BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Similar documents
BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

Type Quickstart

BVS 16 ATEX E088 X, IECEx BVS X. Operating Instructions

Type Quickstart (from device Version 2)

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Type ME43. Quickstart

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

SolConeX extra-low voltage flange socket

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

Electromotive process valve - 2 way angle-seat shut-off valve

SUBCON-PLUS-PROFIB...

Control Head for the integrated mounting on process valves

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Type 3320, 3321, AE3320, AE3321

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

MINI MCR-SL-CVS NC

Pneumatic Control/Feedback

Pneumatic Control Unit for the integrated mounting on process valves

PHOENIX CONTACT - 12/2007

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Pneumatic Control/Feedback

PI-EX-ME-2NAM/COC-120VAC

Installation manual plugs and connectors with screw connection (16/32 A)

PI-EX-ME-2NAM/COC-24VDC

MINI MCR-SL-MUX-V8-FLK 16

Metal Position Switch

SolConeX Wall-Mounted Socket, 16 A

Operating pressure (bar) kv factor (m 3 /h) *3)

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MANUAL Surge Protectors

Safety Instructions Cerabar S PMP71, PMP75

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Control Head for the integrated mounting on process valves

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Type 8694 Positioner TopControl Basic. Quickstart. English Deutsch Français

Operating Instructions

Digital electropneumatic Positioner for the integrated mounting on process control valves

SMARTLINE RM76 Supplementary instructions

MANUAL LML-P, LML-S, LML-Ex

Safety instructions Overvoltage protection B81-35

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

CPCI-PS24 24V-Power Supply

Pneumatic Control/Feedback

PHOENIX CONTACT - 01/2008

Technical Data. Dimensions

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

GRP Flameproof Visual Signal Xenon or Steady LED

MACX MCR-EX-SD LP(-SP)

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Electromotive process valve - 2 way shut-off globe valve

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Control Head for the integrated mounting on process valves

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Quick Start Guide MHM CC-PBF-EN, Rev 1 April Emerson A0701PBU. Emerson 701P SmartPower Module - Blue

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

Product manual plug, sockets and coupler 16 A.- Z0251

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Series 95000, 2/2 Direct solenoid actuated poppet valve

Refer to attachment for more details. Andreas Meyer

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Installation Instruction. HART Add-On Module

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive sensor BI1.5-EG08-Y1-H1341

Smart Wireless THUM Adapter

B63/ NS MS. EtherNet/IP LINK

Inductive sensor NI3-EG08K-Y1-H1341

Digital electropneumatic positioner SideControl

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Installation & Operation Manual

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Operating Instructions High-Voltage Switch HES 08/01

DR7100 SERIES Supplementary instructions

Flow. Flow. N/en

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

FLEX Ex Spring Clamp Terminal Base

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Cable entry systems for potentially explosive atmospheres

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

PHOENIX CONTACT - 02/2008

Rosemount 248 Wireless Temperature Transmitter

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Material pressure (bar) (Cv (US) kv x 1,2 Seat

MINI MCR-SL-PT100-UI-200

Type MS04. Redox potential sensor cube. Operating Instructions

Inductive sensor BI1.5-EG08-Y1-H1341

Transcription:

BVS 17 ATEX E 117 X / IECEx BVS 17.0100X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363 Electromotive control valve with ATEX approval and IECEx approval Elektromotorisches Regelventil mit ATEX-Zulassung und IECEx-Zulassung Vanne de régulation électromotorisée avec mode de protection ATEX et IECEx Additional Instructions Zusatzanleitung Instruction supplémentaire

We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Bürkert Werke GmbH & Co. KG, 2018 Operating Instructions 1801/00_EU-ML_00810687 / Original DE

Table of contents 1 ADDITIONAL INSTRUCTIONS... 3 1.1 Definition of terms / Abbreviation... 3 1.1 Symbols... 4 2 INTENDED USE... 4 3 PARTICULAR SAFETY INSTRUCTIONS... 5 3.1 Special conditions of use... 6 3.2 Special instructions for assembly and installation in the Ex area... 7 4 TECHNICAL DATA... 9 4.1 Conformity... 10 4.2 Standards... 10 1 ADDITIONAL INSTRUCTIONS The additional instructions describe the special requirements and measures for operating the device in potentially explosive atmospheres. Keep these instructions in a location which is easily accessible to every user and make these instructions available to every new owner of the device. Important safety information. Read the additional instructions carefully and thoroughly. Observe in particular: the Intended use, all safety instructions, the Special conditions of use. The additional instructions must be read and understood. These additional instructions contain the safety instructions as well as special specifications on operation in a potentially explosive atmosphere. All further instructions and descriptions about the device can be found in the respective operating instructions that must be observed just like the additional instructions. The operating instructions can be found on the Internet at: www.burkert.com 1.1 Definition of terms / Abbreviation In these instructions, the term device always refers to the electromotive control valves: Types 3320, 3321, 3323, 3360, 3361, 3363 and AE3320, AE3321, AE3323, AE3360, AE3361, AE3363. In these instructions, the abbreviation Ex always refers to potentially explosive. 3

Intended use 1.1 Symbols The following symbols are used in these instructions. DANGER! Warns of an immediate danger. Failure to observe the warning will result in fatal or serious injury. WARNING! Warns of a potentially dangerous situation. Failure to observe the warning may result in serious or fatal injury. CAUTION! Warns of a possible danger. Failure to observe this warning may result in moderate or minor injury. NOTE! Warns of damage to property. Important tips and recommendations. Refers to information in these operating instructions or in other documentation. Indicates instructions for risk prevention. Designates a procedure which you must carry out. 2 INTENDED USE Incorrect use of the electromotive control valve can be dangerous to people, nearby equipment and the environment. The electromotive control valve is designed for the controlled flow of liquid and gaseous media. The device is not suitable for use in highly charge-generating processes. The device (with the variable code PX48) is designed for use in: Explosion group II, category 3G Ex ec, T4 and Explosion group II, category 3D Ex tc, T135 C (see specifications on the approval sticker). During use, observe the permitted data, the operating conditions and conditions of use specified in the contract documents, operating instructions and on the type label of the device. Do not use alkaline cleaning agents to clean the device surface. If the valve position is relevant as regards safety in the event of a power failure: Use only those devices which have the SAFEPOS energy-pack (optional energy pack). Use the device only in conjunction with third-party devices and components recommended and authorized by Bürkert. Use the device only when in perfect condition and always ensure proper storage, transportation, installation and operation. Use the device for its intended purpose only. 4

Particular safety instructions 3 PARTICULAR SAFETY INSTRUCTIONS To prevent the risk of explosion, observe not only the safety instructions in the operating instructions but also the following safety instructions: DANGER! Risk of explosion due to open electric connections. Connect all electric plugs and sockets to the respective counterpart. Risk of explosion when removing the electric circular plug. Secure cable connections, which use circular plugs, with suitable locking clips. For example: EXCLIP, Phoenix Contact, Type SAC-M12-EXCLIP-M, art. no. 1558988, Type SAC-M12-EXCLIP-F, art. no. 1558991 or locking clips, ESCHA locking clip M12 x 1, art. no. 8040501. Remove the electric circular plug only after the power supply has been disconnected. Risk of explosion when opening the device. Do not open the device in a potentially explosive atmosphere. Risk of explosion caused by electrostatic discharge. In the event of a sudden discharge of electrostatically charged devices or individuals, there is a risk of explosion in the Ex area. Do not use the device in highly charge-generating processes. Take suitable measures to ensure that no electrostatic discharges can build up in the Ex area. Clean the device surface by gently wiping it with a damp or anti-static cloth only. Grounding the device: 1. Ground the actuator housing. The functional earth (FE) at the actuator housing must be grounded using a short line (max. 1 m) with a minimum cross section of 1.5 mm 2. The metal casings of the circular plug-in connectors are grounded via the actuator housing to which they are connected. 2. Ground the valve body. To establish the potential equalization, ground the valve body via an electrically conductive connection to the pipe system. DANGER! Risk of explosion. For work at the device and for operation in the Ex area, observe not only the safety instructions in the operating instructions but also the following: Observe information on temperature class, ambient temperature, degree of protection and voltage on the approval sticker. Do not use devices in areas where there is gas or dust with a lower ignition temperature than indicated on the approval sticker. 5

Particular safety instructions Installation, operation and maintenance may be performed by qualified technicians only. Observe the applicable safety regulations (also national safety regulations) as well as the general rules of technology for construction and operation. Do not repair the device yourself, but replace it with an equivalent device. Repairs may be performed by the manufacturer only. Do not expose the device to any mechanical or thermal loads which will exceed the limits described in the operating instructions. Use only cable and line entry points which have been approved for the respective application area and which have been screwed into place according to the associated installation instructions. The cable glands may be used for the insertion of permanently installed cables and lines only. Use pre-assembled cable glands according to the installation instructions supplied by the gland manufacturer. Before startup in the Ex area, check whether the cable gland has been installed as described in the associated installation instructions. Close all unnecessary cable glands with lock screws approved for the Ex area. To maintain the ignition protection type, all electric plug-in connections must be connected. 3.1 Special conditions of use For operation in an Ex area zone 2 and 22, the following applies: Do not use the device in dust atmospheres in which intensive charging processes can be expected. Ensure that the transient protection has been set to a value which does not exceed 140% of the measured peak voltage value at the supply connections of the device. Use the device only in an area with at least degree of soiling 2, as defined in IEC 60994-1. If devices feature a circular plug connection (multipole), the mating plug will be provided by the end user and is not object of the approval. The mating plug must satisfy the relevant requirements of IEC 60079-0, IEC 60079-7 and IEC 60079-31 and must have at least housing degree of protection IP65 according to IEC 60529. If devices feature a circular plug connection (multipole), use a special locking clip which prevents the plug from being loosened without a tool. Cylindrical threads with less than five thread turns are fitted with a seal to ensure the housing protection. The seals must comply with the relevant requirements of EN 60079-0, EN 60079-7 and EN 60079-31. 6

Particular safety instructions 3.1.1 Explosion protection approval The explosion protection approval is only valid if you use the modules and components authorized by Bürkert, as described in these operating instructions. The devices may only be used in combination with the valve types that have been approved by Bürkert. Otherwise, the explosion protection approval will be void. If you make unauthorized changes to the system, the modules or components, the explosion protection approval will also be void. The EC-Type Examination Certificates BVS 17 ATEX E 117 X and IECEx BVS 17.0100X were issued by Germany. DEKRA EXAM GmbH Dinnendahlstrasse 9 44809 Bochum, The PTB (CE0102) audits the manufacturing process. 3.1.2 Cleaning in the Ex area DANGER! Risk of explosion due to cleaning agents Only use cleaning agents that have been approved for cleaning in an explosive atmosphere. 3.2 Special instructions for assembly and installation in the Ex area To prevent the risk of explosion, observe not only the operating instructions but also the following instructions for assembly and installation: 3.2.1 Instructions for electric installation in the Ex area DANGER! Risk of explosion when removing the electric circular plug. Secure cable connections, which use circular plugs, with suitable locking clips. For example: EXCLIP, Phoenix Contact, Type SAC-M12-EXCLIP-M, art. no. 1558988, Type SAC-M12-EXCLIP-F, art. no. 1558991 or locking clips, ESCHA locking clip M12 x 1, art. no. 8040501. Remove the electric circular plug only after the power supply has been disconnected. Risk of explosion when opening the device. Do not open the device in an explosive atmosphere. Risk of explosion caused by electrostatic discharge. In the event of a sudden discharge of electrostatically charged devices or individuals, there is a risk of explosion in the Ex area. Do not use the device in highly charge-generating processes. Take suitable measures to ensure that no electrostatic discharges can build up in the Ex area. 7

Particular safety instructions Clean the device surface by gently wiping it with a damp or anti-static cloth only. Grounding the device: 1. Ground the actuator housing. The functional earth (FE) at the actuator housing must be grounded using a short line (max. 1 m) with a minimum cross section of 1.5 mm 2. The metal casings of the circular plug-in connectors are grounded via the actuator housing to which they are connected. 2. Ground the valve body. To establish the potential equalization, ground the valve body via an electrically conductive connection to the pipe system. Circular plug-in connector Actuator housing FE functional earth for grounding the actuator housing Valve body Ground the actuator housing. Ground the valve body to the pipe system. 3.2.2 Instructions for assembly in an Ex area DANGER! Risk of explosion when opening the device. Do not open the device in a potentially explosive atmosphere. Carry out work that requires opening the device outside the potentially explosive atmosphere. Unlock the cover: The supplied magnetic key is required for unlocking the cover. Dummy cover Marking Symbol for locking mechanism Symbol for open Symbol for closed Magnetic key Fig. 1: Grounding, example of an angle seat valve Fig. 2: Unlock the dummy cover 8

Technical data Hold the magnetic key against the symbol for the locking mechanism. The dummy cover is unlocked with a quiet click. Remove the cover: Risk of explosion in the Ex area! Do not remove the cover in a potentially explosive atmosphere. The supplied magnetic key is required for removing the cover. While holding the magnetic key against the symbol for the locking mechanism, turn the marking to the symbol for open. Remove the dummy cover. 4 TECHNICAL DATA To prevent the risk of explosion, observe not only the technical data in the operating instructions but also the following technical data. 4.2.1 Sticker for the Ex area ATEX approval number ATEX identification IECEx approval number IECEx identification Warnings Warning of a risk due to electrostatic charge, see instructions. Do not connect the device if electric voltage is present. Do not open the device if electric voltage is present. Fig. 3: Description: Sticker for the Ex area 9

Technical data ATEX identification Gas explosion protection identification II 3G Ex ec IIC T4 Gc II 3D Ex tc IIIC T135 C Dc Fig. 4: Equipment protection level Temperature class Explosion group Ignition protection type Dust explosion protection identification Device category Device group Description: ATEX identification 4.1 Conformity The electromotive control valve conforms to EC Directives as stated in the EC Declaration of Conformity. 4.2 Standards The applied standards, which are used to demonstrate conformity to the EC Directives, are listed in the Type Examination Certificate and/or the EC Declaration of Conformity. 4.2.1 Temperature ranges in the Ex area Ambient temperatures Device without display: -25 C...+65 C Device with display: -25 C...+60 C Devices with SAFEPOS energy-pack: -25 C...+55 C Maximum medium temperature: 130 C (temperature class 4) Temperature graph for seat valves: Types 3320, 3321, 3360, 3361 The values were determined under the following maximum operating conditions: Nominal diameter DN32 with 100% duty cycle at 16 bar medium pressure. Ambient temperature [ C] 70 60 50 40 30 20 10 Fig. 5: 0 0 20 40 60 80 100 120 140 Medium temperature [ C] Temperature graph Device version: without display module with display module with SAFEPOS energy-pack*, fieldbus gateway with or without display module 10

Technical data Temperature graph for diaphragm valves: Types 3323, 3363 The values were determined under the following maximum operating conditions: Diaphragm size 25 with 100% duty cycle at 10 bar medium pressure. Ambient temperature [ C] 70 60 50 40 30 20 10 Device version: without display module with display module with SAFEPOS energy-pack*, fieldbus gateway, with or without display module 4.2.2 Electrical data Explosion group Gas: IIC Dust: IIIC Category Constructional safety Gas: ec (increased safety) Dust: tc (protection through housing) Temperature class Gas: T4 Dust: T135 C for permitted temperature ranges, see section 4.2.1 Temperature ranges in the Ex area ) 0 0 20 40 60 80 100 120 140 Medium temperature [ C] Fig. 6: Temperature graph 11

www.burkert.com