SCADAPack ES. Smart RTU

Similar documents
SCADAPack ES. Smart RTU

SCADAPack 530E 535E. remote Programmable Automation Controller

SCADAPack 350E 357E. Smart Remote Terminal Unit

SCADAPack Smart RTU

SCADAPack 312E 313E. Smart RTUs for water

SCADAPack 32. Smart RTU

SCADAPack 330E 333E 334E 337E

SCADAPack ES Hardware Manual

SCADAPack 312E 313E 314E

SCADAPack 350E 357E. Smart Remote Terminal Units. Distributed by Relevant Solutions relevantsolutions.com

SCADAPack Modbus multivariable transmitter

Remote Terminal Unit ER1000 APPLICATION FEATURES

SCADAPack 330E 334E. Smart RTU

SCADAPack. I/O Expansion & Communication Modules

MINER-S Station Controller. Substation Automation

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

SAGE A powerful distribution automation platform with all the functionality of a gateway. Make the most of your energy SM

SCADAPack FlowStation 110. Pump station controller

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

SCADAPack 50. Wireless Remote Data Logger

MINER-S Station Controller

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

SCADAPack Modbus multivariable transmitter

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

NTX Series Product Comparison

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

UA-5200 IIoT Communication Server

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

General information. Display. Supply voltage. Input current

SCADAPack Vision. Operator interface terminal. Vision10 Vision60

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

FEATURES DESCRIPTION FEATURES

Features and Benefits. Certifications

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

Programmable Logic Controllers Micro850

Momentum 171 CCC Processor with Ethernet Communication Port

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

iologik 2500 HSPA/GPRS/WLAN Series

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

TALON Network Manager- 2 & 6 Express

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Communication Gateway COM 610. Product Guide

XP-8346-CE6 XP-8346-CE6-PRO

I/A Series HARDWARE Product Specifications

CPU 1214C. Overview. Design. The compact CPU 1214C has:

Features and Benefits. Certifications

iologik E1200H Series

VersaMax Micro and Nano Technical Product Presentation

IMIO100 IMIO105. DDC controllers. Summary

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Features and Benefits. Certifications

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Scout-S Station Controller

UA Series IIoT Communication Server

Z-PC Line Z-RTU. User Guide

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ControlWave PAC Process Automation Controller

Gas Controller System DGC-06

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

General information. Display. Supply voltage. Input current. Encoder supply. Output current

RTU32E. Data Sheet Doc: v1.03 / October 14 th, 2014

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

LBVR1718. Description. Features channel paperless recorder

MIC-2 MKII, Multi-instrument DATA SHEET

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

TM258LF42DT compact base M I/O - 24 V DC - CANopen

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Asset Management. Facility Management. Total Solutions. Supply Chain Management. Utilities. Series 4500

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

1. CP430, CP470, CP474, CP770 and CP774

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

RTU32S RTU32S Series Small Compact Utility RTU

FEATURES DESCRIPTION SPECIFICATIONS

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

RTU32S RTU32S Series Small Compact Utility RTU

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

extending the boundaries of technology evolution of proven technology FEATURES

Transcription:

Smart RTU

1 Meeting the demands for high-speed distributed control and automation systems, Schneider Electric offers the SCADAPack ES as an advanced Smart RTU. Our highest performance Smart RTU built on a native DNP3 architecture, the is ideally suited to applications requiring medium to large I/O counts, high speed time stamping and data capture. This product provides 10mS sequence of events (SOE) monitoring capability, two high-speed LAN ports, five serial ports, and support for industry standard protocols including DNP3, Modbus, and IEC60807-5. The offers two userprogrammable applications in the IEC61131-3 programming standard, and is optionally configurable directly from ClearSCADA host software.

Product Data Sheet Specifications 2 Controller Processor Memory Event Logging Capacity Maximum Database Points Temperature Humidity Input Voltage Range Power Requirements Auxiliary Output Supply Communication Ports Protocols Removable Memory Socket Dimensions Digital Inputs Normal Operation Range Sequence of Events Detection Channels Per Common 8 Inversion Debounce Counters Digital Outputs Max switching voltage Max switching load AMD 586 Elan SC520 32-bit embedded processor, 100MHz 128MB SDRAM, 32MB Flash, 2048KB SRAM, 512KB Boot Flash 40,000 events 20,000 typical -40 C (-40 F) to 65 C (150 F) operating, -40 C (-40 F) to 70 C (158 F) storage 10 to 95% RH (non-condensing) 10 to 30VDC 6.3W at 24VDC minimum Add 3.0W with all relays energized Add 6.5W for fully loaded auxiliary power supply Add.72W per analog output Isolated 24VDC 200mA max. (optional) Isolated 10VDC 500mA max. (optional) Isolated 5VDC 1.0A max. (optional, required for I/O Expansion modules or Operator Interface Terminal) Power input and Auxiliary Output are functionally isolated from each other and all IO points Port 0, Port 1 and Port 4: RS-232; Port 2 and Port 3: RS-232/RS-422/RS-485 (software selectable) Ethernet: Dual 10/100Base-T UTP ports (transformer isolated) Note: All RS-232 ports are static protected to ±15kV (IEC 801-2, Air-gap discharge) Modbus, DNP3, Modbus/TCP, TCP/IP (standard) IEC60870-5-103 (serial master), -101 (serial slave), -104 (Ethernet slave) optional Compact Flash 1: buffered, hot-swap capable. Supports up to 4GB card (compact flash card not included) 11.81 inch (300mm) wide, 6.89 inch (175mm) high, 1.57 inch (40mm) deep 16 or 32 inputs 10-30VDC 10mS Specifications continue on the next page State inversion per channel Adjustable per channel 0-40Hz and 0-1kHz counter channels (shared with digital inputs) 8 or 16 outputs Form C SPDT relay, 3-terminal connection (NO/Common/NC), Non-latching 500VAC minimum to RTU electronics 30 VDC, 25VAC 60W / 50VA (2A)

Product Data Sheet Specifications 3 Analog Inputs Resolution Range Analog Outputs Resolution Range Load Range Additional I/O 6 or 12 inputs Unipolar 12-bit, 0.1% of full scale at 77 F (25 C), ±0.3% over temperature range Isolated from channel to channel and from RTU electronics. Analog inputs must be within 50 Vac or 7 VDC of chassis or earth 4-20mA or 1-5V switch selectable 2 or 4 outputs Unipolar 12 bit ±0.1% at 77 F (25 C) with 250ohm load, ±0.5% over temperature range Optical. 500Vac minimum to RTU electronics 4-20mA (voltage output available with external precision resistor) 0-100 ohms with 9V supply 150-1150 ohms with 30V supply I/O Expansion Supported modules: 5304, 5405, 5411, 5505, 5506 and 5606 Certifications Safety Hazardous Locations Support for additional multi-dropped ES Smart RTU, via serial or Ethernet links c(csa)us. CAN/CSA-C22.2 No. 61010-1. Requires the use of SELV power supplies on all power and IO points for compliance Non-Incendive Electrical Equipment for Use in Class I, Division 2 Groups A, B, C and D (optional) Disclaimer: Schneider Electric reserves the right to change product specifications. For more information visit www.schneider-electric.com.

Product Data Sheet Model 4 P500-1A00-AE00 represents a sample code for a with 16 D/I, 8 D/O, 6 A/I and 2 A/O Model Select: Controller P500 Select: Communication Ports 1 3 RS232, 2 RS232/485, 2 Ethernet 10/100 BaseT, 1 Compact Flash socket (compact Flash card sold separately) Select: Processor/Memory A AMD Elan SC520 CPU, 100MHz, 32MB Operating System FLASH, 128MB volatile SDRAM, 2MB Battery Backed SRAM Select: Protocol Option 0 Modbus, DNP3, Modbus/TCP, TCP/IP (included in all Smart RTUs) 1 Adds IEC 60870-5-103 Master, Protection Relay Protocol (for data transmission with IEDs) 2 Adds IEC 60870-5-101/104 Slave, Standard Telecontrol Tasks (allows a 101 Master to communicate with the ES) 3 Adds both - IEC 60870-5-103 Master and IEC 60870-5-101 Slave protocol options Select: Programming Environment & SCADA Security 0 IEC 61131-3 (Executes two IEC 61131-3 kernels, includes E Configurator & extensions, Workbench required) 1 IEC 61131-3 with AGA-12 SCADA Encryption Security Select: License Option A None B DNP3 Data Concentrator License - acts as a DNP master to collect data from multiple slaves C Support of multiple DNP3 Masters (up to 3 Masters) - responds to multiple DNP masters as a slave D DNP3 Data Concentrator and support of multiple DNP3 Masters (up to 3 Masters) Select: I/O D/I D/O A/I A/O (Some I/O Expansion modules supported) B 0 0 0 0 E 16 8 6 2 A 32 16 12 4 Select: Power Supply 0 10-30 Vdc Wide Range Power input, no auxiliary power supply 1 10-30 Vdc Wide Range Power input, auxiliary power supply with 5 Vdc output (required to power Vision Displays) 2 10-30 Vdc Wide Range Power input, auxiliary power supply with 10 Vdc output 3 10-30 Vdc Wide Range Power input, auxiliary power supply with 24 Vdc output Select: Approvals 0 c(csa)us. CAN/CSA-C22.2 No. 61010-1. Approved - Non-Hazardous Locations 1 c(csa)us. CAN/CSA-C22.2 No. 61010-1, Class 1 - Div 2 (Groups A,B,C,D). Approved - Hazardous Locations Select: Custom Options None V Analog Input range set for 1-5v (default range is 4-20mA) C Custom Analog Input Range (specify range) Telemetry & Remote SCADA Solutions www.schneider-electric.com Document Number TBULM01011-34 2011 Schneider Electric. All rights reserved - August 2011