Inductive sensor NI3-EG08K-Y1-H1341

Similar documents
Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Inductive sensor BI5-EM18-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

BL67 electronic module 8 configurable digital channels, PNP, channel diagnostics, 0.5 A BL67-8XSG-PD

Fieldbus I/O module PROFIBUS-DP 16 configurable digital channels, as PNP inputs or 2 A outputs TBDP-L2-16DXP

BL67 electronic module 4 analog inputs for current/voltage BL67-4AI-V/I

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

TBEN-L Multiprotocol Module for Ethernet Compact RFID and I/O Module Programmable via CODESYS V3 with WebVisu License TBEN-L5-4RFID-8DXP-CDS-WV

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

Technical Data. General specifications. Rated operating distance s n 3 mm

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Flow monitoring For the connection of intrinsically safe flow sensors IO-Link device with relay outputs FMX-IM-3UR38X

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Ethernet spanner Master to master data exchange, NAT router, 16 digital PNP inputs TBEN-LG-EN1

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

BL compact Fieldbus Station for DeviceNet 4 Analog Current Outputs BLCDN-4M12LT-2AO-I-2AO-I

TBEN-S Multiprotocol Module for Ethernet Compact RFID and I/O module TBEN-S2-2RFID-4DXP

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Compact multiprotocol I/O module for Ethernet 8 Digital PNP Inputs and 8 Digital PNP Outputs 2 A TBEN-LG-8DIP-8DOP

Profibus-DPV1 Set in IP20 TI-BL20-DPV1-2

TBEN-L Multiprotocol Module for Ethernet Compact RFID and I/O module programmable via CODESYS V3 TBEN-L4-4RFID-8DXP-CDS

Compact multiprotocol I/O module for Ethernet 16 digital PNP outputs TBEN-L1-16DOP

TBEN-L Multiprotocol Module for Ethernet Interface for 4 BL ident read/write heads (HF/UHF) TBEN-L5-4RFID-8DXP-CDS

Compact multiprotocol I/O module for Ethernet 8 Digital PNP Inputs and 8 Digital PNP Outputs 2 A TBEN-L1-8DIP-8DOP

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

Compact multiprotocol I/O module for Ethernet 16 Universal Digital Channels, Configurable as PNP Inputs or 2A Outputs TBEN-L1-16DXP

Compact multiprotocol I/O module for Ethernet 16 digital PNP inputs TBEN-L1-16DIP

Your Global Automation Partner. Teachable Capacitive Sensors. Operating Instructions

BL compact Multiprotocol Station for Industrial Ethernet 16 Digital PNP Inputs BLCEN-16M8LT-8DI-P-8DI-P

Your Global Automation Partner. Inductive Sensors uprox with IO-Link Interface. Operating Instructions

Kit for Simple I/O Communication via Ethernet Modbus/TCP/ EtherNet/IP / PROFINET in IP67 TI-BL67-EN-S-8

Compact Multiprotocol I/O Module for Ethernet 8 IO-Link Master Channels 4 Universal Digital PNP Channels, 2 A, Channel Diagnostics TBEN-L5-8IOL

Compact multiprotocol I/O module for Ethernet 16 configurable digital channels pnp inputs / outputs 2 A FGEN-XSG

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

standard, short, preferential, top

Ethernet Spanner Master to master data exchange, NAT router, 16 digital PNP inputs TBEN-L5-EN1

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs 8 digital outputs 2 A FGEN-IOM

Compact Multiprotocol I/O Module for Ethernet 16 Digital PNP Outputs TBEN-L4-16DOP

Pneumatic Control/Feedback

Pneumatic Control/Feedback

Profinet Set in IP20 TI-BL20-E-PN-4

PHOENIX CONTACT - 12/2007

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

Expansion Module for I/O Communication BL Ident RFID Module for Connecting 2 Read/Write Heads (HF/UHF) BL20-2RFID-S

Programmable Set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-2

Compact multiprotocol I/O module for Ethernet 8 universal digital channels, configurable as PNP inputs or 0.5 A outputs TBEN-S1-8DXP

Compact Multiprotocol I/O Module for Ethernet 16 Universal Digital Channels, Configurable as NPN Inputs or 2 A Outputs TBEN-L4-16DXN

Pneumatic Control/Feedback

Compact multiprotocol I/O module for Ethernet 16 digital outputs 2 A FGEN-OM

Compact Multiprotocol I/O Module for Ethernet 16 digital NPN Inputs TBEN-L4-16DIN

Compact multiprotocol I/O module for Ethernet 16 digital pnp inputs FGEN-IM

Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs, input diagnostics per channel TBEN-S1-8DIP-D

IP 69K M12 I/O ports LEDs indicating status and diagnostics

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Set for EtherCAT in IP20 TI-BL20-E-EC-S-8

NAMUR INDUCTIVE SENSOR ATEX/IECEx

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

IP 69K M12 I/O ports LEDs indicating status and diagnostics

BL compact Multiprotocol Station for Industrial Ethernet 8 Analog Current or Voltage Inputs BLCEN-8M12LT-4AI-VI-4AI-VI

PI-EX-ME-2NAM/COC-24VDC

Sensors with analog output

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Sensor boxes SRBG Key features

Thread length (overall length) material

Compact Multiprotocol I/O Module for Ethernet 8 digital PNP inputs, input diagnostics per channel TBEN-S1-8DIP-D

BL compact Multiprotocol Station for Industrial Ethernet 8 Analog Thermocouple Inputs BLCEN-8M12LT-4AI-TC-4AI-TC

Programmable Set for Simple I/O Communication via Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-S-6

PHOENIX CONTACT - 01/2008

PI-EX-ME-2NAM/COC-120VAC

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

Series 3730 Type Electropneumatic Positioner

Cylindrical designs Smooth barrel

Inductive proximity switches with long operating distance, series 500

Series 3730 Electropneumatic Positioner Type

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

PHOENIX CONTACT - 05/2007

5 Fieldbus Technology

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Compact Multiprotocol I/O Module for Ethernet 4 IO-Link Master Channels 4 Universal Digital PNP Channels, 0.5 A, Channel Diagnostics TBEN-S2-4IOL

LS 6600 Technical Datasheet

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Transcription:

ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12 x 1 male connector Wiring Diagram Type designation Ident no. 1003720 Rated switching distance Sn 3 mm Mounting conditions Non-flush Secured operating distance ð (0,81 x Sn) mm Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4 Repeat accuracy ð 2 % of full scale Temperature drift ð ± 10 % Hysteresis 1 10 % Ambient temperature -25 +70 C Output function Switching frequency Voltage Non-actuated current consumption Actuated current consumption 2-wire, NAMUR 5 khz Nom. 8.2 VDC ï 2.1 ma ð 1.2 ma Functional principle Inductive sensors detect metal objects contactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. Inductive sensors generate this field via an RLC circuit with a ferrite coil. Approval acc. to KEMA 02 ATEX 1090X Design Threaded barrel, M8 1 Dimensions 39 mm Housing material Stainless steel, 1.4427 SO Active area material Plastic, PA12-GF20 Max. tightening torque housing nut 5 Nm Electrical connection Connector, M12 1 Vibration resistance 55 Hz (1 mm) Shock resistance 30 g (11 ms) Protection class IP67 MTTF 6198 years acc. to SN 29500 (Ed. 99) 40 C 1 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Distance D Distance W Distance T Distance S Distance G Distance N 3 x B 3 x Sn 3 x B 1.5 x B 6 x Sn 2 x Sn Diameter active area B Ø 8 mm 2 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories IM1-22EX-T 7541232 Isolating switching amplifier, 2-channel; 2 transistor outputs; input NAMUR signal; selectable ON/OFF mode for wirebreak and short-circuit monitoring; switchable between NO / NC mode; removable terminal blocks; width 18 mm; universal voltage supply unit BST-08B 6947210 Fixing clamp for threaded barrel devices, with dead-stop; material: PA6 QM-08 6945100 Quick-mount bracket with dead-stop, chrome-plated brass, male thread M12 x 1. Note: The switching distance of proximity switches may be reduced through the use of quick-mount brackets. MW-08 6945008 Mounting bracket for threaded barrel devices; material: Stainless steel A2 1.4301 (AISI 304) BSS-08 6901322 Mounting bracket for smooth and threaded barrel devices; material: Polypropylene 3 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Accessories MBS80 69479 Mounting bracket for threaded barrel devices; material mounting block: Anodized aluminium IMC-DI-22EX- PNO/24VDC 7560003 2-channel isolating switching amplifier with M12x1 males, for peripheral use, IP67, zones 2/22, input circuits II(1) Ex ia, PNP transistor output NO IMX12-DI01-2S-2T-0/ 24VDC 7580020 Isolating switching amplifier, 2-channel; SIL2 acc. to IEC 61508; Ex-proof version; 2 transistor outputs; input Namur signal; ON/OFF switchable monitoring of wire-break and short-circuit; toggle between NO/NC mode; signal doubling; removable screw terminals; 12.5 mm wide; 24 VDC power supply Wiring accessories RKC4.221T-2/TEB 6628420 Connection cable, female M12, straight, 2-pin, cable length: 2 m, sheath material: PVC, black; culus approval; other cable lengths and qualities available, see www.turck.com 4 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com

Operating manual Intended use This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN 60079-0:2012 + A11 and EN 60079-11:2012. Further it is suited for use in safety-related systems, including SIL2 as per IEC 61508. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) É II 1 G and Ex ia IIC T6 Ga and É II 1 D Ex ia IIIC T95 C Da acc. to EN 60079-0, -11 Local admissible ambient temperature -25 +70 C Installation / Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please observe the maximum admissible electrical values. After connection to other circuits the sensor may no longer be used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof of intrinsic safety" (EN60079-14). Attention! When used in safety systems, all content of the security manual must be observed. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. service / maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed. 5 / 5 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com