MINISTACK Fuse Switch Disconnector Units

Similar documents
the Santon FCS-type switch Disconnect Superior Switch Solutions

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

SIRCO Load break switches for power distribution from 125 to 5000 A

Switch Disconnectors, Main and EMERGENCY-STOP Switches

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Make the Switch. Your Specialist in CONTROL SOLUTIONS SPEEDY BUILD. AC Isolators/Switch Fuses/Changeover Switches SURFACE & PANEL MOUNT (20A A)

MNS ACS880 Switchgear mounted industrial drives

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

MMLG 01, 02, 03, 04 MMLB01

Adaptors Busplug Low Voltage Switchboard Equipment

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Conveyor Belt Alignment Switches from IDEM

Medium voltage switchgear With fixed pattern circuit breaker GenieEvo

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

Innovation on Medium Voltage Switchgear

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Build electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A

Air & Moulded Case Circuit Breaker Service & Maintenance

KMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available

MOTOR PROTECTION CIRCUIT BREAKERS

Dorman Smith Loadbank 125 MCCB Panel Boards

Magnetic and Hydraulic-Magnetic Circuit Breaker

Jtec 10kA Miniature Circuit Breaker

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

High Safety low voltage switchgears For maximum requirements far beyond all standards.

Thermal-Magnetic Circuit Breaker 2216-S

Magnetically Actuated Safety Interlock Switches

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

Product Specification

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

IEC & 2 standard. The reference for safe and reliable LV switchboards

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

SECTION SWITCHBOARDS

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

Technical data sheets

Air Circuit Breakers. 1/2 Introduction

TeSys contactors From 115 to 2750 A

AB MSAI Research Labs Pvt. Ltd., 201, IInd Floor, Aggarwal Cyber Plaza, Netaji Subhash Place, Pitampura, Delhi

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

ENGINEERING SPECIFICATION 90 WATT POWER SUPPLY PART NUMBER PA P1

PERFORMANCE SPECIFICATION

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

E-STOP relay, safety gate monitor

Voltage Dip-Proofing Inverter

Safe monitoring relays

White Paper. UL Standards for Power Control System Equipment

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Switch-disconnectors OTDC and OTDCP Switches for photovoltaic applications

SIGUARD Safety Systems Safety Integrated

SACE Emax 2 Specification guide

Siemens AG 2016 SENTRON. 3KC Transfer Switching Equipment up to 3200 A. Edition 10/2016. siemens.com/lowvoltage

Air-insulated medium-voltage secondary distribution switchgear

Thermal-Magnetic Circuit Breaker 4220-T...

Safe timer relay/contact expansion modules

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

AC Capacitors for HID Lighting Applications

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

AIR COOLED MODULAR RECTIFIER

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

GE Energy Connections Grid Solutions MMLZ. Technical Data Sheet Auxiliary Modules. Publication reference: MMLZ/EN TDS/B

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Non-Fusible Disconnect Switches

PRODUCT SPECIFCATION GS MINI-SAS HD External Cable to Board Connector System. 1 of 14 F. Roger Cheng TYPE NUMBER

Redundancy Module QUINT-DIODE/40

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

SolConeX Wall-Mounted Socket, 16 A

E-STOP relays, safety gate monitors

Low Voltage Catalogue Prisma G. Wall-mounted and floor standing enclosures for Electrical Distribution up to 630 A

3 Pole Contactors with AC operating coils

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Time Delay Values (E-Series)

PRODUCT SPECIFICATION

Alpha. Pendant control station. business partner. Features. Design. Materials. Industrial lifting. Construction lifting.

RATINGS AND SPECIFICATIONS

PRODUCT SPECIFICATION

Voltage Dip-Proofing Inverter

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

Operating Instructions Electronic Circuit Protector ESX10-TC-DC 12 V

Motor protection relays

NeXLev Product Specification TB2144

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Air Circuit Breaker (ACB)

Transcription:

MINISTACK Fuse Switch Disconnector Units

Contents Introduction 3 Range 3 Ordering details 5-6 Dimensions 7-21 Operation and Maintenance Procedure 22 Technical and Performance Data 23 2

Ministacks ALSTOM Industrial Products Division is continually developing the Ministack range of switches to provide for the requirements of consulting engineers, contractors and switchboard builders. The latest range of Ministacks include: Uprated busbar (910A) for 100A & 200A stacks, 2 to 10 high. New style sandwiched copper cable connectors fitted to the rear moulding of 100A & 200A units. 3&4 high 400A & 630A Ministacks. NEW comprehensive range of mixed stacks. The Ministack now offers industry a clear choice in low voltage switchboard design. This design suits Form 1 to Form 4 types of separation. With the addition of optional terminal shrouds plus the necessary barriers provided by the switchboard builder, Form 4 separation is achievable. Fuse switch disconnector units are available which have been successfully tested, and meet the requirements of the standard test as indicated by Clause EE3 in Appendix EE of AS3439.1 or special test as specified in Clause EE6 of Appendix EE. The fuse switch disconnectors are defined as follows: CMS Standard types which have been tested with the arc being initiated on the load side terminals. CMSE Special types tested where the arc was initiated within the fuse switch disconnectors and substantial 3-phase arcing currents were not interrupted by the fuse links for the full duration of test time nominated. Service Requirements and Temperature Rise Guidelines (CL.6.1.1) AS3947.1 Under normal service conditions as defined in AS3947-1 (i.e. The ambient air temperature does not exceed +40 C and its average over a period of 24 hrs does not exceed +35 C ), individual switch units in a stack are fully rated. Derating is however necessary when switch ratings exceed the assigned main busbar rating. Load diversity to be taken into account. For reliable operation, regular maintenance is required. Refer page 22. CMS CMSE Range: Main Busbar Incomer Direction Switch Rating Amps Outgoing Terminal Connection Types Height of Stack Above Below Above & Below Busbar Rating Amps 100 & 200 Front Connected Right Hand 2-10H Above Below Above & Below 910 Front Connected Left Hand Back Connected 400 & 630 Front Connected Right Hand 2-4H Above Below Above & Below 1000 Front Connected Left Hand Back Connected 800 Front Connected Right Hand 1&2H Above Below Above & Below 1000 Front Connected Left Hand Back Connected Mixed Stacks Front Connected Right Hand See page 4 Above Below Above or Below 1000/910 Front Connected Left Hand Back Connected 3

New Mixed Stacks Mixed Stacks are now available in standard configurations up to 9 high, by combining 100A up to 800A switch disconnector CMS/CMSE units. The following table lists the standard configurations available. Mixed Stack Configuration Large Switch Disconnector Small Switch Disconnector 400A, 630A or 800A 100A or 200A or Future Space for 400A/630A or Future Space for 100A/200A CMS/CMSE Unit CMS/CMSE Unit Quantity per Stack Quantity per Stack 1 x 400A/630A or Future 400A/630A plus 1 up to 8 of above 1 x 800A plus 1 up to 6 of above 2 x 400A/630A or Future 400A/630A plus 1 up to 6 of above 3 x 400A/630A or Future 400A/630A plus 1 up to 3 of above 2 x 400A/630A or Future 400A/630A plus 1 x 800A 2 x 800A Accessories Key Interlocks: Auxiliary Contacts: Terminal Shrouds: Castell, Lowe & Fletcher Up to 2 C/O contacts per switch 2 part terminal shrouds to suit all switches Notes 1. CMSE Appendix EE Ministacks supplied less in-fill panels, refer data sheet page 11. 2. Doors supplied loose unpainted c/w accessories and fasteners or switch doors are available fitted and painted. 4

Ministack Quotation Ordering Details 1. Draw switch layout in space provided or attach drawings. Note: Space for Future units, write as (FUT.1/200A) or (FUT.4/630A) Above 100 EXAMPLE 2. Show incomer positions of riser busbars, either above, below or above and below. 200A 200A 200 100 200 400A FUT. 1/200A Below F/C LH * * F/C RH 200A B/C For extended 100A/200A F/C load terminals, add letter E, i.e. EXAMPLE 2a. Show position of outgoing terminals, front connected, left hand, right hand or back connected as indicated: E 5

Ministack Quotation Ordering Details (cont.) 3. Tick the required riser busbar short time withstand: 100A & 200A Ministacks 63kA for 1 sec 400A/630A/800A Ministacks 50kA for 3 sec 400A/630A/800A Ministacks 63kA for 1 sec Mixed Stacks 100A to 800A 50kA for 3 sec Mixed Stacks 100A to 800A 63kA for 1 sec 4. Tick the required switch type: CMS (Standard) CMSE (Appendix EE) 5. Tick the required door type: Loose switch doors supplied unpainted or Switch doors painted and fitted Colour N42 Storm Grey AS2700 6. Accessories: Add the following codes to switches as detailed: Dust-proofed CMS units (CMSE IP54 as standard) DP Key Interlocks: Lowe & Fletcher L&F _*_ Castell C_*_ *Add symbol, e.g. L&FA Auxiliary Switches: Auxiliary contacts for 100A/200A switches AUX-C/O Max. No. of contacts = 2 Auxiliary contacts for 400A/630A/800A AUX-C/O Max. No. of contacts = 3 Add No. of contacts to Code, e.g. AUX2C/O Terminal Shrouds (3 Phase Set): 100A - 800A add Code TS Typical example: 200A CMS, dust-proofed c/w 2 aux C/O contacts, Code = 200A DP aux 2C/O TS 6

Dimensions 100A/200A CMS Outline SIDE VIEW SIDE VIEW DETAIL A MAXIMUM VERTICAL BUSBAR CAPACITY 910A PLAN VIEW PLAN VIEW STANDARDS F/C TERMINALS OPTIONAL EXTENDED F/C TERMINALS 7

Dimensions 400A/630A CMS Outline PLAN VIEW SIDE VIEW DETAIL A MAXIMUM VERTICAL BUSBAR CAPACITY 1000A SIDE VIEW 8

Dimensions 100A/200A CMS Cutout & Mounting Dimensions 400A/630A CMS Cutout & Mounting 9

Dimensions 800A CMS Outline DETAIL A MAXIMUM VERTICAL BUSBAR CAPACITY 1000A NOTE: Refer page 8 for dimensions of outgoing terminals SIDE VIEW Dimensions 800A CMS Cutout Details 10

Dimensions Mixed 100A/200A/400A/630A CMS Outline NOTES: 1. Refer pages 7 & 8 for dimensions of outgoing terminals 2. Also available with 100A/200A F/SW at the top and 400A/630A F/SW at bottom, refer to combination table below. 3. NOT SUPPLIED WITH CMSE APPENDIX EE STACKS. SIDE VIEW DETAIL A MAXIMUM VERTICAL BUSBAR CAPACITY 1000A 11

Dimensions Mixed 100A/200A/400A/630A CMS Cutout Details 12

Dimensions Mixed 100A/200A/800A CMS Outline NOTES: 1. Refer pages 7 & 8 for dimensions of outgoing terminals 2. Also available with 100A/200A F/SW at the top and 400A/630A/ 800A F/SW at the bottom, refer to combination table below. 3. NOT SUPPLIED WITH CMSE APPENDIX EE STACKS SIDE VIEW DETAIL A MAXIMUM VERTICAL BUSBAR CAPACITY 1000A 13

Dimensions Mixed 100A/200A/800A CMS Cutout Details 14

Dimensions Mixed 100A/200A/400A/630A/800A CMS Outline NOTES: 1. Refer pages 7 & 8 for dimensions of outgoing terminals 2. Also available with 100A/200A F/SW at the top and 400A/630A/ 800A F/SW at the bottom, refer to combination table below. 3. NOT SUPPLIED WITH CMSE APPENDIX EE STACKS SIDE VIEW DETAIL A MAXIMUM VERTICAL BUSBAR CAPACITY 1000A 15

Dimensions Mixed 100A/200A/400A/630A/800A CMS Cutout Details 16

Dimensions 2H 800A CMS Outline & Cutout Details NOTES: 1. Refer page 8 for dimensions of outgoing terminals 2. Refer page 10 for side view details 3. Refer page 13 for dimesions of incoming terminals 17

Dimensions Mixed 400A/630A/800A CMS Outline & Cutout Details NOTES: 1. Refer page 8 for dimensions of outgoing terminals 2. Refer page 10 for side view details 3. Refer page 13 for dimensions of incoming terminals 18

Arcing Fault Containment Cubicle Construction Guide for 100A/200A CMSE PLAN VIEW DETAIL A NOTES: 1. Refer page 7 for outline dimensions of fuseswitches 2. Use optional F/C extended terminals as required (L/H or R/H sides) (COVERS REMOVED FOR CLARITY) SIDE VIEW SECTION VIEW A A (LEFTHAND CABLE ZONE) SECTION VIEW (RIGHTHAND CABLE ZONE) VENT FLAP DETAIL 19

Arcing Fault Containment Cubicle Construction Guide for 400A/630A/800A CMSE NOTE: Refer pages 8 & 10 for outline dimensions of fuseswitches PLAN VIEW (COVERS REMOVED FOR CLARITY) SIDE VIEW 20

Arcing Fault Containment Cubicle Construction Guide for 400A/630A/800A CMSE SECTION VIEW A A (LEFTHAND CABLE ZONE) SECTION VIEW A A (RIGHTHAND CABLE ZONE) DETAIL A VENT FLAP DETAIL 21

Operating & Maintenance Operation The following information details the correct operating procedure for the standard equipment supplied on a Ministack assembly. Fuse Switches (a) Withdraw the sliding operating handle. (b) Move the handle upwards to the ON position or downwards to the OFF position. Operate the switch handle firmly to its full limit. Carrier Removal/Fuse Replacement Maintenance It is recommended that a six monthly inspection and test be made using the following procedures: Note: If the equipment is operating in a dusty or corrosive atmosphere, this inspection should be made more frequently and appropriate remedial action taken. Fuse Switches (a) Turn switch off. (b) Remove moving carrier from switch. (c) Visually check carrier contact blades for discolouration and arcing damage, replace if excessive. (d) Clean switch blades if necessary and regrease. (e) Ensure all fuse connections are tight to following torque values : 1/200A 8-11 Nm 4/630/800A 12-15 Nm Suggested Specification All fuse switch stacks are to be rated at either 50kA or 63kA and conform to the requirements of AS3439.1. Fuse switch disconnector units shall be rated at 660V AC and 250V DC. All fuse switch stacks shall be provided with an integral fully shrouded riser busbar system, encapsulated within the DMC moulding of the fuse switch disconnector units. The line side connection from the switch to the riser busbar system, shall be of a plug in type. All combination fuse switch units shall be fitted with ASTA20 certified LV HRC fuse links. Fuse switch stacks are to be ALSTOM Ministacks or equivalents. The fitted fuse links are to be GEC, EE or GE Red Spot or equivalents. All future fuse switch disconnector spaces shall be supplied to allow fitting of future switch units at a later date without supply interruptions. To remove the fuse carrier, open the front door, withdraw operating handle and apply sufficient upward pressure to the operating handle to release the interlock while at the same time pulling the fuse carrier outwards in a horizontal direction. DO NOT depress the door safety interlock during this operation. Note: The application of grease should only be made on the lead-in chamfer of the blades. The amount used should not be excessive. Shell LGP1 or Darina R2 grease must be used. DO NOT use vaseline or petroleum jelly. Transport Switch must be transported in ON position. 22

Technical & Performance Data Description CMS100 CMSE100 CMS200 CMSE200 CMS400 CMSE400 CMS630 CMSE630 CMS800 CMSE800 Rated enclosed thermal current Ith 100A 100A 200A 200A 400A 400A 630A 630A 800A 800A (fuse links fitted) Degree of protection, front door & fascia (AS1939) Standard IP42 IP54 IP42 IP54 IP42 IP54 IP42 IP54 IP31 IP52 Dustproofed IP54 IP54 IP54 IP54 IP54 IP54 IP54 IP54 Insulation voltage Ui 415V 415V 415V 415V 415V 415V 415V 415V 415V 415V AC22 Ie @415v 100A 100A 200A 200A 400A 400A 630A 630A 800A 800A AC23 Ie @415v 100A 100A 200A 200A 400A 400A 630A 630A 800A 800A Actual test currents on AC23 @457V 0.35p.f. Make current 800A 800A 1200A 1200A 3200A 3200A 3800A 3800A 4800A 4800A Break current 800A 800A 1200A 1200A 3200A 3200A 3800A 3800A 4800A 4800A Maximum fuse switch capacity L.V fuse link fitted TCP100M200L TCP100M200L TF200M315L TF200M315L TM400M450L TM400M450L TTM630L TTM630L TLM800L TLM800L Motor size HP @ 415V 75 75 150 150 270 270 450 450 570 570 Motor size kw @ 415V 55 55 110 110 200 200 335 335 425 425 Fused short circuit at 440V 80kA 80kA 80kA 80kA 80kA 80kA 80kA 80kA 80kA 80kA Max. peak through peak currents (fuse cut-off) 22kA 22kA 38kA 38kA 42kA 42kA 73kA 73kA 73kA 73kA Standard fused short circuit current at 415V A.C. 80kA 80kA 80kA 80kA 80kA 80kA 80kA 80kA 80kA 80kA DC performance DC23 275V T/C 15 milliseconds 100A 100A 200A 200A 400A 400A 630A 630A 800A 800A Busbar riser rating (enclosed) 910A 910A 910A 910A 1000A 1000A 1000A 1000A 1000A 1000A Busbar riser system rated short time withstand current 63kA rms for 1 second,139 ka peak TCA Test Report No 68409C or 85kA rms for 1 second,187ka peak TCA Test Report No 68551C 50kA rms for 3 second,105 ka peak TCA Test Report No 59340C 63kA rms for 1 second,139 ka peak TCA Test Report No 64178C 63 ka rms for 1 second, 139kA peak TCA Test Report No 64177C Internal arcing fault containment to AS1136-1-1988 Note: Tests performed relate to CMSE switched only 50kA rms for 0.2 second, TCA Test Report 68003 63kA rms for 0.1 second, TCA Test Report 68004 50kA rms for 0.2 second, TCA Test Report 68009 63kA rms for 0.1 second, TCA Test Report 68010 Fuse Link Selection Fuse switch disconnector type CMS & CMSE Rating A TIA2-32# TIS35-63# TB2-63 TBC2-63 TC80&100L TCP80&100L TF125,16&200# TKF250&315# TKM250&315L TM355&400# TTM450-630L TLM670-800L 100 C C 200 C C 400 B B B B 630 B B B B 800 B B B B # Motor rated fuse links also available TIA32M35-63L TIS63M80&100L TCP100,160&200L TF200M2&315L TKF315M355L TM400M450L Fuse link fits direct B designates type B adaptor C designates type C adaptor 23

INDUSTRIAL PRODUCTS 25 Princes Road Regents Park NSW 2143 Tel: 1300 556 601 Fax: 1300 550 187 www.ip.alstom.com.au 8333 TAN 10/02