Product and functional description

Similar documents
Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and functional description

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Product and functional description

Product and functional description

Push Button Interface UP 220D31

Product and functional description

Push button UP 287, 4 - fold

Product and functional description

Product and function description

Product and Application Description

584 5WG AB_1 DELTA

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

252F 5WG FB_1 DELTA

DELTA profil wall switch, single UP 241/2 5WG AB_2

Product and Applications Description

DELTA i-system wall switch single UP 221/2 5WG AB_2

Operating and mounting instructions

Product and Application Description

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Product and Function Description

Weather station AP 257/51

Product and function description

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Extension module for lighting control

Electrical devices may only be mounted and connected by electrically skilled persons.

Operating voltage Maximum

DALI Professional Controller-4. Control unit Operating instructions

Weather station GPS AP 257/61 Weather station AP 257/51

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

DELTA i system wall switch single UP 221/2 5WG DB_2. wall switch double UP 222/2, 5WG DB_2. wall switch triple UP 223/2, 5WG DB_2

UNIVERSAL DIMMER DIM02SA/500U

Power supply module, bus connection module

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

6173 AG GJB A0138

Operating instructions only for authorized, skilled electricians with EIB training

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

Electrical Actuators

Electrical Actuators

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Super universal modules

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

Miniature Circuit Breakers for Railway Applications

Operating Instructions. DALI-Gateway

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Demonstration Case BENNING DB 1

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Digital input modules

Rotary version, three-position control

Operating Instructions VEGAMET 381

Operating instructions. Speed monitor D / / 2014

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

ETD-BL-1T-OFF-CC- 10S

Operating instructions. Switching amplifier DN0210 DN / / 2015

ABB i-bus KNX Binary Inputs BE/S Product Manual

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

Siemens Drives & PLCs

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Electrical Actuators

Status display unit with P-bus connection

Overvoltage Protection Devices

Products no longer available

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

RM35LM33MW liquid level control relay RM35-L V AC/DC

Four-channel Venetian blind actuator 230 V Installation Instructions

GS202 Encoder Switch

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

LED Driver DC-String

Product documentation

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

LED Driver DC-String

Product documentation

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

TXM1.8RB. TX-I/O Blinds module

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Installation Instructions

LED Driver DC-String

Transcription:

Product and functional description The instabus / DAI gateway 141 is a KX EIB device with one DAI output to which up to 64 DAI actuators (e.g. DAI ballasts) can be connected to. It is not allowed to connect DAI sensors to the output of the 141. DAI (Digital Addressable ighting Interface) is a bidirectional communications interface in accordance with IEC 60929, whose specification has been defined by manufacturers of electronic ballasts. It not only enables the receipt of e.g. switching and dimming commands but also the sending of status information such as the failure of a lamp or the report of a detected error in the electronic ballast. According to IEC 60929 up to 64 DAI devices can be connected to a DAI bus line and can each be assigned an individual device address. for switching On the Direct mode as well as for switching back to the Bus mode. When this pushbutton has been pressed for the first time the yellow ED lights up permanently to indicate direct mode. Then all lamps controlled over the DAI bus can be together switched On or Off via the relevant two pushbuttons on the front plate of the gateway such as via a bus pushbutton: pressing the upper pushbutton briefly switches the channel On while pressing the lower push button briefly switches the channel. A red ED integrated in the upper push button is used to indicate the state of the lamps by a continuous light and to indicate an error (e.g. a DAI bus, ballast or lamp failure) by flashing. If the direct mode button is pressed for a second time, the yellow ED to indicate direct mode is extinguished and the 141 is switched to Bus mode. ote: If individual communication with each individual DAI device is not required and you wish for example to simply connect a group of dimmable fluorescent lamps in parallel and control them in the same way as you would previously have connected and controlled dimmable electronic control gear (ECG) with a 1...10 V interface, this is also possible with the switch/dimming actuator 525E. Status and error signals are also detected by the 525E and transmitted, whereby these signals are assigned to the respective group and not to an individual DAI device. Application program 25 CO instabus / DAI Gateway 802701 The instabus / DAIGateway 141 can be used to control up to 64 DAI devices over the EIB. They can be switched and dimmed either individually or in groups. The 141 also enables the detection and transmission of DAI status and failure information. An individual name, a group, scenes and parameters (refer to the application program description) are allocated to the individual DAI electronic ballasts during commissioning with the ETS (Engineering Tool Software). The power supply unit integrated in the 141 supplies the gateway electronics and generates the DAI bus voltage. Additionally it enables the operation of the gateway and a direct switching of all lamps controlled over its DAI output even if the 141 has not yet been commissioned with the ETS or if the communication via the EIB has been interrupted. For this purpose, the 141 has a pushbutton located bottom left on its front plate Siemens AG 141, 5 pages Technical manual 2.5.3.1/1

Versorgung supply AC 230 V Busankoppler bus coupling unit Versorgung supply AC 230 V DAI GAMMA instabus Connection example instabus EIB instabus / DAI Gateway 141 AC 230V DAI EVG DAI ECG 1 DAI euchtstofflampe fluorescent lamp DAI EVG DAI ECG 64 DAI euchtstofflampe fluorescent lamp Installation notes The device can be used for permanent installation in dry, interior rooms and for insertion in distribution boards or miniature housings. V WARIG The device must be mounted and commissioned by an authorised electrician. Unoccupied sections of DI rail with data rail inserted must be protected with the cover 5WG1 1928AA01. When connecting the device, it should be ensured that the device can be isolated. The device may not be opened. When planning and installing electrical installations, the relevant guidelines, regulations and specifications of the respective country must be observed. Technical data Power supply EIB Bus voltage: carried out via the bus line EIB bus current: 5 ma (only half a standard bus load! ) Electronics and DAI output: integrated power supply for AC/DC 110240 V, 5060 Hz power consumption: max. 7 W Inputs/outputs Mains connection: 3pole (,, ) DAI output (according to IEC 60929): max. 64 DAI devices with > 8 kohm input impedance DAI bus voltage: approx. DC 19 V, floating, shortcircuitproof Operating elements 1 learning push button: for toggling between normal mode / addressing mode 1 push button: for toggling between bus mode / direct mode 2 push buttons: for switching all electronic ballasts O / OFF Display elements 1 red ED: for checking the bus voltage and for displaying normal mode / addressing mode 1 green ED: for displaying the 230 V operating voltage 1 yellow ED: for displaying direct mode / bus mode 1 red ED per push button: for O / OFF status indication (only in direct mode) and failure indication by blinking with 1 Hz (communication or illuminant fairlure) Connections Plugin terminals for mains voltage and DAI output, insulation strip length 10... 11 mm The following conductor crosssections are permitted: 0.5... 3.3 mm 2 (AWG 12) singlecore 0.5... 3.3 mm 2 (AWG 12) stranded multicore 0.5... 3.3 mm² (AWG 12) finely stranded, untreated 0.5... 1.5 mm 2 finely stranded, with connector sleeve The supply cable to the 141 must be fused with a circuitbreaker of characteristic B or C for a max. nominal current of 6 A! EIB Bus line: Pressure contacts on data rail and bus terminal Mechanical data Housing: plastic Dimensions: DI rail mounted device in system dimensions, width: 4 module units (1 module unit = 18 mm) Technical manual 141, 5 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2007 Electrical Installation Technology 2.5.3.1/2

Weight: approx. 150 g Fire load: approx. 3400 kj Installation: Snapon mounting on DI rail E 60715TH357.50 Electrical safety Degree of pollution (according to IEC 606641): 2 Protection type (in accordance with E 60529): IP 20 Overvoltage category (according to IEC 606641): III Bus: safety extralow voltage SEV DC 24 V Device complies with: E 5009022 and E 6066921 EMC requirements Complies with E 5009022 Environmental conditions Climatic withstand capability: E 5009022 Ambient operating temperature: 5... 45 C Storage temperature: 25... 70 C Relative humidity (not condensing): 5 % to 93 % Markings KX EIB CE mark In accordance with the EMC guideline (residential and functional buildings), low voltage guideline ocation and function of the display and operating elements A5 A10 A9 A8 A6 A1 Figure 1: ocation of the display and operating elements A1 Button for toggling between normal / addressing mode for transferring the physical address A2 ED (red) for displaying normal mode (ED off) or addressing mode (ED on); it is automatically extinguished once the physical address has been transferred A3 Plug for bus connecting terminal A4 Pushbuttons for direct operation (all lamps On / Off) A5 Red ED direct mode: status all lamps (On/Off) display DAI failure flash times approx. 1s break flash times = 1: > 230V connect to DAI Input! = 2: > shorted DAI cable! = 3: > low DAI voltage! = 4: > no DAI device connected! A6 Terminals for the DAI bus cable (D, D) A7 Terminals for protective earth, neutral and phase conductor (,, ) A8 ED (yellow) for displaying when direct mode = On A9 Button for toggling between bus / direct mode A10 ED (green) for displaying the operating voltage A2 A3 A4 A7 Siemens AG 141, 5 pages Technical manual 2.5.3.1/3

Installation and wiring General description The DI rail mounted device in system dimensions (width 4 module units) can be inserted in distribution boards, surface or flushmounted and wherever DI rails E 5002235 x 7.5 are available. The connection with the bus line is either carried out via a bus terminal or via the contact system to the data rail. Installing the DI rail mounted device (Figure 2) Suspend the DI rail mounted device (B1) on the DI rail (B2) and Rotate the DI rail mounted device backwards until the slide switch audibly clicks into position. Dismantling the DI rail mounted device (Diagram 2) Remove all the connected cables, press the slide switch (C3) downwards with a screwdriver and remove the DI rail mounted device (C1) from the DI rail (C2) with a swivel action. Connecting the bus cable (Figure 3) The bus terminal () is suitable for singlecore conductors with 0.6... 0.8 mm Ø. Strip approx. 5 mm of insulation from the conductor (.4) and plug in the terminal () (red=, black=). Disconnecting the bus cable (Figure 3) Remove the bus terminal () and the conductor (.4) out of the bus cable by rotating it backwards and forwards. D1.1.2.3.4 5 mm B2 C2 B1 C1 Figure 2: Installing / dismantling the DI rail mounted device Removing the bus terminal (Figure 3) The bus terminal is located on the top of the 525E (D1) The bus terminal () consists of two sections (.1,.2), each with four terminal contacts. Care should be taken not to damage the two test sockets (.3), either by accidentally connecting them to the bus conductor or with the screwdriver (when trying to remove the bus terminal). Carefully insert the screwdriver in the wire entry slot underneath the bus terminal () and pull the bus terminal forwards out of the 525E (D1). ote: Care should be taken as there is a risk of shorting the device! Connecting the bus terminal (Figure 3) Place the bus terminal in the guide slot and press the bus terminal () backwards until it reaches the stop. C3.4 Figure 3: Connecting and disconnecting the cable Connecting mains voltage and DAI bus cables The connections are designed with plugin technology. Strip approx. 1011 mm of insulation from the conductors and slide in the respective terminal. Crosssections: The following conductor crosssections are permitted: 0.5... 3.3 mm2 (AWG 12) singlecore 0.5... 3.3 mm2 (AWG 12) stranded multicore 0.5... 3.3 mm² (AWG 12) finely stranded, untreated 0.5... 1.5 mm2 finely stranded, with connector sleeve The mains connection must be fused with a circuitbreaker of characteristic B or C with a max. nominal current of 6 A! Mounting the insulating cap If the device should be mounted on a DI rail without a data rail, the contact system must be covered with the supplied insulating cap. Removing the locating clamp (Figure 4) The locating clamp (E3) encloses the contact system (E2) on the rear of the DI rail mounted device (E1). Insert the screwdriver between the DI rail mounted device (E1) and the locating clamp (E3) and remove the clamp. Technical manual 141, 5 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2007 Electrical Installation Technology 2.5.3.1/4

Clipping on the insulating cap: (Figure 4) Place the insulating cap (E4) on the contact system and press so that it snaps in place. E3 E1 E2 E2 E4 E1 Figure 4: Covering the contact system Dimension drawing Dimensions in mm 90 45 b b = 4 module units 44 55 (1 module unit = 18 mm) General notes Any faulty devices should be returned to the local Siemens office. If you have further questions about the product, please contact our Technical Support: 49 (0) 180 50 50222 " 49 (0) 180 50 50223! www.siemens.com/automation/supportrequest Siemens AG 141, 5 pages Technical manual 2.5.3.1/5