LONWORKS Power Line Communication Adapter

Similar documents
1201L-1K RTD Controller. Revision 1.1. Nico Technology Ltd. 1 Rev.1.1

SmartRouters Optionally with Bus Diagnostics RTRS RTRSD

SREDU Double Connection Option Card for Lon Star Coupler RER 111

LX Series Remote Input/Output (I/O) Controller

R3-NL1 LONWORKS INTERFACE MODULE BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL. R3-nL1 MODEL

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

INSTALLATION INSTRUCTIONS

Actuator Zone 1 Mar 2004

LONMANAGER NSS-10 MODEL

Connection box ECblue (LON)

Manual Release 09/2002. cm-lon FOR LOGO! Communication with LOGO! with LON systems

SIOX Four I/O Mini Module

Busmodul - LonWorks (R)

LON bus LonWorks Network in Protection and Control Systems. User s manual and Technical description

Fieldbus Appendix ANYBUS -S LonWorks

M7410G LINEAR VALVE ACTUATOR WITH LON CAPABILITIES

R3-NL2 INSTALLATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL LONWORKS INTERFACE MODULE MODEL. (I/O 56 points)

Pyxos FT Network Chip 11500R

LOCAL DISPLAY UNIT (LDU)

NodeBuilder 3.1 Development Tool Model 10020

LONWORKS Option Technical Manual

Excel Smart I/O Compact XFCL2A1 AND XFCL3A1

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

MIC-2 Multi-instrument DATA SHEET

PXR11 PXR12. System controllers DESIGO PX

TOSVERT VF-S11 series LONWORKS option unit Communication Function Manual

i.lon SmartServer Models 7210xR-4xx, , 72160, and Description Programmable

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

DTS LonWorks Map Version 2.0U TABLE OF CONTENTS

LON-module for MULTICAL 601

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

TELN 1018 Automotive Four Channel Input Node Version 1.0

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

Easylon Network Components

TELN 1402 Gateway Interface Module Version 1.0. Users Manual July 1998

EXOcompact. Freely programmable controller

Anybus X-gateway LonWorks Interface

TAC Xenta 121-HP Programmable Heat Pump Application

Operating instructions RFID evaluation unit DTE / / 2016

SAFETY PRECAUTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

DOMOTICA ED EDIFICI INTELLIGENTI UNIVERSITA DI URBINO

LRC-XDP. LRC-XDP Datasheet. LRC-XDP Display Panel for Toshiba air-conditioning units. Description

MODEL 1600 FEATURES DESCRIPTION WIRING AND INSTALLATION NETWORK DISPLAY

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

TAC Xenta 301. Controller, Freely Programmable

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ]

TELN 1229/1020 Automotive 10 Switch Node Version 1.0. Users Manual January 1998

MIC-2 MKII, Multi-instrument DATA SHEET

Optidrive Applications Support Library

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

LON Module for Variable Speed Drive

LONMARK Product Conformance Review and Checklist

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

TOSHIBA CMOS Digital Integrated Circuit Silicon Monolithic TMPN3120FE5MG

Belimo Gateway MP to LONWORKS - UK24LON

DS A MN LCD I/A SERIES MICRONET LCD APPLICATION SPECIFICATION

7. How to access FC 100 parameters 49

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Operating instructions. Speed monitor D / / 2014

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

Installation- & user instructions

Manual 09/11 MN Z-EN. NZM-XATS-C Automatic Transfer Switch-Controller Modbus Communication Protocol

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

Operating instructions. Standstill monitor A / / 2011

IntesisBox Modbus Server - LON

Next Generation Intelligent Lon EIA/ANSI 709 Router Datasheet

MODEL 2000T Initial Draft

Automatic Transfer Switch OTM_C_20D. Installation and Operation Instructions

AB Axis Industries. Use

Compact I/O Module XIO-4AO LON ANALOG OUTPUT MODULE

Rotary actuator for ball valves KNX / PL-Link

Installation- & user instructions

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

Automatic Transfer Switch OTM_C20D

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

LON I/O Module DR-N 8S-10A Art. no.:mtn881801

KOLLMORGEN. SERVOSTAR CD. SERCOS IDN Manual M-SS rev. F. Solutions by D A N A H E R M O T I O N

LNT 505 Installation and Commissioning Manual

SAFETY PRECAUTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

MCH Series Drives LonWorks Communications Guide

Pyxos FT Network Chip 11500R

Functional profile. Wind Sensor Interface

Distributed Power System SB3000 Synchronous Rectifier &RQILJXUDWLRQDQG3URJUDPPLQJ

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

LONMARK Functional Profile: Refrigerated Display Case Controller: Defrost Object

Operation manual. HDOM-Profibus-V0. More options please visit;

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

TOSHIBA CMOS Digital Integrated Circuit Silicon Monolithic TMPN3120FE3MG

Model IR4000M. HART Field Device Specification Multi-Point Monitor. Instruction Manual 07-08

Modbus Remote Communication Protocol for REM 54_. Technical Description

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

DX561 Digital Input/Output Module

ANLEITUNG / MANUAL EMU ALLROUNDER EMU PROFESSIONAL. Quality that counts. Made in Switzerland

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

TOSVERT VF-PS1 / VF-FS1 series LONWORKS option unit Communication Function Manual

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

IntesisBox LON - KNX

Belimo Gateway MP to Modbus RTU - UK24MOD

Transcription:

ABB AB P.O. Box 1005 SE-611 29 NYKÖPING Sweden Tel: +46-155 295000 Fax: +46-155 288110 LONWORKS Power Line Communication Adapter CAL 06000/CCL 06000 User s Manual Rev A Page 1 of 15

Table of Contents 1 GENERAL...3 2 PRODUCT DESCRIPTION...3 2.1 PRODUCT OVERVIEW...3 2.2 TYPE DESIGNATION...4 3 INSTALLATION...4 3.1 COMMISSIONING/OPERATION...4 3.2 SERVICE LED...4 4 TECHNICAL DATA...5 4.1 DIMENSIONS...5 5 LONWORKS...6 5.1 COMMUNICATION OBJECTS...6 5.1.1 SNVT_reg_val_ts...9 5.1.2 Status of objects...10 5.1.3 Alarm of objects...11 5.1.4 Load Profile Reading...12 5.2 EXPLICIT MESSAGES...12 6 ABBREVIATIONS AND ACRONYMS...14 7 INDEX...15 2006-2007 by ABB AB. All rights reserved. Trademark Information Echelon, LON, LONMARK, LONWORKS, LonBuilder, NodeBuilder, LonManager, LonTalk, LonUsers, LonPoint, Neuron, 3120, 3150, the Echelon logo, the LONMARK logo, and the LonUsers logo are trademarks of Echelon Corporation registered in the United States and other countries. LonLink, LonResponse, LonSupport, and LonMaker are trademarks of Echelon Corporation. Page 2 of 15

1 GENERAL This manual contains information about the ABB LonWorks Power Line Communication (PLC) adapter, which is an adapter of the serial communication adapters (SCA) family for electronic electricity meters manufactured by ABB Automation Technologies AB. Throughout this manual the ABB LonWorks Power Line Communication (PLC) adapter will be referred to as the SCA or the adapter. The purpose of this manual is to give the user a good overview and understanding of the features the ABB LonWorks PLC adapter offers. WARNING! The voltages connected to the SCA are dangerous and can be lethal. Therefore it must be insured that the terminals are not touched during operation. When installing the SCA all voltages must be switched off. Note: The adapter is equipped with a fuse for overload protection. 2 PRODUCT DESCRIPTION The ABB LonWorks PLC adapter is an ABB serial communication adapter product that enables automatic meter reading (AMR) of ABB electricity meter over a power line network using the LonTalk protocol. Like all other ABB serial communication adapters the ABB LonWorks PLC adapter have the size of two DIN-modules and follows the ABB s pro M-standard, which defines mechanical dimensions, way of mounting (35 mm DIN-rail) and design outlook. Furthermore the adapter follows and meets the safety requirements of DIN EN 50090-2-2. The ABB LonWorks PLC communication adapter is available both for the proprietary A-band for electrical utilities and the public C-band. The adapter conforms to the LonMark profile of Utility Data Logger. 2.1 PRODUCT OVERVIEW The different parts of the communication adapter are depicted below. Figure 1: SCA parts. 1. Service pin. 2. Label with type designation and Neuron ID. 3. Terminal for connecting power. 4. Infra-red communication port. 5. Service LED. Page 3 of 15

2.2 TYPE DESIGNATION Below are tables with explanation for all positions in the type designation for the SCA. Type Pos 1 2 3 4 5 6-8 Basic Serial Communication Adapters Media Power Line, Band A Power Line, Band C Ethernet GSM/GPRS RS 232 Twisted Pair T Protocol LonWorks M-Bus C A C E G R L M Supply voltage Powered by device 4 100-240 V 5 220-240 V 6 Optional functionality No options 000 Table 1: Type designation of ABB Serial Communication Adapters. 3 INSTALLATION 1. Disconnect the power supply. 2. Strip the wires and connect them to the top terminals of the SCA. 3. Place the SCA to the left of the meter and snap it on the DIN-rail. 4. Verify that the SCA is correctly wired and the voltage is according to the technical specification before the power is turned on. 0 3.1 COMMISSIONING/OPERATION Figure 2:Installation of the SCA. Before the communication adapter is commissioned the Service LED is flashing, after commissioning it is off. 3.2 SERVICE LED The Service LED (2) in figure 1. indicates the state of the communication adapter. The chart below describes the state of the communication adapter and how the Service LED indicates this. Service LED Communication Adapter Status Green Service pin pushed in. Flashing Green Communication adapter not commissioned. Flashing Red Wink Page 4 of 15

4 TECHNICAL DATA Network Protocol and Standards Compatibility Data protocols: LonWorks profile Utility Data Logger. Communication standard: EN 50 065-1 Frequency: A-band 86 khz C-band 132 khz Power Supply Nominal voltage: 220-240 V AC Voltage Range: - 20% to +15% of nominal voltage. Frequency: 50/60 Hz ± 5% Power consumption: 2.5 VA at 230 V AC, 50 Hz. Terminal wire area: 0 2.5 mm² Recommended tightening torque: 0.5 Nm Environmental Specifications Operating temperature range: -40 C to +25 C Storage temperature range: -40 C to +70 C Humidity: 75% yearly average 95% on 30 days/year Standards Safety: DIN EN 50090-2-2. Mechanical Data Casing material: Polyamide Protection class: IP 20 Weight: 189 g 4.1 DIMENSIONS The physical dimensions of the SCA are displayed below. Power 1 4 ABB IR Interface Ethernet D51 Figure 3: The physical dimensions of the SCA. Page 5 of 15

5 LONWORKS LonWorks is a communication system for home and building automation. It is a decentralized system with distributed intelligence. LonWorks supports communication on various media. The adapter consists of a power line transceiver and a 3120 Neuron processor for communication over the power line as a media according to EN 50 065-1. Depending on model the communication adapter uses the A-band (86 khz) or the C-band (132 khz) for communication. NOTE: Like all products that communicate over the power line, the adapter may be affected by the prevailing network condition, like harmonics and the loads that are attached. 5.1 COMMUNICATION OBJECTS The communication objects can be divided into two groups, node objects and register objects of the profile Utility Data Logger. Normally all values of the objects are updated every 10 seconds, however faster updates of status and alarm objects can be achieved by sending an nvirequest of RQ_UPDATE_STATUS or RQ_UPDATE_ALARM respectively to the adapter. Node Object Register Network variable SNVT Type Description name nvirequest SNVT_obj_request Supports RQ_NORMAL, RQ_UPDATE_STATUS, RQ_REPORT_MASK, RQ_CLEAR_STATUS, RQ_UPDATE_ALARM and RQ_CLEAR_ALARM. nvostatus SNVT_obj_status Status of object. nvoalarm SNVT_alarm Alarm output of object. Utility Data Logger registers Register Network variable name Time nvotime SNVT_time_stamp year: 0,..,3000 (AD) month: 0,..,.12 day: 0,..,31 hour: 0,..,23 minute: 0,..,59 second: 0,..,59 nvitimeset SNVT_time_stamp year: 0,..,3000 (AD) month: 0,..,.12 day: 0,..,31 hour: 0,..,23 minute: 0,..,59 second: 0,..,59 SNVT Type Valid Range Description nvimastertime SNVT_time_stamp year: 0,..,3000 (AD) month: 0,..,.12 day: 0,..,31 hour: 0,..,23 minute: 0,..,59 second: 0,..,59 Reading of real time. Set real time (Normal). Note: nvitimeset can only set time when the time difference is less than 300 seconds between the newly set time and the current time stored in the electricity meter. Setting of real time (Master). nvopwcutcount SNVT_count 0,..,65 535 Cumulative power cut counter. Resolution (1 count) Page 6 of 15

nvopwcutlength SNVT_elapsed_tm day: 0,..,65 534 hour: 0,..,23 minute: 0,..,59 second: 0,..,59 millisecond: 0,..,999 nvorelay1 SNVT_switch value: 0,..,100 % state: 0 off 1 on 0xFF undefined nvorelay2 SNVT_switch value: 0,..,100 % state: 0 off 1 on 0xFF undefined nvos01 SNVT_switch value: 0,..,100 % state: 0 off 1 on 0xFF undefined nvos02 SNVT_switch value: 0,..,100 % state: 0 off 1 on 0xFF undefined Cumulative power cut length. Not in use. Not in use. State of S01 input. State of S02 input. nvoregval1 SNVT_reg_val_ts See 5.1.1. below. Current value of register object. nvihisttime1 SNVT_time_stamp year: 0,..,3000 (AD) month: 0,..,.12 day: 0,..,31 hour: 0,..,23 minute: 0,..,59 second: 0,..,59 History value select, for request of Load Profile data. nvohistval SNVT_reg_val_ts See section 5.1.1. below. ncibasevalue1 SNVT_reg_val raw: -2147483648 to 2147483647 unit: reg_val_unit_t enumeration type nr_decimals: 0,..,7 nvoregvals01 SNVT_reg_val_ts See section 5.1.1. below. nvihisttimes01 SNVT_time_stamp year: 0,..,3000 (AD) month: 0,..,.12 day: 0,..,31 hour: 0,..,23 minute: 0,..,59 second: 0,..,59 nvohistvals01 SNVT_reg_val_ts See section 5.1.1. below. ncibasevalues01 SNVT_reg_val raw: -2147483648 to 2147483647 unit: reg_val_unit_t enumeration type nr_decimals: 0,..,7 nvoregvals02 SNVT_reg_val_ts See section 5.1.1. below. History value of register object, for readout of Load Profile data. Not in use. Current value of register object. History value select, for request of Load Profile data. History value of register object, for readout of Load Profile data. Not in use. Current value of register object. Page 7 of 15

nvihisttimes02 SNVT_time_stamp year: 0,..,3000 (AD) month: 0,..,.12 day: 0,..,31 hour: 0,..,23 minute: 0,..,59 second: 0,..,59 nvohistvals02 SNVT_reg_val_ts See section 5.1.1. below. ncibasevalues02 SNVT_reg_val raw: -2147483648 to 2147483647 unit: reg_val_unit_t enumeration type nr_decimals: 0,..,7 nvioutputstate SNVT_switch Value: 0,5 - Output 1 1,0 - Output 2 1,5 - Output 3 2,0 - Output 4 State: 0 - turn OFF History value select, for request of Load Profile data. History value of register object, for readout of Load Profile data. Not in use. To control the output/s and there state. 1 - turn ON nvometerid SNVT_str_asc ascii[31], each 0..255 Serial number of the Electricity Meter. Page 8 of 15

5.1.1 SNVT_REG_VAL_TS The below table describes the SNVT type of SNVT_reg_val_ts of the ABB LonWorks PLC adapter. Field Valid Range Comments raw -2147483648 to 2147483647 unit Enumeration type Where unit is the unit of the quantity. RVU_unit nr_decimals 0,..,7 Number of decimals. Status 0,..,15 0x01 Time has been changed during the measuring period and the change exceeds the error limit, or time is invalid time. 0x02 0x03 Internal/External error during the measuring period; for example: - watchdog reset. - error in EEPROM operation. - memory checksum error. - polling error from the external device. - register overflow or underflow (with subtracting pulse inputs) during the measuring period. Power failure during the measuring period. 0x04 Illegal value request: - uninitiated after boot up. - nvihistchoice or nvihisttime out of range (input values out of range). reg_state 0,1 Register State: 0 = Register is deactivated. Object does not measure into the register. 1 = Register is activated. Object measures into the register. Page 9 of 15

5.1.2 STATUS OF OBJECTS The table below describes the network variable nvostatus flags of the ABB LonWorks PLC adapter. Please note that the error/s in nvostatus will automatically be cleared when the error is taken care of, however clearing of errors in nvostatus can also be done manually by sending an nvirequest of RQ_CLEAR_STATUS to the adapter. Field Valid Comments Range Object ID 0,..,8 ID of object with in node, always 0 in ABB LonWorks PLC adapter. Invalid ID 0, 1 1 means requested ID is not implemented in this node. Invalid request 0, 1 1 means request for unimplemented function. Disabled 0, 1 1 means object disabled. Out of limits 0, 1 1 means object exceeded alarm limits. Open circuit 0, 1 1 means phase error detected. Out of service 0, 1 1 means watchdog bitten, power cut length > 2 days, CRC fault. Mechanical fault 0, 1 Not in use. Feedback failure 0, 1 Not in use. Over range 0, 1 1 means the value of register object is over range. Under range 0, 1 Not in use. Electrical fault 0, 1 1 means EEPROM fault, RTC read/write fault. Unable to measure 0, 1 Not in use. Communication failure 0, 1 Communication failure Fail self test 0, 1 Not in use. Self test in progress 0, 1 Not in use. Locked out 0, 1 Not in use. Manual control 0, 1 Not in use. In alarm 0, 1 1 means object is in alarm. In override 0, 1 Not in use. Report mask 0, 1 1 means status is an event mask. Programming mode 0, 1 Not in use. Programming fail 0, 1 Not in use. Unsigned alarm notify 0, 1 Not in use. Reset complete 0, 1 Not in use. Page 10 of 15

5.1.3 ALARM OF OBJECTS The table below describes the network variable nvoalarm flags of the ABB LonWorks PLC adapter. Please note that alarms which has been set in the fields of Value [0] and Value[1] will not be automatically cleared even though the error/s has been taken care of, in order to clear these an nvirequest of RQ_CLEAR_ALARM has to be sent to the adapter. Field Valid Range Comments Location 6 Bytes Location of node zone number, description of characters used for location of the device. Object ID 2 Bytes ID of object with in node, always 0 in ABB LonWorks PLC adapter. Alarm type 1 In alarm case always 1. Priority level 0,..,3 Priority level of alarm. Index to SNVT 2 Bytes Index of NV on the device. Value [0], bit 0 0, 1 EEPROM fault Value [0], bit 1 0 DELTAsingle: RTC Error. Value [0], bit 2 0 Not in use. Value [0], bit 3 0 Not in use. Value [0], bit 4 0, 1 EEPROM CRC fault Value [0], bit 5 0 Not in use. Value [0], bit 6 0 DELTAsingle: External data input signal out of specification. Value [0], bit 7 0 Not in use. Value [1], bit 0 0, 1 Communication error. Value [1], bit 1 0, 1 Meter changed. Value [1], bit 2 0 Not in use. Value [1], bit 3 0 Not in use. Value [1], bit 4 0 Not in use. Value [1], bit 5 0 Not in use. Value [1], bit 6 0 Not in use. Value [1], bit 7 0 Not in use. Value [2], bit 0 0 Not in use. Value [2], bit 1 0, 1 Phase error. Value [2], bit 2 0, 1 Overvoltage 10%. Value [2], bit 3 0, 1 Undervoltage 10%. Value [2], bit 4 0 Not in use. Value [2], bit 5 0, 1 Wrong rotation. Value [2], bit 6 0, 1 Wrong current direction. Value [2], bit 7 0 Not in use. Value [3], bit 0 0 Not in use. Value [3], bit 1 0 Not in use. Value [3], bit 2 0 Not in use. Value [3], bit 3 0 Not in use. Value [3], bit 4 0 Not in use. Value [3], bit 5 0 Not in use. Value [3], bit 6 0 Not in use. Value [3], bit 7 0 Not in use. Year 0,..,3000 (AD) Not in use. Month 0,..,12 Not in use. Day 0,..,31 Not in use. Hour 0,..,23 Not in use. Minute 0,..,59 Not in use. Second 0,..,59 Not in use. Millisecond 0,..,999 Not in use. Alarm limit 4 Bytes Alarm limit, Always 0 Page 11 of 15

5.1.4 LOAD PROFILE READING The SCA supports load profile reading of ABB electricity meters with the load profile feature. Since load profile reading involves treatment of large amount of data, the ABB LonWorks PLC adapter cache the load profile for the last quantity that has been requested. The below scheme describes how to get the fastest possible reading time when reading load profile data. 1. Request and readout all desired load profile data for one quantity before reading another quantity. 2. Request and readout the load profile data with forward incremented time, e.g. 00:00, 01:00, 02:00, when 60 minutes of interval for the load profile are used. 5.2 EXPLICIT MESSAGES Explicit messages are supported by the ABB LonWorks PLC adapter for request and readout of Event log data. This is described by the tables below. Request of Event log using explicit messages. Field Type/Length Comment Message Code Byte Quality log code (0x4C) Time_Stamp_req SNVT_time_stamp (= 7 Bytes) Time from where to search log entries (year, month, day, hour, minute, second): entry having nearest starting time is written first in the response buffer and then other values (see next table:response) Offset 2 Bytes Offset to entry from time stamp. Readout of Event log using explicit messages. Field Type/Length Comment Message Code Byte Quality log code (0x4C) Control Byte 0x01 = Message OK. For example (assuming three entries per message): -10 = tenth, eleventh and twelfth entry before given time. -1 = three nearest before given time. 0 = three nearest after given time. 0x02 = Error (too long response message); time stamp, length and status bytes not send. 0x03 = No log item(s) after (positive offset) or before (negative offset) requested time. Time Stamp 1 SNVT_time_stamp (= 7 Bytes) Starting time for nearest entry that matches request (year, month, day, hour, minute, second). Length 1 4 Bytes Duration of occurrence in seconds. Status 1 1 Byte Message type: 0 = Value not available 1 = Power cut. 2 = Phase 1 error. 3 = Phase 2 error. Page 12 of 15

4 = Phase 3 error. 5 = Overvoltage +6% phase 1. 6 = Overvoltage +6% phase 2. 7 = Overvoltage +6% phase 3. 8 = Undervoltage -10% phase 1. 9 = Undervoltage -10% phase 2. 10 = Undervoltage -10% phase 3. 11 = Undervoltage -15% phase 1. 12 = Undervoltage -15% phase 2. 13 = Undervoltage -15% phase 3. 14 = Wrong rotation. 15 = Wrong current direction. Time Stamp 2 SNVT_time_stamp Time stamp for the second Event log entry with the same format as Time Stamp 1. Length 2 4 Bytes Length for the second Event log entry with the same format as Length 1. Status 2 1 Byte Status for the second Event log entry with the same format as Status 1. Time Stamp n SNVT_time_stamp Time stamp for the nth Event log entry with the same format as Time Stamp 1. Length n 4 Bytes Length for the nth Event log entry with the same format as Length 1. Status n 1 byte Status for the nth Event log entry with the same format as Status 1. Note: The total message length is maximum 38 bytes including message code. Page 13 of 15

6 ABBREVIATIONS AND ACRONYMS Explicit message A message triggered explicitly by a NEURON or host application, whose content and time of transmission are defined by the application code. LNS Acronym for LONWORKS Network Services. LON Local Operating Network. LONMARK LONMARK Association: An independent organization of LONWORKS developers, system integrators, and end-users that define standards to ensure interoperability between LONWORKS devices from multiple manufacturers. LONWORKS Local Operations Network: A set of tools and devices forming a control network. LonTalk The protocol used on LONWORKS networks that standardizes communication. It defines the standard under which individual nodes exchange information. LONWORKS NV A network variable created using LonMaker for open LONMARK interoperability within the given application. In contrast to LONWORKS NVs, there are also NVs for communicating with the Distributed I/O Modules via autobinding. NEURON Chip A term derived from neuron (the cell) for an integrated circuit that contains a LON interface and permits the implementation of an application. NeuronID A 48-bit long identification number for each NEURON chip, burned in during its manufacture. NV Acronym for Network Variable on a LONWORKS system: NVs are high-level data objects that LONWORKS application nodes use to communicate with one another. The types, functions, and number of NVs are determined by the application code within the node. SNVT Acronym for Standard Network Variable Type. SNVTs facilitate interoperability by providing a well-defined interface for communication between nodes. UNVT Acronym for User-Defined Network Variable Type. UNVTs are application-specific Network Variable Types and are thus not SNVTs. XIF Acronym for External Interface File. Page 14 of 15

7 INDEX A A-band...6 C C-band...6 D DIN EN 50090-2-2...5 E Error/Information flags...10 Explicit messages...6, 12 Request of Quality Logs...12 H Humidity...5 I Infra-red communication port...3 N Node Object...6 O Overload protection...3 S SCA parts...3 Service LED...3, 4 Service pin...3 SNVT Type...6 Standards...5 T Temperature...5 Type designation...4 U Utility Data Logger registers...6 Page 15 of 15