AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

Similar documents
AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

AS-i Safety Output Module, IP20

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Digital Modules AS-i in IP20, 22,5 mm

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i Safety Input Modules (M12), IP67

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

AS-i Safety Analog Input Module, IP20

Active Distributors AS-i Safety, Active Distributors AS-i

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Analog Modules AS-i, IP67, M12

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Digital Modules AS-i, IP67, M12

Active Distributors ASi Safety, IP67

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i 3.0 Motor modules

AS-i Safety Relay Output Module with Diagnostic Slave

Analog Modules AS-i IP65, M12

AS-i 3.0 motor module

PCB AS-i modules, board based solutions

AS-i 3.0 motor modules

System manual AS-i safety monitor AC041S /00 05/2013

MSR178DP. Description. Features. Specifications

Making Hazardous Operations Safe and Productive

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

Operating instructions Memory plug E /02 11/2011

XPSMCMDO Digital output pairs expansion modules with screw term

Installation Instructions Temperature transmitter TAA /00 06/2011

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Multiturn absolute encoder

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Phone: Fax: Web: -

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

CONFIGURABLE SAFETY RELAYS

XPSMCMMX inputs 2 output pairs expansion module with screw term

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

E-STOP relays, safety gate monitors

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

AS-Interface Safety at Work

HR1S-AC Safety Relay Modules

ASI SAFETY & MESUREMENT. SG4-FINGER SERIES. APPlICATIONS

Non-Contact Safety System CES-AZ

Original operating instructions Safety relay with relay outputs G1501S / / 2016

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

Light Curtains. Type 4 SG4. Type 4 SG4 Series. 468

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

XPSMCMDI Input expansion module with screw term

Operating instructions AC010S Compact AS-i E-STOP safety module

MSR42 Micro 400 Controller/Muting Module

Safe timer relay/contact expansion modules

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Sensor boxes SRBG Key features

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES

Compact Coded Magnetic Safety Interlock Switch and Control Units

PSR UC/ESAM4/3X1/1X2/B

SAFETY & MESUREMENT SFIN A GER F OT T PR E. TION light CURTAINS EC Y SG4-FINGER SERIES. highlights

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Safe monitoring relays

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

E-STOP relays, safety gate monitors

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Operating instructions Programming and display unit PP / / 2010

Cube67 - Modular I/O station

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg.

Faults on the system Proximity switch connection technology:

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

Transcription:

ext. in ext. in Safety Output Module with Safety and standard I/O in one module Electronic safety output Additional 3 standard inputs, 1 EDM input, 2 outputs IEC 61508 SIL 3, EN ISO 13849-1 PLe Cat 4, EN 62061 SIL 3 Protection category IP20 The stainless steel Safety Monitor controls the outputs of the Safety Output Module by using a safety single address. To set the safety address, the dip-switch has to be in the ON/PRG position. Addressing can then be accomplished by using an addressing device, for example. Several Safety Output Modules can have the same safety address and can be controlled via this same safety address on a circuit. All Safety Output Modules with the same safety address are controlled simultaneously. In addition to the safety single address the module also supports an AB-address used to transmit the states of the standard inputs or of the electronic device monitoring (EDM). Another AB slave is available for diagnostic. : 3 modules in one housing! 1 electronic safety 3 standard Diagnostic and output inputs and 1 EDM input 2 outputs + + = ON RUN ADDR SEL PRG FAULT O 2 PWR O 1 1.14 1.14 ASI+ 2.14 AUX+ 1.14 AS AS 2.14 AUX+ ext. in AUX- ASI- AUXext. in safety address AB address AB address safety address + 2 AB addresses Connection Connection 4 x COMBICON Length of connector cable unlimited (1) Profile Diagnostic slave: S-7.A.E, ID1=5 AB slave: S-7.A.E., ID1=7 Address 1 single slave + 2 AB slaves Required Master profile M3 As of specification 2.1 Operating voltage 3 (18 31.6 V) Max. current consumption < 200 ma AUX Operating voltage 24 V (18 3) Max. current consumption 1 A www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 30.4.15 page 1

Input Number 3 standard, 1 diagnostic + 1 EDM Switching current static 4 ma at 24 V, dynamic 15 ma at 24 V (T = 100 µs) Power supply out of AUX Power supply of max. 100 ma attached sensors External device monitoring (EDM) Output Number Max output current Test pulse supplied out of AUX, approx. 10 ma 2 x output switching elements max. contact load: 0,5 A DC-13 at 24 V 1 A if output is on: minimum interval between 2 test pulses: 250 ms pulse width: 1 ms Display LED I1...In (yellow) state of inputs I1...I3 LED (yellow) state of EDM input LED PWR (green) on: voltage on flashing: voltage on, but peripheral fault (2) or address 0 off: no voltage LED FAULT (red) on: no data exchange (slave address 0 or slave offline) flashing: peripheral fault (2) off: slave online LED O1, O2 (gelb) state of outputs O1, O2 LED yellow (O2) output 2 closed Environment Applied standards IEC 61508 SIL 3 EN 62061 SIL 3 EN ISO 13849-1 PLe Cat 4 Operating altitude max. 2000 m Ambient temperature 0 C... +55 C Storage temperature -25 C... +85 C Housing plastic, for DIN rail mounting Protection category IP20 (EN 60529) Maximum tolerable shock and according to EN 61131-2 vibration stress Insulation voltage 50 Weight 150 g Dimensions 25 / 105 / 114 (W / H / D) in mm (1) loop resistance 150 Ω (2) See table "Peripheral fault indication" Peripheral fault indication Overload sensor supply Output short circuited AUX voltage missing page 2 Mannheim, 30.4.15 We reserve the right to change any data www.bihl-wiedemann.de

24 V Freigabe (Release) F-Logik (F-Logic) Freigabe (Release) Eingänge (Inputs) I3 Ausgänge 1.14 (Outputs) 2.14 Clamps Description I1, I2, I3 standard inputs I1, I2 and I3 1.14 semiconductor output 1 2.14 semiconductor output 2 I-, I+ supply voltage for inputs EDM 1 / input for electronic device monitoring +, network connection AUX+ ext.in, voltage supply input AUX- ext.in + - Programming instructions (bit values of inputs/ouputs, 3I standard inputs and 1 EDM input) Bit output Bit input O0 I0 I1 O1 I1 I2 O2 I2 I3 O3 inexistent I3 Programming instructions (bit values of the diagnostic slave) Bit output Bit input O0 Parameter P1=1 Parameter I0 diagnostic (for definition see table device colors) 1: output O 1 controlled by safety release 0: inhibits output O 1 on irrespective of safety release O1 Parameter P1=1 Parameter I1 1: output O 2 controlled by safety release 0: inhibits output O 2 on irrespective of safety release O2 I2 O3 inexistent I3 Parameter P2=0 Parameter P2=1 Peripheral fault indicates unavailable 24 V ext. 1: feedback for user: safety release on 0: feedback for user: safety release off Diagnostic (device colors) Value Color Description State change LED "Out" 0 green output on on 1 green flashing 2 yellow restart inhibit auxiliary signal 2 1 Hz 3 yellow flashing 4 red output off off 5 red flashing waiting for "reset of error condition" auxiliary signal 1 8 Hz 6 gray internal error, such as "fatal error" only via "Power On" on device all LEDs flashing 7 green/yellow output released, but not switched on switching-on by setting of O1 off www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 30.4.15 page 3

Programming instructions (bit values of the parameter, diagnostic slave) Bit P1 P1=1 safe output controlled by safety release only safe output controlled by output O0=1 and O1=1 in addition to safety release Bit P2 P2=1 feedback for user: release on bit I3 P2=0 input at bit I3 Bits P0, P3: Release parameter (AB slave) changes the function of output bit O0 and O1 Parameter P1=1 (default) O0=0 P1=1 O0=1 O0=0 O0=1 P1=1 (default) O1=0 P1=1 O1=1 O1=0 O1=1 Safety Output Module, safety release from the safety monitor... not received... received LEDs State Signal / Description no operating voltage PWR (green) 1Hz operating voltage present, safety-related address and/or AB address is 0 or no 24V ext. in (auxiliary power) or overload sensor supply operating voltage present FAULT (red) communication OK no data exchange with at least one AB slave no 24V ext. in (auxiliary power) or overload sensor supply semiconductor output open O1, O2 (yellow) 1Hz 8Hz restart inhibit, waiting for the start signal, the semiconductor output switches on after the start signal device is in unlockable error state; waiting for "reset of error condition signal"; after receiving this signal the device follows up with normal operation semiconductor output closed page 4 Mannheim, 30.4.15 We reserve the right to change any data www.bihl-wiedemann.de

LEDs State Signal / Description the corresponding input is not connected I1, I2, I3, (yellow) the corresponding input is connected (running light) switch is adjust to ON/PRG position LED on LED flashing LED off In case all LEDs are blinking simultaneously in fast rhythm a fatal error has been detected. This message is reset by a short-run disconnection of the power supply (Power On Reset). Accessories: Safe contact expander, 1 or 2 independent channels (art. no. BWU2548 / BWU2539) www.bihl-wiedemann.de We reserve the right to change any data Mannheim, 30.4.15 page 5