Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Similar documents
Mounting and Technical Data

Technical Information SMA STRING-MONITOR SSM-U-XX10 / SSM-U-XX15

Accessories for Sunny Central COMMUNICATION CABINET (COM-C)

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Technical data: Pin Spacing

Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

IF-80x Outdoor Terminal

KL 181 S-DIAS +24 V Potential Distributor Module

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

SUNCLIX Connection technology for photovoltaics

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

ATV1200A kv kva

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

PGR-3200 MANUAL INSULATION MONITOR

ATV1200A kv kva

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

PHOENIX CONTACT Features

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

JUMO Quantum PID100/PID200/PID300

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

DM 161 S-DIAS Digital Mixed Module

ASCO 920 Remote Control (RC) Switches

Product and functional description

ISOMETER isoev425 with coupling device AGH420

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

Grounding Monitoring Device Series 8485

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

SIMOCODE 3UF Motor Management and Control Devices

Installation / Control Technique

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Monitoring Relays. 3UG Monitoring Relays for Electrical and Additional Measurements. Line monitoring 7/61. Overview

8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW

Solid State Remote Power Controller E /627

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

Product and functional description

Operating instructions. Speed monitor D / / 2014

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

Disconnect Switches. Safe Switching and Disconnecting

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

RO 051 S-DIAS Relay Output Module

ISOMETER isopv with coupling device AGH-PV

ISOMETER isoev425/isoev425hc with coupling device AGH420

Item No.: /

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

920 Remote Control (RC) Switches

Safety Systems Safety Integrated

Product and functional description

Controlesta RCO-Compact

Product and functional description

Miniature Circuit Breakers for Railway Applications

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Fronius IG Plus. The next generation grid-connected PV inverter.

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

SLI 15 INVERTER SERIES, 1500 W

Safe monitoring relays

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Operating instructions. Switching amplifier DN0210 DN / / 2015

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

PHOENIX CONTACT - 07/2006

Item No.: /

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Extension module for lighting control

TM3AI4 module TM3-4 analog inputs

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

1492-SP Supplementary Protectors

RCMB20/RCMB Series

MC 11 EB-2 Power supply cabinet with external bus, AC version

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

2U Congestion Alert Rack Insert for UK

PV Rapid Shutdown device

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Section 4 Ground-Fault Protection Devices

Classification Enclosure rating Input voltage Type of

AO 081 S-DIAS Analog Output Module

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

E-STOP relay, safety gate monitor

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Transcription:

Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators. This Technical Information contains important information about the features and product details that are required for plant design. SSM24-11-UEN104913 Version 1.3 1/13

Product Details 1 Product Details With the Sunny String Monitor SSM24 11, SMA Solar Technology AG offers a detailed monitoring unit for large PV generators. The Sunny String-Monitor SSM24-11 continuously measures and compares the individual string currents. The analysis occurs in the Sunny Central Control. The Sunny String Monitor SSM24 11 is provided with 24 measuring channels to which 24 or 48 strings can be directly connected. The Sunny String Monitor SSM24 11 has string fuses at the positive and negative pole. For grounded PV generators, the Sunny String Monitor SSM24 11 can also optionally be equipped with cylindrical bridges at the positive or negative pole. The Sunny String Monitor SSM24 11 can be disconnected using a circuit breaker installed on the output side to the inverter. The circuit breaker is included in all Sunny String Monitor versions. The Sunny String Monitor SSM24 11 is equipped with monitored overvoltage protectors of category II. The Sunny String Monitor SSM24 11 has a pending utility patent. 2 Technical Data Enclosure Outdoor installation UV resistance Base installation* Wall mounting* Material Combustion properties Color Protective insulation Lock cylinder (double-bit) with switch cabinet key** Cable support rail*** Shaded Glass-fiber reinforced plastic Self extinguishing, halogen-free RAL7035 * optional ** prepared for customer mounting *** for plinth mounting only SMA Solar Technology AG 2/13

Technical Data Mechanical data, plinth Width x height x depth Installation depth of the plinth Weight Total weight, enclosure and plinth 1 060 mm x 894 mm x 245 mm 595 mm 16 kg 96 kg Mechanical data, enclosure Width x height x depth Weight 1 060 mm x 1 085 mm x 245 mm 80 kg General data DC power switch* 320 A Pollution degree** 2 * Direct drive ** according to DIN EN 50178:1997 Input Data at 40 C Ambient Temperature PV array configuration Negative or positive grounded, insulated Maximum permissible DC voltage U DC 1 000 V Maximum permissible DC current I DC 320 A Number of measurement inputs 24 Maximum number of connections per 2 measurement input* Possible string fuses 10 A / 12 A / 16 A / 20 A 7A input for 10 A string fuse** 8.4 A input for 12 A string fuse** 11.2 A input for 16 A string fuse** input for 20 A string fuse*** 13.3 A * optional ** reduction factor 0.7 *** reduction factor 0.665 SMA Solar Technology AG 3/13

Technical Data Input Data at 50 C Ambient Temperature PV array configuration Negative or positive grounded, insulated Maximum permissible DC voltage U DC 1 000 V Maximum permissible DC current I DC 312 A Number of measurement inputs 24 Maximum number of connections per 2 measurement input* Possible string fuses 10 A / 12 A / 16 A / 20 A 6.5 A input for 10 A string fuse** 7.8 A input for 12 A string fuse** 10.4 A input for 16 A string fuse** input for 20 A string fuse** 13.0 A * optional ** reduction factor 0.65 DC Main Connection Type of terminal Cage clamp Maximum connection cross-section 240 mm 2 / 300 mm 2 Suitable connection material Copper / aluminum Number of connections per DC output* 1 / 2 Cable entry via cable gland M40 Cable gland clamping zone 13 mm 32 mm * Sunny String Monitor SSM24 11 with bottom plate: connection of 1 cable per DC terminal possible. Sunny String Monitor SSM24 11 without bottom plate: connection of 2 cables per DC terminal possible. DC String Connection to MC4 Plug Connector Cable cross-section 6 mm 2 Maximum rated current DC String Connection to MC3 Plug Connector 30 A Cable cross-section 4 mm 2 Maximum rated current 20 A SMA Solar Technology AG 4/13

Technical Data DC String Connection to Plug Connector SUNCLIX Cable type PV1-F Cable cross-section 2.5 mm 2 6mm 2 Cable diameter 5 mm 8 mm Maximum rated current 40 A DC String Connection to Spring-Type Terminal Grip range 0.2 mm 2 6mm 2 Cable gland Cable support sleeve DC String Connection to Disconnection and Measurement Terminal Grounding Connection Connecting the communication * Maximum shield diameter: 8 mm M32 3 x 5 mm / 3 x 7 mm / 3 x 9 mm Type of terminal Spring terminal Maximum connection cross-section 0.2 mm 2 6mm 2 Cable entry via multiple cable gland M50 Grip range of multiple cable gland 5.0 mm 5.5 mm / 5.6 mm 6.0 mm / 6.1mm 7.0mm / 7.1mm 8.0mm / 8.1mm 9.0mm Type of terminal Cage Clamp Maximum connection cross-section 35 mm 2 Cable entry via cable gland M25 Cable gland clamping zone 7 mm 14 mm Measurement voltage supply 35 V DC 55V DC Type of terminal Spring terminal Maximum connection cross-section 0.08 mm 2 2.5mm 2 Cable entry via cable gland M25 Cable gland clamping zone 7 mm 14 mm Recommended cable type 4 mm x 2 mm x 0.5 mm Li2YCYv (TP) Number of provided contactable shield clamps* 2 SMA Solar Technology AG 5/13

Technical Data Remote triggering with shunt release (optional) Nominal voltage 220 V AC 240 V AC Extended operating range 30 % +10 % Nominal frequency 50 Hz / 60 Hz Power consumption 100 VA Remote triggering with undervoltage release (optional) Nominal voltage 220 V AC 240 V AC Extended operating range 15 % +10 % Nominal frequency 50 Hz / 60 Hz Power Consumption 3 VA Connection Remote Triggering (optional) Type of terminal Spring terminal Maximum connection cross-section 0.5 mm 2 6mm 2 Cable entry via cable gland M25 Cable gland clamping zone 7 mm 14 mm Feedback contact with remote triggering (optional) Nominal voltage Nominal current Format 250 V AC/DC 5 A AC / 0.15 A DC Changeover contact Connection feedback contact (optional) Type of terminal Spring terminal Maximum connection cross-section 0.25 mm 2 2.5mm 2 Cable entry via cable gland M25 Cable gland clamping zone 7 mm 14 mm Protection Rating and Ambient Conditions Protection rating * IP 54 Permissible ambient temperatures T AMB 25 C +50 C Relative air humidity 15 % 95 % Maximum altitude above sea level, AMSL 1 000 m * Per DIN EN 60529 SMA Solar Technology AG 6/13

Mounting Options and Dimensions Interfaces Communication Transmission rate Monitored overvoltage protectors type II String current measurement RS485 19 200 baud 3 Mounting Options and Dimensions The Sunny String Monitor SSM24 11 is suitable for both wall and plinth mounting. For both mounting options, a strain relief for the connecting cables is to be installed: Base mounting: strain relief using an internal cable support rail in the plinth. The scope of delivery includes the strain relief. Wall mounting: strain relief via an external cable support rail. The scope of delivery does not include the strain relief. SMA Solar Technology AG 7/13

Mounting Options and Dimensions Base mounting A B C Upper plinth panel Plinth filler or coarse gravel with a grain size of 4 mm 8 mm Fine gravel or sand with a grain size of 2 mm 4 mm Accumulation of Moisture The filled plinth area largely prevents accumulation of moisture in the Sunny String Monitor SSM24 11. Rising soil humidity is responsible for up to 90 % of condensation. SMA Solar Technology AG 8/13

Mounting location Wall mounting 4 Mounting location Select a mounting location for the Sunny String-Monitor SSM24-11 where it stands level and is protected against direct sunlight. The mounting location should be accessible for maintenance work. In the case of a rack-mounted PV generator, the Sunny String Monitor SSM24 11 can ideally be positioned directly behind the generator in the shadow. Here, make sure that no rain flows over the Sunny String Monitor SSM24 11 enclosure from the module surface. SMA Solar Technology AG 9/13

Electrical Connection 5 Electrical Connection Single and multi-strand copper and aluminum cables with round or sectoral cross-section can be connected to the DC main connection. The following table shows the different connection possibilities. Terminal Average for Copper Cable Connection terminal Number of conductors Round, single-strand Round, multi-strand Terminal Average Sectoral, single-strand * Sunny String Monitor SSM24 11 with bottom plate: connection of 1 cable per DC terminal possible. ** Sunny String Monitor SSM24 11 without bottom plate: connection of 2 cables per DC terminal possible. Sector, multi-strand maximum 240 mm 2 1* 25 mm 2 50 mm 2 25 mm 2 240 mm 2 50 mm 2 185 mm 2 35 mm 2 240 mm 2 2** 25 mm 2 50 mm 2 25 mm 2 120 mm 2 50 mm 2 120 mm 2 35 mm 2 120 mm 2 maximum 300 mm 2 1* - 150 mm 2 300 mm 2 150 mm 2 185 mm 2 150 mm 2 240 mm 2 2** 70 mm 2 70 mm 2 185 mm 2 95 mm 2 185 mm 2 95 mm 2 185 mm 2 Terminal Average for Aluminium Cable Connection terminal Number of conductors Round, single-strand Round, multi-strand Terminal average Sectoral, single-strand * Sunny String Monitor SSM24 11 with bottom plate: connection of 1 cable per DC terminal possible. **Sunny String Monitor SSM24 11 without bottom plate: connection of 2 cables per DC terminal possible. Sector, multi-strand maximum 240 mm 2 1* 25 mm 2 50 mm 2 25 mm 2 240 mm 2 50 mm 2 185 mm 2 95 mm 2 185 mm 2 2** 25 mm 2 50 mm 2 25 mm 2 120 mm 2 50 mm 2 120 mm 2 50 mm 2 95 mm 2 maximum 300 mm 2 1* - 150 mm 2 300 mm 2 150 mm 2 185 mm 2 150 mm 2 240 mm 2 2** 70 mm 2 70 mm 2 185 mm 2 95 mm 2 185 mm 2 95 mm 2 185 mm 2 SMA Solar Technology AG 10/13

Features Grip Range of Spring-type Terminals If bootlace ferrules are used on spring-type terminals of the "cage clamp" type, connection cables with the maximum permissible standard terminal cross-section may not be used. The next smaller cross-section must be selected. Measurement voltage supply Measurement voltage supply and interface connection are to be routed in a single cable. The corresponding cable type must contain eight wires and have a minimum cross-section of 0.5 mm 2. The cable shield must be connected to the according shield connections in the inverter and the Sunny String Monitor SSM24 11. Documentation Please follow all instructions contained in the Sunny String Monitor SSM24 11 documentation. 6 Features 6.1 Interior View Use the option code to select the features for the Sunny String Monitor SSM24 11. The following overview shows a Sunny String Monitor SSM24 11 with fuses in the positive and negative pole. The currents are measured in the positive pole. The standard DC switch is equipped with an optional remote triggering. SMA Solar Technology AG 11/13

Features 6.2 Remote Triggering for DC Switch (optional) The DC switch can be fitted with an auxiliary circuit breaker for remote triggering. The auxiliary tripping unit can be implemented as shunt trip or undervoltage release Like this, it is possible to disconnect the PV generator from the inverter via the DC switch in the Sunny String Monitor. The integrated feedback contact shows the current switching status. Remote Tripping with Shunt Release The shunt release is used to switch off the DC switch in an electrically controlled way. Operation of the shunt trip is only guaranteed at a voltage between 70 % and 110 % of the nominal voltage U N. If a voltage is present at the shunt trip, the DC switch is triggered. This is controlled via a make contact. In the event of wire breakage, loose connection, undervoltage or loss of voltage supply, the function of the shunt release is not guaranteed. We recommend operating the shunt release with an uninterrupted voltage supply. The activation time for safely activating the shunt trip is at least 3 seconds. SMA Solar Technology AG 12/13

Features Cable Requirements In order to achieve secure triggering, the minimum cross-sectional area of the connection cable must be determined. The cross-section to be chosen depends on the number of Sunny String Monitors that are connected, the cable length to the voltage supply and the cable lengths between the connected Sunny String-Monitors. The following diagram shows the relation between cable length, number of connected Sunny String-M o n i t o r s a n d c a b l e c r o s s - s e c t i o n. Number of DC switches Remote Tripping with Undervoltage Release The undervoltage release is used to switch off the DC switch in an electrically controlled way. The DC circuit breaker is tripped when there is no voltage at the undervoltage release, or if the voltage falls below 85 % of the nominal release voltage U N. After tripping, the circuit breaker can be switched back on when the voltage rises above 85 % of the nominal release voltage U N. Only if voltage is present at the undervoltage release, the DC switch can manually be switched on again. In order to avoid inadvertent tripping, an uninterrupted power supply is recommended. The undervoltage release is designed for continual operation. This is controlled via a break contact. The undervoltage release is the suitable triggering element for secure shutdowns or locks, for example emergency stop, because they shut off in case of disturbance. The minimum interruption time for secure tripping of the undervoltage release is 1 second. Cable Requirements For a safe operation we recommend a minimum cable cross-sectional area of 2.5 mm 2 at an overall cable length of 1 000 m. Selection of the Tripping Type Greatest distance between the Sunny String-Monitors or power supply and the first Sunny String-Monitor [m] Depending on the legal regulations at the installation site, the remote tripping can be required as a breakcontact function. Remote tripping with undervoltage release complies with this requirement. SMA Solar Technology AG 13/13