SCv360 Expansion Enclosure

Similar documents
Dell SC460 Expansion Enclosure Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell MD1280 Storage Enclosure Getting Started Guide

Dell EMC Storage MD1280 Enclosure Owner's Manual

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell PowerEdge T420 Getting Started Guide

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell PowerEdge R720 and R720xd Getting Started Guide

Dell PowerEdge T620 Getting Started Guide

SCv3000 and SCv3020 Storage System. Owner s Manual

Dell Storage Center. Owner's Manual. SC180 Expansion Enclosure. Regulatory Model: E11J Regulatory Type: E11J001

DELL EMC SC SERIES EXPANSION ENCLOSURES

Customer Replacement Procedure

Customer Upgrade Procedure

Dell PowerEdge T620 Getting Started Guide

Dell EMC ME4 Series JBOD 5U84 Enclosure

Dell SC5020 and SC5020F Storage System Owner s Manual

TRC-190 User s Manual

TRC-190 User s Manual

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

SGI InfiniteStorage 120

EXN4000 Storage Expansion Unit Installation and Setup Instructions

Dell Networking S4100-ON Series. Set-Up Guide

Installing the IPS 4345 and IPS 4360

1 Getting Started Installing & Configuring

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

XCM8800 PSU Cover. Installation Guide. 350 East Plumeria Drive San Jose, CA USA. May v1.0

Dell OptiPlex All-in-One. Stand Installation Guide

S5048F-ON. Set-up Guide

Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide

DNS-2608 Enterprise JBOD Enclosure User Manual

N3150 Installation and Setup Instructions

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

IBM. Rack Installation Instructions

SuperLoader 3 Quick Start Guide

Rack Installation Instructions

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Rack Installation Instructions

Installing the Cisco SFS 3504 Server Switch

Rocsecure NE52 NAS System

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Dell Latitude E5410/E5510

System Storage EXP3000 Rack Installation Instructions

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

JanusRAID SA-6692J Hardware User Manual

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Installation Job Aid for Avaya Virtual Services Platform 8400

N3240 Installation and Setup Instructions

Replacing an Advanced Power and Cooling (APC) Unit

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Dell EMC Data Domain DD9500 and DD9800 Systems

Dell Storage MD1400 and MD1420 Enclosures Getting Started Guide

Dell Networking C9010 Getting Started Guide

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide

AppleCD 300e Plus/600e

N3220 Installation and Setup Instructions

Dell EMC PowerVault MD3460 Storage Arrays

2U STORAGE ENCLOSURE QUICK INSTALL GUIDE FS4100, FS4500, SC4100, AND FC4100

2U, 4U, and 7U Systems

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

Removing Components from the MX960 Chassis Before Installing It Without a Lift

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Dell Inspiron N5110 Service Manual

16Hi HARDWARE INSTALLATION GUIDE

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

G5 PDU Installation Guide

E-Series Site Preparation Guide

Dell XPS 14z Owner s Manual

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method

Customer Replacement Procedure

Power Enclosure Components

Dell Storage Center. Owner's Manual. SC9000 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

User s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!

HP EVA4400 M6412 drive enclosure

S4112-ON Series. Setup Guide

VEP4600. Setup Guide

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Rack Installation Guide

HYPER-UNIFIED STORAGE. Nexsan Unity

Flat Panel Static Wall Mount MSP-SS (GSM-210)

XTM 1050 Replacement Parts Installation

Installing the Cisco MDS 9020 Fabric Switch

Installation and Maintenance

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

Customer Replacement Procedure

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Dell Precision Workstation T7500/T7500n Setup and Features Information

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Transcription:

SCv360 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. 2017 2018 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. 2018-04 Rev. A00

Setting Up the Expansion Enclosure Consider the following best practices when setting up an SCv360 expansion enclosure: An SCv360 expansion enclosure is shipped with two SAS cables. Two more SAS cables are needed to connect an SCv360 expansion enclosure to a storage system in a highavailability environment. The SAS cables can be ordered in lengths of three, four, or five meters. Before connecting any cables between the expansion enclosure and storage system, physically label each port and connector. Always follow proper power-up and power-down procedures when cycling power across the network. Verify that critical network components are on separate power circuits. Topics: Other Information You May Need Installation and Configuration NOM Information (Mexico Only) Technical Specifications Other Information You May Need To install the expansion enclosure, you may need the following additional information: Dell SCv360 Expansion Enclosure Owner s Manual Provides information about an SCv360 expansion enclosure, such as hardware features, replacing hardware components, and technical specifications. Dell SCv3000 and SCv3020 Storage System Deployment Guide Provides information about an SCv3000 series storage system, such as cabling the hardware components and configuring the storage system using Storage Manager. Dell Storage Manager Administrator s Guide Provides instructions for using the Data Collector Manager and the Dell Storage Manager Client. Setting Up the Expansion Enclosure 3

Installation and Configuration Before you begin the installation, make sure that the site where you plan to install the expansion enclosure has standard power from an independent source or a rack power distribution unit (PDU) with a UPS. Safety Precautions Always follow these safety precautions to avoid injury and damage to Storage Center equipment. If equipment described in this guide is used in a manner not specified by Dell, the protection provided by the equipment could be impaired. For your safety and protection, observe the rules described in the following sections. NOTE: See the safety and regulatory information that shipped with each Storage Center component. Warranty information is included as a separate document. Installation Safety Precautions Follow these safety precautions when installing an SCv360 expansion enclosure: Caution Equipment exceeds 90 kg (200 lb). Use appropriate lifting methods when installing an SCv360 expansion enclosure. You can install the expansion enclosure chassis without using a mechanical lift if you remove the drives, cooling fans, power supply units (PSUs), and enclosure management modules (EMMs) from the chassis before installing it. You must use a mechanical lift to install the expansion enclosure chassis if you do not remove the drives, cooling fans, PSUs, and EMMs from the chassis. Dell recommends that only individuals with rack-mounting experience install an SCv360 expansion enclosure in a rack. When installing multiple expansion enclosures in a rack, fill the rack from the bottom up and empty the rack from the top down. 4 Setting Up the Expansion Enclosure

The rack construction must support the total weight of the installed expansion enclosures. The design should incorporate stabilizing features suitable to prevent the rack from tipping or being pushed over during installation or in normal use. To prevent the rack from tipping, slide only one expansion enclosure out of the rack at a time. Make sure that the expansion enclosure is always fully grounded to prevent damage from electrostatic discharge. When handling the expansion enclosure components, use an electrostatic wrist guard or a similar form of protection. Setting Up the Expansion Enclosure 5

Unpacking Storage Center Equipment Unpack the expansion enclosure and identify the items in your shipment. Figure 1. Expansion Enclosure Components 1 Expansion enclosure 2 Rack rails (2) 3 Mini-SAS HD cables (2) 4 Power cables (4) 5 Front bezel (Optional) 6 Documentation 6 Setting Up the Expansion Enclosure

Determine the Mounting Location Determine where to mount the SCv360 expansion enclosure in the rack. 1 Identify a location in the rack with 4U of space for the expansion enclosure. WARNING: If you plan to install the expansion enclosure above the lower 20U of a rack, use a mechanical lift to avoid injury. 2 If you plan to install the 1U cable management tray below the expansion enclosure, identify a location in the rack with 5U of space for the expansion enclosure and cable management tray. Figure 2. Mounting Location from Front and Back of Rack 1 Location for the clip nuts to secure the top cover 3 Location for the expansion enclosure rack rails 2 Location for the clip nuts to secure the expansion enclosure 4 Location for the 1U cable management tray rails SCv360 Expansion Enclosure Hardware Mounting Kit The SCv360 expansion enclosure ships with the following hardware mounting kits: Setting Up the Expansion Enclosure 7

Table 1. Standard Rail Kit Part Part Number Description 106-002-452 106-002-453 M5-0.8 x 10 mm Phillips pan-head SEMS screw (Quantity: 2) Used to secure the expansion enclosure rails to the front of the rack M5-0.8 x 16 mm Phillips pan-head SEMS screw (Quantity: 2) Used to secure the expansion enclosure rails to the back of the rack 106-569-307 M5-0.8 clip nut (Quantity: 6) Used to secure the expansion enclosure chassis and top cover to a rack without threaded holes Table 2. Universal Rail Kit Part Part Number Description 036-028-016 3.8 mm alignment pin (Quantity: 8) Replacement alignment pin used to mount rails in racks that have M5, #10-32, or #12-24 threaded holes 036-028-017 4.8 mm alignment pin (Quantity: 8) Replacement alignment pin used to mount rails in racks that have M6 threaded holes 036-028-018 M4-0.7 x 10 mm flathead screw (Quantity: 4) Used to secure expansion enclosure rails to a rack with threaded holes 8 Setting Up the Expansion Enclosure

Table 3. Expansion Enclosure Chassis Handle Kit Part Part Number Description 036-034-003 Expansion enclosure chassis handle (Quantity: 4) Used to lift the expansion enclosure chassis onto a mechanical lift and mount it in a rack Table 4. Top Cover and Expansion Enclosure Chassis Kit Part Part Number Description 036-032-010 036-032-011 036-032-009 036-032-012 M5-0.8 x 12 mm truss head Phillips screw with nylon patch (Quantity: 2) Used to secure the top cover to a standard Dell rack or a third-party rack with non-threaded holes M6-1.0 x 12 mm truss head Phillips screw with nylon patch (Quantity: 6) Used to secure the expansion enclosure chassis to a nonstandard rack with M6 threaded holes #10-32 x 1/2 in. truss head Phillips screw with nylon patch (Quantity: 6) Used to secure the expansion enclosure chassis to a nonstandard rack with #10-32 threaded holes #12-24 x 1/2 in. truss head Phillips screw with nylon patch (Quantity: 6) Used to secure the expansion enclosure chassis to a nonstandard rack with #12-24 threaded holes Table 5. 1U Management Tray Rail Kit Part Part Number Description 036-034-012 #8-32 x 3/4 in. Phillips screw (Quantity: 5) Setting Up the Expansion Enclosure 9

Part Part Number Description Used to secure the tray rails to a rack, regardless of the rack type 036-034-003 Square hole alignment pin (Quantity: 9) Replacement alignment pin used to mount tray rails in racks that have 0.375 in. square holes 036-034-004 Threaded hole alignment pin (Quantity: 9) Replacement alignment pin used to mount tray rails in racks that have threaded holes Mount the Cable Management Tray If you plan to use the 1U cable management tray, mount the tray before mounting the SCv360 expansion enclosure. Prerequisite Required materials: Screwdriver (034-000-193) Four 8-32 x 0.75 in. knurled head Phillips screws (036-034-012) Left 1U cable management tray rail (042-034-012) Right 1U cable management tray rail (042-034-008) 1U cable management tray (042-033-060) Steps 1 Adjust the length of the 1U cable management tray rails (042-034-012 and 042-034-008) to fit the rack. 2 Align the rails so that the UP arrow is pointed in the correct direction and the side of the rail labeled FRONT is at the front of the rack. 3 Insert the alignment pins of left and right rails into the mounting holes at the front and back of the rack. 4 Secure the rails by installing 8-32 x 0.75 in. screws (036-034-012) into the holes at the front and back of the rails. 10 Setting Up the Expansion Enclosure

Figure 3. Secure Rails to Rack 5 Align the 1U cable management tray (042-033-060) so that the UP arrow is pointed in the correct direction and the side of the tray labeled FRONT is to the front of the rack. Setting Up the Expansion Enclosure 11

Figure 4. Align the Cable Management Tray 6 Slide the 1U cable management tray into the rails until it locks into place. Mount the Expansion Enclosure Install the rails in the rack, and mount the SCv360 expansion enclosure on the rails. Prerequisite Required materials: Screwdriver (034-000-193) Six clip nuts (106-569-307) Two M5 x 10 mm Phillips pan-head screws (106-002-452) Two M5 x 16 mm Phillips pan-head screws (106-002-453) Steps 1 Adjust the length of the expansion enclosure rack rails to fit the rack. 2 Attach the right rail to the back post of the rack. a b c Align the right rail with the lower two U spaces of the 4U mounting location. With the release latch on the outer part of the rack post, place the catch mechanism over the post. Push the rail back to secure the rail to the rack post. An audible click indicates that the rail is secure in the post. 12 Setting Up the Expansion Enclosure

d Make sure the post/catch mechanism is secure and attached to the rack post. Figure 5. Attach Rail to the Back of the Rack 3 Attach the right rail to the front post of the rack. a Align the right rail with the lower two U spaces of the 4U mounting location. b Pull the rail forward, with the alignment pins in the middle holes of the bottom two U spaces of the 4U mounting location. An audible click indicates that the rail is secure in the post. Figure 6. Attach Rail to the Front of the Rack 4 Secure the rail by installing an M5 x 10 mm screw (106-002-452) in the larger of the two holes at the front of the rail. Setting Up the Expansion Enclosure 13

5 Secure the rail by installing an M5 x 16 mm screw (106-002-453) in the larger of the two holes at the back of the rail. 6 Repeat steps 2 through 5 to install the left rail. 7 Mount the expansion enclosure chassis on the rails. a If a mechanical lift is available, use the four handles that shipped with the expansion enclosure to lift the expansion enclosure chassis onto a mechanical lift. b If a mechanical lift is not available, remove the drives, cooling fans, power supply units (PSUs), and enclosure management modules (EMMs) from the expansion enclosure chassis and use the four handles to lift the chassis to the mounting location. c From the front of the rack, extend the rack rails approximately 5 to 8 cm (2 to 3 in.) and align the expansion enclosure chassis rails with the rack rails. Figure 7. Extend the Rack Rails d Slide the rack rails over the expansion enclosure chassis rails. 14 Setting Up the Expansion Enclosure

e f Remove the four handles from the sides of the expansion enclosure chassis. Slide the expansion enclosure chassis into the rack. Figure 8. Mount the Expansion Enclosure into the Rack 8 If the drives, fans, PSUs, and EMMs were removed from the expansion enclosure chassis, reinstall these components in the chassis. 9 Secure the expansion enclosure chassis and top cover. a b c d e Install the six clip nuts (106-569-307) into the rack holes that align with the shoulder screws on the front of the expansion enclosure chassis. Use the orange enclosure latch handles to push the expansion enclosure chassis completely into the rack. Make sure that the self-locking latches are pushed in and fully engaged to prevent the expansion enclosure chassis from sliding out of the rack. Secure the expansion enclosure chassis to the rack using the orange shoulder screws. If the top cover is secured by two small shipping screws, remove the screws. Secure the top cover of the expansion enclosure chassis to the rack using the shoulder screws. Setting Up the Expansion Enclosure 15

Install the Front Bezel If a front bezel is shipped with the SCv360 expansion enclosure, install the bezel on the front of the expansion enclosure. 1 Align the bezel with the front of the expansion enclosure. 2 Press the two latches on front of bezel. Figure 9. Install the Bezel 3 Push the bezel into place until it attaches to the expansion enclosure. 4 Release the latches on the front on the bezel. 5 If the bezel has key lock, lock the bezel with the key. 16 Setting Up the Expansion Enclosure

NOM Information (Mexico Only) The following information is provided on the device described in this document in compliance with the requirements of the official Mexican standards (NOM): Importer Model number Supply voltage Input frequency Input current Dell México, S.A. de C.V. Javier Barros Sierra, No. 540, Piso 10, Col. Lomas de Santa Fe C.P. 01219, Ciudad de México CYAE 200 240 VAC 50/60 Hz 4.5 A x2 (N+1) Technical Specifications The technical specifications of the SCv360 expansion enclosure are displayed in the following tables. Drives SAS hard drives Dell Enterprise Plus Value drives Up to 60 hot-swappable 7.2K RPM 12 Gbps 3.5 SAS hard drives Connectivity Configurations SCv3000 and SCv3020 storage systems support up to three SCv360 expansion enclosures Enclosure Management Modules (EMMs) EMMs SAS connectors Two hot-swappable EMMs with four 12 Gb SAS ports per EMM. The expansion enclosure supports Mini-SAS HD cables in lengths of 3 m, 4 m, and 5 m. SAS connectors are SFF-8644 compliant Setting Up the Expansion Enclosure 17

Power Supplies Wattage 1600 W per power supply AC Power Input voltage Input frequency Input current 200 240 VAC 50/60 Hz 4.5 A x2 (N+1) Physical Height (4U chassis) Height (4U chassis plus 1U cable management tray) Width (including rails) Depth (chassis only) Maximum depth (fully configured) Weight (maximum configuration) 17.5 cm (6.89 in.) 22.23 cm (8.75 in.) 44.45 cm (17.50 in.) 87.63 cm (34.5 in.) 92.46 cm (36.4 in.) 102.05 kg (225.0 lb) Environmental Temperature Operating Storage 5 to 40 C (41 to 104 F) with a maximum temperature gradation of 10 C per hour -40 to 65 C (-40 to 149 F) with a maximum temperature gradation of 25 C per hour Relative humidity Operating Storage 20% to 80% (noncondensing) 10% to 90% (noncondensing) Altitude Operating -16 to 2300 m (-50 to 7500 ft) 18 Setting Up the Expansion Enclosure

Environmental Storage -16 to 10,600 m (-50 to 35,000 ft) Setting Up the Expansion Enclosure 19