SCADAPack 4102 Modbus multivariable transmitter
1 The SCADAPack 4102 Modbus Multivariable Transmitter is the flagship of our Ethernet transmitter product line, offering precise measurement of process pressure, differential pressure and temperature. As a fully digital transmitter, the product offers a built-in choice of Modbus protocol over serial and/or Ethernet communications, along with an optional PID controller and analog output. With this choice, the 4102 can be used in a wide variety of installations including low power transmitters in remote locations or as an addressed device offering control and measurement in an extended Ethernet network.
Specifications 2 Features Optional Analog Output Optional PID Controller LCD Interface 1 Communications Serial Port Serial Protocol Ethernet Port 2 Ethernet Protocols 2 Accuracy and Stability Differential & Absolute Pressure Accuracy Temperature Accuracy Stability Static Pressure Effect Ambient Temperature Effect Physical Specifications Power Mass Environmental Certifications SCADAPack 4102 0-20mA, 12 bit, sinking Fully configurable control of analog output relative to any measured variable Two button control, 2-line interface with 13 characters RS232/485 configurable, 1200 to 38400 baud Modbus RTU 10BaseT, terminal block connection Modbus/UDP, Modbus RTU in UDP ±0.05% of span (for spans >= 10% of URL) ±(0.005)x(URL / Span) % of Span (spans <10% URL) 3 ±0.28 C (±0.5 F) (not including RTD uncertainties) <±0.05% of URL per year over 5 years The zero and span shift for a 0.7MPa (100psi) static pressure change is: ZERO Shift ±0.004% of URL, SPAN Shift ±0.01% of reading Total effect for a 28 C (55 F) change for absolute and differential pressure is: Digital Output: ±(0.03%URL + 0.06% Span) 9 to 30 VDC. 225mW with LAN (60mW with Serial communications) 3.5kg (7.8lb) without process connectors 5% RH to 95%, non-condensing, 40 C ( 40 F) to 70 C (158 F) ccsaus Explosion proof. Class I, Div. 1 Groups B, C and D Hazardous Locations ccsaus Class I, Div. 2 Groups A, B, C and D Hazardous Locations Temperature code T5 at maximum ambient, 70 C Provides non-incendive field circuits for RTD CSA certified to the following standards: CSA Std. C22.2 No. 213-M1987 - Class I, Division 2 Hazardous Locations CSA Std. C22.2 - No. 142-M1987 - Control Equipment UL Std. No. 1604 - Class I and II, Division 2; Class III Hazardous (Classified) Locations UL Std No. 916 - Energy Management Equipment ATEX: LCIE 07 ATEX 6058 Ex d IIC T6; -50 C Ta 70 C per IEC 60079-1, protection type d (Flameproof) IECEx: CSA 05.0011 IECEx Ex d IIC T6; -50 C Ta 70 C per IEC 60079-1, protection type d (Flameproof) 1 Button control when setup for calibration through a SCADAPack Smart RTU using Realflo software 2 Available without a disabled Ethernet port 3 Accuracy stated includes the effects of Linearity, Hysteresis, and Repeatability Disclaimer: Schneider Electric reserves the right to change product specifications. For more information visit www.schneider-electric.com.
Model 3 TBUT4102E2A101U00N represents a sample code for a 4102 with Ethernet Model Select: Product Description TBUT4102 Modbus Multivariable Transmitter Select: Output Signal M Digital - Modbus Protocol, Jumper selectable RS232 or RS485, de-pluggable screw-type terminal block A Digital - Modbus Protocol, Jumper selectable RS232 or RS485, de-pluggable screw-type terminal block, 1 Analog Output E Digital - (1) RS485/232 with Modbus Protocol, (1) 10 BaseT Ethernet with Modbus/UDP protocol, 1 Analog Output Cover Sensor Material Sensor Fill Fluid Bolts 2 316 SS 316 SS Silicone CS-B7 Select: Differential & Absolute Pressure Span Limit Differential Pressure Absolute Pressure (Field Configurable for Gauge) Standard Sensor (Horizontal process connections with vertical mounting) A 0.5 to 30 inh2o (0.12 to 7.5 kpa) 1 to 100 psi (0.007 to 0.7 MPa) B 2 to 200 inh2o (0.50 to 50 kpa) 3 to 300 psi (0.021 to 2.1 MPa) C 10 to 840 inh2o (2.5 to 210 kpa) 3 to 300 psi (0.021 to 2.1 MPa) D 2 to 200 inh2o (0.50 to 50 kpa) 30 to 1500 psi (0.21 to 10 MPa) F 3 to 300 inh2o (0.75 to 75 kpa) 30 to 1500 psi (0.21 to 10 MPa) E 10 to 840 inh2o (2.5 to 210 kpa) 30 to 1500 psi (0.21 to 10 MPa) J 2 to 200 inh2o (0.50 to 50 kpa) 30 to 3000 psi (0.21 to 21 MPa) K 3 to 300 inh2o (0.75 to 75 kpa) 30 to 3000 psi (0.21 to 21 MPa) L 10 to 840 inh2o (2.5 to 210 kpa) 30 to 3000 psi (0.21 to 21 MPa) G 2 to 200 inh2o (0.50 to 50 kpa) 30 to 5300 psi (0.21 to 37 MPa) H 3 to 300 inh2o (0.75 to 75 kpa) 30 to 5300 psi (0.21 to 37 MPa) N 10 to 840 inh2o (2.5 to 210 kpa) 30 to 5300 psi (0.21 to 37 MPa) Low Profile Sensor (Vertical process connections with vertical mounting) U 0.5 to 30 inh2o (0.12 to 7.5 kpa) 1 to 100 psi (0.007 to 0.7 MPa) V 2 to 200 inh2o (0.50 to 50 kpa) 3 to 300 psi (0.021 to 2.1 MPa) W 10 to 840 inh2o (2.5 to 210 kpa) 3 to 300 psi (0.021 to 2.1 MPa) X 2 to 200 inh2o (0.50 to 50 kpa) 30 to 1500 psi (0.21 to 10 MPa) Z 3 to 300 inh2o (0.75 to 75 kpa) 30 to 1500 psi (0.21 to 10 MPa) Y 10 to 840 inh2o (2.5 to 210 kpa) 30 to 1500 psi (0.21 to 10 MPa) M 2 to 200 inh2o (0.50 to 50 kpa) 30 to 3000 psi (0.21 to 21 MPa) P 3 to 300 inh2o (0.75 to 75 kpa) 30 to 3000 psi (0.21 to 21 MPa) R 10 to 840 inh2o (2.5 to 210 kpa) 30 to 3000 psi (0.21 to 21 MPa) Q 2 to 200 inh2o (0.50 to 50 kpa) 30 to 5300 psi (0.21 to 37 MPa) S 3 to 300 inh2o (0.75 to 75 kpa) 30 to 5300 psi (0.21 to 37 MPa) T 10 to 840 inh2o (2.5 to 210 kpa) 30 to 5300 psi (0.21 to 37 MPa) Select: Temperature Measurement 1 Terminal Blocks for Connection of External 100 Ohm Platinum RTD (DIN/IEC) Select: Connector Type 0 1/4 NPT, Threaded in Cover, with red plastic conduit cap 1 1/2 NPT, Flange Adapter c/w CS Grade B7 bolts Select: Transmitter Housing Material Conduit Entry Sizes 1 Epoxy-coated Aluminium (2) 1/2-14NPT 3 316 SS (2) 1/2-14NPT Model s continue on the next page
Model 4 TBUT4102E2A101U00N represents a sample code for a 4102 with Ethernet Model Select: Approvals U CSA Class 1 - Div 1 (Groups B,C,D) & Div 2 (Groups A,B,C,D). Approved - Hazardous Locations X IECEx to Exd IIC T6 and ATEX to EEx d IIC T6 Future Option 00 None Select: Options Select Option group code required: N None A Digital Indicator (Black Epoxy) B Digital Indicator (Black Epoxy), Stainless Steel Cover Bolts E Digital Indicator (Stainless Steel) F Digital Indicator (Stainless Steel), Stainless Steel Cover Bolts J Stainless Steel Cover Bolts
Dimensions 5 mm in 84 3.3 connection Conduit connection, both sides (Note 1) Optional custody transfer lock (seal) both ends connector (Note 2) Blind flange 97 3.8 connection Allow 50 mm (2 in) clearance for cover removal, both ends. (Note5) Vent screw Plug Note 6 137 5.4 64 2.5 124 4.9 112 4.4 33 1.3 No process connection (this end) 64 2.5 Transmitter with Mounting Options M1 or M2 Extended cover used with optional LCD indicator FIELD TERMINALS 208 8.2 External earth (ground) L-H Indicator low-high pressure side L-H External earth (ground) For surface mounting replace U-Bold with two 0.375 in diameter bolts of sufficient length to pass through bracket and surface. Optional side vent/drain (Note 3) connector (Note 2) Note 4 227 5.0 41.3 1.626 99 3.9 Optional 4203 mounting bracket Telemetry & Remote SCADA Solutions www.schneider-electric.com Vertical DN 50 or 2 in pipe shown. Rotate U-Bolt 90º for mounting to horizontal pipe. 1. Conduit connection 1/2 NPT or PG 13.5, both sides: plug unused connection with metal plug (supplied). 2. connectors may be removed and connections made directly to process cover using 1/4 NPT internal thread in process cover. 3. cover can be inverted making optional side vents or side drains. 4. connectors can be inverted to give either 51, 54, or 57 mm (2.0, 2.125, or 2.25 in) center-to-center distance between high and low pressure connections. 5. Topworks can be rotated to any position within one turn counterclockwise of the fully tightened position. 6. cover end plugs are substituted for vent screws when optional side vents (Note 3) are specified. Document Number TBULM08001-03 2011 Schneider Electric. All rights reserved - August 2011