AMU1-CHD+MK2 AUDIO MONITORING UNIT

Similar documents
TM1 MK2 and TM1+ MK2 Installation Manual (SN on)

MAINS DISTRIBUTION UNIT MDU14-CO

Marshall Electronics. AR-AM4-BG Analog Audio Monitor. Operating Instructions

Tallyman Controller Quick Configuration Manual

The TSL Tally and UMD Configuring Program. Power Supply PSU-22 this section is intended to be read in conjunction with the Introduction

Marshall Electronics. Operating Instructions. Warranty. AR-AM4 Analog Audio Monitor

Marshall Electronics. AR-AM1 Analog Audio Monitor. Operating Instructions

Marshall Electronics. Operating Instructions. Warranty. AR-AM1 Analog Audio Monitor

MASELEC MTC-6 master transfer and monitor system

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

User Operating Manual

T L Audio INDIGO SERIES. User Manual PA-2001 VALVE PRE-AMPLIFIER. Tony Larking Professional Sales Limited, Letchworth, England.

User Guide PRNT

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

GXD8 Operational Manual

AUDIO D-Type Pin-outs TALKBOX INSTALLER 12 1U RACK BOX BCD 25/09/07. Broadcast Audio Custom Manufacture Design and Consultancy

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

BS 15 BASIC SERIES USER MANUAL FOR THE SINGLE CHANNEL BELTPACK CONTENTS

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN

AMS16 2AM & AMS16 2AEM 16 CHANNEL AUDIO MONITORING SYSTEM

MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER

TELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN

Reference Monitors. June catalogue. Manufacturers of audio & video products for radio & TV broadcasters

HRS-1S. Half Rack Analog Stereo Audio Speaker Monitor. User Guide. Part Number , Revision E

Di2 Mk3 Active Direct Inject Box

TOA ELECTRIC CO., LTD.

INSTRUCTION MANUAL CM-60. Monitor. Ultra Stereo Labs, Inc. 181 Bonetti Drive San Luis Obispo, CA Telephone

Berkeley Audio Design Alpha DAC Reference Series 2 User Guide for Software Rev 2.00

User Guide for Software Rev 3.00

DM200 DIGITAL AUDIO MONITOR OPERATION AND MAINTENANCE MANUAL

IST ULTRASTAB Power Supply for high precision transducers

PRE116/126. User Manual.

Data Sheet (preliminary) TouchMonitor TM3-3G

Instruction Manual. G.R.A.S. 12AA 2-Channel Power Module with gain, filters and SysCheck generator. LI April 2015

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Solid State Logic S O U N D V I S I O N

AMP20. User Manual.

HA1M. User Guide. Two Input Headphone Amplifier. Two mono inputs to one stereo headphone amp

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

FPA-1 Facility Port Adapter Installation Guide

Owner s manual. SDAI 2175 Semi Digital Amplifier Integrated

MG12XU Overview Features Technical Data Sheet

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

Specifications XPA 2002, XPA 2003, XPA 2004 Series

MODEL 805 USER MANUAL

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG03

GM/2 Dual Gain Manager Operation Manual

HP4 headphone amplifier. user manual

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG06

Installation Guide. Stereo / Mono Audio Power Amplifier - 60 Watts AT-GAIN-60. Package Contents

TZW803+ 8x1 VGA/XGA & AUDIO SWITCHER. ELPRO Video Labs s.r.l. St.da della Pronda, 45/B Torino ITALY Tel Fax

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

INTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module

CDI DriveCore Series. Features \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

AMS x1 Video + Audio Passive Switcher. User Manual. I.R.T. Communications Pty Ltd Page 1 of 10 Revision 03

Network audio encoder / decoder with I/O for professional and broadcast applications

Series Watt DC Power Supplies

Product Spec Sheet 2 Channel Audio Recorder HS-20

APT20. User Manual.

User Guide FFFA

Cisco D9034-S Encoder

DALLIS Product Information

OYSTER 2-6 LOUDSPEAKER MANAGEMENT SYSTEM USER MANUAL. Software version

AMP1-DA/106. 1RU Audio Speaker Monitor. User Guide. Part Number , Revision B

Audio Interface Quick start guide

BU400,BU400B,UB400B, UB400B, & BI400

Telex. User Instructions. Model US2000A Intercom User Station Audiocom Intercom Systems US2000A. Listen Listen. Talk Talk. Volume. Mic Kill.

BS 217 DUAL CHANNEL MASTER STATION USER MANUAL

*TD * Loudspeaker Signal Processing Products User Manual SC28. Two-Input, Eight-Output System Controller for QSC Loudspeakers

SL Interpreter Compact

Prisma II Platform. Optoelectronics

IC-I AND IC-I F GENERAL DESCRIPTION SPECIFICATIONS. Output Impedance: Phones: 60 ohms (Unit is designed for use with ohm phones.

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console MG10. MG10 is a versatile mixer suitable for a wide range of users and applications.

The Nagra VI Six channel digital audio recorder Digital Location Recorder

MXA2080. Stereo Power Amplifier. Owner s Manual

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual

DLCP. Digital Loudspeaker Cross-over Platform Datasheet

Cisco Prisma II Platform

TOA ELECTRIC CO., LTD.

1 master and 8 independent stereo subgroup Flexible architecture including a modular control surface, outputs

UNBALANCED TO BALANCED CONVERTERS

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

Description of the amplifier s functions.

OWNER S MANUAL CD-2 V 1.3

Datasheet IQ Modular Enclosures Flexible and Reliable Video and Audio Backbone

New Products. January A 1U rackmount unit for mixing & monitoring up to 24 x AoIP streams into headphones, speaker and analogue outputs.

576 E USA

COPYRIGHT 2010 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

PS 680 SIX CHANNEL POWER SUPPLY WITH AUX MATRIX USER MANUAL

TELIKOU Intercom System

OVERVIEW SYSTEM REQUIREMENTS

Installation & Operation Guide

IMPORTANT SAFETY INSTRUCTIONS

Transcription:

AMU1-CHD+MK2 AUDIO MONITORING UNIT Handbook TSL Products Units 1-2, First Avenue, Globe Park, Marlow, Bucks, SL7 1YA Telephone +44 (0)1628 564610

This Page is Blank

SAFETY Installation. Unless otherwise stated TSL equipment may be installed at any angle or position within an operating temperature range of 5-30 C. All TSL equipment conforms to the EC Low Voltage Directive: EC Low Voltage Directive (73/23/EEC)(OJ L76 26.3.73)(LVD). Amendment: (93/68/EEC) (OJ L220 30.8.93). In all cases the chassis of the equipment must be earthed on installation. The external power supply provided with this product may be one of two types: 1. A Class 2 double insulated type with a figure of eight mains input connector. 2. A Class or Level 3 type with an IEC mains input connector. This type offers a functional earth and NOT A SAFETY EARTH via the earth pin of the IEC mains input connector to the outer of the co axial power connector or the pin nearest the pip on the Lemo style connector. All metal panels are bonded together. Check that the voltage selector setting (if fitted) and the fuse rating is correct for the local mains supply. Due consideration for cooling requirements must be given when mounting the equipment. It is recommended that a 1RU of rack space, or a vent panel, should be left above and below the unit. This unit requires rear support. WARRANTY, MAINTENANCE AND REPAIR All TSL equipment is guaranteed for one year from the date of delivery to the customer s premises. If the equipment is to be stored for a significant period, please contact TSL concerning a possible extended warranty period. Failure during warranty If any TSL product should fail or become faulty within the warranty period, first please check the PSU fuses. All maintenance work must be carried out by trained and competent personnel. If equipment has to be returned to TSL for repair or re-alignment, please observe the following overleaf:

TSL Returns Procedure Please telephone +44 (0)1628 564610 and ask for Support who will provide a Returns Number. This will enable us to track the unit effectively and will provide some information prior to the unit arriving. Please do NOT return faulty equipment without first obtaining a returns number as this is likely to result in a delay in the repair of the equipment. For each item, this unique Returns Number must be included with the Fault Report sent with the unit. A contact name and telephone number are also required with the Fault Report sent with the unit. Fault report details required. Company: Name: Address: Contact Name: Telephone No: Returns Number: Symptoms of the fault (to include switch setting positions, input signals etc): Packing Please ensure that the unit is well packed as all mechanical damage is chargeable. TSL recommends that you insure your equipment for transit damage. The original packaging, when available, should always be used when returning equipment.. If returned equipment is received in a damaged condition, the damage should be reported both to TSL and the carrier immediately.

This Page is Blank

Contents 1.0 Introduction 2.0 Front Panel Controls and Indicators 2.1 Input and Meter Selection Switches 2.2 Monitoring select Switch 3.0 Pin-out Details 3.1 Analogue XLR Connectors 3.2 AES XLR connectors 3.3 Analogue Output connector D25 Socket Pin out 3.4 AES Input/Output connector 3.5 DIP switch configuration functions 4.0 Notes 5.0 General Notes 6.0 Specifications 7.0 Front and rear view 8.0 Block Schematic

1.0 Introduction The AMU1-CHD+ mk2 is a 1RU x 320mm deep Audio Monitoring Unit with two 26 segment bargraphs for audio level measurement. The following features are standard: Two switch selectable stereo analogue inputs Four AES /EBU inputs Two HD/SDV auto sensing inputs Out-of-phase error indication EBU Digital and PPM metering scales Encoded PAL/NTSC composite or SDI output (Switch selectable) Re-clocked serial output of the selected input Integral loudspeaker system 40 Watt total amplifier power with 12VDC input Headphone outputs with LS muting Two 12V DC inputs Stereo /multi channel line outputs Two decoded AES outputs Variable line output 2.0 Front Panel Controls and Indicators 2.1 Input and Meter Selection Switches Digital Source Select Channel Select Meters Phase Selects AES 1-2 and 3-4 (in conjunction with the channel switch) and SDI 1 & 2 Groups 1-4 Selects AES1,2,3 and 4 and pairs 1 (D1) and 2 (D2) from both the SDV inputs. Analogue 1 and 2 are also selected in position Anl 1 and Anl 2. Left Channel is fed to the left bargraph and Right Channel is fed to the right bargraph. Momentary phase reverse between A1 and A2 pairs. A non latching push switch with Red/Green LED indicates phase. Push to reverse. Volume Control Allows the audio level to be varied.

2.2 Monitoring select Switch This switch allow stereo, Left, Right and Mono to be monitored from the internal loudspeakers and line outputs. N.B. Position D is spare. 3.0 Pin-out Details 3.1 Analogue XLR Connectors C PIN FUNCTION ANALOG 1 1 GND ANALOG 1 2 1 IN+ ANALOG 1 3 1 IN- ANALOG 2 1 GND ANALOG 2 2 2 IN+ ANALOG 2 3 2 IN- 3.2 AES XLR Connectors C PIN FUNCTION AES1 1 GND AES 1 2 1 IN+ AES 1 3 1 IN- AES 2 1 GND AES 2 2 2 IN+ AES 2 3 2 IN-

3.3 Analogue Output Connector D25 Socket Pinout on unit, Plug (shown) on mating cable. D 25 SOCKET ON AMU AUDIO OUTPUTS PIN NO FUNCTION 1 14 2 15 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 A2+ (FR) 23 A2- (FR) 11 Ground 24 A1+ (FL) 12 A1- (FL) 25 Ground 13 N/C Note; this is a generic pin out, the outputs available are indicated in the table. (N.B. These are analogue outputs of digital inputs)

3.4 AES Input/Output Connector D25 Socket Pinout, Plug (shown) on mating cable. D 25 SOCKET ON AMU AES INPUTS/OUTPUTS PIN NO FUNCTION 1 Ch1&2 Input 1+ 14 Ch1&2 Input 1-2 Ch3&4 Input 2+ 15 Ch3&4 Input 2-3 Ch5&6 Input 3+ 16 Ch5&6 Input 3-4 Ch7&8 Input 4+ 17 Ch7&8 Input 4-5 Ch1&2 Output 1+ 18 Ch1&2 Output 1-6 Ch3&4 Output 2+ 19 Ch3&4 Output 2-7 N/C 20 N/C 8 N/C 21 N/C 9 N/C 22 Ground 10 Ground 23 Ground 11 N/C 24 Ground 12 Ground 25 Ground 13 Ground To use an unbalanced input pin 17 must be grounded. D-25 pins 10, 12, 17, 13, 22, 23, 24 and 25 are available for this purpose.

3.5 Configuration Switch Functions (subject to change, Y05 s/w) SWITCH SECTION FUNCTION 1 PPM Up/ EBU Digital Down 2 Peak Hold OFF-Up 3 Internal speaker Mute- Up 4 Calibration Level see below 5 Calibration Level see below 6 Calibration Level see below 7 Not used 8 Composite out-up/sdi \Down The level configuration switches on the HDC2 board operates in a 2 s complement manner the relationship between the dbfs level setting in the digital domain and the dbm level setting in the analogue domain. The zero position with all switches in the down position is designed to give 0dBm out for a level of -18dBfs in digital space. See below for configuration SW4 SW5 SW6 FUNCTION UP UP DN -24dBFS DN UP DN -22dBFS UP DN DN -20dBFS DN DN DN -18dBFS UP UP UP -15dBFS DN UP UP TBD UP DN UP TBD DN DN UP TBD (See Notes 4.0)

4.0 Notes There are no user adjustable assemblies/components within this unit. This unit requires rear support when rack mounted. In order to affect status changes of the unit using the rear DIP switch, the unit will require re powering before the changes take effect. Output analogue levels are adjustable over the following range: 0dBm = 0.775V into 600Ω i.e. 1mW power dissipation. 0dBu = 0.775V RMS = PPM 4. Nominally, -18 db ref 0FS = European line up : American line: 0dBu output. -18 dbu -20 dbu 5.0 General Notes Please note that some American equipment has the function of the XLR pins 2 & 3 reversed. TSL product is wired to the European standard The screw locks on the D25 connectors use UNC 4-40 standard threads.

6.0 AMU1- CHD+mk2 Technical Specifications Power Supply Supply Voltage Power Consumption 12V DC 50 watts. Physical Dimensions Height 44mm (1RU) Width 483mm (19 ) Depth 320mm Weight 4500gm Analogue Inputs 1-2 Connector Type Signal Frequency Response XLR Female 3 pin. Pin 1 Gnd, Pin 2 hot, Pin 3 cold. Balanced line level audio. 30Hz to 25kHz >20kΩ Inputs AES 1, 2, 3 & 4 Connector Type Standard Input, HD/SDV 1 &2 Connector Type Standard Line Output. Connector Output Levels Fixed Line O/P Headphone Output. Connector Output Levels XLR Female 3 pin. Pin 1 Gnd, Pin 2 hot, Pin 3 cold. AES3 (1994) at 48kHz, 44.1kHz or 32kHz 110 ohm (balanced.) BNC. 4:2:2 component with embedded 48Khz audio. (SMPTE 259M, 292M and 424M) 75ohm XLR 3 pin Male 50Ω Through level control with 0dB gain. Available on D25 (If selected on front panel) Stereo Jack socket type A 600Ω Through level control with 0dB gain. De embedded output Connector 25 way D type 110 Ohm Output Groups 1, 2, 3 and 4 Video Output Connector Output BNC 75 Ohm Composite video or SDI (selectable)

Re-clocked Output Connector Output BNC 75 Ohm Re-clocked serial output of the SELECTED input HD/SDV AES Output Connector Output AES I/O, 25 way D type (See section 3.4 for details) 110 Ohm Selected SDI group. HD Standards Supported 1080i/50 1080i/59.94 1080i/60 720p/50 720p/59.94 720p/60 Performance Response 70Hz to 20KHz Electrical Distortion Better than 0.1% Hum and noise SPL Amplifier Output Digital Sample Rate Better than -70dB >98dB at 0.6 m 40 watts total power output 32 to 48KHz auto select

7.0 Front and rear view

8.0 Block Schematic