Probing High-speed Signals with the Agilent Series of Wide-bandwidth Sampling Oscilloscopes

Similar documents
N2753A and N2754A Windows XP to Windows 7 Upgrade Kits. For Infiniium 9000, 90000, and X-Series Oscilloscopes

W2630 Series DDR2 BGA Probes for Logic Analyzers and Oscilloscopes

Agilent U2941A Parametric Test Fixture

E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software for Infiniium Oscilloscopes

Agilent E5072A ENA Series Network Analyzer

W3630A Series DDR3 BGA Probes for Logic Analyzers and Oscilloscopes

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium Series Oscilloscopes

Agilent E4982A LCR Meter

Agilent InfiniiMax III probing system

Using the U8030 Series Power Supply Output Sequencing Feature

Agilent 34450A 5.5 Digit Bench Digital Multimeter. Turbo charge your measurements with one of the fastest throughput digital multimeter in its class

MIPI D-PHY Multilane Protocol Triggering and Decode

Agilent N1918A Power Analysis Manager

Agilent Technologies U7243A USB 3.0 Superspeed Electrical Performance Validation and Compliance Software for the Infiniium Series Oscilloscopes

Agilent Technologies B4656A FPGA Dynamic Probe for Altera

I 2 C and SPI Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Agilent B4655A FPGA Dynamic Probe for Xilinx

N6468A SFP+ Electrical Performance Validation and Conformance Software

N2870A Series Passive Probes and Accessories

Agilent InfiniiMax III probing system

N2870A Series Passive Probes and Accessories

N5435A Infiniium Server-Based License for Infiniium Oscilloscopes

Agilent U7233A DDR1 Compliance Test Application with LPDDR and mobile-ddr Support for Infiniium Series Oscilloscopes. Data Sheet

Keysight N8841A CAUI-4 Electrical Performance Validation and Conformance Software

Agilent U2600A Series USB Modular Isolated Digital I/O Devices. Data Sheet

Keysight N2753A and N2754A Windows XP to Windows 7 Upgrade Kits For Infiniium 9000, 90000, and X-Series Oscilloscopes. Configuration Guide

MXG X-Series Signal Generators N5181B Analog & N5182B Vector. Configuration Guide

Infiniium MSO8000, MSO9000A and MSO 9000 H-Series N5397A FPGA Dynamic Probe for Xilinx

Agilent 66000A 1200 W DC Modular Power System, GPIB

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Keysight E5063A ENA Series Network Analyzer

Agilent 16962A 2 GHz State, 2/4/8 GHz Timing Logic Analyzer Module

6640A Series Single-Output, 200 W DC Power Supplies, GPIB

VISA, SICL, VISA COM,

Keysight W2630 Series DDR2 BGA Probes for Logic Analyzers and Oscilloscopes. Data Sheet

Agilent U1177A IR-to-Bluetooth Adapter

Keysight Technologies

Keysight N8840A USB Power Delivery Electrical and Protocol Compliance Test Software

Agilent N4880A Reference Clock Multiplier

Keysight DSOX4USBSQ and DSOX6USBSQ USB 2.0 Signal Quality Test Option for 4000 and 6000 X-Series. Data Sheet

Keysight N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope. Data Sheet

Agilent Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Agilent E5061B Network Analyzer. Configuration Guide

Keysight Technologies N5394A DVI Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies I 2 C and SPI Protocol Triggering and Decode

Keysight Technologies N5392B Energy Eficient Ethernet Electrical Performance Validation/ Conformance Software For Ininiium Oscilloscopes

Keysight Technologies W3630A Series DDR3 BGA Probes for Logic Analyzers and Oscilloscopes. Data Sheet

Keysight Technologies EPM and EPM-P Series Power Meters E-Series Power Sensors. Configuration Guide

EXG X-Series Signal Generators N5171B Analog & N5172B Vector

Agilent Specifying and Buying a Bench Power Supply. Application Note

Solutions for Streamline Field Test with Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent N5431A XAUI Electrical Validation Application for Infiniium Oscilloscopes and Digital Signal Analyzers

Accessories for the Agilent B2900A Series of Precision Instruments

Keysight Technologies DCA Probes & Accessories. Technical Overview

Keysight Technologies N8825A/B Infiniium 10BASE-T / 100BASE-TX Ethernet Decoder. Data Sheet

I 2 C and SPI Protocol Triggering and Decode for Infiniium 8000 and Series Oscilloscopes

Agilent L4450A 64-Bit Digital I/O with Memory and Counter

Agilent U7231B DDR3 and LPDDR3 Compliance Test Application for Infiniium Series Oscilloscopes. Data Sheet

PCI Express Protocol Triggering and Decode for Infiniium 9000 Series Oscilloscopes

Keysight Technologies DSOX4USBSQ USB 2.0 Signal Quality Test Option for 4000 X-Series. Data Sheet

Keysight Technologies N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes. Data Sheet

Keysight Technologies Methods for Characterizing and Tuning DC Inrush Current. Application Brief

Agilent Technologies Infiniium MSO8000 and MSO9000 Series N5397A FPGA Dynamic Probe for Xilinx

Keysight Technologies InfiniiMax III/III+ Probing System

Keysight Technologies UXG Agile Signal Generator, Modified Version N5191A

Agilent RDX Test Solutions for DigRF

Agilent M9036A PXIe Embedded Controller

Keysight Technologies GSM/W-CDMA SMS Testing with Wireless Test Managers (WTMs) Application Note

Agilent Modern Connectivity Using USB and LAN I/O Converters

Keysight Technologies RS232/UART Protocol Triggering and Decode for Infiniium Series Oscilloscopes. Data Sheet

Keysight B2980A Series Femto/Picoammeter Electrometer/High Resistance Meter

Overview. Applications

Agilent Technologies InfiniiVision MSO N5406A FPGA Dynamic Probe for Xilinx

Keysight Technologies N6472A IEEE802.3bs/cd Compliance Application

Agilent Noise Source Calibration Using the Agilent N8975A Noise Figure Analyzer and the N2002A Noise Source Test Set. Product Note

I 2 S Triggering and Hardware-based Decode (Option SND) for Agilent InfiniiVision Oscilloscopes

Agilent Oscilloscope Probes and Accessories

EZJIT Plus Jitter Analysis Software for Infiniium Oscilloscopes

Keysight Technologies 8163B Lightwave Multimeter 8164B Lightwave Measurement System 8166B Lightwave Multichannel System.

Keysight Technologies DDR4 Functional/Protocol Debug and Analysis Reference Solution. Configuration Guide

CAN Eye-diagram Mask Testing

Keysight Technologies E4982A LCR Meter

Keysight N5435A Infiniium Server-Based License for Infiniium Oscilloscopes

Keysight Technologies N8806A User Defined Function for Editing and Execution for Infiniium Oscilloscopes. Data Sheet

Keysight N7018A Type-C Test Controller. Data Sheet

Keysight E6962A Automotive Ethernet Rx Compliance Solution

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Keysight Technologies N5392A Ethernet Electrical Performance Validation and Conformance Software for Infiniium Oscilloscopes

Agilent N1810/1 /2 Coaxial Switches

N7624B Signal Studio for LTE Technical Overview

Keysight Technologies W3630A Series DDR3 BGA Probes for Logic Analyzers and Oscilloscopes. Data Sheet

N5393C PCI Express 3.0 (Gen3) Software for Infiniium Oscilloscopes

N4010A Wireless Connectivity Test Set and N4011A MIMO/ Multi-port Adapter

Keysight E6963A Automotive Ethernet Link Segment Compliance Solution

Agilent Handheld Test Tools

Keysight N2870A Series Passive Probes and Accessories. Data Sheet

Technical Overview. Key Features

Keysight L4445A Microwave Switch/Attenuator Driver. Data Sheet

Testplan Development on CVI Labwindows with TS-5400 PXI Series

Transcription:

Probing High-speed Signals with the Agilent 86100 Series of Wide-bandwidth Sampling Oscilloscopes Product Note 86100-6 The high bandwidth and low noise of equivalent-time sampling oscilloscopes provide precise displays of high-speed signals. Historically, if the signal could not be routed to the oscilloscope through a high-quality cable, thus requiring the use of a probe, accurate measurements became difficult to achieve. Three important measurement accessories help make probe based measurements both simple and accurate for the Agilent 86100 Wide Bandwidth Oscilloscope: Agilent 113X, 115X, and 116X series of high performance probes with up to 13 GHz of bandwidth Agilent N1022B probe adapter Agilent 83496A/B clock recovery module

Probes Agilent offers a wide variety of probes with the bandwidth and connectivity required for high-speed waveform analysis. These include differential and single-ended probes with solder in, socketed, SMA, and browsing probe heads offering variable spacing probe tips for today s high-density IC s and circuit boards. Typical bandwidths are available from 1.5 to 13 GHz (9/05). All probes have a flat frequency response over the entire probe bandwidth to eliminate distortion and frequency-dependent loading effects. Connecting the probe to the oscilloscope The precision 3.5 mm connector used for the electrical channels of several 86100 plug-in modules is not directly compatible with the standard probe interface of Agilent real-time sampling oscilloscopes. This problem is solved with the N1022B Probe Adapter. The N1022B Probe Adapter provides power, calibration, and a highintegrity signal path between the probe and the 861XX series plug-in module. The interface of the probe amplifier section attaches to one side of the adapter. The other side of the probe adapter is an instrumentation grade 3.5 mm connector that attaches to the bulkhead male 3.5 mm connector of the electrical channel of the oscilloscope plug-in module. For power and identification, an interface cable from the probe adapter attaches to the probe power port of the oscilloscope plug-in. Figure 1: infiniimax probes N1022B Probe amplifier Figure 2: Connecting a probe through the N1022B adapter 2

The N1022B is directly compatible with the following modules: 86101A 86103A and B 86106A 83481A 83485A 83487A 54753A 86102A and U 86105A 86112A 83483A 83486A 54751A 54754A The 86100 oscilloscope mainframe has built-in calibration routines (except as noted above) to compensate for probe attenuation and offset to allow a direct display of the actual signal levels found at the probe tip. Very high frequency and small pitch probes such as the N5381A 12 GHz solder-in probe head are difficult to connect to the 86100 BNC calibration connector. The E2655B Deskew and Performance Verification fixture is recommended. The following plug-in modules have 2.4 mm compatible connectors. The 85130-60010 2.4 mm (f) to 3.5 mm bulkhead adapter is required in addition to the N1022B: 86106A 86109A 86116A 86117A 83484A 86106B 86109B 86116B 86118A (For non-oscilloscope applications, a type N (m) to 3.5 mm bulkhead adapter (N1022-60014) is available. There is also a 3.5 mm (f) to 3.5 mm bulkhead adapter (85052-60034)). The following plug-in modules do not have built-in probe power supplies. The Agilent 1143 power supply is used to provide probe power through the N1022B. (In this configuration an automatic gain and offset calibration is not available. A manual gain calibration can be performed to account for probe attenuation and signal splitting). The 01143-61602 probe power extension cable may be useful to allow the 1143 power supply to be located over 1 meter away from the oscilloscope or other instrument. Figure 3: The E2655B Deskew and Performance Verification fixture allows for easy probe calibration with the 86100 DCA 86105B 86105C 86116B 86117A 86118A 3

Triggering the oscilloscope with a clock extracted from the probed signal Sampling oscilloscopes are different from real-time oscilloscopes in that they require a triggering signal other than the test signal itself. The triggering signal is often a clock that is synchronous to the signal under test. In a probing scenario, a separate system clock for triggering may not be present. When the necessary synchronous trigger is not available, one solution is to derive a clock from the data being measured. This process is performed with the 83496A/B clock recovery module. The N1022B and appropriate probe are connected to the 83496A/B input port where the signal is evenly split within the module (see Figure 4). Half is used for clock extraction; the other half is routed to the 83496A/B front panel and then connected to the input channel of the adjacent plug-in module. The 83496A/B will derive a clock from the data. The recovered clock signal rate is divided by eight and routed internally in the 86100 mainframe. The full rate clock or user selected rate divided clock is available at the 83496A/B front panel and can be useful as a trigger for eye diagram analysis when data pattern lengths are multiples of two. (A divided trigger with an even divisor yields an incomplete eye, see Product Note 86100-5). Above 7.1 Gb/s, the front panel recovered clock has a minimum divide ratio of two. The 83496A/B option 100 requires at least 150 mvpp at its input port to accurately perform clock extraction. If a 10:1 probe is used (such as the 1134A), the signal level at the probe tip must be greater than 1.5 Vpp. If a 3.45:1 probe is used (such as the 1169A), the signal level at the probe tip must be greater than 500 mvpp. Note however, that a proper probe calibration will compensate for both the probe attenuation and signal splitting within the 83496A/B and provide an accurate display of signal levels on the oscilloscope screen. (83496A/B option 101, without internal splitters, requires half the input signal of 83496A/B option 100 for clock extraction. Any signal splitting outside the module must be considered when determining system limits.) The 83496A/B clock recovery module can derive a clock from NRZ signals with rates as low as 50 MB/s, as high as 13.5 Gb/s, and any rate between, providing the ultimate in flexibility and value. (As of 12/06 the data rate must be entered into the 83496A/B to allow it to properly synchronize to the signal being probed). As low as 300 femtoseconds rms, the residual jitter of the output clock is virtually negligible, allowing accurate measurements of very low levels of signal jitter. The 83496A/B can be configured with a tunable loop bandwidth. This critical feature allows the module to be operated as a golden PLL with the optimal loop bandwidth for whatever standard/data rate is being tested. Loop bandwidth will con- trol what spectrum of jitter is observed and what is tracked out from eye-mask and jitter tests. For example, low frequency jitter can be removed, which is usually of low importance since system receivers easily tolerate it. Testing with an optimal loop bandwidth assures that good parts do not appear to be bad, and bad parts do not appear to be good. For more information on the use of clock recovery loop bandwidth, refer to product note 86100-5 Triggering Wide-bandwidth Sampling Oscilloscopes for Accurate Displays of High-speed Digital Communications Waveforms. The following configurations for the 83496A/B are available: Option 100: Electrical differential or single-ended clock recovery 50 Mb/s to 7.1 Gb/s. The input signal is internally split and ~ 50% routed back out to the measurement channel of the adjacent plug-in module. When measuring differential signals, the most convenient technique is to use a differential probe tip, rather than provide two input signals to the 83496A/B. The probe provides a single-ended signal to the 83496/861XX channel representative of the difference between the signals at the two probe tips. The 83496A/B Option 101 electrical/optical clock recovery module is not recommended for probing as it does not have an internal signal divider. It can be used, but requires an external power divider that precludes the installation of the N1022B on the front of the clock recovery module. A complicated adapter scheme is required. See below. Special Option 101-H05: This special option version of the electrical/optical clock recovery module integrates the signal splitting within the module. Use for electrical signals is similar to Option 100. No special adapters other than the N1022B are required. Option 200: Increase operating range to 50 Mb/s to 13.5 Gb/s. Available for either Option 100 or Option 101 configurations. When measuring clocks, rates from 25 MHz to 7.75 GHz are allowed. Option 300: Add golden PLL (tunable loop bandwidth capability). Loop bandwidth is tunable from 30 KHz to over 10 MHz. (Without Option 300, the loop bandwidth can be configured at two discrete settings, dependent upon data rate). Option 200 and 300 can also be added at a later date. The module must be returned to an Agilent service center for the upgrade. 4

Probe calibration procedures The 86100 DCA has a built-in calibration process to compensate for probe attenuation and offsets. The probe calibration is achieved by attaching the probe tip to a known DC signal that is available from the oscilloscope mainframe. The process is Calibration/All calibrations/ch X Probe compensation (for the channel the 83496A/B output is routed to). For probe compensation with plug-in modules that do not include a probe supply outlet (86105B, 86105C, 86117A, 86118A) the calibration procedure is similar. However, if there is a voltage offset, it must be compensated for manually (Setup/Channels/ Channel X/Advanced with the attenuation factor adjusted to account for signal loss in splitting and/or probe voltage division). 83496A 861XX N1022B Data in Data in Data out Data out Probe Figure 4: Connector scheme using the 83496A/B and N1022B 5

Probing configuration when using the optical/electrical configuration of the 83496A/B (Option 101) The primary usage of the 83496A/B Option 101 is for extracting clocks from optical signals. However, electrical inputs are provided to derive a clock from an electrical signal. Unlike 83496A/B Option 100 or special Option 101-H05, there are no internal dividers to tap the electrical signal and pass it to a measurement channel. If an electrical signal is to provide a trigger and be simultaneously observed, it must be divided before entering the 83496A/B. In a probing scenario, the chain of adapters required to connect a probe and probe adapter becomes complex as shown in the following sketch. Parts needed are: N1022B, probe adapter N1022-60014, adapter Type-N male to 3.5 NMD male 11636A, DC-18 GHz power divider, Type-N, 50 ohm 85054-60030, adapter: 3.5 mm female, Type-N male 1250-1745, adapter: 3.5 mm female, Type-N female 01143-61603, probe power extension cable 1143A probe power supply (optional) Probe power supply InfiniMax probe amplifier Probe power extension cable Differential browser probe head Probe adapter N1022B Male-to-male adapter (N to 3.5 NMD) N1022B-60014 11636A 1250-1745 Wrench spanner 85054-60030 Adapting and splitting signals for probing and clock extraction with the 83496A/B option 101 6

www.agilent.com www.agilent.com/find/dca Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.axiestandard.org AdvancedT- CA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent s measurement expertise and product breadth, combined with channel partner convenience. Agilent Advantage Services is committed to your success throughout your equipment s lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world. www.agilent.com/find/advantageservices www.agilent.com/quality For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894 4414 Brazil (11) 4197 3500 Mexico 01800 5064 800 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 131 452 0200 For other unlisted countries: www.agilent.com/find/contactus Revised: June 8, 2011 Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2011 Published in USA, July 28, 2011 5989-3854EN