SK TU4-PNT-M12 Part number:

Similar documents
SK CU4-PNT-C Part number:

SK TU4-PBR Part number:

SK TU4-CAO-C Part number:

SK CU4-EIP-C Part number:

SK CU4-PBR-C Part number:

SK CU4-CAO Part number:

SK CU4-ECT-C Part number:

SK TU4-IOE-M12-C Part Number

SK TU4-PNS-M12 Part number:

SK TI4-TU-MSW Part number:

SK EPG-3H Part number:

BU 0220 GB. Intelligent Drivesystems, Worldwide Services SUPPLEMENTARY MANUAL BU 0220 GB PROFIBUS DP FOR FREQUENCY INVERTER NORDAC SK 200E

BU 0280 GB. Intelligent Drivesystems, Worldwide Services SUPPLEMENTARY MANUAL BU 0280 GB DEVICENET FOR FREQUENCY INVERTER NORDAC SK 200E

EN BU PROFINET IO bus interface. Supplementary manual options for NORD - Frequency Inverters

About this document BU Control and Parameter Boxes for NORDAC Frequency Inverters. BU 0040 GB-1611 Subject to technical alterations 1

BU PROFINET Bus module for NORD frequency inverters SK 5xxE. BU 0590 GB-0312 Subject to technical amendments 1

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

Operating instructions RFID evaluation unit DTE / / 2016

BNI PNT Z015. IP67 Modules 16 Input User s Guide

VersaMax IP Input Module

EN BU Functional Safety. Supplementary manual for series SK 500E

IP gateway, MDRC IG/S 1.1, GH Q R0001

modunet292: novanet-ethernet interface

Date Revision Change(s) First version

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Operating instructions Evaluation system for flow sensors VS / / 2013

Industrial Serial Device Server

X20(c)BC00E3. 1 General information. 2 Coated modules. X20(c)BC00E3

ETHERNET/IP & PROFINET MODULE

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Sauter Systems

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

RTU560 Connections and Settings DIN Rail RTU 560CIG10

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

Device manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Technical Description

EN BU CANopen bus interface. Supplementary manual options for NORD - Frequency Inverters

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

VERSAMAX IP PROFINET SCANNER. 1 Description. GFK-2760 June 2012

Date Revision Change(s) 29/07/ First version

Network nodes with gateway

FL MC 2000E (SM40) LC

EY-RU 355: Room operating unit, ecounit355

GS Dupline Profinet Gateway. Benefits. Description

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

Intelligent Drivesystems, Worldwide Services SK 135E. Starter with soft start and reversing function

Instruction Manual Power Distribution System SVS16-PN-XX

VersaMax IP I/O Module

PROFIBUS MODULE (CB15) English Operating Instructions. Contents. Warning and Caution Notes

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Operating instructions. Speed monitor D / / 2014

C-DIAS EtherNet/IP Slave CIP 022

LVX Control Unit. Features:

Ethernet/SIOX Gateway Applicable to firmware ver 1.0

Installation Instructions Temperature transmitter TAA /00 06/2011

User Manual Gateway component for EtherNet/IP

Contents 1. Summary

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

EN BU Functional Safety. Supplementary manual for series SK 200E

hipecs-cio100 CANopen I/O module with 16/16 digital I/O

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

BNI EIP Z016 IP67 Modules, 16 In-/Outputs User s Guide

GFK-2415A March Type of sensor connection

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Industrial Switches Industrial Switches

IFC 300 Supplementary Instructions

Profinet Module. User Manual. Contents

Instruction Manual Power Distribution System SVS16-EN-XX

Multifunctional time delay relay MFT U31S, MFT U41SE

Assembly Instructions scancontrol 2700/2750 (500)

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

Operating Manual FPGA-based High-Speed Micro-PLC

Installation instructions Inclination sensor EC2019 EC / / 2013

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Ethernet/IP Module. User Manual. Contents

Original operating instructions Safety relay with relay outputs G1501S / / 2016

SCHMIDT Sensor interface PROFIBUS Instructions for use

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web: -

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

mipick Pick-by-Light System

Compact Multiprotocol I/O Module for Ethernet 16 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs TBEN-L4-16DXP

Operating instructions. Switching amplifier DN0210 DN / / 2015

Modbus TCP/RTU Gateway

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

Protected VARAN Digital Mixed Module PVDM 086

Operating Instructions Webmodule ZB-S

High Performance AC Vector Drives

Transcription:

Pos : 14 /T echnisc he Informati onen/sk xu x - Er weiterungen/prof INET IO/SK TU 4-PN T-M12 / 275281122 / Basisinformationen_2 [SK TU4-PN T-M12] @ 13\mod_1475843683170_388.docx @ 2264311 @ 555 @ 1 Pos : 6 /T ec hnis che Infor mationen/sk xu x - Er weiter ung en/pr OFIN ET IO/SK TU4- PNT-M12 / 275281122 / Basisinformationen [SK TU4- PNT-M12] @ 4\mod_1385372069592_388.docx @ 106426 @ @ 1 SK TU4-PNT-M12 Part number: 275 281 122 PROFINET IO External Bus Interface Pos : 8 /T ec hnis che Infor mationen/sk xu x - Er weiter ung en/allgemein - Systemübergreifend/War nhi nweis e_ti_s_bussc hitts tell en_allgemei n [SK xu x-...] @ 13\mod_1475837761064_388.docx @ 2263751 @ @ 1 The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their technical training and experience, has sufficient knowledge with regard to Switching on, switching off, isolating, earthing and marking power circuits and devices, Proper maintenance and use of protective devices in accordance with defined safety standards. DANGER Danger of electric shock The frequency inverter carries hazardous voltage for up to 5 minutes after being switched off. Work must not be carried out unless the frequency inverter has been disconnected from the voltage and at least 5 minutes has elapsed since the mains was switched off! NOTICE Validity of document This document is only valid in conjunction with the operating instructions of the respective frequency inverter and the bus communication manual for this bus interface ( See overview at end of document). These documents contain all of the information that is required for safe commissioning of the bus interface module and the frequency inverter. Scope of delivery 1 x Bus interface SK TU4-PNT-M12 4 x Hexagonal socket screw M4 x 40 mm Accessories required: 1 x Bus connection unit SK TI4-TU-BUS TI 275280000 (Part No.: 275 280 000) Usage area External technology unit for connection of a decentralised frequency inverter (SK 180E SK 2xxE) to a PROFINET IO field bus. The bus interface can be mounted on, or in the immediate vicinity of the frequency inverter. This is connected to the inverter via the system bus, and can directly access up to 4 frequency inverters. 8 digital inputs and 2 digital outputs are available. Technical Information / Datasheet SK TU4-PNT-M12 PROFINET IO Bus module TI 275281122 V 1.4 4217 en

Pos : 17 /Allgemein/Allgemeing ültige M odul e/---------seitenumbruc h kompakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1 Technical Data Bus interface Temperature range -25 C...50 C Vibration resistance 3M7 Temperature class Class 3K3 Firmware version V1.4 R4 Protection class IP55 Hardware version AA Supply voltage 24 V ± 20 %, 100 ma reverse polarity protected Dimensions [mm]* H x W x D: 95 x 136 x 99 *bus interface fitted to bus connection unit Depth: 108 mm with cover caps on M12 connection Digital input - working range Digital input - specific data Digital output - 24 VDC power supply Digital output - working range Low: 0 V 5 V, High: 15 V 30 V R i = 8 kω, input capacity: 10 nf, response time 10 ms, inputs as per EN 61131-2 type 1 400 ma (input) Low = 0 V, High = 24 V; max. 200 ma Bus specification PROFINET IO max. 100 MBaud Cable Min. Ethernet CAT-5 electrical isolation 500 V eff Max. cable length 100 m between two bus interfaces Bus connection 2 x M12 Shield via M12 direct to PE Bus termination performed automatically PE connection via PE screw cap in Status display 8 LEDs terminal box Topology Star, tree, ring, line Power Update interval for process data between bus interface and frequency inverter Parameter read access on the frequency inverter Parameter write access with storage in EEPROM Cycle times 5 ms 15 ms 25 ms 1 ms 2 / 10 TI 275281122-4217

Pos : 18 /T echnisc he Informati onen/sk xu x - Er weiterungen/prof INET IO/Mer kmale [PNT Allgemei n] @ 4\mod_1385365458675_388.docx @ 106301 @ 5 @ 1 Pos : 21 /T echnisc he Informati onen/sk xu x - Er weiterungen/allgemei n - Sys temübergreifend/m ontag e [SK TU4- xxx- xxx] @ 2\mod_1353315135994_388.docx @ 51251 @ 5 @ 1 Pos : 26 /T echnisc he Informati onen/sk xu x - Er weiterungen/allgemei n - Sys temübergreifend/anschl üss e - Ether nets eite - Variante M 12 [SK TU4-...EIP/ECT /POL/PNT(-M12)...-C)] @ 4\mod_1385383150995_388.docx @ 106697 @ 5 @ 1 Pos : 28 /Allgemein/Allgemeing ültige M odul e/---------seitenumbruc h kompakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1 Bus interface characteristics Communication RT (Real Time) Real time communication of process data IRT (Isochronous Real Time) Isochronous real time communication of synchronised process data Addressing PROFINET IO Automatic address assignment via IO controller using DCP (Discovery Configuration Protocol) Data transfer via Switched Ethernet Autonegotiation Negotiation of transfer parameters Autocrossover Transmission and receiver cables are automatically crossed in the switch as necessary Conformity classes CC-B and CC-C Access for NORD diagnosis tool via Diagnostics socket on the device (if available) and via frequency inverter Ethernet protocols UDP or TCP/IP possible Installation The bus interface must be attached to a suitable connection unit (SK TI4-TU ) and connected using the 4 provided M4 x 40 mm hexagon socket collar screws. Installation details can be found in the data sheet for the relevant connection units. Connections The two Ethernet lines are connected exclusively via the two M12 sockets on the front. If the bus interface is the final subscriber on the line, one M12 socket can remain unoccupied. The use of EMC cable glands is recommended. PIN Signal Description 1 TX+ Transmission Data + 2 RX+ Receive Data + 3 TX- Transmission Data - 4 RX- Receive Data - PIN assignment M12-4 socket ("D"- coded) TI 275281122-4217 3 / 10

Pos : 29 /T echnisc he Informati onen/sk xu x - Er weiterungen/allgemei n - Sys temübergreifend/anschl üss e - Klemmenl eiste [SK TU 4(-C) - EtherNet Baugruppen allgemein] @ 3\mod_1362998963057_388.docx @ 61424 @ @ 1 The connection to other signal and control lines takes place via the bus connection unit SK TI4-TU-BUS(-C). Terminals Double-sprung terminal bar 2 x 18 contacts Cable cross section AWG 14-26 rigid: 0,14 2,5 mm flexible: 0.14 1.5 mm with wire end sleeves PE connection Via housing RJ12 RJ45 - socket Interface for connecting a parameterisation tool Potential Contact Designation Description 1 24 V Supply potential (+24 V, 200 ma) 2 24 V Supply potential (+24 V, 200 ma) 3 DIN5 Digital input 5 1 Digital inputs 2 System bus level and digital inputs 3 Digital outputs 4 Diagnosis 4 DIN7 Digital input 7 5 DIN6 Digital input 6 6 DIN8 Digital input 8 7 0 V Reference potential (0 V / GND) 8 0 V Reference potential (0 V / GND) 9 24 V Supply potential (+24 V, 200 ma) 10 24 V Supply potential (+24 V, 200 ma) 11 24 V Supply voltage (+24 V) 12 24 V Supply voltage (+24 V) 13 24 V Supply voltage (+24 V) 14 SYS + System bus data line + 15 0 V Reference potential (0 V / GND) 16 SYS - System bus data line - 17 0 V Reference potential (0 V / GND) 18 0 V Reference potential (0 V / GND) 19 DIN1 Digital input 1 20 DIN3 Digital input 3 21 0 V Reference potential (0 V / GND) 22 0 V Reference potential (0 V / GND) 23 24 V Supply voltage (+24 V) 24 24 V Supply voltage (+24 V) 25 DIN2 Digital input 2 26 DIN4 Digital input 4 27 0 V Reference potential (0 V / GND) 28 0 V Reference potential (0 V / GND) 29 24 V Supply voltage (+24 V) 30 24 V Supply voltage (+24 V) 31 VI 24V2 Supply potential (+24 V - in) of the digital outputs 32 0V2 Reference potential (0 V / GND) of the digital outputs 33 DOUT1 Digital output 1 (+24 V, 200 ma) 34 DOUT2 Digital output 2 (+24 V, 200 ma) 35 0V2 Reference potential (0 V / GND) of the digital outputs 36 0V2 Reference potential (0 V / GND) of the digital outputs RJ12-1 RS485_A Data cable RS485 RJ12-2 RS485_B Data cable RS485 RJ12-3 GND Reference potential (GND) RJ12-4 RS232_TxD Data cable RS232 RJ12-5 RS232_RxD Data cable RS232 RJ12-6 24 V Supply voltage (+24 V) 4 / 10 TI 275281122-4217

Pos : 30 /T echnisc he Informati onen/sk xu x - Er weiterungen/allgemei n - Sys temübergreifend/anschl uss beispi ele [BU S Allgemei n] @ 19\mod_1502194893730_388.docx @ 2362489 @ 6 @ 1 Pos : 34 /T echnisc he Informati onen/sk xu x - Er weiterungen/prof INET IO/Konfigur ation [SK TU 4-PNT(-C(-M12))] @ 4\mod_1385046026847_388.docx @ 106049 @ 5 @ 1 Pos : 35 /Allgemein/Allgemeing ültige M odul e/---------seitenumbruc h kompakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1 Connection examples Connection of voltage supply and Systembus VI 24V GND/0V SYS+ SYS- Brown Blue Black Grey 24 V DC GND/0V Systembus + Systembus- bus module Configuration Configuration of the bus interface module for remote maintenance or for the system bus is carried out via the DIP switches. The DIP switch settings are read after a "Power On" of the bus interface. DIP switch 12 11 10 9 8 7 6 5 4 3 2 1 X X X No function X 0 System bus terminating resistor not set. 1 System bus terminating resistor set. Access rights for remote maintenance 0 Only read access to parameters possible. 1 Read and write access to parameters possible. 0 No control possible. 1 Control is possible. 0 TCP/IP open connection. 1 Secure TCP/IP connection. 1. System bus (DIP 1) The system bus must be terminated at both physical ends. 2. (DIP 2... 9) No function. 3. Access rights for remote maintenance (DIP 10... 12) The bus interface and the connected frequency inverter can be accessed using remote maintenance via the Ethernet TCP and UDP protocols. The type of access is defined via the DIP switch with inputs 10 to 12. ON OFF 1 12 Factory settings DIP switches: OFF TI 275281122-4217 5 / 10

Pos : 39 /T echnisc he Informati onen/sk xu x - Er weiterungen/prof INET IO/LED Anzeig en [SK TU 4-PNT-M 12(-C)] @ 4\mod_1385377321045_388.docx @ 106647 @ 5 @ 1 Pos : 41 /Allgemein/Allgemeing ültige M odul e/---------seitenumbruc h kompakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1 LED indicators The operating statuses of the bus interface are visualised using LED indicators. No. Name Colour RUN green Ethernet State 1 BF red Ethernet Error DS green Device State EN red Device error 2 Link green Link Act yellow Activity Pos : 40 /T echnisc he Informati o nen/ SK xu x - Er weiterungen/prof INET IO/LED Anzeig en- PROF INET s pezi fische LED [PNT Allgemei n] @ 4\mod_1385130089638_388.docx @ 106275 @ @ 1 PROFINET-specific LED RUN (Ethernet State) OFF Flashing green Green ON No operating voltage Initialisation No connection to PROFINET IO controller No parameter communication No process data communication Parameter communication active Process data communication active BF (Ethernet Error) OFF Flashing red Red ON Double-flashing red (2 x 0.25 s,+ 1sec pause) No error No process data communication e.g. incorrect GSDML file Ethernet error there is no physical connection to a further subscriber PROFINET or FU timeout, (see also P151, P513) Link (Green LED) Activity (Yellow LED) OFF OFF Bus interface not ready, no control voltage, No bus connection (check cable connection) ON OFF Bus connection (cable connection) to another Ethernet device exists No bus activity present ON Flashing (Blinking) Bus connection (cable connection) to another Ethernet device exists Bus activity present 6 / 10 TI 275281122-4217

Pos : 43 /Allgemein/Allgemeing ültige M odul e/---------seitenumbruc h kompakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1 Pos : 42 /T echnisc he Informati onen/sk xu x - Er weiterungen/allgemei n - Sys temübergreifend/led Anz eigen- NORD spezifische LED [EIP / POL / EC T / PNT Allgemein] @ 3\mod_1363773424248_388.docx @ 61815 @ @ 1 NORD-specific LEDs DS (Device State) EN (Device Error) long flashing short flashing = 0.5 s on / 1 s off = 0.25 s on / 1 s off OFF OFF Bus interface not ready, no control voltage ON OFF Bus interface ready, no error, at least one frequency inverter is communicating via the system bus ON Short flashing Bus interface ready, but One or more of the connected frequency inverters has fault status Long flashing OFF Bus interface ready and at least one other subscriber is connected to the system bus, but No frequency inverter on the system bus (or connection interrupted) One or more system bus subscriber has an address error Software incompatible (bus interface software and FI software incompatible - update required) Long flashing Long flashing Long flashing Long flashing OFF Short flashing Flash interval 1 x - 1s pause Short flashing Flash interval 2 x - 1s pause Short flashing Flash interval 3 x - 1s pause Short flashing Flash interval 4 x - 1s pause Short flashing Flash interval 1 7-1s pause System bus is in status "Bus Warning" Communication on system bus disrupted No other subscribers present on system bus Module not inserted correctly or no connection to system bus Frequency inverter has no supply voltage System bus is in status "Bus Off" The system bus 24 V power supply has been interrupted during operation System bus is in status "Bus Off" The 24V voltage supply of the system bus is missing Bus interface error See parameter P170 System error, internal program sequence interrupted EMC interference (observe the wiring guidelines!) Bus interface defective TI 275281122-4217 7 / 10

Pos : 44 /T echnisc he Informati onen/sk xu x - Er weiterungen/prof INET IO/F ehl ermel dungen Profi net Baugruppen allgemei n [SK xu x-pnt - Allgemein] @ 4\mod_1384961728468_388.docx @ 105889 @ 5 @ 1 Pos : 45 /Allgemein/Allgemeing ültige M odul e/---------seitenumbruc h kompakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1 Error messages Error messages from the bus interface - current or archived message relating to the last fault - can be read out via bus interface parameter P170. The error messages are lost if the bus interface is switched off. Error Remarks 100.0 EEPROM error EMC fault, bus interface defective 101.0 System bus 24 V missing No 24 V voltage on bus, connections not correct 102.0 Bus timeout P151 By means of timeout supervision parameter P151/P513 103.0 System bus Off No 24 V voltage on bus, connections not correct 104.0 Overtemp. Module Only SK CU4-PNT bus interface (see E10.7) 550.0 General configuration error No Ethernet connection (see E10.5) 550.1 IO hardware error Error on IO interfaces (see E10.4) 550.2 CAN hardware error EMC fault (see E10.6) 550.3 SAFE hardware error Error in the safety module 550.4 FI lost Connection to system bus participant (FI) lost 550.5 AR lost PROFINET telegram failure, connection to the IO controller lost (see E10.2) 564.0 MAC address error MAC address defective Errors which occur in relation to the bus interface are depicted as follows in the error memory of the frequency inverter (P700 / P701). Error (E010) Remarks 10.0 Connection error Contact to bus interface lost 10.2 PROFINET telegram failure Check physical bus connections Check the status of the PROFINET IO controller 10.3 Timeout through P151 System bus monitoring has triggered. Check time setting parameter P151 Telegram transfer is faulty. Reception of cyclic telegrams Check physical bus connections 10.4 Hardware error, IOs An error has occurred in the IO hardware Remedy EMC fault Restart the bus interface 10.5 General PROFINET configuration error No Ethernet detected at the port This error only occurs if there had previously been a connection to another IO device or switch 10.6 System bus hardware error Remedy EMC fault 10.7 CU4 temperature too high Only SK CU4-PNT bus interface: Excess bus interface temperature 10.8 Timeout connection error Connection between bus interface and frequency inverter interrupted due to timeout. 10.9 Module missing P120 Bus interfaces SK CU4-PNT and SK TU4-PNT only: The module entered in parameter P120 is not available. 8 / 10 TI 275281122-4217

Pos : 46 /T echnisc he Informati onen/sk xu x - Er weiterungen/allgemei n - Sys temübergreifend/par ameter [SK xu x-... Allgemein - Frequenzumric hter] @ 4\mod_1384953855694_388.docx @ 105781 @ 5 @ 1 Pos: 48 /Allgemein/Allgemeing ültige M odul e/---------seitenumbruc h kompakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1 Parameters Frequency inverter: The following frequency inverter parameters must be adapted for setting up communication between the frequency inverter and the bus interface (for details please refer to the frequency inverter manual). Parameter [-Array] Remarks P120 [-01] Option monitoring "Auto" (default setting) Only SK xu4 P509 Source Control Word SK TU3- on SK 5xxE: "Ethernet TU" SK xu4- on SK 180/SK 2xxE: "System bus" P510 [-01 ] [-02] Setpoint source "Auto" (default setting) P513 Time-out Monitoring of the SK TU3 bus interface Only SK 5xxE P543 [-01] [-03] ([-05]) and P543 P545 P546 [-01] [-03] ([-05]) and P546 P548 Bus actual value (1...3 (...5)) Bus setpoint value (1...3 (...5)) Possible settings according to P418 Possible settings according to P400 P700 [-01]/P701 Current/last faults Information parameter P740/P741 Process data bus In / Out Information parameter P745 Module version Information parameter Only SK TU3 P746 Module status Information parameter Only SK TU3 P748 CANopen/System bus status Information parameter Pos : 47 /T echnisc he Informati onen/sk xu x - Er weiterungen/prof INET IO/Par ameter [PNT Allgemein] @ 4\mod_1385367612358_388.docx @ 106326 @ @ 1 Bus interface: The bus interface provides a selection of appropriate parameters for setting or displaying special operating values. Parameters can be adapted using the NORDCON software or an SK PAR-3H / -3E parameter box. All parameters can still be read from and written to by the bus master via PROFINET IO. Parameter [-Array] Remarks -TU3- -TU4- -CU4- P150 Set relays Set DOUT directly or control via bus X P151 External bus time-out Monitoring of SK xu4 bus interface X X P152 Factory setting Reset bus interface parameters X X X P153 [-01 ] Minimum system bus Reduction of bus load on the system bus caused by the X X cycle bus interface P154 [-01 ] Access to option card I/O Administration of read and write permissions to the IOs of the bus interface X X P160 [-01 ] IP address X X X P161 [-01 ] IP subnet mask X X X P162 Device name Up to 240 characters (ASCII codes 45 122), save by X X X entering "0" as the final character P163 [-01 ] Alarm test Sets a diagnostic alarm X X X P164 [-01 ] IP Gateway IP-Address for Gateway functionality X X X P170 [-01 ] Present errors Indication of a bus interface error X X X P171 [-01 ] Software version Firmware version/revision X X X P172 Configuration Bus interface type X X X P173 [-01 ] Module status Status of system bus or the connected FI X X X P174 Status of digital inputs Image of the switching status of DIN X X P175 Digital output state Image of the switching status of DOUT X P176 [-01 ] Process data bus In Information parameter X X X P177 [-01 ] Process data bus Out Information parameter X X X P178 Internal temperature Information parameter X P180 [-01 ] PPO Type Information parameter X X X P181 [-01 ] MAC address Information parameter X X X P185 [-01 ] Present IP address Information parameter X X X P186 [-01 ] Current IP subnet mask Information parameter X X X P187 [-01 ] Actual IP Gateway Information parameter X X X P190 Status DIP-switches Information parameter X X X TI 275281122-4217 9 / 10

Pos : 49 /T echnisc he Informati onen/sk xu x - Er weiterungen/allgemei n - Sys temübergreifend/par ameterz ugriff und Di agnos e [Bus BG - Allgemei n] @ 3\mod_1363794074590_388.docx @ 61915 @ 5 @ 1 Pos : 52 /T echnisc he Informati onen/sk xu x - Er weiterungen/prof INET IO/Wei terführende D okumentati onen und Software [SK TU 4-PNT(-M12)] @ 4\mod_1385375411210_388.docx @ 106578 @ 5 @ 1 === Ende der Liste für T extmar ke Inhalt === Parameter access and diagnostics The NORD CON software and optional control units such as the SK PAR-3H parameter box provide convenient access to the parameters of the bus interface and allow status information to be read out. SK TU3- SK TU4- SK CU4- / SK TU4- Access via RJ12 diagnostics socket of the SK 5xxE Access via RJ12 diagnostics socket of the bus connection unit SK TI4-TU-BUS(-C) Access via RJ12 frequency inverter diagnostics socket, if connected to the bus interface via the system bus. Further documentation and software (www.nord.com) Software Description Software Description GSDML-file Device characteristics and parameters NORD CON Parametrisation and diagnostic software Document Description Document Description BU 0000 Description of NORD CON software BU 2400 PROFINET IO bus communication manual BU 0040 Parameter box manual TI 275280000 Bus connection unit SK TI4-TU-BUS BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275274505 SK TIE4-M12-SYSM System bus connection expansion exit BU 0200 Frequency inverter manual SK 2xxE TI 275274506 SK TIE4-M12-SYSS System bus connection expansion entrance 10 / 10 TI 275281122-4217