Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Similar documents
QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

GENERAL QUICK START GUIDE

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

Installation Guide. ZKAccess CLASSIC 3.5. www. zkaccess.com

USER MANUAL. BioPro SA50 Fingerprint & Palm Terminal. Version: 1.0 Date: August Inch TFT Terminal User Manual 1

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Installation Guide (ver 1.0)

Zodiac FR100 TM INSTALLATION MANUAL

Fingerprint Access Standalone User s Manual

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

User Manual. Before using this device, read and follow all instructions for safety

SCR100 User Manual. Version:1.1 Date:Dec 2009

ACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:

C5S120 Installation and Connection Guide

CV-945 Stand-Alone Biometric Reader. Installation Instructions

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

iface Series Installation Guide

EX8. User Manual. Ver 1.0

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

Fingerprint Access Control F1. User Manual

USER MANUAL. 4.3-inch Touch Screen & Palm Attendance Terminal. Version: 1.0 Date: August, 2017

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

Quick Start Guide. GV-CS1320 Camera Access Controller

Single Door Standalone Access Control User Manual

Installation Guide (ver 1.0)

ZKAccess3.5 Security System

User Manual. UHF RFID Standalone Terminal. Version: 1.0 Date: December, 2017

User Manual. Split access control with intelligent secured power supply.

Two-door Access Controller

CM-110SK Standalone Keypad Installation Instructions

Facial & Fingerprint Recognition Product

Operation manual For NG BIOSINGLE Version 1.1

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

Installation Guide. UHF RFID Integrated Machine: U1000E, U1000F, U2000E, U2000F. Version: 1.0 Date:

3 inches Facial & Fingerprint Recognition

A-1300 Biometric Access Control System USER'S MANUAL

H2i. s u p p o r f i n g e r t e c. c o m. H2i. Simple Fingerprint Door Access & Time Attendance System. User Guide

Installation & User Manual

EL-ST100 KEYPAD CONTROLLER

This document mainly introduces the windows and operations of the F18 model 2.4 inch color TFT product.

IP based Fingerprint Access Control. Installation Guide.

Digital Keypad Introduction

Standalone Access Control

Waterproof. Keypad/Reader/Controller

Installation & User Manual V2.08

Access control panel U-Prox IC E (Elevator control)

Time Attendance User s Manual

Access Control Integration Host User s Manual

User Manual Version 1.1 Date: March 2012

smartentry Wireless Video Doorphone User Manual

Webpass IP Reader. WEB Configuration Manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input

Manual er under oversettelse til norsk.

W3-H Waterproof Keypad/Reader/Controller

INSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A

TCS Access Control System Cheat Sheet

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

3 inches Facial & Fingerprint Recognition

MANUAL ENGLISH NEDERLANDS DEUTSCH FRANÇAIS ESPAÑOL ITALIANO PORTUGUÊS POLSKI ČESKY SZLOVÁK MAGYAR. SAFESCAN TA-8000 Series TIME ATTENDANCE SYSTEM

User Manual. Applicable Models : X990.

Akcess BioMetrics Corporation. Bio2Touch. Access Control Fingerprint Reader. User's Manual. Akcess BioMetrics Corporation

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

F & SC Serial Access Control Station. Installation Guide

DOLXFD1000B. Waterproof Access Control/Reader

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Version: 1.1 Software Version: For Access 4.5.8/5.0.8 and above Version Date: July, 2011

Quick Start Guide V5.0

BF-630X/BF-830X WEB SCREEN. Access Control/Time Attendance. User s Manual

2000 Series e/em Style Keypad Installation and Programming Manual

User Manual Version 1.1 Date: November 2011

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

ACCESS CONTROL SYSTEM

Face & Fingerprint Recognition Product

Unit Door Station User's Manual ----VTO12XX Series

INSTALLATION GUIDE BioEntry W English Version 2.10 EN BEW V2.10A

Security at Fingertips

ievo ULTIMATE INSTALLATION GUIDE

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

ELITE Test Systems. /Quick Start Wiring. Botron Company Inc.

STONELOCK PRO USER MANUAL Version 2.0

INSTALLATION INSTRUCTION MANUAL

2.4 inch Color Screen Series User Manual

REX F-0-9 Standalone or Access Controller

AIM- DAC System. DAC844 User Manual. Anviz Global Inc

uface800 Time Clock User Manual uface800

iclock Access control Installation

3 Inches Color TFT Serials User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual

Transcription:

Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0

CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7 Ethernet Connection...8 Lock Relay Connection...9 Wiegand Output Connection...11 Standalone Installation...12 Device Operation...13 ZKBioSecurity Software Installation and Setup starts at Page 16

2 Safety Precautions The following precautions are to keep users safe and prevent any damage. Please read carefully before installation. Do not install the device in a place subject to direct sunlight, humidity, dust or soot. Do not place a magnet near the product. Magnetic objects such as magnets, CRTs, TVs, monitors or speakers may damage the device. Do not place the device next to heating equipment. Be careful not to let liquid like water, drinks or chemicals leak inside the device. Do not let children touch the device without supervision. Do not drop or damage the device. Do not disassemble, repair or alter the device. Do not use the device for any other purpose than specified. Clean the device often to remove dust on it. In cleaning, do not splash water on the device but clean it with a smooth cloth or towel. Contact your supplier in case of a problem.

On Using Face Recognition Device 3 1. Recommended Standing Position For user heights between 1.5m to 1.8m, it is recommended to install the device at 1.15m above ground (may be modified according to user average height). a. Recommended Registration and Verification Position During registration and verification procedures, the position of device should not be changed to prevent deduction in verification preciseness. If it is necessary to move the device, its vertical height should not be changed. b. Factors Affecting the Preciseness of Verification Non-identical registration and verification gestures Non-identical registration and verification height

4 On Using Face Recognition Device Non-identical registration and verification distances from device Non-identical registration and verification distances from device 2. Registration a. During registration, it is required to adjust your upper body to fit your eyes into the green frame on the screen. b. During verification, it is required to show your face in the center of the screen and fit your face into the green frame in the screen.

Device Overview 5 Not all products have fingerprint or card function. ProBio ProFAC ProBio ProFAC Touch screen Door Bell Camera Fingerprint & Card Reader Card Reader Area Area Left side view is common for both the devices USB Slot Reset Button

10 11 12 Fixing Hole 13 14 15 Fixing Hole Fixing Hole Mounting Positioning Sticker (only for your reference) Instruction on using Mounting Positioning Sticker: Before fastening the device, please stick this Mounting Positioning Sticker onto where you want to install the device, and then drill holes and lay cables according to the symbols on the sticker. Wiring Hole Fixing Hole 1.15m recommended height from the ground for facial terminal and 1.4m for finger vein terminal, it can be adjusted according to the staff height 6 Product Dimensions & Installation Product Dimensions ProBio 7.51 in (190.8 mm) 5.08 in (129 mm) 3.35 in (85 mm) 4.05 in (103 mm) 2.4 in (61 mm) Mounting the Device on the Wall 1.15m Put the mounting template sticker onto the wall, and drill holes according to the mounting paper Fix the back plate onto the wall using wall mounting screws. Insert the device into the back plate Use security screws to fasten the device to back plate.

Auxiliary In { Bell{ Sensor { Button { Lock { Alarm { Auxiliary AUX In { BELL- Bell{ BELL+ Sensor SEN { Button { BUT NO1 Lock{ COM1 NC1 AL- Alarm{ AL+ AUX BELL- BELL+ SEN BUT NO1 COM1 NC1 AL- AL+ Power Out { Wiegand In { Red LED Green LED Beep Ethernet Power +12V Out { Wiegand IWD0 In { IWD1 Red LED RLED Green Beep Ethernet { LED { +12V IWD0 IWD1 RLED GLED BEEP GLED BEEP RJ45-1 RJ45-2 RJ45-3 RJ45-6 RJ45-1 RJ45-2 RJ45-3 RJ45-6 WD0 Wiegand Out WD1 RXD Rs232{ TXD 485A RS485{ 485B Power In{ Wiegand Out RS232 { { RS485 { Power In { { +12V WD0 WD1 RXD TXD 485A 485B +12V Power Connection 7 Without UPS 12V DC 12V DC Adaptor With UPS (Optional) 12V DC UPS Recommended Power Supply 12V±10%, at least 500mA (12V /3A is standard). To share the power with other devices, use a power supply with higher current ratings.

Auxiliary AUX In { BELL- Bell{ BELL+ Sensor SEN { Button { BUT NO1 Lock{ COM1 NC1 AL- Alarm{ AL+ Power +12V Out { Wiegand IWD0 In { IWD1 Red LED RLED LED Green Beep Ethernet { GLED BEEP RJ45-1 RJ45-2 RJ45-3 RJ45-6 WD0 Wiegand Out { WD1 RXD Rs232{ TXD 485A RS485{ 485B Power In{ +12V 8 76 5 43 2 1 8 Ethernet Connection LAN Connection Ethernet cable RJ 45 Network Cable Apator ZKBioSecurity DESCRIPTION RJ45-1 RJ45-2 RJ45-3 RJ45-6 WIRE Yellow Green Red Black Note: The device can be connected to PC directly by Ethernet cable.

Auxiliary AUX In { BELL- Bell{ BELL+ Sensor SEN { Button { BUT NO1 Lock{ COM1 NC1 AL- Alarm{ AL+ Power +12V Out { Wiegand IWD0 In { IWD1 Red LED RLED LED Green Beep Ethernet { GLED BEEP RJ45-1 RJ45-2 RJ45-3 RJ45-6 WD0 Wiegand Out { WD1 RXD Rs232{ TXD 485A RS485{ 485B +12V Power In{ Lock Relay Connection 9 Device Not Sharing Power with the Lock 1 COM1 12V DC 12 12V DC Adaptor DESCRIPTION AUX BELL- BELL+ SEN BUT NO1 COM1 NC1 AL- AL+ WIRE Brown Purple Green Yellow Red Blue White Black Gray Black Red Do not use Sensor NC1 + FR107 Diode - Normally Closed Lock Notes: 1. The system supports NO LOCK and NC LOCK. For example the NO LOCK (normally opened at power on) is connected with NO1 and COM1 terminals, and the NC LOCK (normally closed at power on) is connected with NC1 and COM1 terminals. 2. When electrical lock is connected to the Access Control System, you must parallel one FR107 diode (equipped in the package) to prevent the self-inductance EMF from affecting the system. Do not reverse the polarities.

Auxiliary AUX In { BELL- Bell{ BELL+ Sensor SEN { Button { BUT NO1 Lock{ COM1 NC1 AL- Alarm{ AL+ Power +12V Out { Wiegand IWD0 In { IWD1 Red LED RLED LED Green Beep Ethernet { GLED BEEP RJ45-1 RJ45-2 RJ45-3 RJ45-6 WD0 Wiegand Out { WD1 RXD Rs232{ TXD 485A RS485{ 485B Power In{ +12V 10 Lock Relay Connection Device Sharing Power with the Lock 1 12V DC COM1 1 12 7 DESCRIPTION AUX BELL- BELL+ SEN BUT NO1 COM1 NC1 AL- AL+ WIRE Brown Purple Green Orange Yellow Red Blue White Black Gray Black Red Sensor NC1 Do not use + FR107 Diode - Normally Closed Lock

Auxiliary In Bell Sensor Button Lock Alarm Power Out In Ethernet Out?? Wiegand Output Connection 11 DESRIPTION WD0 WD1 RXD TXD 485A 485B WIRE Green White Black Gray Purple Black Blue Yellow WD1 WD0? Do not use???? BEEP???? GLED? WD1??? WD0????????? +12V???

12 Standalone Installation ZKBioSecurity ZKBioSecurity Ethernet ProBio ALARM Sensor No Touch EXIT Lock Exit Button Doorbell Rs485 Fingerprint Reader

Device Operation 13 Date/Time Settings Press icon to enter the Main Menu > System > Date Time to set date and time. Adding User Press icon to enter the Main Menu > User Mgt. > New User to enter the New User adding interface. Settings include entering user ID, user name, choosing user role (Super Admin / Normal User), registering fingerprint / face / badge number / password / user photo, and setting access control role. Ethernet Settings Press icon to enter the Main Menu > Comm. > Ethernet. The parameters below are the system default values. Please adjust them according to the actual network. IP Address: 192.168.1.201 Subnet Mask: 255.255.255.0 Gateway: 0.0.0.0 DNS: 0.0.0.0 TCP COMM. Port: 4370 DHCP: Dynamic Host Configuration Protocol, which dynamically allocate IP addresses for clients via server. If DHCP is enabled, IP cannot be set manually. Display in Status Bar: To set whether to display the network icon on the status bar.

14 Device Operation ADMS Settings Press icon to enter the Main Menu > Comm. > ADMS, to set the parameters which are used for connecting with the ADMS server. When the Webserver is connected successfully, the initial interface will display the logo. Enable Domain Name: When this function is turned on, the domain name mode http://... will be used, such as http://www.xyz.com. xyz denotes the domain name when this mode is on; when this mode is off, enter the IP address format in xyz. Server Address: IP address of the ADMS server. Server Port: Port used by the ADMS server. Enable Proxy Server: Method of enabling proxy. To enable proxy, please set the IP address and port number of the proxy server. Entering proxy IP and server address will be the same. Note: To connect the device to ZKBioSecurity software, Ethernet and ADMS options must be set correctly. Access Control Settings Press icon to enter the Main Menu, press Access Control to enter Access Control setting interface. To gain access, the registered user must meet the following conditions: 1. User s access time must fall within either user s personal time zone or group time zone. 2. User s group must be in the access combo (when there are other groups in the same access combo, verification of members of those groups are also required to unlock the door). Access Control Options: To set parameters of the lock and other related devices. Time Rule Setting: To set a maximum of 50 time rules. Each time rule consists of 10 spaces (7 spaces for one week and 3 holiday spaces), each space consists of 3 time periods.

Device Opreation 15 Holidays: To set dates of holiday and the access control time zone for that holiday. Combined Verification: To set access control combinations. A combination consists of a maximum of 5 access control groups. Anti-Passback Setup: To prevent passing back which causes risks to security. Once this function is enabled, entry and exit records must be matched in order to open door. In Anti-Passback, Out Anti-Passback and In/Out Anti-Passback functions are available. Access Control Combination Settings E.g. : Add an access control combination which requires 2 person s verification from both Access Control Group 1 (set in User Management) and Access Control Group 2. 1. In Combined Verification list, click the desired combination to modify, and enter the interface (as shown in figure 1). 2. Click + or - to set the user access control group no., and then click Confirm to save and return to Combined Verification. Note: A. A single access control combination can consist of a maximum of 5 access control groups (in order to open door, verification of all 5 users is required). B. If the combination is set as shown in figure 3, a user from access control group 2 must obtain verification of 2 users from access control group 1 in order to open door. C. Set all access control group number to zero to reset access control combination. Troubleshooting Q Q : Invalid Time Period is displayed after verification? A A : Contact Administrator to check if the user has the privilege to gain access within that time zone. Q Q : Verification succeeds but the user cannot gain access? A A : Check whether the lock wiring is correct. Q Q : The Tamper Alarm rings? A A : To cancel the triggered alarm mode, carefully check whether the device and back plate are securely connected to each other, and reinstall the device properly if necessary. Q Q : How to cancel alarms? A A : Verify a registerd user.

16 ZKBioSecurity 3.0 It is recommended to install software version 3.0.3.0 or above Installation & Setup Downloading...17 Installation...18 Adding Device...20 Creating a Time Zone...22 Creating an Access Level...23 Enrolling Personnel...24 Wiegand Format...26 Add & Delete Personnel to Access Level...27 Real -Time Monitoring...28 Exporting Reports...29

Downloading 17 1. Go to http://www.zkteco.com/product/zkbiosecurity3.0_421.html 2. Download the latest software and related files as required. 3. Once downloaded, extract the rar file to a new folder. 4. Click on setup to begin installstion.

18 Installation 1. System will check the requirements to install the software. Click Continue if all tests are passed, else check the issues and re-test. 2. Add an open port (Default 8088) or ask a network administrator for an open port. Note: Stanalone device doesn t support https. 3. Click the check box to add firewall exception for this port.

Installation 19 4. Select the mode of database. The default will be PostgreSQL, if you want to select any other database, then select Alternative database. 5. Click Browse and choose or create a folder to store your backup files. 6. Select/Create the required folder. 7. Click OK.

20 Adding Device 1. Click on Access to get below interface of Access Module of the software. 2. Click on Device. 3. Click on Search Device. 4. Click Search to search all the sandalone devices on the network. 5. From the list, click Add to add the required device.

Adding Device 21 6. Enter a unique name. 7. Enter the IP address of current system (PC). 8. Enter the access point of system. 9. Click on this option, after adding device, the system will clear all data in the device (except the event logs). 10. Click OK to finish. The default IP address may conflict with the device IP of other devices. In order to avoid that problem, modify the IP address as shown below: When the device is not in the same network with server, customers should download the tool and search the device as shown below:

22 Creating a Time Zone Click Access Control > Time Zones > Add to access the time zone setting interface. After setting the time zone, click OK to save, and the time zone will appear in the list.

Creating an Access Level 23 1. Click Access 2. Click Access Control 3. Click Access Levels 4. Click New. 5. Enter the details and click OK. 6. You need to add doors to the access levels. 7. Select the required door(s). 8. Move the selected door(s). 9. Click OK to finish adding doors.

24 Enrolling Personnel 1. Click Personnel 2. Click Person 3. Click New to add personnel. A. Personnel ID: It must be a unique 9 characters length with the valid range of 1-79999999. It can be configured based on actual conditions. The Personnel No. contains only numbers by default but may also include letters after setting parameters.

Enrolling Personnel 25 B. Department: Select from the pull-down menu and click OK. If the department was not set previously, you can only select the default [Company Name] department. C. Password: Set personnel password. It only supports 6-digit passwords. If password exceeds the specified length, the system will truncate it automatically. It can t be same with duress or other passwords. D. Card Number: You can add a card number through manual entry or a card issuer. For issuing through issuer, click on the card icon directly. For issuing card manually, you must enter both the card number and the site code, then the software converts the numbers to the card number for access control system verification. E. Access Control: Here you will get all the access levels created by you and by default. Tick the required box. F. Fingerprint: Enroll the Personnel Fingerprint or Duress Fingerprint. Duress Fingerprint is to trigger the alarm and send the signal to the system in case of emergency.

26 Wiegand Format Wiegand Format is the card format that can be identified by Wiegand reader. The software is embedded with 10 Wiegand formats. You may set the Wiegand card format as required. 1. Click Personnel 2. Click Card Management 3. Click Wiegand Format. 4. Taking Wiegnad Format34 as an example. Click to edit. This software supports two modes for adding Wiegand Format, if mode 1 does not meet your setting requirement, switch to mode 2. p indicates Parity Position, s indicates Site Code, c indicates Cardholder ID, f indicates Facility Code, m indicates Manufactory Code, e indicates Even Parity, O indicates Odd Parity, b indicates both odd check and even check, x indicates parity bits no check.

Add & Delete Personnel to Access Level 27 1. Click Access 2. Access Control 3. Set Access by Person 4. Click on the required employee 5. Click Add to Levels. 6. Select Level(s). 7. Click to move the selected level(s) to the right, and then click OK to complete adding. The added level(s) will appear in the list on to the right side.

28 Real -Time Monitoring 1. Click Access 2. Click Access Device 3. Click Real-Time Monitoring Real-time monitor the status and real-time events of standalone in the system, including normal events and abnormal events (including alarm events) device transactions. You can also filter by Area, device name, Serial number to check a specific device transactions or all at once. Hover over a door icon to open pop up menu as shown below and click Remote Closing, Remote Opening, or Cancel Alarm and more.

Exporting Reports 29 Access Module: 1. Click Access 2. Click Reports 3. Filter the data (time, Personnel ID, Device Name and more) if required and click on search 4. Click All transactions or as required. 5. Click on Export to get the list. 6. Click OK. Personnel Module: 1. Click Personnel 2. Click Person 3. Filter the data (Department, Personnel ID, and more) if required and click on search 4. Click on Export to get the list.

30 6 Kingsbridge Road, Suite 8 Fairfield, NJ 07004 T: +1 862 505 2101 sales@zkaccess.com www.zkaccess.com ZKAccess-division of ZKTeco