VL-9S PRODUCT SHEET. VL-9S Switch Registers (Mechanical Reed Switch)

Similar documents
Battery Operated Acre Counter User Manual SOFTWARE VERSION 6.0. Loup Electronics

MAZDA Application Purchase and Installation Guide

Geosignal. Datalogger XT 102 USB. Version User Manual

Please Read This Manual First! This MAP GIS Elite has been updated! NOT USED with External GPS!

LINE BUTTONS LCD SCREEN

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps

HOBO State Data Logger (UX90-001x) Manual

HOBO State Data Logger (UX90-001x) Manual

Ardusat Space Kits in the Classroom

MOD. KBC HEAD KONTAX BATCH CONTROLLER

PoE Digital Code Blue & Elapsed Timer Operation Guide

F1 Goose Installation Instructions

Hydrological Services CMC20A OPERATING MANUAL CMC20A. Current Meter Counter

WiFi dashcam Roadview 16GB

Quick Installation Guide for Field Installers

Introduction 3. Features.5. Dimension Chart...6. Connection.7. Hardware Setting.. 9. GP-58R Battery Function Setting..15 Coupon & Receipt...

Peafowl Installation Instructions (Goose-It / F1-Goose Replacement)

FAC-R Frequency to Analog Converter Installation, Operating & Maintenance Manual

Heavy Duty Hot Wire CFM Thermo-Anemometer

Model No Universal Input Indicator Start-up Guide

User Manual Halo Home App. Add, Edit and Remove Devices

Mini Mini GlobiLab Software Quick Start Guide

Switch Board for communicator Alarm

Xero A1/A1i. Owner s Manual

ETL COUNTER CONTROLLER VERSION 1.0

DIGITAL VIDEO RECORDER INSTRUCTION MANUAL VER J1.2

Installers & User guide Smart Mortise.

I. PANEL DESCRIPTION... 1

Installers & User guide Smart Mortise.

SVM F4. Calculator. Manual

Creating a Brochure in Publisher

Aspera R7. User Manual

How to install and use the "Turbine Trend" ipad App

TITAN S8. Portable Data Acquisition Logger. Product User Guide

Type Approval Certificate

Instructions manual. Thermostat User Manual

Simple data sample and store to USB with the SDM3000 series of DMMs

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.

DAF4207SD USER S MANUAL

Programming and Installation Manual

Quick Start Guide for Using TDS NOMAD GPS Equipment (For Team Leaders) Initial Unit Check

ProntoPro Intelligent Remote Control. User Guide

Table of Contents. Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4

TopGuard Online Help PATROL AND PATROL PLUS

Operators Manual for the TELXON PTC 610 and PTC 510 Order Entry System ROM Version 1.3

Automatic Operation: This is the simplest and quickest way to capture a signal, knowing little about what you are measuring.

Innovative Electronics for a Changing World INDEX

ipcam-wo Wireless Outdoor

Trident & Trident X2 PD765

explona dakar 2007 User manual

DS100 / DS100 LDC MANUAL

Schrole Cover Manual Table of Contents

Quick Start Guide for Using TDS NOMAD GPS Equipment (For Team Leaders) Initial Unit Check

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

Quick Start. What s in the Box. a - AirBand wireless Bluetooth stereo headset b - USB charging cable c - AC power adapter

ECLIPSE. Online and Downloadable Product Manuals and Quick Start Guides are available at

Mini Document & Photo Scanner. i-convert

Manual URC 4689 UK Apr05.fm Seite 1 Montag, 11. April :00 12

The IC can be used in new installations or as a replacement for an existing sprinkler control system.

Aeotec Multisensor Gen5 has been crafted to power connected lighting using Z-Wave Plus. It is powered by Aeotec s Gen5 technology.

M2110F SMART FLOW GAUGE OPERATING INSTRUCTIONS

TNP Digital Torque Meter Operation Manual

eforce 150 Keyless Entry Owner s manual & User s guide For Model 3090

B2800 FLOW MONITOR. - For Liquid Meters - PROGRAMMING & INSTALLATION MANUAL Simplified Version

MyTeleMed iphone User Guide

GSM Communicator GJD710 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START THE INSTALLATION

SECTION IIB DIAGNOSTIC MODES FOR 95Re LCD UNITS ONLY

PoE Digital Code Blue & Elapsed Timer Operation Guide

PURPOSE AND BACKGROUND

umapps Using umapps 12/5/2016 Brought to you by: umtech & The Center for Teaching & Learning

Android (A7-40) Y5 Classrooms: User Guide

M-Bus-Logger Data Logger

Show Designer 1. Software Revision 3.11

Series B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

6222 Two Door Module Technical Operations Manual

D-100 FLOW DISPLAY MODBUS Network Interface Installation Guide

System Controller Programming Manual

Outlook Web Access. In the next step, enter your address and password to gain access to your Outlook Web Access account.

= 3 + (5*4) + (1/2)*(4/2)^2.

What are Non-Catalog Orders?

FTK5 PROXIMITY KEYPAD

Getting Started with Nokē Pro

STING II Digital Video Recorder/Player. User s Guide

IS-Dev Kit-8 User Manual

MR52 READER INTERFACE

AE14-503J SERIES PRODUCTION DISPLAY SYSTEM

LON-module for MULTICAL 601

Biometric finger print entry system.

3. Collecting Data with Collector

Using the Android teach-pad

Table of Contents. Introduction 2 1. Intelligent Remote Control 2 2. Charging the Remote Control 3

LoadMaxx. User Guide. Phone and Tablet App. for Android and ios. Air-Weigh Customer Support: PN R0

EAGLE-200. Intelligent Control Gateway. User Manual

OmniCounter Pro Infrared People Counter. People Counter. Introduction. Table of Contents. Model: OmniCounter Pro

3465 Diablo Avenue, Hayward, CA U.S.A Fax:

Quick Start Reference Guide Series 9.x and 10.x Software

INTEGRATION OVERVIEW:

Open Microsoft Word: click the Start button, click Programs> Microsoft Office> Microsoft Office Word 2007.

AuraBox 2.0 Instruction Manual

Transcription:

VL-9S PRODUCT SHEET VL-9S Switch Registers (Mechanical Reed Switch) The VL-9S connects to registers providing a mechanical switch closure (such as a reed switch), for incremental pulse counting. Installing the VL-9S on a Switch-Type Register (Mechanical Reed Switch) 1. Connect the VL-9S to the switch-type register (polarity does not matter on this type of register). 2. To enter PROGRAMMING MODE, tap the display to turn it on, then when it is displaying either a meter reading or the message "PROGRMNG REQUIRED", tap the following password into the display: 4 taps 5 taps 2 taps 3 taps Wait after each tap until one of the small comma symbols (dots) near the top left corner of each display digit lights up acknowledging your tap, then tap again. Keep tapping until the number of dots above the digits corresponds to the number of taps in the current password digit. For example, if 3 password taps

have been received, then 3 digits will have a small dot lit above them. For example, the following shows 3 dots above the digits, so 3 of 4 password taps have been acknowledged so far:,,, 3. After all the taps have been acknowledged for the first password digit, wait a few seconds for the dots to disappear, then start tapping in the next digit. Repeat until all 4 of the password digits stated above have been tapped in. The following shows correct entry of all 4 password digits. Displayed digits are all zero for this illustration. Either the words "PROGRMNG" or "REQUIRED" may displayed instead of numbers (if the VL9s has never been programmed yet): 4 acknowledged taps:,,,, 5 acknowledged,,,,, taps: 2 acknowledged,, taps:,,,

3 acknowledged taps: 4. After all of the password digits have been tapped in successfully, the display will show the message "PROGRAM MODE". If a mistake is made, wait until the display shows the version number or blanks out before trying again starting with step 2 above. 5. The display will blink and prompt for the number of digits of the register. The number of register digits to be entered is the number of moving odometer digits (excluding any "painted on" digits). For example, the register below has 6 moving odometer digits (000012) and one painted-on zero at right (which is not counted). Therefore the number of digits = 6, and the reading is "000012". To change the number of digits displayed tap on the display while "DIGITS" is flashing. The number shown before the word "DIGITS" will increase with each tap until the number 8, then the next tap it cycles back to 4 and again increases once with each tap. Once the desired number of digits is showing, do nothing for at least 4 seconds until the display stops blinking to accept that value for "number of digits". For example, if 6 digits are desired, tap until the display shows "6 DIGITS" and then stop tapping (if it already says "6 DIGITS" then don't tap, just wait until prompt stops blinking). 6. At the start of meter reading programming a digit will appear near the left side. This is the first (left-most) digit of the meter to be programmed in. Tap to

increment this digit until it equals the left-most odometer digit of the register (if the left-most meter digit is already correct no taps need to be entered for it). To correct a mistake keep tapping until the digit rolls over from 9 back to 0 and then counts upward again to the desired digit. The following shows the first digit set to "1" matching the picture above on a 6-digit meter. 0 7. After 4 seconds of no tapping, the next digit to the right will illuminate. Tap until this digit matches the corresponding meter digit (second from left), shown below matching the second digit of the register pictured above. Then wait at least 4 seconds to move to the next digit. 0 0 8. Continue tapping in digits to match each of the register's odometer digits. 9. Next, a decimal point will show up. If the decimal point is already in the desired position, then do not tap. Otherwise tap the display to move the decimal point 1 digit to the left for each tap (wait until the decimal point moves before tapping again). After moving all the way to the left, the decimal point cycles back to the far right at next tap. 0 0 0 0. 1 2 Tap until the decimal point is to the right of the least significant billing digit. If a mistake is made, keep tapping to until the decimal point cycles back to the desired position. For example, for the meter displayed above, if the utility wishes to bill in only the 4 most significant digits, the decimal point should be positioned to the right of the 4th digit from the left as shown below: 0 0 0 0. 1 2 The billing digits above read "0000" since they are to the left of the decimal point. 10. Wait until the display blanks (at least 4 seconds of no tapping).

After each display session the VL-9S software version displays briefly before the display turns off. To turn the display on again tap the faceplate either during the version display or after it turns off. Tapping the display while the reading is active begins the password entry procedure again (don't do that unless reprogramming is desired). Reading the VL9s 1. Tap the circular disk on the front of the display. 2. Write down the digits shown which are to the left of the decimal point. This is the meter reading for billing purposes. VL9s Specifications (for Mechanical/Reed Switch-Type Registers) Operating temperature: -30 to +80 ºC for display active, down to -40 ºC for display inactive Internal battery life: 10 years minimum Battery replacement capability: optional if external wires are provided Maximum cable length: 5000 feet using Belden 8451 or (General Cable C0742A) Minimum time between switch closures: 1 sec Minimum duration of valid switch closure: 0.3 sec Number of displayed digits: User programmable: 4, 5, 6, 7, or 8 (to match register) TAMPER function: not implemented