File E Page T1-1 of 2 Issued:

Similar documents
C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

File E Project 91SC COMPONENT POWER SUPPLIES INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

E A54-UL 2012-AUGUST-29 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

File E Project 93ME39941, Issued: November 29, 1993 New: April 26, 2006 REPORT COMPONENT - POWER SUPPLIES. For Use In

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

File E Project 07SC April 8, 2008 REPORT COMPONENT TEMPERATURE INDICATING AND REGULATING EQUIPMENT

UL TEST REPORT AND PROCEDURE

File E Project 01ME October 15, 2001 REPORT

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

C E R T I F I C A T E O F C O M P L I A N C E

CERTIFICATE OF COMPLIANCE

Procedure And/Or Report Material

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

File E28476 Project 01ME June 27, 2001 REPORT COMPONENT - CONNECTORS FOR USE IN DATA, SIGNAL, CONTROL AND POWER APPLICATIONS

File E Project 90ME March 12, 1991 REPORT

File E Project 98ME March 9, 1998 REPORT

UL TEST REPORT AND PROCEDURE

File E Project 03ME March 01, 2004 REPORT COMPONENT - NON-OPTICAL ISOLATORS. Analog Devices Inc Wilmington, MA

File E Project 89ME November 30, 1989 REPORT COMPONENT - POWER SUPPLY. Vicor Corp. Andover, MA

File E Project 03ME REPORT COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

File E Project 11SC May 15, 2012 REPORT COMPONENT DRIVERS FOR LIGHT-EMITTING-DIODE ARRAYS, MODULES AND CONTROLLERS

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

Page 1 of 2. Power Supply SL POWER ELECTRONICS CORP 6050 KING DRIVE, BLDG A VENTURA CA 93003, USA

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

ISAFJORDSGATAN 16B SE STOCKHOLM SWEDEN

CERTIFICATE OF COMPLIANCE

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

CERTIFICATE OF COMPLIANCE

UL TEST REPORT AND PROCEDURE

File E Project 00SC September 27, 2000 REPORT COMPONENT - POWER SUPPLIES, MEDICAL AND DENTAL EQUIPMENT

COVER PAGE FOR TEST REPORT

File E Project 03ME Issued: March 4, 2004 REPORT COMPONENT - POWER SUPPLIES, SPECIALTY - COMPONENT

File E Project 91SC Issued: July 4, 1991 Revised: August 23, 2007 REPORT

File E Vol. 1 Sec. 35 *Page 1 Issued: and Report Revised:

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

NOTICE OF COMPLETION AND AUTHORIZATION TO APPLY THE UL MARK

CERTIFICATE OF COMPLIANCE

Page 1 of 2. Component - Power Supply SL POWER ELECTRONICS CORP 6050 KING DR. BLDG A VENTURA, CA 93003, USA

Governing Standards. All wiring and components shall meet the applicable requirements of the NEC.

File E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany

Certificate of Compliance

CERTIFICATE OF COMPLIANCE

Certificate of Compliance

File E90700 Vol 3 Issued: Revised: SEE ADDENDUM FOR MANUFACTURING LOCATIONS

SFY Functional Safety Frequency-to-DC Transmitter with Display

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

File E Project 98NK15665A. Issued January 26, 1999 Revised December 21, 2016 REPORT

Universal Tablet Enclosure 13 Inch and Under for Microsoft Surface Pro 3 and 4 PN MSPRO4

UL TEST REPORT AND PROCEDURE

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Principal LED Street Stik Fluorescent Bulb Replacements

Special-Purpose Proximity Sensor E2C

BSPD Surge Protective Devices

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Product Guide Specification

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

Page 1 of 2. Component - Power Supply SL POWER ELECTRONICS CORP BLDG A, 6050 KING ST VENTURA CA 93003, USA

Circuit Breaker Analyzer & Timer CAT31

Certificate of Compliance

S-series Horizontal Carriers

Programmable Controller IC697ACC721/724/744

Industrial Monitors and Touch Monitors

Listing Constructional Data Report (CDR)

C E R T I F I C A T E O F C O M P L I A N C E

D10CC150HV10F. HRV ( V) Dimmable LED Driver 1050mA, Constant Current Output 0 10V Dimming to 10% Thermal Foldback Control.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

2U/3U Redundant Power Supply. 400W for IPC-Computer

Type NT and Type ZWM Terminal Blocks

Principal LED Qwik Stik Fluorescent Bulb Replacements

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Cert.Record No _0_000, Class No , DQD No 557 Rev SUPPLEMENTARY PROTECTORS COMPONENT ACCEPTANCE PROGRAM

Transcription:

File E318630 Page T1-1 of 2 Issued: 2010-05-13 TEST RECORD NO. 1 Samples of the Model Number HIS-WL followed by 15-, 17-, 19- followed by any two alphanumeric suffixes followed by A or B, followed by any alphanumeric suffix and Accessories for use with HIS-WL Series for Suffix V, A and B Model CP-BLNK-BLK, CP-CON-BLK, CP-GL, CP-PG-BLK, and CP-RG1-BLK and Accessories for use with HIS-WL Series for Suffix V, A and B Model CP-BLNK- SS, CP-CON-SS, CP-PG-SS and CP-RG1-SS. as indicated below and constructed as described herein, were submitted by the manufacturer for examination and test. The Model No. HIS-WL19 was used for test purposes and was considered representative of both the HIS-WL15 and HIS-WL17. Test results relate only to the items tested. Due to the similarity of these devices to Models HIS-ML Listed previously by this manufacturer, only limited tests were considered necessary Test Model Report Date File Reference Test Record No. All HIS-ML21 208-05-07 E318630 1-3 The following tests were conducted. Test Reference DRIP TEST UL 50E 1 st Edition, issued September 4th, 2007 Sec. 8.2 HOSEDOWN TEST UL 50E 1 st Edition, issued September 4th, 2007 Sec. 8.6 ULTRAVIOLET LIGHT EXPOSURE TEST UL 746 C 6 th Edition, revised September 10 th, 2004 Sec. 59 The following tests were conducted in accordance with UL508 and are considered representative of the same tests required by Canadian National Standard, CAN/CSA C22.2 No. 142-2004. The test methods and results of the above tests have been reviewed and found to comply with the requirements in the Standard for Industrial Control Equipment, UL 508, 17 th Edition, issued January 28th, 1999, revised April 15 th, 2010.

File E318630 Page T1-2 of 2 Issued: 2010-05-13 The results of this investigation, including construction review and testing, indicate that the products evaluated comply with the applicable requirements in UL508 The Standard for Industrial Control Equipment, 17 th Edition, revised 2010/04/15 as well as CSA C22.2 No 142-2004 and, therefore, such products are judged eligible to bear UL's Mark as described on the Conclusion Page of this Report. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL.

File E318630 Page T2-1 of 2 Issued: 2010-05-13 New: 2011-01-14 TEST RECORD NO. 2 A sample of the Model Number HIS-WL followed by 19- or 22- followed by any two alphanumeric suffixes followed by A or B, followed by any alphanumeric suffix and Models KVM2EXT-BLK-N4 and KVM2EXT-SS-N4X as indicated below and constructed as described herein, was submitted by the manufacturer for examination and test. ALTERNATE COMPONENT: LCD Monitor - (Model Number HIS-WL19 only) - Listed (NWGQ/7) Model No. E1910TW, rated 100-240 VAC, 0.8 A, manufactured by LG Electronics. Alternate (Model Number HIS-ML19 only) Listed (NWGQ/7) Model No. VS13642, rated 100-240 VAC, 1.5 A, manufactured by Viewsonic. Test results relate only to the items tested. Due to the similarity of these devices to Models HIS-ML Listed previously by this manufacturer, only limited tests were considered necessary Test Model Report Date File Reference Test Record No. All HIS-ML21 2008-05-07 E318630 1-3 The following tests were conducted. Test Reference HOSEDOWN TEST UL 50E 1 st Edition, issued September 4th, 2007 Sec. 8.6 The following tests were conducted in accordance with UL508 and are considered representative of the same tests required by Canadian National Standard, CAN/CSA C22.2 No. 142-2004. The test methods and results of the above tests have been reviewed and found to comply with the requirements in the Standard for Industrial Control Equipment, UL 508, 17 th Edition, issued January 28th, 1999, revised April 15 th, 2010.

File E318630 Page T2-2 of 2 Issued: 2010-05-13 New: 2011-01-14 The results of this investigation indicate that the products evaluated comply with the applicable requirements in UL 508, Standard for Industrial Control Equipment, 17 th Edition, Revision Date 2010-04-15, and CSA C22.2 No. 142, Process Control Equipment, reaffirmed 2004, and, therefore, such products are judged eligible to bear UL s Mark as described on the Conclusion Page of this Report. Reviewed by: Daniel S. Wong Project Engineer John J. Carrigan Staff Engineer Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL.

File E318630 Page T3-1 of 1 Issued: 2010-05-13 New: 2012-02-15 TEST RECORD NO. 3 A representative production line samples of the Industrial Monitors as indicated below and constructed as described herein, was submitted by the manufacturer for examination. New Models for Accessories for use with HIS-WL Series for Suffix V, A and B as indicated below: CP-RG2-BLK, CP-RG2-SS, KVM2EXT-BLK-N4-PS2, KVM2EXT-BLK-N4-USB, KVM2EXT- SS-N4X-PS2, KVM-SS-N4X-USB. Nomenclature Breakdown: KVM2EXT-(a)-(b)-(c) a SS for stainless steel enclosure BLK for black powder coat carbon steel enclosure b N4X for Type 12/4/4X N4 for Type 12.4 c PS2 for serial kvm extender USB for USB kvm extender No additional testing was deemed necessary to add the above mentioned alternate model numbers as they are identical to existing models except for insignificant suffixes changes. The results of this investigation indicate that the products evaluated comply with the applicable requirements of the Standard for Industrial Control Equipment, UL508 17th edition, revised April 15, 2010, and Process Control equipment, Industrial Products, CSA C22.2 No. 142-M1987, (Reaffirmed 2009) and, therefore, such products are judged eligible to bear UL s Mark as described on the Conclusion Page of this Report. Karl Moeller Senior Project Engineer Reviewed by: Ryan Bridgemohansingh Staff Engineer Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories LLC (UL) or any authorized licensee of UL.

File E318630 Page T4-1 of 2 Issued: 2010-05-13 New: 2012-10-04 TEST RECORD NO. 4 A representative production line samples of the Industrial Monitors as indicated below and constructed as described herein, was submitted by the manufacturer for examination. Change 1: New Model HIS-WL23, 90-264 VAC, 0.6 A-0.25 A, 63-47 Hz or 12Vdc/3.3 A or 24Vdc/1.7 A, employing Listed (NWGQ/7) Model No. VS14822, rated 12-24 Vdc, 2.1 A, mfr d by Viewsonic. For unit which is rated 100-240 V a power supply is employed as follows: R/C (QQGQ2/8) rated 90-264Vac, 0.8A/0.56A, 44.4W, mfr by Mean Well(E183223), Cat. No. PS-45-12 or R/C (QQGQ2/8), rated 90-264Vac, 60W,mfr by Cincon, Cat. No. CFM60S120. Change 2: Alternate (For all 17 inch versions) Listed (NWGQ/7) Model No. VS14863 or VS14814, rated 100-240 V, 50/60Hz, 1.5 A, mfr d by Viewsonic. Change 3: (NWGQ/7) Viewsonic. Alternate (Model Number HIS-WL22 only) Listed Model No. VS14517, rated 100-240 Vac, 1.5 A, mfr d by Due to the similarity of these devices being previously evaluated under Test Records No. 1 to 3 and suitable ratings and evaluation of the alternate components, no additional evaluation was deemed necessary to process these changes. No additional environmental testing was deemed necessary on the Model HIS-WL23 based upon the rear cover screw spacing of the Model HIS-WL19 2-1/8 in and HIS-WL22 3-9/16 in as compared to the lesser rear cover screw spacing of the Model HIS-WL23 3-5/16 in and based upon the Hose Down Testing conducted on the Model HIS-WL19 under Test Record No. 1 and Model HIS-WL22 under Test Record No. 2 of this Report.

File E318630 Page T4-2 of 2 Issued: 2010-05-13 New: 2012-10-04 The results of this investigation indicate that the products evaluated comply with the applicable requirements of the Standard for Industrial Control Equipment, UL508 17th edition, revised April 15, 2010, and Process Control equipment, Industrial Products, CSA C22.2 No. 142-M1987, (Reaffirmed 2009) and, therefore, such products are judged eligible to bear UL s Mark as described on the Conclusion Page of this Report. Karl Moeller Senior Project Engineer Reviewed by: Lenworth E. Grant Senior Staff Engineer Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories LLC (UL) or any authorized licensee of UL.

File E318630 Page T5-1 of 1 Issued: 2010-05-13 New: 2012-12-28 TEST RECORD NO. 5 A representative production line samples of the Industrial Monitors as indicated below and constructed as described herein, was submitted by the manufacturer for examination. Alternate Monitor (For all 19 inch versions) Listed (NWGQ/7) Model No. VS15103, rated 100-240Vac, 50/60 Hz, 1.5 A, mfr d by Viewsonic. Due to the similarity of these devices being previously evaluated under Test Records No. 1 to 3, suitable ratings and evaluation of the alternate components, no additional evaluation was deemed necessary to process these changes. The results of this investigation indicate that the products evaluated comply with the applicable requirements of the Standard for Industrial Control Equipment, UL508 17th edition, revised April 15, 2010, and Process Control equipment, Industrial Products, CSA C22.2 No. 142-M1987, (Reaffirmed 2009) and, therefore, such products are judged eligible to bear UL s Mark as described on the Conclusion Page of this Report. Karl Moeller Senior Project Engineer Reviewed by: Lenworth E. Grant Senior Staff Engineer Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories LLC (UL) or any authorized licensee of UL.

File E318630 Page T6-1 of 1 Issued: 2010-05-13 New: 2013-04-16 TEST RECORD NO. 6 No samples were required for adding DC-DC converters to programmable controller modules, Models HIS-WL19 and HIS-WL23. Change 1: For programmable controller modules, Models HIS-WL19 and HIS- WL23, DC-DC converters are employed as following: For unit rated 9.6-36.6 Vdc, a DC-DC converter is employed as follows: R/C (QQGQ2/8), Delta Electronics Inc., (E131881), Model S24SE12003, rated input 9.6-36.6 Vdc, 4.9 A; output 12 Vdc, 2.5 A. Test results relate only to the items tested. Due to the similarity of these devices being previously evaluated and suitable ratings, no additional evaluation was deemed necessary to process these changes. Tests were considered covered as follows: Model Test File Report Date Test Record No(s). HIS-WL19 ALL E318630 2010-05-13 1, 2, 3, 5 HIS-WL23 ALL E318630 2010-05-13 3, 4 The test methods and results of the above tests have been reviewed and found to comply with the requirements in the Standard for Industrial Control Equipment, UL 508, 17th Edition, revised March 15, 2013 and Canadian Standard for Process Control Equipment, CSA C22.2 No. 142-M1987, Third Edition, Reaffirmed 2009. The results of this investigation indicate that the products evaluated comply with the applicable requirements of UL 508, Standard for Industrial Control Equipment, 17 th Edition, revised March 15, 2013, and CSA C22.2 No. 142, Process Control Equipment, reaffirmed 2009 and, therefore, such products are judged eligible to bear UL s Mark as described on the Conclusion Page of this Report. TJ Cheng Project Engineer Any information and documentation involving UL Mark services are provided on behalf of UL LLC, (UL) or any authorized licensee of UL.

File E318630 Page C1 Issued: 2010-05-13 CONCLUSION Samples of the products covered by this Report have been found to comply with the requirements covering the class and the products are judged to be eligible for Listing and Follow-Up Service. Under the service the manufacturer is authorized to use the Laboratories Mark on such products which comply with the Follow-Up Service Procedure and any other applicable requirements of Underwriters Laboratories Inc. Only the products which properly bear the Laboratories Mark are considered as Listed by Underwriters Laboratories Inc. Reviewed by: Daniel S. Wong Project Engineer Conformity assessment Services Len Grant Engineer Sr. Staff Conformity Assessment Services Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL.