ELECTROMAGNETIC COMPATIBILITY TEST REPORT

Similar documents
TEST SUMMARY Seite 2 von 31. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Pass

Test Report. Product Name : Stackable Gigabit Ethernet Switch Model No. : DGS-3224SR, DGS-3324SRI, DGS-3324SR, DPS-500, DPS-900

CE Radio Test Report

KeyTek ECAT. Expert Computer-Aided Testing for pulsed EMI immunity. Technical Specifications

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

TEST REPORT. Fobsun Electronics Limited

Lite-On Power ChungHo Controlled. Do Not Copy.

Application for FCC Certificate On Behalf of Hisense Electric Co., Ltd. LED LCD TV

VCCI CLASS B COMPLIANCE REPORT

Reg Model : SKR001 Regulatory Assurance Certification

CE Test Report. : 45 Series WB module with Bluetooth

REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED ON GPS ANTENNA PART NUMBER 42G1215A-XT-1-N PREPARED FOR:

TEST REPORT- EMC. Report Number: DEN-001 Project Number: G Report Issue Date: April 24, 2012

Test Report. Product Name: Wireless 11g CardBus Model No. : CB54G, MS-6819 FCC ID. : DoC. Date of Receipt : Jun. 12, 2003

FCC 15B Test Report. : Bluetooth v4.0 Dual-Mode UART HCI Module. Address : Thompson Ave., Lenexa, Kansas 66219, USA

EMC TEST REPORT (Class B)

SH-7030 Specification DC to DC Converter

FCC DOC TEST REPORT. According to. 47 CFR, Part 2, Part 15, CISPR PUB. 22 ICES 003 Issue 6

EN 62311:2008 ASSESSMENT REPORT. Shanghai Bwave Technology Co.,Ltd.

Constant Voltage Mode

: i-chroma TM Reader. : None : IMMUNOFLUOROMETER EQUIPMENT. : BodiTech Med Inc.

ENGINEERING SPECIFICATION. 40W AC Adaptor. Part Number: PA W1

REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED ON GPS ANTENNA PART NUMBER 42G1215A-XT-1-N PREPARED FOR:

CERTIFICATE. Issued Date: Aug. 16, 2012 Report No.: R-ITCEP07V03

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

CERTIFICATE. Issued Date: Sep. 15, 2011 Report No.: R-ITUSP02V02

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

1601 North A.W. Grimes, Suite B Round Rock, TX (512) Fax: (512) January 20, 2012

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

ONETECH Testing & Evaluation Lab.

Application for FCC Certificate On Behalf of Hisense Electric Co., Ltd. LED LCD TV

TEST REPORT. No. 18PBI CUSTOMER Hess GmbH Licht+Form Lantwattenstraße 22 D Villingen-Schwenningen

ME to 30W Single Output External Power Medical Series. Features

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

FS50W Series LED Driver Input: VAC High Power Factor High efficiency For high bay light IP66 UL CB CE SPECIFICATIONS

HEC-100RTN-48QSCA Rev A1.0

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

TEST REPORT. For ELECTRONICS TECHNOLOGY (DONG GUAN) COMPANY LIMITED ETSI EN V1.4.1 ( ) ETSI EN V1.8.

Thermo Scientific ECAT

Revision Issue Date Pages Affected A0 08/14/2006 ALL Modify From CP-8120 Specification Rev:ED by Customer given.

Power Factor Model Number Voltage Voltage

12-15VDC (12V±5%) 24-28VDC (24V±5%)

FCC Test Report. APPLICANT : ZTE CORPORATION EQUIPMENT : cdma2000 Digital Mobile Handset BRAND NAME : ZTE MODEL NAME : N8000

CE Test Report. : Bluetooth Serial Module with integrated antenna (Please refer to section for more details.)

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Single Source, Total EMC Test Solutions

ENGINEERING SPECIFICATION. 65W AC Adaptor. Part Number: PA P1

TM3DI16G module TM3-16 inputs spring

Universal Power Supplies

EMC TEST REPORT (Class B)

Declaration of Conformity (DoC)

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

A Test Lab Techno Corp. EMC Test Report

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Interference Suppression Capacitor

48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

TO65SS 65 SINGLE SIDED TOTEM VERTICAL DIGITAL SIGNAGE DISPLAY

Type VRLTC tap changer

Safety Standards. Model Number: Unit Weight:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

PDD-300 pulsed diode driver

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

FCC Test Report. : TomTom International BV : GPS Navigation System. : FCC 47 CFR FCC Part 15 Subpart B

FEATURES DESCRIPTION SPECIFICATIONS

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

CEMASTER. Advanced Test Equipment Rentals ATEC (2832)

FEATURES DESCRIPTION FEATURES

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

EMC Immunity Testing Report

Enclosed Power Supplies

LPS. ME20 20W Single Output External Power Medical Series. Features

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

EMC TEST REPORT (Class B)

TM3DI16 module TM3-16 inputs

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Model Number Structure

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

OLU750P701N1A PSOV750701*(N)

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

ELEC-TECH INTERNATIONAL CO., LTD

Application for FCC Certificate On Behalf of Hisense Electric Co., Ltd. LED LCD TV LC-43N7000U, LC-43N7000C

Safety Standards. Model Number:

Communication Gateway COM 610. Product Guide

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

ELECTRONICS TESTING CENTER, TAIWAN Report No.: RBO EMC TESTING DEPARTMENT Page: 1/9

Application for FCC Certificate On Behalf of Hisense Electric Co., Ltd. LED LCD TV

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Safety Standards. Model Number:

LONG-RANGE HANDHELD TRANSMITTER P/N: CMD-HHLR-xxx

ADAPTER SERIES SST-AD60-C

EMC TEST REPORT (Class B)

EMI Test Report. Model Name: USB HUB Model Number: DX-B4PORT Brand Name: DYNEX Trade Mark: DYNEX FCC ID: XJIBLKDXB4PORT

OLU550P102U1U PSOV550102*

MINER-S Station Controller. Substation Automation

Efficiency (1) 110Vac 220Vac. (2, 3) 3330 ma 90 ~ 305 Vac 11 Vdc 35 W 84% EUC-040S333DS(6) EUC-040S333PS(6)

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Transcription:

Page 1 of 13 ELECTROMAGNETIC COMPATIBILITY TEST REPORT Product Name :IP113A Applicant Address :IC Plus Corp. :10F, No. 47, Lane 2, Kwang-Fu RD. Sec. 2, Hsin-Chu, Taiwan, R.O.C. Received Date:Sept. 04, 2003 Tested Date :Sept. 10, 2003 Notes: 1. This report will be invalid if duplicated or photocopied in part. 2. This report refers only to the specimen(s) submitted to testing, and be invalid as seperately used. 3. This report is invalid without examination stamp and signature of this institute. 4. The tested specimen(s) will be preserved for thirty days from the data issued. 5. The report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

Page 2 of 13 Test Report Verification Product Name Applicant : IP113A : IC Plus Corp. Measurement Standard : * Customer requirement EN 61000-4-2+A1:1998 WE HEREBY CERTIFY THAT: The measurements shown in the attachment were made in accordance with the procedures indicated, and the energy emitted by the equipment was found to be within the limits applicable. We assume full responsibility for the accuracy and completeness of these measurements and vouch for the qualifications of all persons taking them.

Page 3 of 13 TABLE OF CONTENTS TITLE PAGE NO. 1. General Information... 4 1.1 Test equipment... 4 1.2 Control software and firmware... 5 1.3 Description of EUT... 5 1.4 EUT & Peripherals setup diagram... 6 1.5 Description of peripherals... 7-8 1.6 EUT operating procedure... 8 1.7 Description of laboratory... 8 2. Electrostatic Discharge Test... 9 2.1 Climatic conditions... 9 2.2 Test requirement and procedure... 9 2.3 Test conditions... 9 2.4 Performance criteria... 10 2.5 Uncertainty of electrostatic discharge test... 10 2.6 Test results... 10 2.7 Photos of electrostatic discharge test... 11-13

Page 4 of 13 1. General Information 1.1 Test equipment Use Equipment No. Manufacturer or Type Model No. Date of Calibration HP Vectra 486/33M Computer D2871A N/A HP VGA Monitor D1193A N/A HP Keyboard C1405B #ABO N/A HP Vectra 486/33M Computer D2871A N/A IBM VGA Monitor 2248-002 N/A HP Keyboard C1405B#ABO N/A K5C02 KeyTek Control Center ECAT 103 MAY. 09, 2003 K5C02 Pacific Programmable Controller UPC-32 MAY. 09, 2003 K5C02 Xitron Power Analyzer 2503AH MAY. 09, 2003 K5C02 Pacific AC Power Source 3120AMXT-UPC32/MEP94 MAY. 09, 2003 K5C02 KeyTek Reference Impedance Module ERI3 MAY. 09, 2003 K5C03 KeyTek Control Center ECAT 103 NOV. 23, 2002 K5C03 KeyTek EFT/B Source E421 NOV. 23, 2002 K5C03 KeyTek Surge Network E510,E503 NOV. 23, 2002 K5C03 KeyTek EFT/B & Surge Coupler/Decoupler E4552 NOV. 23, 2002 K5C04 KeyTek Swell/Dip Interrupt Source EP62 OCT. 17, 2002 K5C06 Noise Lightning Surge Simulator LSS-712 MAR. 13, 2003 K5C07 KeyTek EFT Source CE-40 JUL. 09, 2003 K5C08 Noise Impulse Noise Simulator INS-410 FEB. 18, 2003 K5C35 NoiseKen ESD Simulator ESS-2000 FEB 20, 2003 K5C36 KeyTek Surge Network E503, E510A E505A, E4554 JAN. 23, 2003 K5C13 CHASE Bilog Antenna CBL 6111A MAY 06, 2003 K5C14 R&S Signal Generator Freq. Range : 9KHz 2.08GHz SMY02 JUL. 27, 2003 K5C15 Boonton RF Voltmeter 9200B JUL. 27, 2003 K5C18 NoiseKen Fast Transient Noise Simulator FNS-105L FEB. 18, 2003 K5C20 HOLADAY HI-3624 OCT. 23, 2002 K5C27 FCC Coupling Decoupling Network Freq. range : 150KHz~230MHz 801-M4-25 SEPT. 31, 2002 K5C28 FCC Coupling Decoupling Network Freq. range : 150KHz~230MHz 801-M3-25 SEPT. 31, 2002 K5C29 FCC Coupling Decoupling Network Freq. range : 150KHz~230MHz 801-M2-25 SEPT. 31, 2002 K5C48 FRANKONIA Coupling Decoupling Network Freq. CDN RJ45 MAY. 02, 2003 Range : 150MHz 230MHz K5C34 Keytek ESD Simulator MZ-15/EC JUN. 17, 2003 K5D20 AR Amplifier Freq. Range : 10KHz 220MHz 100W/150L N/A K5D23 AR Amplifier Freq. Range : 25MHz 1000MHz 100W1000M1A N/A K5D26 DANA TORINO-ITALY.DAS-G60.Power Frequenty Magnetic Field.DAS 1S 1000 N/A SCHAFFNER EM CLAMP KEMZ 801 NOV. 05, 2002 MILMEGA LINEAR AMPLIFIER AS0825-35 JUL. 14, 2003 EMC PARTNER HARMONIC-1000 AUG. 31, 2003

Page 5 of 13 1.2 Control software and firmware Use Control Software Firmware Revision Remark Keytek E500 Surgeware V4.10(c) 1995 Keytek E400 Burstware V4.10(c) 1995 Keytek Arbware V3.092 1993 5.11.1 5.11.1 Keytek Pqfware 2.10(c) 1995 5.10 EMC Partner 3.15/2.06 1.3 Description of EUT Manufacturer :IC Plus Corp. Sample name :IP113A Power supply :5VDC, 10W, 2A (From Adapter) Power cable :Unshielded cable 1.8m 1 Signal cable :Unshielded Fiber cable 1.5m 1 Unshielded uncross-over twisted-pair (RJ-45, plastic) cable 3m 4 Power Adapter: MANUFACTURER :Telkoor CORP. MODEL NUMBER :LES9947B03 SERIAL NUMBER :--------- INPUT POWER :100-120VAC, 0.5A OUTPUT POWER :5VAC/2A, 10W

Page 6 of 13 1.4 EUT & Peripherals setup diagram EUT Setup 110VAC/60Hz Adapter 5VDC/2A LAN Port Fiber Port A 110VAC/60Hz Accton HuB (10) HP Monitor (6) LAN Port HP PC (5) VGA Port 110VAC/60Hz Adapter 5VDC/2A B HP Keyboard (7) PS/2 Port IBM Mouse (8) Fiber Port EUT LAN Port IBM Monitor (2) VGA Port 110VAC/60Hz HP PC (1) LAN Port Accton HuB (9) HP Keyboard (3) PS/2 Port HP Mouse (4) A:Unshieldeduncross-over twisted-pair (RJ-45, plastic) cable, 3m 4 B:Unshielded Fiber cable, 1.5m

Page 7 of 13 1.5 Description of peripherals (1)PC MANUFACTURER :HP CORP. MODEL NUMBER :8894 SERIAL NUMBER :P3129-WOYO INPUT POWER :100-240VAC, 50/60Hz (2)Monitor MANUFACTURER :IBM CORP. MODEL NUMBER :2248-002 SERIAL NUMBER :5506721 INPUT POWER :100-240VAC, 50/60Hz, 1.2A (3)Keyboard MANUFACTURER :HP CORP. MODEL NUMBER :SK-2502C SERIAL NUMBER :M00030429 INPUT POWER :5VDC (From PC) (4)Mouse MANUFACTURER :HP CORP. MODEL NUMBER :M-S34 SERIAL NUMBER :LZR94800436 INPUT POWER :5VDC (From PC) (5)PC MANUFACTURER :HP CORP. MODEL NUMBER :DTPC-17 SERIAL NUMBER :SG95102408 INPUT POWER :100-240VAC, 50/60Hz, 1.5A (6)Monitor MANUFACTURER :HP CORP. MODEL NUMBER :D2825 SERIAL NUMBER :MY83443311 INPUT POWER :100-240VAC, 50/60Hz, 2A (7)Keyboard MANUFACTURER :HP CORP. MODEL NUMBER :3722 FCC ID :CIGE03633 INPUT POWER :5VDC (From PC)

Page 8 of 13 (8)Mouse MANUFACTURER :IBM CORP. MODEL NUMBER :M-SAU-IBM6 FCC ID :JNE211220 INPUT POWER :5VDC (From PC) (9)HuB MANUFACTURER :Accton CORP. MODEL NUMBER :3Com Baseline 10/100 Switch 24 Port SERIAL NUMBER :0100/7PWF001739 INPUT POWER :100-240VAC, 50/60Hz, 1.5A (10)HuB MANUFACTURER :Accton CORP. MODEL NUMBER :3Com Baseline 10/100 Switch 24 Port SERIAL NUMBER :0100/7PWF001322 INPUT POWER :100-240VAC, 50/60Hz, 1.5A 1.6 EUT operating procedure 1. Setup whole system for test as shown on setup diagram. 2. Powered on all equipments. 3. PC run Acctest.exe program. 4. Begin the test. 1.7 Description of laboratory TÜV R. certificate No. : I9664582-9911 CNLA certificate No. : CNLA-ZL97018 NAME OF SITE SITE LOCATION : Ecom Sertech Corp. Hsinchu (Spin-off from ITRI / ERSO on Apr. 01, 2003) : Rm.258, Bldg.17, NO.195, Sec. 4, Chung Hsing Rd., Chu-Tung Chen. Hsin-Chu, Taiwan 310 R.O.C.

Page 9 of 13 2. Electrostatic Discharge Test 2.1 Climatic conditions Ambient temperature : 25 Relative humidity : 55 %% Atmospheric pressure : 99.2 kpa 2.2 Test requirement and procedure The test was based on EN 61000-4-2+A1 (1998) and Customer requirement 2.3 Test conditions.source voltage / frequency : 110VAC/60Hz, single phase.r-c network : 330 Ω, 150 PF..Test Level : Air Discharge : 2KV, 4KV, 8 KV Contact Discharge : 2KV, 4 KV.Polarity : Positive / Negative.Number of test : 10 Discharges / Sensitive Polarity for Air Discharge. 25 Discharges / Sensitive Polarity for Contact Discharge..Time between test : 1 Sec.

Page 10 of 13 2.4 Performance criteria A. The equipment shall continue to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer. B. After the test the equipment shall continue to operate as intended. No degradation of performance or loss of function is allowed after the application of the phenomena below a performance level specified by the manufacturer. During the test, degradation of performance is allowed however. No change of actual operating state or stored data is allowed. C. Loss of function is allowed, provided the function is self recoverable or can be restored by the operation of the controls by the user in accordance with the manufacturers instructions. 2.5 Uncertainty of electrostatic discharge test The uncertainty of output voltage indication is ± 5% 2.6 Test results Test Requirement Customer requirement Performance verification (criteria) Test Air Contact Air Contact results discharge discharge discharge discharge Severity level 2 KV 4 KV 8 KV Polarity + B A A A pass - B A A A pass + B A A A pass - B A A A pass + B NR B NR pass - B NR B NR pass Note : NR means there is no requirement.

Page 11 of 13 2.7 Photos of electrostatic discharge test A:Air Discharg;C:Contact Discharge

Page 12 of 13 A:Air Discharg;C:Contact Discharge