SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

Similar documents
SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

SR2E121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - no display

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

SR2B121FU. Price* : USD with ladder programming. 80 maat 100 V (without extension)

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261BD modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

SR2A201FU compact smart relay Zelio Logic - 20 I O V AC - no clock - display

SR2D101BD compact smart relay Zelio Logic - 10 I O - 24 V DC - no clock - no display

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

SR3B101BD modular smart relay Zelio Logic - 10 I O - 24 V DC - clock - display

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

SR3XT101BD discrete I/O extension module - 10 I O - 24 V DC - for Zelio Logic

SR3B102BD modular smart relay Zelio Logic - 10 I O - 24 V DC - clock - display

SR2A201BD. Main. <= 0.5 ma for IB...IG used as discrete input circuit. <= 5 Vfor IB...IG used as discrete input circuit V

SR2B122BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

SR2B201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

SR3B261BD modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

SR2B122BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

SR3XT43BD analogue I/O extension module - 4 I O - 24 V DC - for Zelio Logic

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RM35LM33MW liquid level control relay RM35-L V AC/DC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RE9RA21MW7 off-delay timing relay s V AC -

RM4TR31 three-phase network control relay RM4-T - range V

RM4TA32 three-phase network control relay RM4-T - range V

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM35LM33MW liquid level control relay RM35-L V AC/DC

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RMCN22BD Analog Converter ma - for Zelio Analog

RM4JA31M current measurement relay RM4-J - range ma V AC

RM4LA32M liquid level control relay RM4-L V AC

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

TM258LD42DT4L compact base M I/O - 24 V DC

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

TM258LF42DT compact base M I/O - 24 V DC - CANopen

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

K1F006ALH cam switch - 6-pole A - screw mounting

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

XACA2074 pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RM4JA01F current measurement relay RM4-J - range ma V AC

TM3DI16G module TM3-16 inputs spring

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

RM35TF V AC

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

LMC058LF42 compact base - 42 I/O - 24 V DC supply

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

RM4JA32MW current measurement relay RM4-J - range A V AC DC

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

TM3TI4 module TM3-4 inputs temperature

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

TM3SAF. Main. Device short name

ZBRN1. Main. Device short name

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

ABS2EC01EB input interface module mm - solid state - 24 V DC

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

Transcription:

Characteristics modular smart relay Zelio Logic - 26 I O - 100..240 V AC - clock - display Main Range of product Product or component type Zelio Logic Modular smart relay Complementary Local display Number or control scheme lines Cycle time With 120 with ladder programming <= 200 with FBD programming 6...90 ms Backup time 10 years at 25 C Clock drift 6 s/month at 25 C 12 min/year at 0...55 C Checks [Us] rated supply voltage Supply voltage limits Supply frequency Supply current Power consumption in VA Isolation voltage Protection type Discrete input number 16 Discrete input voltage Discrete input current Discrete input frequency Voltage state1 guaranteed Voltage state 0 guaranteed Current state 1 guaranteed Current state 0 guaranteed Input impedance Number of outputs Output voltage limits Contacts type and composition Output thermal current Program memory on each power up 100...240 V 85...264 V 50/60 Hz 80 ma at 100 V (with extensions) 60 ma at 240 V (with extensions) 50 ma at 240 V (without extension) 100 ma at 100 V (without extension) 17 VA with extensions 12 VA without extension 1780 V Against inversion of terminals (control instructions not executed) 100...240 V AC 0.6 ma 47...53 Hz 57...63 Hz >= 79 V for discrete input <= 40 V for discrete input > 0.17 ma for discrete input < 0.5 ma for discrete input 350 kohm (discrete input) 10 relay output(s) 5...30 V DC (relay output) 24...250 V AC NO for relay output 8 A for 8 outputs (relay output) 5 A for 2 outputs (relay output) The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Mar 10, 2015 1

Electrical durability Switching capacity in ma Operating rate in Hz Mechanical durability 500000 cycles DC-13 at 24 V, 0.6 A for relay output conforming to EN/IEC 500000 cycles DC-12 at 24 V, 1.5 A for relay output conforming to EN/IEC 500000 cycles AC-15 at 230 V, 0.9 A for relay output conforming to EN/IEC 500000 cycles AC-12 at 230 V, 1.5 A for relay output conforming to EN/IEC >= 10 ma at 12 V (relay output) 10 Hz (no load) for relay output 0.1 Hz (at Ie) for relay output 10000000 cycles (relay output) [Uimp] rated impulse withstand voltage 4 kv conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock Response time Connections - terminals Tightening torque With 50...255 ms with FBD programming (from state 1 to state 0) for discrete input 50...255 ms with FBD programming (from state 0 to state 1) for discrete input 50 ms with ladder programming (from state 1 to state 0) for discrete input 50 ms with ladder programming (from state 0 to state 1) for discrete input 5 ms (from state 1 to state 0) for relay output 10 ms (from state 0 to state 1) for relay output Screw terminals, clamping capacity: 2 x 0.25...2 x 0.75 mm² AWG 24...18 flexible with cable end Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...16 solid Screw terminals, clamping capacity: 1 x 0.25...1 x 2.5 mm² AWG 24...14 flexible with cable end Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 25...14 solid Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 25...14 semi-solid 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Product weight 0.4 kg Environment Immunity to microbreaks Product certifications Standards <= 10 ms CSA C-Tick GL GOST UL EN/IEC 60068-2-27 Ea EN/IEC 60068-2-6 Fc EN/IEC 61000-4-11 EN/IEC 61000-4-12 EN/IEC 61000-4-2 level 3 EN/IEC 61000-4-3 EN/IEC 61000-4-4 level 3 EN/IEC 61000-4-5 EN/IEC 61000-4-6 level 3 IP degree of protection IP40 (front panel) conforming to IEC 60529 IP20 (terminal block) conforming to IEC 60529 Environmental characteristic Low voltage directive conforming to EN/IEC 61131-2 EMC directive conforming to EN/IEC 61131-2 zone B EMC directive conforming to EN/IEC 61000-6-4 EMC directive conforming to EN/IEC 61000-6-3 EMC directive conforming to EN/IEC 61000-6-2 Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20...55 C conforming to IEC 60068-2-1 and IEC 60068-2-2-20...40 C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 Ambient air temperature for storage -40...70 C Operating altitude Altitude transport Relative humidity 2000 m <= 3048 m 95 % without condensation or dripping water 2

Dimensions Drawings Compact and Modular Smart Relays Mounting on 35 mm/1.38 in. DIN Rail (1) With SR2USB01 or SR2BTC01 Screw Fixing (Retractable Lugs) (1) With SR2USB01 or SR2BTC01 Position of Display 3

Connections and Schema Connection of Smart Relays on AC Supply SR 1B, SR 1FU (1) 1 A quick-blow fuse or circuit-breaker. (2) Fuse or circuit-breaker. (3) Inductive load. (4) Q9 and QA: 5 A (max. current in terminal C: 10 A). With Discrete I/O Extension Module SR3B B + SR3XT B, SR3B FU + SR3XT FU (1) 1 A quick-blow fuse or circuit-breaker. QF and QG: 5 A for SR3XT141 4

Performance Curves Compact and Modular Smart Relays Electrical Durability of Relay Outputs (in millions of operating cycles, conforming to IEC/EN ) AC-12 (1) (1) AC-12: switching resistive loads and opto-coupler isolated solid-state loads, cos 0.9. AC-14 (1) (1) AC-14: switching small electromagnetic loads 72 VA, make: cos = 0.3, break: cos = 0.3. AC-15 (1) (1) AC-15: switching electromagnetic loads 72 VA, make: cos = 0.7, break: cos = 0.4. 5