal, 14 external) drives or 6.0 TB DA - 12069 Worldwide Version 16 September 15, 2009 Page 2

Standard Features Key Features for 64MB BBWC (Battery-Backed Write Cache) Enabler Battery-backed Cache protects cached data in the event of a power outage, server failure or controller failure. 72 hours of battery charge protects the data for an entire weekend. 3 years of battery life. Modular, easy-to-upgrade design lets you optimize performance as needed with the 64MB BBWC Enabler, from 64-MB of memory for RAID and read cache to 128-MB of memory for RAID, read cache, and BBWC. Key Features for 128-MB BBWC (Battery-Backed Write Cache) Enabler The 128MB BBWC Enabler is a transportable 128MB battery module increasing the total memory of the controller to 192MB for RAID, read cache, and BBWC. The transportability of the battery memory module protects the write cache data from unexpected power loss, system board failure, or controller board failure. Data retained in the write cache will be protected for up to 72 hours, allowing time to restore power, or transport the module to a functioning system board or array controller. The modular design of the battery memory module is transportable between the Smart Array 641 and Smart Array 642 controllers. 128MB BBWC (Battery Backed Write Cache) Enabler allows the 642 controllers an option to add transportable BBWC for improved controller performance and increases the total controller memory to 192MB. Data Compatibility Data compatibility among all models of Smart Array Controllers means customers can instantly upgrade their Smart Array products to get to higher performance, capacity and availability. Unlike competitive products, successive generations of Smart Array products understand the data format of other Smart Array controllers, providing investment protection for your HP storage solution. Performance HP's High Performance Architecture sets new boundaries of industry performance expectations! Ultra320 SCSI (320 MB/s bandwidth) per channel High-performance 64-bit architecture 64-bit, 133-MHz PCI-X bus (1033 MB/s bandwidth) Capacity Given the internal server storage need for rapid capacity expansion, the SA-642 offers: Dual SCSI channels support up to 20 (6 internal, 14 external) disk drives Up to 6.0TB of storage per PCI slot Availability Provides increased server uptime by providing advanced storage functionality: Online RAID Level Migration (between any RAID level) Online Capacity Expansion Logical Drive Capacity Extension Global Online Spare Pre-Failure Warranty DA - 12069 Worldwide Version 16 September 15, 2009 Page 3

Standard Features Fault Prevention The following features offer detection of possible failures before they occur, allowing preventive action to be taken: S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at Compaq detects possible hard disk failure before it occurs, allowing replacement of the component before failure occurs. Drive Parameter Tracking monitors drive operational parameters, predicting failure and notifying the administrator. Dynamic Sector Repairing continually performs background surface scans on the hard disk drives during inactive periods and automatically remaps bad sectors, ensuring data integrity. Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure preventative maintenance. Environment Tracking for External Storage System: Monitors fan speed and cabinet temperature of ProLiant Storage System and newer HP storage enclosures. Fault Tolerance Keeps data available and server running while a failed drive is being replaced; several fault tolerance configurations are supported including: Distributed Data Guarding (RAID 5): This allocates parity data across multiple drives and allows simultaneous write operations. It is recommended for up to 14 hard drives. Drive Mirroring (RAID 1, 1+0): This allocates half of the drive array to data and the other half to mirrored data, providing two copies of every file. It is a high-performance RAID. Fault Recovery Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure Recovery ROM: This new feature provides a unique redundancy feature that protects from a ROM image corruption. A new version of firmware can be flashed to the ROM while the controller maintains the last known working version of firmware. If the firmware becomes corrupt, the controller will revert back to the previous version of firmware and continue operating. This reduces the risk of flashing firmware to the controller. On-Line Spares: Up to two spare drives can be installed prior to drive failure. If a failure occurs, recovery begins with an On-Line Spare and data is reconstructed automatically. NOTE: On-Line Spares can only be used with RAID level 1, 1+0, and 5. Ease of Use Consistency and Upgradeability make the Smart Array family unique in the industry: GUI based configuration, management and diagnostic software tools Common data format between generations of products Data migration between servers and external storage enclosures DA - 12069 Worldwide Version 16 September 15, 2009 Page 4

QuickSpecs Compatibility Servers Compatibility For up to date compatibility, please see the following URL for complete Smart Array 642 Controller compatibility and support information: http://h18006.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html Operating Systems Microsoft Windows Server Microsoft Windows Server Hyper-V Red Hat Enterprise Linux (RHEL) SUSE Linux Enterprise Server (SLES) Oracle Enterprise Linux (OEL) Solaris 10 for x86/x64 based Systems VMware For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server and Smart Array RAID controller, please visit our Support Matrix at: http://www.hp.com/go/ossupport NOTE: For more Linux OS support & certification information, please visit: ProLiant & BladeSystem Server Linux matrix http://h18004.www1.hp.com/products/servers/linux/ Integrity & BladeSystem Server Linux matrix http://h71028.www7.hp.com/enterprise/cache/321101-0-0-0-121.html Software Suite All Smart Array products share a common set of configuration, management and diagnostic tools, including Array Configuration Utility, Array Diagnostic Utility (ADU), and Insight Manager. This software consistency of tools reduces the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain the HP server storage. Insight Manager Powerful server and server options/storage manager tool Monitors over 1200 server parameters Configuration/Diagnostic Utilities HP Array Configuration Utility (ACU) Powerful Web based configuration utility for all Smart Array controllers Provides a graphical view of HP drive array configurations Allows for management of multiple arrays over a secure internet connection from anywhere in the world Easy to use Wizards for configuration Runs online on Windows and NetWare HP Options ROM Configuration for Arrays (ORCA) Rapid configuration during initial install of the OS HP Array Diagnostic Utility (ADU) Powerful diagnostic utility for all Smart Array controllers DA - 12069 Worldwide Version 16 September 15, 2009 Page 5

Service and Support, HP Care Pack, and Warranty Information Warranty Maximum: The remaining warranty of the HP server product in which it is installed (to a maximum threeyear limited warranty) Minimum: One-year, on-site limited warranty Pre-Failure Warranty: Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HP Support Center or refer to your HP Server Documentation. Software Product Services Standalone telephone support Rights to new license version Media and documentation updates Hardware Product Services Installation services On-site maintenance (includes warranty support) Response time upgrades during the warranty period Post-warranty coverage RAID setup and performance consulting via statement of work For additional hardware installation and maintenance information, please refer to the URL: http://www.hp.com/hps/hardware/ Warranty Upgrade Options Response - Upgrade on-site response from next business day to same day 4 hours Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days Duration - Select duration of coverage for a period of 1, 3, or 5 years HP Care Pack Information HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage. HP Care Pack is not available for less than the product's warranty duration. HP Care Pack is available for sale anytime during the warranty period for most products, but the commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required. HP Care Pack services are prepaid. For additional HP Care Pack (hardware & software) information, as well as orderable part numbers, please refer to the URL http://www.hp.com/hps/carepack/ DA - 12069 Worldwide Version 16 September 15, 2009 Page 6

Related Options NOTE: This is a list of supported options; note that some options may be discontinued. Optional Upgrades 128-MB BBWC (Battery-Backed Write Cache) Enabler 351580-B21 Hard Drives 10,000 RPM Universal Hard Drive HP 300GB U320 10K Universal HDD 350964-B22 HP 146GB U320 10K Universal HDD 286716-B22 HP 72GB U320 10K Universal HDD 286714-B22 15,000 RPM Universal Hard Drive HP 300GB U320 15K Universal HDD 411089-B22 HP 146GB U320 15K Universal HDD 347708-B22 HP 72GB U320 15K Universal HDD 286778-B22 HP 36GB U320 15K Universal HDD 286776-B22 Universal Hot Plug Tape Drives HP StorageWorks DAT 40 SCSI Hot-plug Tape Drive (Carbon) HP StorageWorks DAT 72 SCSI Hot-plug Tape Drive (Carbon) Q1546A Q1529A Related Smart Array Products HP Smart Array 6i Controller NOTE: The Smart Array 6i Controller ships integrated on several HP ProLiant servers. Please see the Smart Array 6i Controller QuickSpecs for details at: http://h18000.www1.hp.com/products/quickspecs/12030_div/12030_div.html HP Smart Array 6402/128 Controller 273915-B21 HP Smart Array 6404/256 Controller 273914-B21 N/A DA - 12069 Worldwide Version 16 September 15, 2009 Page 7

Technical Specifications Dimensions 12.3 x 4.2 x 0.6 in (31.24 x 10.7 x 1.5 cm) Protocol Ultra320 SCSI SCSI Electrical Interface Low Voltage Differential (LVD) Drives Supported Up to 20 (6 internal and 14 external) Ultra320, Ultra3 and Ultra2 SCSI hard drives SCSI Port Connectors SA- One external one internal SCSI port 642 Data Transfer Method 64-Bit PCI bus-master PCI Bus Speed 64-bit, 133-MHz PCI-X (1 GB/s maximum bandwidth) PCI 3.3 volt CPI slot compatibility only Simultaneous Drive Two Transfer Channels Channel Transfer Rate 640 MB/s total; 320 MB/s per channel Software upgradeable Yes Firmware Cache Memory 64 MB of DDR memory used for RAID and read cache Logical Drives Supported 32 Maximum Capacity 6.0TB (20 x 300GB U320 SCSI Hard Drive) Memory Addressing 64-bit, supporting servers memory greater than 4 GB RAID Support RAID 5 (Distributed Data Guarding) RAID 1+0 (Striping and Mirroring) RAID 1 (Mirroring) RAID 0 (Stripping) Upgradeable Firmware 2-MB Flashable ROM Disk Drive and Enclosure Ultra2, Ultra3, and Ultra320 Protocol Support 64-MB BBWC Enabler Dimensions (HxWxD) Cache Memory Cache Batteries 3.5 x 1.8 x 0.54 in (8.89 x 4.6 x 1.37 cm) 64 MB of DDR memory for RAID, read cache, and BBWC: ECC protection, battery-backed, and removable Up to 3 days of battery life, removable for easy replacement 128-MB BBWC Enabler Dimensions (HxWxD) Cache Memory Cache Batteries 3.5 x 1.8 x.54 in (8.89 x 4.6 x 1.37 cm) 128 MB of DDR memory for RAID, read cache, and BBWC: ECC protection, battery-backed, and removable Up to 3 days of battery life, removable for easy replacement DA - 12069 Worldwide Version 16 September 15, 2009 Page 8

Technical Specifications Environment-friendly Products and Approach End-of-life Management and Recycling Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to http://www.hp.com/go/green. To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office. Products returned to HP will be recycled, recovered or disposed of in a responsible manner. The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities. This information (product disassembly instructions) is posted on the Hewlett Packard web site at: http://www.hp.com/go/green. These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment. Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less. DA - 12069 Worldwide Version 16 September 15, 2009 Page 9