User Guide. Westermo Teleindustri AB BRD-355. Industrial ADSL/VDSL Router.

Similar documents
User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire.

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

User Guide Westermo Teleindustri AB SDW-500. Industrial Ethernet 5-port Switch.

User Guide. Westermo Teleindustri AB RedFox. Ethernet switch and router approved for railway usage.

User Guide. Westermo Teleindustri AB DDW-220 WOLVERINE SERIES DDW-220. Industrial Ethernet SHDSL extender.

DDW-002-B1. EN Ethernet Broadband Bridge. User Guide Westermo Teleindustri AB. 10/100 BASE-TX LINK DC1 X1 X1 DC2

User Guide. Westermo Teleindustri AB DDW-120. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB RV-07B. 19 rack system PS-20 Power card.

User Guide. Westermo Teleindustri AB 2004 REV.A SDW Industrial Ethernet 5-port Switch.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

User Guide. Westermo Teleindustri AB Lynx L110 / L210. WeOS. Industrial Ethernet 10-port Switch.

User Guide. Westermo Teleindustri AB Lynx DSS L105-S1/L205-S1. WeOS. Industrial Ethernet 5-port Device Server Switch.

User Guide. Westermo Teleindustri AB DDW-226 WOLVERINE SERIES. WeOS. Industrial Ethernet SHDSL extender.

User Guide. Westermo Teleindustri AB Lynx DSS L106-S2/L206-S2. WeOS. Industrial Ethernet 6-port Device Server Switch.

AD-01 M-BUS Adapter. Industrial adapter, M-bus, Repeater, Converter and zone controller.

MRD-315, MRD-355 & MRD-455

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

MRD-405. Industrial M2M/4G Gateway/Router GSM / GPRS / EDGE / HSDPA / HSUPA / HSPA/ 4G LTE. User Guide Westermo Teleindustri AB

User Guide Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB DDW-100. Industrial Ethernet SHDSL Extender.

User Guide. Westermo Teleindustri AB Lynx DSS L108 / L208-F2G-S2. WeOS. Industrial Ethernet 8-port Device Server Switch.

Viper-12A. 12 port Ethernet M12 switch. User Guide Westermo Teleindustri AB. ON USB X2 X3 RSTP FRNT CON V ON USB

Legacy Serial. Legacy Serial Redundant Ring Ethernet Extender DDW-222. High Speed Ethernet extension over copper. Configuration and diagnostics

MRD-350. Industrial Mobile Broadband Router GSM / GPRS / EDGE / 3G / HSDPA / HSUPA / HSPA. User Guide

Viper port Ethernet M12 switch. User Guide Westermo Teleindustri AB. X1 X5 X9 X6 X10 X7 X11 SRV 1 X2 X8 X12 DC X4

Viper 20A Series. 20 port Ethernet M12 switches. User Guide REV. C. Westermo Teleindustri AB. X9 X15 X16 X17 X10 X11

Industrial Routing Switch

Ethernet Extender with serial support DDW-226

Wolverine DDW DDW Industrial Ethernet Extender WeOS

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

User Guide. Westermo Teleindustri AB Lynx DSS. WeOS. Industrial Ethernet Device Server Switch.

Support Services. Industrial Data Communications

GAN9.9T153A-B Product Specifications

ODW-621 Fibre Optic Modem

Lynx. Industrial Ethernet 10-port Switch L110 / L210. User Guide

OV504WN Parameters and Specifications

User Guide. Westermo Teleindustri AB RedFox Industrial. WeOS. Industrial Routing Switch.

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

Industrial Routing Switch

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy

User Guide. Westermo Teleindustri AB 2006 EDW Serial Adapter.

ODW-622 Fibre Optic Modem

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

User Guide Westermo Teleindustri AB EDW-100. Serial Adapter.

User Guide. Westermo Teleindustri AB MCW-211. Industrial Ethernet Media Converter.

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

+70 C -25 C 95% RH EMC

MCW-211-F1G-T1G. Industrial Ethernet Media Converter.

OnCell G3150A-LTE Series

Trackside Networks. Solutions for Railway and Trackside Applications. Robust Industrial Data Communications Made Easy

Industrial Serial Device Server

TK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

User Guide Westermo Teleindustri AB TDW-33. DIN-rail Tele V.90 modem.

NASCOM V1800VWL-AC. Description. Applications Diagram. AD/VDSL VOIP 11AC WIFI IAD Router

DR-260. ADSL / ADSL2 / ADSL2+ Router. User Guide Westermo Teleindustri AB. LAN SIGNAL D B1 B2 3G/GPRS SIM 1 SIM 2

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

DIN Rail RTU 540CMD01 Data sheet

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

4-Ethernet Ports Router & WLAN (802.11n 1x1)ADSL2/2+

EDR-G902/G903 Quick Installation Guide

MW5501C Series MW5502C Series. 1 or 2-Port Industrial Wireless Modbus TCP/RTU/ASCII Gateway FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

KX/3G ADSL2+ ROUTER MAIN FEATURES

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

SE5908A Series SE5916A Series. 8 or 16-Port IEC Certified Industrial Rack-Mount Secure Serial Device Server FEATURE HIGHLIGHTS

Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

User Guide. Westermo Teleindustri AB DDW-220. Wolverine series DDW-220. Industrial Ethernet SHDSL extender.

RSA-4222W. Remote Site Access Router with ADSL/VDSL2, Ethernet and cellular wireless WAN ports. Introduction. Features

FOUR-PORT ADSL ROUTER. KD319RI ADSL Router User Manual

User Manual Anybus Serial Server

IPL-E Router Firewall USER GUIDE

Support 1 RS-232 or RS-485/422 serial port to 1 10/100Base-T(X) self-adaptive Ethernet interface

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Hardened Ethernet Switch. Signamax Connectivity Systems. Hardened Ethernet Switch. Model G Series. User s Guide

MGate 5105-MB-EIP Series

NetBiter Serial Server User Manual

FOUR-PORT ADSL ROUTER. KD319MUI ADSL Router User Manual

OV604WVB Bonding Product Specifications

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

TN-5308 Quick Installation Guide

Rugged Industrial Media Converter

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

TD-8616 ADSL2/2+ Ethernet Modem

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Modbus TCP/RTU Gateway

Signamax Connectivity Systems

Industrial Ethernet Switch. Signamax Connectivity Systems. Industrial Ethernet Switch. Model A Series. User s Guide

Tel: Fax:

XPress-Pro SW User Guide

CHAPTER 7 ADVANCED ADMINISTRATION PC

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

HEC. General Operating, Maintenance and Installation Manual

MGate 5111 Quick Installation Guide

MySC140-WN ADSL2/2+ Router Product Specifications

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

XPress-Pro SW User Guide

Telindus 2400 Series

Transcription:

User Guide 6623-2232 BRD-355 Westermo Teleindustri AB Industrial ADSL/VDSL Router www.westermo.com

Legal information The contents of this document are provided as is. Except as required by applicable law, no warranties of any kind, either express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are made in relation to the accuracy and reliability or contents of this document. Westermo reserves the right to revise this document or withdraw it at any time without prior notice. Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused. More information about Westermo can be found at the following Internet address: http://www.westermo.com 2 6623-2232

Safety!! Before installation: Read this manual completely and gather all information on the unit. Make sure that you understand it fully. Check that your application does not exceed the safe operating specifications for this unit. The unit must be installed by a service person and connected to a protective earthing contact. Disconnect all telecommunication network connectors and cable distribution system connectors before disconnecting the protective earthing contacts. This unit should be built-in to an apparatus cabinet, or similar, where access is restricted to service personnel only. The power supply wiring must be sufficiently fused, and if necessary it must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. This unit uses convection cooling. To avoid obstructing the airflow around the unit, follow the spacing recommendations (see Cooling section). This unit uses negative earth, therefore the 0 V and protective earth must be connected to ensure robust functionality. Before mounting, using or removing this unit: Prevent access to hazardous voltage by disconnecting the unit from power supply. Warning! Do not open connected unit. Hazardous voltage may occur within this unit when connected to power supply. Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations. This unit must not be operating with removed covers or lids. Do not attempt to disassemble the unit. There are no user serviceable parts inside. Do not drop, knock or shake the unit, rough handling above the specification may cause damage to internal circuit boards. Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit. Do not paint the unit. Paint can clog the unit and prevent proper operation. Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not waterproof. Keep the unit within the specified humidity levels. Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical parts may be damaged. If the unit is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo Tech support. Maintenance No maintenance is required, as long as the unit is used as intended within the specified conditions. 6623-2232 3

Agency approvals and standards compliance Type EMC Safety Approval / Compliance EN 61000-6-1, Immunity residential environments EN 61000-6-2, Immunity industrial environments EN 61000-6-3, Emission residential environments EN 61000-6-4, Emission industrial environments EN 60950-1, IT equipment 4 6623-2232

Declaration of Conformity, BRD-355 Westermo Teleindustri AB Declaration of Conformity The manufacturer Westermo Teleindustri AB SE-640 40 Stora Sundby, Sweden Herewith declares that the product(s) Type of product Model Art no ADSL / VDSL Router BRD-355 3623-0311 is in conformity with the following EU directive(s). No Short name 2014/30/EU Electromagnetic Compatibility (EMC) 2014/35/EU 2011/65/EU Low Voltage Directive (LVD) Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) References of standards applied for this EU declaration of conformity. No Title Issue EN 55024 Information technology equipment Immunity characteristics Limits and methods of measurement 2010 +A1:2015 EN 55032 Information technology equipment Radio disturbance 2014 Characteristics limits and methods of measurement EN 60950-1 Information technology equipment -- Safety -- General requirements 2006 +A11:2009 +A1: 2010 +A12:2011 +A2: 2013 EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances 2012 Pierre Öberg Technical Manager 4 th October 2017 Org.nr/ Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 6623-2232 5

Type tests and environmental conditions Phenomena Test Description Test levels ESD EN 61000-4-2 Enclosure contact ± 6 kv (crit A) Enclosure air ± 8 kv (crit A) Radiated RF immunity IEC 61000-4-3 Enclosure 20 V/m (crit A) (80 2700 MHz) Fast transient EN 61000-4-4 DC power ports ± 2 kv (crit A) Ethernet ports ± 2 kv (crit A) Serial port ± 2 kv (crit B) xdsl ports ± 2 kv (crit B) Surge EN 61000-4-5 DC power ports ± 2 kv (crit A), 42 Ω ± 500 V (crit A), 12 Ω Ethernet ports ± 2 kv (crit A), (shielded cable) xdsl ports ± 2 kv (crit B) RF conducted EN 61000-4-6 DC power ports 10 V/m, (crit A), (0.15 80 MHz) Ethernet ports xdsl ports Radiated emission CISPR 16-2-3 Enclosure EN 61000-6-3 Conducted emission CISPR 16-2-1 DC power ports CISPR 32 Temperature EN 60068-2-1 EN 60068-2-2 Ethernet ports xdsl port Operating Storage & Transport 3 V/m, (crit A), (0.15 80 MHz) 10 V/m, (crit B), (0.15 80 MHz) 3 V/m (crit A), (0.15 80 MHz) 10 V/m (crit B), (0.15 80 MHz) EN 61000-6-3 25 to +70 C ( 13 to +158 F) 40 to +85 C ( 40 to +185 F) Humidity EN 60068-2-30 Operating 0 to 90% relative humidity non condensing. Storage & Transport 0 to 90% relative humidity non condensing. Altitude Operating 2000 m / 70 kpa Service life Operating 10 year Dimension W x H x D 53 x 103 x 97 mm (2.08 x 4.05 x 3.81 in) Weight 0.40 kg Degree of protection IEC 529 Enclosure IP 40 Cooling Convection Mounting Horizontal on 35 mm DIN-rail 6 6623-2232

Description Remote access removes boundaries, eliminates the need for time consuming site visits and provides a network infrastructure suitable for today's always-on society. The BRD- 355 is an industrially designed xdsl (ADSL/VDSL2) broadband router built to cope with harsh environments and the characteristics of industrial applications. The unit supports a wide range of xdsl-standards and has support for long lines. Most devices today comes equipped with an Ethernet port for communications, therefore the BRD-355 has a built-in two port Ethernet switch. For legacy connectivity the unit also features one RS-232-port to provide multiple connection possibilities for both new and legacy replacement installations. Designed to be installed on a DIN-rail all connectors and LEDs have been positioned in the front of the unit, facing the user for easy access and fast status feedback. With wide power input range, the unit can be powered from 10 to 60 VDC and has low power consumption. The cyber security features of the BRD-355 prevent unauthorized access and secure the communication for Internet-enabled applications. The easy to use firewall filters incoming traffic, allowing only approved packets to pass through. To inter-connect units with each other securely over the Internet multiple VPN technologies are supported, including IPsec and OpenVPN. Upgrading legacy solutions to become IP-enabled can prove both costly and tedious therefore the BRD-355 includes a wide feature set for various legacy applications including both modem replacement methods as well as serial to Ethernet conversion. If there are applications that require extra attention Westermo's extensive experience from over 35 years within industrial data communications and over 5 years of industrial xdsl expertise will be available to assist you. 6623-2232 7

Interface specifications Power Rated voltage Operating voltage Operational current (max) Rated current (max) Rated frequency 12 48 VDC 10 60 VDC 450 ma @ 12 VDC 1000 ma @ 12 VDC DC RS-232 Electrical specification EIA RS-232 Data rate 300 bit/s 115.2 kbit/s Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits Protocol Transparent, optimised by packing algorithm Circuit type SELV Transmission range 15 m / 49 ft Connection 9 pin D-sub female Shielded cable Not required Conductive housing Yes Number of ports 1 Ethernet TX Electrical specification IEEE std 802.3. 2005 Edition Data rate 10 Mbit/s, 100 Mbit/s, manual or auto Duplex Full or half, manual or auto Circuit type SELV Transmission range 100 m / 328 ft Isolation to All other Connection RJ-45 auto MDI/MDIX Shielded cable Not required Conductive housing Yes Number of ports 2 8 6623-2232

DSL Protocol Connection LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA 1 x RJ-11 Version Common name Standard Downlink Uplink ADSL ADSL ANSI T1.413 8 Mbit/s 1.0 Mbit/s ADSL (G.dmt) ITU G.992.1 8 Mbit/s 1.0 Mbit/s ADSL (G.lite) ITU G.992.2 1.5 Mbit/s 0.5 Mbit/s ADSL over POTS ITU G.992.1 Annex A 12 Mbit/s 1.3 Mbit/s ADSL over ISDN ITU G.992.1 Annex B 12 Mbit/s 1.8 Mbit/s ADSL2 RE-ADSL ITU G.992.3 Annex L1/L2 5 Mbit/s 0.8 Mbit/s ADSL2 ITU G.992.3 12 Mbit/s 1.3 Mbit/s ADSL2 Annex J ITU G.992.3 Annex J 12 Mbit/s 3.5 Mbit/s ADSL2+ ADSL2+ ITU G.992.5 24 Mbit/s 1.4 Mbit/s ADSL2+ Annex M ITU G.992.5 Annex M 24 Mbit/s 3.3 Mbit/s VDSL2 VDSL2 ITU G.993.2* 100 Mbit/s** 100 Mbit/s** VDSL2 Vectoring ITU G.993.5 G.Vector 100 Mbit/s** 100 Mbit/s** * Supports profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 30a. ** Maximum sustained routing performance over time is around 35 Mbit/s. 6623-2232 9

Connections DSL-connection Ethernet TX Connections (RJ-45 connector) LAN1-2 Position Direction Description 1 In/Out TD+ 2 In/Out TD 3 In/Out RD+ 4 Not Connected 5 Not Connected 6 In/Out RD 7 Not Connected 8 Not Connected Factory default reset switch Led indicators Protective Earth Router Serial Port (DCE Female) Position Name Direction Description 1 DCD Out Data Carrier Detect 2 RxD Out Receive Data 3 TxD In Transmit Data 4 DTR In Data Terminal Ready 5 SG Signal Ground 6 DSR Out Data Set Ready 7 RTS IN Request to Send 8 CTS Out Clear to Send 9 RI Out Ring Indicator 9 6 5 1 Power connector 2-position Product marking Direction Description 2 1 No. 1 + Input Supply voltage input DC No. 2 Input Common 10 6623-2232

LED Indicators LED Status Description STS Status xdsl Link status RED RED FLASH GREEN Indicates a fault, except during boot-up Indicates a fault, except during boot-up All OK GREEN & ONE RED FLASH All OK but no VPN peer connected OFF GREEN FLASH GREEN No ADSL connection Negotiating with the provider DSLAM All OK, ADSL link established STS LED Status indicator The status indicator reports the health of the unit. In normal operation the indicator will be green, however, if a fault is detected, either at boot-up or during normal operation, the indicator will light red. When the unit is first switched on or is reset, the indicator will first light red then flash red. This is normal behavior during boot-up and does not indicate a fault. Configuring a VPN connection in the BRD-355 and activating the service will cause the STS LED to be lit GREEN but FLASH RED every third (3) second to indicate that no peer is connected on the VPN. The feature of the VPN status in the STS LED makes it easy for staff to see whether or not the VPN connection is working without having to login to the device. DSL LED xdsl link status The DSL LED reports the status of the connection to the network. When powered up the indicator will be off, the indicator will then flash green whilst the unit tries to negotiate the link with the provider DSLAM, once successfully connected to the provider the indicator will light green to indicate that everything is ready and functioning on the xdsl link level. 6623-2232 11

Factory Default Reset Switch The reset switch is used to restore the configuration of the BRD-355 to the factory default settings (for details about the default settings see the Getting started section). The switch is accessed through a small hole, adjacent to the xdsl and STS LEDs, labeled C on the front of the unit. To reset the configuration: Power down the unit. Using a suitable tool depress the reset switch. Power up the unit ensuring the switch remains depressed for approximately 5 seconds after power is applied. The STS LED will flash twice to indicate a reset. Once the unit has booted-up it will use the default settings. Note: Using the factory default reset switch will erase all existing configuration settings and restore the factory default settings. Factory default reset switch 12 6623-2232

Protocols and Functionality Ethernet Technologies xdsl Technologies Serial Port Technologies IP Routing, Firewall, VPN and Cyber Security Manageability IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseTX Layer-2 QoS IEEE 802.1p Class of Service RFC2684 Bridged LLC and Bridged VC-MUX ATM encap. (ADSL) TR-067 Compliance Dying Gasp support ITU K.21 Support Rate adaptive modem at 32 Kbps steps ATM Layer with traffic shaping QoS support (UBR, CBR, VBR-rt,VBR-nrt) AAL5 AAL F5 OAM Loopback/Send and receive RFC2364 PPPoA client support RFC2516 PPPoE client support RFC2225 / RFC1577 Classical IP Support PAP/CHAP/MS-CHAP for Password Authentication support RS-232 Serial Over IP (Serial Extender and Virtual Serial Port) Modem emulation AT command interpreter MODBUS DNP3 Static IP routing Dynamic IP routing RIPv1/v2 VRRP GRE Stateful inspection Firewall / ACL, NAT, Port Forwarding 25 x IPsec VPN, PSK & X.509 1 x L2TP client 1 x PPTP client 1 x OpenVPN / SSL VPN client RADIUS PPP Dial in/dial out Management tools Web-interface (HTTP and HTTPS) Command Line Interface (CLI) via SSHv2 and TELNET SNMPv1/v2c/v3 Syslog (log files) SNTP (NTP client) DHCP client DHCP server DDNS (Dynamic DNS update client) For more information on the features and functionality, please refer to the Management Guide on the product website. 6623-2232 13

Getting started Power Supply The BRD-355 requires a DC power source in the voltage range of 10 to 60 VDC. The unit is designed to self protect from permanent damage if the voltage exceeds 60 VDC or if reverse polarity is applied. The router may need to be returned for service if this occurs. The router can also be damaged if there is any potential difference between the chassis-ground, RS-232 signal ground or power ( ) input. Before connecting any wiring, ensure all components are earthed to a common ground point. An external isolator will be required if a positive earth power supply is used. Ethernet The Ethernet ports are on the front of the unit and are marked LAN 1 and LAN 2, each port has a LED indicating the connection speed and a LED indicating activity as shown in figure below. Both ports are capable of auto-negotiation, meaning cross-over cables are not required. The Ethernet ports are switched, allowing more than one Ethernet device to be connected to the unit at one time. Activity LED Connection speed LED 14 6623-2232

Configuration Accessing and Using the Web Interface All configuration of the BRD can be done via the web interface. In order to view the web pages a computer with a fixed IP address, on the same sub-net as the BRD, will need to be connected to one of the LAN ports. The default IP settings of the BRD are: IP Address: 192.168.2.200 Netmask: 255.255.255.0 The recommended IP settings for the PC used to configure the BRD Router: IP Address: 192.168.2.100 Netmask: 255.255.255.0 Default Gateway: 192.168.2.200 Primary DNS: 192.168.2.200 Note: Although it is possible to connect the BRD directly to a Local Area Network (LAN) it is recommend that the network configuration as described in this section is performed prior to doing so. The DHCP server of the unit is by default disabled. Windows PC Network Settings The following describes how to configure the network settings of a PC with Windows 7 so that it can access the BRD. Note: This procedure will change the network settings of the Windows PC, if the PC is connected to a network the connection should be removed before performing the changes. To restore the network settings of the PC, record the current settings at Step 7 in the following procedure. When the BRD has been configured, follow the procedure again and use the recorded values at Step 7. 1. Open the Control Panel by selecting Start > Control Panel. 2. Click the Network and Sharing Center icon. 3. Click Change Adapter Settings. 4. Double click the Network icon. 5. The Local Area Connection Status dialog box will be displayed, click the Properties button. 6. The Local Area Connection Properties dialog box, as shown in Figure 1, will be displayed Click on Internet Protocol (TCP/IPv4) to highlight it and then click the Properties button. 6623-2232 15

Figure 1 7. The Internet Protocol (TCP/IP) Properties dialog box, change the settings to match those shown in Figure 2, and then click OK. Figure 2 Note: If a web browser was open prior to making the network changes, it will need to be closed and re-started before attempting to connect to the BRD. 16 6623-2232

Mounting This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet or similar. Snap on mounting, see figure. Mounting the BRD-355 with integrated DIN-clip: Cooling The router should be mounted in a clean and dry location, protected from water, excessive dust, corrosive fumes, extremes of temperature and direct sunlight. Allow sufficient ventilation to ensure adequate cooling of the router. 10mm 10mm 6623-2232 17

Denomination Designer Drawing No. Approved Scale Status Dimensional drawing 92.3 53 (mm) 103 36 92.3 Pos No Quantity Description Dimensional Drawing BRD-355 Designation / Dimension Material / Remark Date 230117 1 18 6623-2232

6623-2232 19

Westermo SE-640 40 Stora Sundby, Sweden Tel +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com www.westermo.com Sales Units Westermo Data Communications Australia info@westermo.net.au www.westermo.net.au China sales.cn@westermo.com www.cn.westermo.com Finland tiedot@westermo.fi www.westermo.fi France infos@westermo.fr www.westermo.fr Germany info@westermo.de www.westermo.de North America info@westermo.us www.westermo.us Singapore sales@westermo.com.sg www.westermo.com Sweden info.sverige@westermo.se www.westermo.se United Kingdom sales@westermo.co.uk www.westermo.co.uk Other Offices For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code REV. A 6623-2232 2017-09 Westermo Teleindustri AB, Sweden