The NI TB-2648/2649/2650/2651 terminal blocks configure your NI PXI/PXIe-2531 (NI 2531) in one of the following topologies. 1-wire 8 64 matrix

Similar documents
INSTALLATION INSTRUCTIONS SH160F-160M-NI SwitchBlock Cable

This installation guide describes how to install and connect signals to the NI TBX-2808 screw terminal accessory for use with NI SwitchBlock cards.

INSTALLATION INSTRUCTIONS NI TB-2630B Terminal Block for the NI PXI-2530B. Contents. Introduction

NI USB-6211/6218 OEM

USER GUIDE I/O Accessory For the NI PCIe-8237R GigE Vision Interface Device

Bracket and Mounting Dimensions

PXI and PXI Express Chassis Fan Replacement

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

Reconfigurable Embedded Chassis with Integrated MXI-Express (x1) MXI-Express Switch

NOTE TO USERS NI 61xx Pinout Labels for the SCB-68 Multifunction I/O S Series Modules/Devices Using the 68-Pin Shielded Connector Block

Electrical. SPECIFICATIONS SH Cable

1-Wire 4 x 128 Matrix Terminal Block for the NI PXI/PXIe-2532B

SH Cable Specifications

You need the following to set up and use your terminal block:

NI SMB-2145/2146/2147/2148

CALIBRATION PROCEDURE CAL Contents. Software

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

NI TB Introduction. Conventions INSTALLATION INSTRUCTIONS Wire Terminal Block for the NI PXI-2529

NI PXI-2567 Specifications

R Series for PXI Express Digital RIO with Kintex-7 325T FPGA. ni.com/manuals. This document explains how to install and configure the NI PXIe-7822R.

Electromagnetic Compatibility Guidelines

GETTING STARTED GUIDE NI Channel, 50 Arms Continuous, 24-Bit, Analog Input Module

NI WSN-9791 Ethernet Gateway

NI REM Remote I/O Overview DATASHEET. Bus Coupler for Remote I/O

Foundation Fieldbus Hardware and NI-FBUS Software

INSTALLATION INSTRUCTIONS LFH160 Cable

INSTALLATION INSTRUCTIONS Data Management Software Suite in the Evaluation Mode

NI-Industrial Communications for EtherCAT

NI R Series. Contents. Software CALIBRATION PROCEDURE

NOTE TO USERS NI 65xx Pinout Labels for the SCB-100 Digital I/O Modules/Devices Using the 100-Pin Shielded Connector Block

R Series Reconfigurable I/O Module (AI, AO, DIO) for PXI Express, 6 AI, 18 AO, 48 DIO, 1 MS/s AIO, 512 MB DRAM, Kintex-7 160T FPGA

USER GUIDE USB-634x/635x/636x OEM X Series USB-6341/6343/6356/6361/6363/6366 OEM Devices

NI PCIe-784xR, NI PXI-784xR, NI PXIe-784xR, NI USB-784xR, NI PCIe-785xR, NI PXI-785xR, NI PXIe-785xR, NI USB-785xR, and NI PXIe-786xR

CALIBRATION PROCEDURE NI PXIe Channel, Isolated Voltage/Current Analog Output Module

R Series Digital I/O Module for PCI Express, 128 DIO, 512 MB DRAM, Kintex-7 160T FPGA. This document describes how to begin using the PCIe-7821R.

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

Related Information Refer to the NI Switches Help for detailed information about features and programming options for your NI switch product.

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

Contents. Software Requirements. CALIBRATION PROCEDURE NI PXIe-4357

GETTING STARTED GUIDE

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals

R Series for USB Multifunction RIO with Kintex-7 160T FPGA. ni.com/manuals

CALIBRATION PROCEDURE PXIe channel, 16-bit, 400 ks/s/ch, Ch-Ch Isolated Analog Input Module. ni.com/manuals

GETTING STARTED GUIDE NI AO, 0 ma to 20 ma, 16 Bit Simultaneous

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

TBX-1316 High-Voltage Attenuator Terminal Block

NI CMS-9068 and NI MMS-9068

NI crio-9101/9102/9103/9104

Contents. Software Requirements CALIBRATION PROCEDURE NI TB-4353

PXIe Contents GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

SCC-RLY01 Relay Module

NI PXI-1042 Series Power Supply Shuttle

GETTING STARTED GUIDE NI Channel Solid-State Relay (SSR) Digital Output Module

24-Channel, ±24 V Precision PXI Source Measure Unit

INSTALLATION GUIDE AND TERMINAL BLOCK SPECIFICATIONS NI PXIe-4357 and TB-4357

PXIe Contents. Verifying the System Requirements GETTING STARTED GUIDE. 32-Channel Digital Pattern Instrument

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

12-Channel, ±24 V Precision PXI Source Measure Unit

NI PXIe-4138/4139. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Single-Channel System SMU

NI PXIe-6544/6545/6547/6548

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

NI CVS Required Components. Optional Equipment GETTING STARTED GUIDE. Compact Vision System with USB3 Vision and Reconfigurable I/O

GETTING STARTED GUIDE NI V, 32-Channel (Sinking Input), 7 µs C Series Digital Module

M Series USB-6221/6225/6229/6251/6255/6259 OEM Devices

NI USB-622x/625x/628x OEM

NI 653x Cable Adapter

R Series for USB Multifunction RIO with Kintex-7 70T FPGA. ni.com/manuals. Electromagnetic Compatibility Guidelines

LabVIEW for FTC Release Notes

SCXI -1313A Terminal Block

Thermal Kit for NI sbrio-9607/9627/9637

NI PXIe-1062Q Power Supply Shuttle

SCC-AO10 Isolated Analog Output Module

NI CMS Contents MAINTAINING HARDWARE. NI Condition Monitoring System for NI InsightCM Enterprise

GETTING STARTED GUIDE NI Ch 24 V Sinking DI, 8-Ch 24 V Sourcing DO SIL3 Capable

Contents. Software. CALIBRATION PROCEDURE NI 9216/ Channel, 24-Bit, 100 Ω/1000 Ω RTD Analog Input Module

USER MANUAL NI 9755 NI Powertrain Controls CompactRIO NOx Sensor Module Kit

NI PXIe-6555/6556. Contents GETTING STARTED GUIDE. 200 MHz Digital Waveform Generator/Analyzer with PPMU

FieldPoint cfp-20xx. Quick Start Guide. What You Need to Get Set Up

Contents. Software. CALIBRATION PROCEDURE NI Channel, 300 Vrms, 24-Bit, Simultaneous, Channel-to-Channel Isolated Analog Input Module

CALIBRATION PROCEDURE SCXI Contents. Software Requirements. ni.com/manuals

Getting Results with the NI 5752R

Single-Channel Precision System Source Measure Unit (SMU)

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

FieldPoint. FP-1000/1001 FieldPoint Quick Start Guide. Install the Network Module Mount the module on a DIN rail. What You Need to Get Set Up

Electromagnetic Compatibility Guidelines

Introduction... 1 System Diagram... 2 Hardware... 2 Powering the Hardware... 3 Wiring Harness... 5

Power and I/O Accessory

GETTING STARTED GUIDE NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

NI TSM-101x. LCD Characteristics NI TSM-1012 NI TSM-1015 SPECIFICATIONS. NI TSM-1012, NI TSM-1015, NI TSM-1017 Touch Screen Monitors

NI crio Contents USER MANUAL. Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules

Figure 1. NI-7935R. Related Information For information about the device specifications, refer to the NI-7935R Specifications at ni.com/manuals.

GETTING STARTED NI 9501 C Series Stepper Drive Modules and NI SoftMotion Module

GETTING STARTED GUIDE NI AI, 100 S/s/ch Simultaneous, Universal Measurements

LabVIEW DataFinder Toolkit

Embedded Real-Time Controller with Reconfigurable FPGA for C Series Modules. This document describes how to begin using the NI crio-9064.

INSTALLATION INSTRUCTIONS Data Management Software Suite

NI sbrio Safety Guidelines GETTING STARTED GUIDE. Single-Board RIO OEM Devices. This document describes how to begin using the NI sbrio-9627.

Transcription:

INSTALLATION INSTRUCTIONS NI TB-//0/ Terminal Blocks for the NI PXI/PXIe- Introduction The NI TB-//0/ terminal blocks configure your NI PXI/PXIe- (NI ) in one of the following topologies. Table. NI Configurations Created with the NI TB-//0/ NI Terminal Block NI TB- NI TB- NI TB-0 NI TB- NI Configured Topologies -wire matrix -wire dual matrix -wire matrix -wire dual matrix Refer to the NI PXI/PXIe- Specifications for terminal block specifications when used with the NI PXI/PXIe-. Make sure you have the following: NI TB-//0/ terminal block # Phillips screwdriver Caution Refer to the Read Me First: Safety and Electromagnetic Compatibility document at ni.com/manuals for important safety and compliance information. Note Refer to the Accessories section for accessories to connect signals from your terminal block to your system.

Install the Terminal Block To connect your terminal block to the NI switch module, refer to Figure and complete the following steps:. Connect the NI front connector to its mating connector on the terminal block.. Tighten the top and bottom screws on the back of the terminal block rear panel to hold it securely in place. NI TB- Front Connectors NI TB- Screws NI Front Connectors Figure. Installing the NI TB-//0/ Terminal Block Connecting Signals Note Refer to the Accessories section for recommended NI accessories for connecting signals to your terminal block. To connect signals to the terminal block, refer to Figures through for the pinout of your terminal block and complete the following steps:. Connect a compatible cable to the terminal block.. Connect the cable to your device under test, either directly or via a connector block such as the NI TBX-. NI TB-//0/ Installation Instructions ni.com

National Instruments Corporation NI TB-//0/ Installation Instructions Figure. NI TB- Terminal Block Signal Connections (-Wire Matrix) C C C C C C C C0 C C C C C C C C C C0 C0 C0 C0 C0 C0 C0 C0 C0 C0 C00 C C C C R R 0 0 0 0 0 C C C C0 C C C C C C C C C C0 C C C C C C C C C C0 C C C C C C C C R R C C C C C C C C C C C C0 C C C C C C C C C C0 C C C C C C C C C C0 R0 R 0 0 0 0 0 C C C C0 C C C C C C C C C C C0 C C C C C C C C C C0 C C C C C C R0 R C Top Connector Bottom Connector

NI TB-//0/ Installation Instructions ni.com Figure. NI TB- Terminal Block Signal Connections (-Wire Dual Matrix) BC BC BC BC0 BC BC BC BC BC BC BC BC BC BC0 BC BC BC BC BC BC BC BC BC BC0 BC BC BC BC BC BC BC BC BR BR B0C B0C B0C B0C0 B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C0 B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C0 B0C B0C B0C B0C B0C B0C B0C B0C B0R B0R B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C0 B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C0 B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C0 B0R0 B0R BC BC BC BC BC BC BC BC BC BC BC BC0 BC BC BC BC BC BC BC BC BC0 BC BC BC BC BC BC BC BC BC BC0 BR0 BR BC Top Connector Bottom Connector 0 0 0 0 0 0 0 0 0 0

National Instruments Corporation NI TB-//0/ Installation Instructions Figure. NI TB-0 Terminal Block Signal Connections (-Wire Matrix) 0 0 0 0 0 R R R R R R C C C C C C C C C C C C0 C C C C C C C C C C0 C C C C C C C C C C0 R0 R 0 0 0 0 0 Top Connector Bottom Connector R R R R R R C C0 C C C C C C C C C C C0 C C C C C C C C C0 C C C C C C C C R0 R C C

NI TB-//0/ Installation Instructions ni.com Figure. NI TB- Terminal Block Signal Connections (-Wire Dual Matrix) B0R B0R B0R B0R B0R B0R B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C0 B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C0 B0C B0C B0C B0C B0C B0C B0C B0C B0C B0C0 B0R0 B0R 0 0 0 0 0 Top Connector BR BR BR BR BR BR 0 0 0 0 0 BC BC BC BC BC BC BC BC BC BC BC BC0 BC BC BC BC BC BC BC BC BC0 BC BC BC BC BC BC BC BC BC BC0 BR0 BR BC Bottom Connector

Accessories Caution NI products typically must be operated with shielded cables and accessories to ensure compliance with Electromagnetic Compatibility (EMC) requirements. To determine if shielded cables or accessories are required for the product that the NI TB-//0/ will be used with, refer to the EMC specifications in the product s specifications document. If shielded cables or accessories are required for EMC compliance, do not use unshielded cables or accessories unless they are installed in a shielded enclosure with properly designed and shielded input/output ports, and are connected to the NI product using a shielded cable. If unshielded cables or accessories are not properly installed and shielded, the EMC specifications for the product are no longer guaranteed. Table. Accessories for the NI TB-//0/ Accessory Manufacturer Part Number NI TBX- unshielded, I/O connector block with DIN-rail mounting National Instruments -0 NI SHC- shielded cable ( m) National Instruments -0 NI SHC- shielded cable ( m) National Instruments -0 National Instruments Corporation NI TB-//0/ Installation Instructions

LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. 00 National Instruments Corporation. All rights reserved. B Jun0