PRODUCT RANGE. Cellswitch Infinity GSM Intercom Complex GSM Intercom Index GSM Intercom Mini GSM Intercom 2Button

Similar documents
CONTROL ANYTHING WITH YOUR CELLPHONE. Use your cellphone to remotely monitor and control the following applications with the CELLSWITCH 100

SMS ALERT 15 User Manual

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

Installation advice / help

page A.0240 Full_Product_catalogue_ BM.indb 110

Installation & User Manual For Cell Box Switch. GSM Cellular Gate opener and GSM alarm signalling device.

1 BUTTON GSM INTERCOM WITH KEYPAD (3G)

1 BUTTON GSM INTERCOM (3G)

MOBILE TARIFFS ANALYSIS 1 APRIL TO 30 SEPTEMBER 2018

GSM GATE INTERCOM WITH KEYPAD Control your gate with your mobile phone

JVA SMS Gateway User Manual

business every step of the way

GSM AUTO DIALER WITH IR BEAM DETECTOR

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

PA5000 SERIES USER MANUAL

Premium SMS Shared Short Code. A Premium SMS is an SMS that is sent from a mobile phone to a shortcode (eg ). a short code a 5 digit number.

TalkTalk Business MOBILE

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

User Manual Revision 1.02

Talk about great Data deals

Special Conditions and Service Description for amaysim Data Only

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

WEB SITE USERS GUIDE. Manual Contents

Installation Manual & User Instructions

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Installation Manual & User Instructions. MultiCom 100 / 500

Installation Manual & User Instructions

ASCL1 / ASCL2 CarLink Guide for Android Users

User Guide. Need help? Electricity Pay As You Go. Visit our online Help Centre

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software

Airtel Club Business *Newly Improved*

Communi-Cell Communicator Nokia Version

FSK TX CELLULAR PLUS. Installation and Programming Guide. Tel:

Installation & User Manual For Cell Switch Prime. GSM Cellular Gate opener and GSM alarm signalling device.

Installation Manual & User Instructions. MultiCom 500

An intercom completes any access control system by providing a means for the user of screening visitors before granting access, thereby significantly

: DOOR ENTRY UNIT. Programming Software USER MANUAL

Frequently Asked Questions - Cellphone Banking

Thetha Thetha Mobi 2 User Guide

Architectural and Engineering Specification. Brivo ACS 5000 Control Panels and ACS Service

User Guide. Need help? Economy 7 Pay As You Go. Visit our online Help Centre

WELCOME TO EE BROADBAND

amaysim Mobile Service Description

INDEX. Network Power Monitor R10 SNMP

Open gates & doors with your mobile phone.

GPS Vehicle Tracker (GPS+GSM+SMS/GPRS) User Manual (A5E-3)

GPS Vehicle and personal location tracker. User manual

RICA CONNECT AND RECHARGE. Your complete guide to making money, selling airtime and activating starter packs.

Y ello Welcome to MTN. Here s everything you need to know about SA s Bozza network.

New Account Creation. 2. Launch the CarLink app. from your phone s application list. 3. Enter a name for the vehicle.

605 D E C T G I n t e r c o m

PRO3200 Professional Modular Access Control Hardware

SmartSelect Tariff Plan Terms and Conditions. Availability. Activation/Tariff Plan

703 F o u r B u t t o n D E C T I n t e r c o m

Table of contents. Getting Started. Other Features. Unlocking. Lock ID & Maintenance. Finding & Sharing

Sentar V80 Watch User Manual

Pegasus HC Lighting Control Panel

ASCL1 / ASCL2. CarLink Guide for BlackBerry Users Audiovox Electronics Corporation. All rights reserved.

DAY DOT THE FIRST DAY OF THE REST OF YOUR BUSINESS

Installation Instructions

business every step of the way

Innovative Electronics for a Changing World. NPM-R10 Remote Network Power Monitor. With optional relay board and GSM module INDEX

PA2000 SERIES. USER MANUAL Rev. P CELL PHONE ENTRY SYSTEM. Platinum Access Systems Inc.

Cell C Tariff Plan and Terms and Conditions for the AVBOB Funeral Cover (Lifesaver) Powered by Cell C

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi.

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Your Charges Guide 2017

1. How and where can I find the terms and conditions of my contract?

We have determined that you are paying too much on your bill and have the opportunity to save!

TECHNICAL MANUAL NEW PANDINO 4. GSM Telephonics Communicator WITH QUAD-BAND GSM INDUSTRIAL MODULE

Installation & User Manual For. C e l l C O M + GSM Intercom System. Models AB, ABK, AS, ASK, HS, HSK, HB, HBK, FB, FBK Manual Version 2.3.

NU2 UIB 842 Manual GENERAL

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

GSM 12V GATE OPENER. No More Key Fobs! Open gates & doors with your mobile phone.

SMS Commander Manual

Pebbell FAQs and Troubleshooting Advice

PRO2200 Professional Modular Access Control Hardware

KDG27. GPS Tracker. Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking. Auto Accident Report Global Position System (GPS)

Lockitron Manual. The Abbreviated Guide to Getting the Most out of Your Lockitron

QUICK GUIDE. Publication number PEBBELL_v2_V9.1_ QUICK GUIDE HOIP TELECOM, 2016

ProLine GSM. Installation manual

QK-G031 Temperature GSM Remote Controller

BUSINESS IN THE DIGITAL WORLD. Everything you need to know about DOT (Digital Office Technology)

TM50 Touch Intuitive Touchscreen

MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

GPSteltronic Tracking Platform Operation Guide

Installation & User Manual For. MultiCOM Cellular Intercom System

SpyTrack Nano - GPS Tracker User Manual

Sunrise Prepaid Unlimited

Critical Information Summary

FIRST Gold for Business

GSM Intercom - QUICK START GUIDE

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

Student Achiever Account

GSM Communicator GJD710 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START THE INSTALLATION

6222 Two Door Module Technical Operations Manual

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

Transcription:

PRODUCT RANGE Cellswitch Infinity GSM Intercom Complex GSM Intercom Index GSM Intercom Mini GSM Intercom 2Button

CELLSWITCH Infinity 1 year free airtime, data, sms es and activated Vodacom and MTN simcards included. No activation and registration fees. Simply install the device and start using it. Dual sim - Both sim cards are online at the same time to control separate outputs. Unlimited alarm and control messages with our Instant Messenger App. Free welcome sms es to new users. Energizer keypad data interface for remote programming, control and alarms.

CELLSWITCH Infinity A missed-call on sim 1 can control output 1 and a missed-call on sim 2 can control output 1 or 2. 2 x Outputs (Control 2 separate gates). 4 x Inputs (Monitor various sensors). 12/24V Battery voltage monitoring and notifications. 10 000 programmable access control users. Restricted time-based access control for domestic and gardening services. Guest house feature with expiry date and access control notification. Daily Peak-hour gate open/close timers with 'Public and School Holiday feature. Beam obstruction alarms and open/close notification from gate controller. Low airtime, low battery and offline notifications. Detailed access control reports from the ultra fast Accentronix Cloud 9.0 online platform. Free welcome sms es to new users Message contains a web link that will give user-specific information with a list of all the devices they can use and how to use them, including time-based restrictions that may apply to the user. Connects to gate status output on gate controller for open/close monitoring. Unlimited alarm and control messages with our Accentronix Instant Messenger app. Alarms and events are sent by SMS, instant messenger and email. Advanced Electric Fence monitoring and control by connecting Directly to the energizer Keypad Data Interface. Monitor electric fence alarms, fence voltages, battery voltage, power-fail and tamper alarms on all popular energizers. Energizer remote keypad commands by SMS. Send multiple commands in one SMS 012345*0# 261# *#

CONNECTION TO GATE AND GARAGE FOR ACCESS CONTROL Connect the gate controller s status indicator directly to Input 1 or 2 to monitor gate open/close status. Permanent beam-obstruction alarms can be done by using any of the 4 Inputs. Connect the entrance or exit loop to Output 1 to force a car to be at the gate before allowing access. Set the integrated output timers to trigger the exit loop for 120 seconds to allow for enough time for a visitor to reach the exit gate. Use the output timers to automatically open the gate during peak hours but keep them closed during the weekend and public and school holidays. Connect a Mag Lock directly to Output 1 (n/c) and (com) terminals of the integrated relay (2Amp @ 32Vac/dc) and set the integrated output delay timer to 10 seconds. Connect Output 2 directly to the Pedestrian trigger. Output 2 is an open collector output which means it gives 0V to what ever it is connected to while it is switched on. (max 1 Amp @ 32Vdc). To drive heavier loads, connect the one end of the coil of an external (12/24Vdc coil) relay to 12/24Vdc and the other end of the external relay s coil to Output 2. If output 2 is switched on, it will supply 0V to the relay and turn it on.

QUICK CONNECTION TO ENERGIZER KEYPAD DATA INTERFACE Use Keypad Codes to communicate with your Energizer Status:? ON/OFF: 1234# ON: On OFF: Off Low Power: LP High Power: HP Send multiple keypad commands in one sms by separating them with a space i.e. 012345*0# 261# *# A keypad and Infinity can be connected to an energizer simultaneously. Connects and communicates directly with the Keypad Data Bus of most energizer makes and models. Select the specific model in Advanced Settings. Please note that some energizer models may display more or less info in the status and alarm messages than others. Do NOT connect anything to Output 2 of the Infinity while in energizer mode. A gate may be connected to Output 1 and be controlled by calling SIM 2 while the Infinity is in energizer mode. A call on SIM 1 will switch the energizer on or off. Advanced options Only applicable to some energizers: Two energizers can be connected to each other in master/slave mode and still be controlled separately with one Cellswitch Infinity. Zone 1 on: On1 Zone 1 off: Off1 Zone 2 on: On2 Zone 2 off: Off2

ACCENTRONIX INSTANT MESSENGER FOR UNLIMITED ALARM AND CONTROL MESSAGES Enjoy unlimited notification and control messages from and to your Cellswitch Infinity. Install the Accentronix Messenger app from the Android Play Store on your smart phone free of charge. If your phone temporarily loses its data connection you will receive messages by normal sms as a backup service. These messages are deducted from your subscription (60 sms es per month). Search for AccentroniX in the Play Store

ADVANCED FEATURES An energizer and gate can be connected simultaneously to an Infinity. The gate must be connected to output 1. A missed call on sim 1 will control the energizer and missed call on sim 2 will control the gate on output 1. Long range remote feature: Two or more Infinities can communicate with each other via the internet (not by sms). This allows for unlimited communications. For example if input 1 on one Infinity is triggered it will control output 1 on another Infinity 1000 kilometers away. Multiple inputs can be routed to multiple remote outputs. Mimic panel feature: Connect our 8in / 8out IO Expansion board to the Cellswitch Infinity to create a mimic panel that indicates alarm status of up to eight energizers. Low power feature: (Only available on Infinity Eon devices) Battery life of 10+ years depending on application. Water level control, Utility meter monitoring (water and electricity) and water trough monitoring on large farms. Device wakes up once a day to send in its status. Can also be set to wake up on input trigger alarms i.e. Water Level Low.

GSM INTERCOM SYSTEMS

GSM INTERCOM SYSTEMS Calls directly to your cellphone or landline. Includes activated and RICA registered Vodacom pre-paid sim card with R5.00 pre-loaded airtime. Up to 10 000 programmable users. 2 x Relay outputs (For main and pedestrian gates). 2 x Digital inputs (To monitor power and gate status). High quality stainless steel enclosure (GRADE 316). Operating voltage 12/24Vdc 500mA. Crystal clear sound. Backlit keypad. Cloud-based access control logs. Restricted time-based access control. Effortlessly manage a large number of access control users with our online Cloud 9.0 access control platform. Manage one access control list for multiple linked devices. If someone presses the programmed intercom button assigned to you, you will receive a call on you phone. Answer, and after you identified the person simply press 1 on your phone to open Gate 1. Press 2 on your phone to open Gate 2 (if applicable). Calls from the intercom to your number is charged to the sim in the intercom at standard network rates. Maximum call duration can also be set. Pressing button 9 on your phone will also open Gate 1. Free welcome sms es to new users The message contains a unique web link that will give user specific information with a list of all the devices they are linked to, intercom buttons assigned to them and how to use them.

GSM INTERCOM CONNECTION DIAGRAM Optional Connections: Connect a 220Vac coil relay to the Power Fail input. The Watchdog input is used for detecting if the gate is opened for longer than 3minutes. Online Settings PCB Output 1 and Output 2 are dry-contact (Normally Open) and (Common) relay outputs. Power the Intercom with 12 or 24Vdc directly from the gate battery.

RESTRICTED ACCESS CONTROL Restrict access control to specific days and times for Domestic and Gardening Service. Only allow access to main or pedestrian gates. Guesthouse feature expire after allocated time and date. Free welcome sms es to new users Message contains a web link that will give user specific information with a list of all the devices they can use including applicable restrictions.

ACCESS CONTROL LOGS Detailed time-stamped access control logs can be accessed online or automatically emailed daily, weekly or monthly.

INTERCOM LOGS Detailed time-stamped access control and button press logs can be accessed online or automatically emailed daily, weekly or monthly. Top 10 users and total number of calls per user statistics.

REGISTERING A DEVICE ON CLOUD 9.0 www.cellswitchportal.co.za Step 1: Make sure device is switched on with green led flashing slowly. Step 2: Enter any name and the cell number of the device. Step 3: Accept T&C..

SUBSCRIPTION When you buy a Cellswitch Infinity or Nano it already includes a subscription which includes airtime, data and sms es for 1 year with the two pre-installed and activated Vodacom and MTN sim cards. MTC sim s are included for devices going to Namibia which also includes the subscription. Do NOT load airtime on the sim cards. No activation and registration fees. Simply install the device and start using it. This option includes: all airtime, all data, 60 sms's per month, unlimited updates, all premium features, security upgrades and premium support. After 1 year you will have the option to renew the subscription for R365 excl vat. Alternatively, if you whish NOT to renew the subscription, you can manage the airtime yourself at the standard old Cellswitch 100 subscription charges stated in Option 2. Our system will notify you well in advance to either renew the subscription or alternatively load airtime on the sim cards. After 11 months, our system will automatically generate an invoice of R365 excl vat which will be emailed to the administrative account holder. Simply make the payment with the invoice number as reference and the subscription will be automatically renewed. This option ONLY includes the new Cellswitch Infinity and Cellswitch Nano. This option is currently NOT AVAILABLE for the Cellswitch 100 and GSM Intercom systems. If you need to increase the sms limit of 60 sms's per month, send us an email to enquire about our tailored subscription option. accounts@accentronix.co.za Our system will send you a notification by sms and email when you have 10 sms credits left for the specific month. Install the Accentronix Instant Messenger app to receive unlimited messages.

SELF MANAGE APPLIES TO GSM INTERCOM SYSTEMS This option applies to all GSM Intercom Systems and older Cellswitch 100 and 500 devices. It ALSO applies if you whish NOT to renew the Cellswitch Infinity or Cellswitch Nano Subscription after one year. This option excludes all airtime, data, sms s and premium features. Please take note of the 2016/2017 terms and conditions for our monthly service fees for Cellswitch and GSM Intercom Systems. Cellswitch 100, Infinity, Nano and GSM intercom 2 Button -> R20 airtime per month GSM Intercom Complex, Index and Mini -> R20 airtime per month The first 10 updates are free. (When you click on the 'Update Device' button). The first 3 updates per month is also free - thereafter R2.50 airtime per update. Any number of users may be added or removed before clicking on the 'update device' button. Activation of Time based access control additional R20 airtime per month. Service fees are deducted directly from the airtime on the sim card on the 1st of every month. This option allows you to manage and monitor your device, and allows us to provide you with a secure management platform with detailed access control and event logs. Airtime usage for Voice Calls for the GSM Intercom is charged by the network service provider as per their specified network rates. SMS's sent by devices is also charged at Network rates. Please contact your network service provider (Vodacom/MTN/Cell C/Telkom Mobile/MTC Namibia/Vodafone/Telstra Australia) for their specific call, sms and data rates. Our devices are in constant contact with our cloud platform and so additional airtime is used for data/internet transfer. This depends on the amount of traffic and logs that is sent to the Cloud 9.0 platform. We recommend that you monitor and load airtime regularly to cater for platform service charges, alarm/notification sms's and data. The system will notify you when airtime drops below a specified value that you can set in the 'Email Notification Options' section.

YOU IMAGINE WE CREATE YOUR ACCESS CONTROL LEADER OF CHOICE