Smart Grid Tie Microinverter User Manual

Similar documents
Smart Grid Tie Microinverter User Manual

22-60VDC Grid Tie Microinverter User Manual

GTI 300W GTI 500W GTI 600W GTI 800W GTI 1000W

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Enphase S-Series Microinverter and Engage Cable Safety

M250 (M LL) Safety

PRO-1250D CT MID DIN rail three phase four wire energy meter.

M215 (M215-60) Safety

DOWNLOAD PDF ENPHASE M250 INSTALLATION GUIDE

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

User manual. Microinverter EVT248

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

MDM 011-Z1 Regen Resistor

M215-Z Safety Information (M LL-IG-ZC)

PRO-75 SERIES. User manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

Installation and Operations Manual INVOLAR MAC250 Microinverter

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

Solis Single Phase Inverter

-5K-2G. Solar PV Grid Tie Inverter. inverter. Installation and Operation Manual. 2013, Ningbo Ginlong Technologies Co., Ltd.

PV Module Installation Instructions

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Installation/User Manual

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

ILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5

Redundancy unit CP-A RU

Operating instructions. Standstill monitor A / / 2011

ELV12 Series. Instruction Manual

Meikai N220/N300 Micro-Inverter Installation and Operation Manual

Solis Single Phase Inverter

Pure sine wave inverter. Product Manual

User Guide. Control Box. RoscoLED TM.

DC-D2212R / DC-D2212WR

Network Camera. Quick Guide DC-B1203X. Powered by

Installation/User Manual

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

EPS Power Supply

GCI-2G-W Single Phase Inverter

Network Camera. Quick Guide DC-D1223WX. Powered by

Operating instructions. Speed monitor D / / 2014

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Installation, Operation and Maintenance Manual

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

User Manual. 3KW/5KW PV Inverter

PV Rapid Shutdown device

XTM1250SA DIN rail three phase four wire LCD display energy meter

Solis Three Phase Inverter

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

Installation Guide for America Solar Wholesale Photovoltaic Modules

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11

Powerware 3105 UPS User s manual

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Model HM-535 Power Supply Installation and Service Instructions

Powerware 3105 UPS User s manual

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

RTU500 series Data Sheet Power Supply CP-E 24/2.5

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

DS-1H05 Ethernet-over-Coax Extender. User Manual

SMS 3xxx/SMS 4xxx Safety switch with separate actuator

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

PHOENIX CONTACT - 07/2006

Advidia A-15 & A-35 Installation Manual

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

PRO2DM DIN rail single phase two wire energy meter

POCKET MULTIMETER Model No: MM18

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

V /06/ Velleman nv

User Manual. Solar Inverter for Water Pump

SCM030. MPPT Solar System Controller With. DC to DC Booster Input. Installation & Operating Instructions

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

EVT248 MICROINVERTER. User Manual. Zhejiang Envertech Corporation Ltd.

Micro-Ohmmeter Model 6292

CS2 DMX Distribution Splitter

Installing Enphase IQ 6 and IQ 6+ Microinverters

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

User Manual. 1.5KW~5KW PV Inverter. Version: 1.1

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

1 Channel Strobe Controller ORDERCODE 40226

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

7-Port Fast Charging Station NAP Instruction Manual Please read carefully before use and keep for future reference.

User Manual PUH4-H2. 4K HDMI Splitter 1x4. All Rights Reserved. Version: PUH4-H2_2016V1.2

Installation and Operations Manual Micro-Inverter M S

Manual. Polaron SMPS Watt power supply for chargers. No. S2024. Copyright Graupner/SJ GmbH

MC 11 EB-2 Power supply cabinet with external bus, AC version

Rev1 QP-10-IM21UL/Rev Rev2 QP-10-IM21UL/Rev Rev3 QP-10-IM21UL/Rev Rev4 QP-10-IM21UL/Rev4

Transcription:

Smart Grid Tie Microinverter User Manual Thanks for choosing Smart Microinverters. Read the following instruction carefully before installation and operating, install and operate as specified by this user manual strictly to ensure your safe and benefit.

Catalogue Smart Microinverter Introduction.... 1 Smart Microinverter System Diagram..2 Important Safety Information..4 Technical Parameters....6 Installation. 7-8 LED Indicators....13 General troubleshooting....14 Wiring Diagram... 15-17 Warranty....18 Warranty Card.... 19 Explore Applications Diagram.. 21 Any relevant alteration is subject to the latest version without any prior notice.

Smart Microinverter Introduction Smart grid tie inverter is a compact unit, which directly converts direct current into alternating current for powering appliances and/or office equipments and connecting to utility grid. The AC output from Smart Microinverter is synchronized and in-phase with the utility grid. It is a key device of power generation systems such as PV power generation system, wind turbine power generation system. Smart Microinverter specially optimized design to work with modularization of DC power supplies which includes the mainstream solar modules, 18V (36 cells), 24V (60 cells) and 36V (72 cells) monocrystal and/or Polycrystalline solar panels, wind turbines and batteries. Smart Microinverters are stabilization, reliable and high conversion efficiency items. It is the best choice for PV power generation systems. Smart Microinverter can be easily placed and attached to the rack underneath of PV module. No need spaces for independent installation and low voltage DC wire connects from the PV module to Smart Microinverter can eliminate the risk of high DC voltage. Distributed modularization design philosophy for Smart Microinverter insures the productiveness of the whole system and will not affect by a single point of failure. Each Smart Microinverter is individually connected to each PV module in the array. This unique configuration means that an individual Maximum Peak Power Point Tracker (MPPT) controls each PV modules and insures that the maximum power available from each PV module is exported to the utility grid regardless of the performance of the other PV modules in the array which may be affected by shading, soiling, orientation or mismatch, etc. Smart Microinverter insures top performance for maximizing energy production from the whole PV system and gets return on investment in less time. 1/21

Smart Microinverter System Diagram The four key elements of a Smart Microinverter System are: PV Module The Smart Microinverter The Data Sender The Data Collector Grid-connected PV system Grid-tied PV systems consist of PV panels, grid-tied inverters, junction boxes, etc. The Smart Microinverters convert the DC from your solar panels and convert it into alternating current (AC) energy used in homes and businesses. Remote Monitoring The Data Sender collects performance information for each inverter in a user's system and transmits this data to the Data Collector and displays it on website, where users can view and manage the inverters performance of their solar power system, or view through Data Collector directly. NOTE: The DATA SENDER and the DATA COLLECTOR are optional elements. Before installing these elements, read all instructions and cautionary markings in their corresponding user manuals. 2/21

Features of Smart Microinverter 1. Unique circuit design, choice of import industrial electronic components, higher efficiency, more stable performance. 2. Creative MPPT technology, efficiency more than 99%, faster and more sensitive reaction, more reliable. 3. Parallel type design for DC input and modularization design for inverter, small volume, distributed installation, easy for system configuration, flexible for combination, strong expansibility of system. 4. Adopting high-frequency isolation transformer type, high efficiency, and high security. 5. Perfect electrical protection function. 6. Aluminum alloy housing, not rust, heat-resisting and cold-resistant as well as anti-corrosion. 7. Getting electronic circuit design, appearance design and other core technology patents. 8. High-quality thermal conductivity silica gel potting in, electronic components completely isolated from the air and it makes the aging of electronic components almost stop, greatly enhancing the life time of the product. 9. Highly DSP (Digital Signal Processor) as well as precision sensor IC adopted for getting accurately electrical parameters. Work with data sender and data collector to achieving remote monitoring, so the solar power generation information you can get and monitor at anytime and anywhere. (Purchase additional communication configuration parts separately) 3/21

Important Safety Information Read this First This manual contains important instructions for use during installation and maintenance of the Smart Microinverter. To reduce the risk of electrical shock, and to ensure the safe installation and operation of the Smart Microinverter, the following safety symbols appear throughout this document to indicate dangerous conditions and important safety instructions. DANGER! This indicates a hazardous situation, which if not avoided, will result in death or serious injury. WARNING! This indicates a situation where failure to follow instructions may be a safety hazard or cause equipment malfunction. Use extreme caution and follow instructions carefully. NOTE: This indicates information particularly important for optimal system operation. Follow instruction closely. Safety Instruction Do not use Smart Microinverter in a manner not specified by the manufacturer. Doing so may cause death or injury to persons, or damage to equipment. Perform all electrical installations in accordance with all applicable local electrical codes. Be aware that only qualified personnel should disassemble and repair the Smart Microinverters and non-qualified personnel should not install and/or repair. Do not attempt to repair the Smart Microinverter; it contains no user-serviceable parts. If it fails, contact customer service to claim a return merchandise authorization and start the replacement process. Tampering with or opening the Smart Microinverter will void the warranty. 4/21

If the AC cable connector on the Microinverter is damaged or broken, do not install the unit. Before installing or using the Smart Microinverter, read all instructions and cautionary markings in the technical description and on the Smart Microinverter System and the PV equipment. Connect the Smart Microinverter to the utility grid only after you have completed all installation procedures and after receiving prior approval from the local electrical utility company. Be aware that the body of the Smart Microinverter is the heat sink. Under normal operating conditions, the temperature is 15 C above ambient, but under extreme conditions the Microinverter can reach a temperature of 75 C. To reduce risk of burns, use caution when working with Microinverters. Do NOT disconnect the PV module from the Smart Microinverter without first removing AC power. The better disconnect DC terminal first. It may cause of components damaged if removing AC power first when Smart Microinverter still operation. It is available to disconnect AC power first when Smart Microinverter is not working but the better to disconnect the DC terminal first. Keep away from children, no touching, no playing so as not to electric shock when using. Please installed in place of low humidity and well-ventilated so as to avoid inverter overheating, as well as clear around the inflammable and explosive materials. 5/21

Technical Parameters (Suit for 60 cells solar panel which Vmp is 26-30V as well as Voc is 34-38V.) Power 250W Solar panels 250-280W DC input range MPPT Voltage DC MAX current 20-40VDC 24-33VDC 15A AC output range 120VAC(90-140VAC) or 230VAC(190-260VAC) Frequency range 50Hz/60Hz(Auto control) Power Factor >98.5% THD <5% Phase Shift <1% Efficiency 120VAC(90-140VAC) Peak Efficiency >90% Stable Efficiency >89% Efficiency 230VAC(190-260VAC) Peak Efficiency >92% Stable Efficiency >90% Protection Islanding; Short-circuit; Converse Connection; Low Voltage; Over Voltage; Over Temperature Protection Work Temperature -25-60 Grade of Waterproof Show Cooling IP67 Bi-color LED indicator Natural convection: no fans Stand-by Power 1-2W EMC Grid Disturbance Grid Detection Certificate Mounting Dimension EN61000-6-3:2007 EN61000-6-1:2007 EN 50178+EN 62109-1+VDE0126-1-12 DIN VDE 1026 UL1741 CE 80CM(length) Remark: The maximum PV Panel open circuit voltage CANNOT be more than 40V. 6/21

Packing Specification Packing Accessory Mechanical Size Net Weight/PCS Inner Box (L x W x H) Carton(L x W x H) Microinverter, AC Cord, User Manual(Warranty Card) 16.5 x 7.5 x 5.5CM 1.6KGS/PCS 26.5 x 20 x 11 CM 42.5 x 28 x 36 CM, 6pcs/CTN, 10/13KGS Installation 1. Diagrammatize DC input and AC output terminals, 2. Attach the Smart Microinverter to the racking or fix onto the wall, 7/21

3. Properly connect the positive and negative of solar panel and Smart Microinverter, 4. AC power cable connects with Smart Microinverter and residential power grid which refers to low voltage civilian single-phase power grid. 5. Switch on power grid after check for input and output connections are correct and Bi-color LED indicator start to flash in red and green in turn for five times, next follow on Bi-color LED indicator flash in green quickly which indicates that Smart Microinverter is in processing of MPPT operation for tracking down the Maximum power point from solar module. Finally, Bi-color LED indicator flash slowly and indicates that maximum power point lock-in. Smart Micro inverter proper functioning and output steady. 8/21

AC waterproof Connectors There are two connectors design for inverters, terminal connector included AC power line and communication data line. Two connectors are the same and can change at random. The electricity power cable which connecting to grid, no need data line. User should wrap up data line to avoid touching with electric conductor. AC power up for the RF transmit-receive module, RF transmit-receive module will be out of service when grid power off. 9/21

Cables 1. AC Power Cord European Standard UK Standard Australia Standard US Standard 10/21

1. Parallel Power Cable Please note that directionality of connecting cables between inverters. 2. Extension Power Cable 3. Transmission Direction of Parallel Power Cable When connecting for system, data transmission direction start from inverter which closest to grid to RF data sender. Please pay attention to cable direction, un-correct cable connection will lead to the RF data sender cannot receive inverter data correctly. 11/21

Note a) Two type AC cables for connecting when placed microinverters by stack. One is for connecting to utility grid, the other is for parallel connecting. A. For placing single microinverter, insulations seal for unused AC output terminal firmly to avoid electric shock. B. For placing stacked microinverters, insulations seal for unused AC output terminal of the last microinverter firmly to avoid electric shock. b). Max. 10 microinverters can be paralleled for a small group because of power load capacity of AC cables when paralleled stacking use. Too much microinverters for paralleled stacking will be leading to AC cables heat or burn down due to overloads. c). When stacking use, in theory, unlimited small groups can be setup base on sharing a AC main cable which is enough capacity for loads. For make sure the AC main cable you should use for connecting the small groups', users should check with the professional electrician for counting out the total power of all of small group's and the current. d). When paralleled stacking use, the microinverters placed in the end of each small group, there will be one unused connector of such microinverters, this unused connector should be screw up and prevent electric shock due to careless touching and the cap screw off. e). Microinverter will be automatic detect AC power grid and DC input data after DC power sources correct connection and grid switching on. Microinverter will be automatic startup and starting to operate after all condition for operation is satisfied. f). Microinverters paralleled stacking use also are available for batteries, small power wind generator which output DC directly or output DC through AC TO DC controller operation. g). Such paralleled stacking small groups are unlimited for PV system, only a set of AC power cable will be needed for connecting each small group, the more small groups setup, the high power output. 12/21

LED Indicators 1. Bi-color LED indicator in RED under any conditions includes but not limited: a) Over-voltage protection (DC input voltage higher than Max. input voltage of inverters), b) Over-temperature protection (inverters will shut down for power output when temperature of body of inverters higher than 60-65, and inverter will be automatically restart up when temperature down to 40-50 ), c) Power grid fault protection when 110VAC or 220VAC grid power outage and/or tripped, d) Islanding protection: inverter will be automatically shut down for power output when disconnect with power grid. 2. Bi-color LED indicator flash in GREEN under any conditions includes but not limited: a) Slow flashing for 1.5 seconds per each time, it is indicates low-voltage protection, DC input voltage lower than Min. input voltage of inverters, b) Continuously flashing for 0.5 seconds per each time, it is indicates inverter MPPT operation. 3. Please note that above operations only run at grid-connected status. 13/21

Troubleshooting a non-operating Smart Microinverter 1. System halted and /or without power output a) Check if switch of Smart Microinverter is turn on or not, b) Check if the DC connections to Smart Microinverter are correct or not, c) Check if any reverse DC connections for positive or negative or not, d) Check if DC input voltage is within the range of the Smart Microinverter s not, e) Check if the utility grid voltage and frequency are fit in with the serviceable range of Smart Microinverter or not, f) Check if fuses of DC side are fusing or not, g) Check if utility grid voltage properly connecting to Smart Microinverters or not. 2. DC power supply is normal but no power output: a) Check if utility grid voltage is connecting to Smart Microinverter or not, b) Check if utility grid voltage is fit in with the serviceable range of Smart Microinverter or not, c) Please visual inspection for the LED operation status, red LED will turn off and green LED will flash or run when inverter connecting with DC power supply which input voltage is fit in with the range as specified and power grid properly. If still no power output when green LED flash or run, probably internal components are damaged, in such case, please turn the defective inverter back for further analyze, d) Please visual inspection for the LED operation status, red LED still turn on and green LED without any flash or run when inverter connecting with DC power supply which input voltage is fit in with the range as specified and power grid properly, probably internal components are damaged, in such case, please turn the defective inverter back for further analyze. 14/21

Smart Microinverter Stack Wiring Diagram 15/21

Smart Microinverter Three Phase output Wiring Diagram 16/21

PV Power Plant Remark: When microinverters placed in large-scale of PV power generation sites, equipped lightning protection facilities and junction boxes and low pressure electricity cabinets are needed as well as ground grounded safely. 17/21

Warranty Warranty Conditions Warranty Period: 15-year limited warranty period. Warranty Evidence: The B/L,Tracking no, and a completed warranty card. We grant an implied warranty of 1 year to the inverter from date of purchase for repair or replace the Defective Product free of charge includes freight cost. Furthermore, we provides an additional limited warranty for 14 years for repair or replace the Defective Product free of charge but non-free of freight charge. If your device has a defect or malfunction during the warranty period, please also contact our customer service staff or your retailer or installer. Warranty claims are excluded for: Alterations or repairs to the unit without prior authorization Improper use or operation of device Improper and non-standard installation operating the equipment with defective safety devices Impact of foreign objects and force majeure (lightning, surge, storm, fire) Inadequate or nonexistent ventilation of the device disregarding of safety regulations shipping damage The Product has been improperly stored or was damaged while in possession of the Dealer or end user; WARNING! Only qualified electrical professionals can do the trouble shooting of the Smart Microinverter system. WARNING! Do not disconnect the Microinverter from its PV module when the inverter is still operating. Disconnect the inverter from the PV module during running may damage the Microinverter and bring electrical hazard to the person nearby. WARNING! Disconnect the AC grid first before disconnecting the inverter from the PV module. WARNING: Do not attempt to repair the Smart Microinverter. This may bring electrical hazard to the person and it will also void the Microinverter warranty. If troubleshooting methods fail, please contact customer support to return the Microinverter and initiate for Warranty replacement Card (Invalid process. Duplicate) 18/21

Customer Feedback: Name Country and/or Territory Telephone Email Purchase Channels and/or Sources Models Date of Purchase Date of Installation Time of Using Brief Fault Description Improvement Suggestions Distributor and/or Sales Representative Distributor Name Telephone and/or Email Sales Representative Date of finish Disposal QC Date of Customer Feedback Disposal Technician Others Other Supplementary Comments or Descriptions from Customers 19/21

20/21

Explore Applications Diagram 1.Compatible with 60 cells solar panel which Vmp is 26-30V Voc is 34-38V 2. Work with wind turbine, output DC voltage is fit in with the range as specified and a 24V charge controller needed to be used if the wind turbine without build-in AC TO DC charge controller. 3. Work with battery, PV module and wind turbine charging the battery and battery discharging to inverter for converting AC power which will feed into power grid. 21/21