Dell Force10 S55 and S60 Systems. Quick Start Guide. Regulatory Model: S55/S60

Similar documents
Dell Force10 Z9000 System. Quick Start Guide. Regulatory Model: Z9000

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Dell Networking S4048 Open Networking (ON) Getting Started Guide

Dell Force10 C150 and C300 Systems. Quick Start Guide. Regulatory Model: C150/C300

Dell OptiPlex SFF AIO Stand. User s Guide. Model: IKAIO-01 1 /13

Getting Started Guide

Dell PowerEdge T620 Getting Started Guide

Installing the S4810 System. Publication Date: March 2012

Dell Getting Started Guide for the S6100 ON System March 2016

Quick Start Guide. Dell Force10 E300, E600i, and E1200i Systems

Dell PowerEdge T620 Getting Started Guide

Dell PowerEdge T420 Getting Started Guide

S4112-ON Series. Setup Guide

Dell PowerEdge R720 and R720xd Getting Started Guide

VEP4600. Setup Guide

Dell Networking S5000 Getting Started Guide

Dell PowerVault MD3400/3420/3800i/3820i/ 3800f/3820f Storage Arrays Getting Started Guide

Junos WebApp Secure 5.0 Hardware Guide

Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide

Installing the Z9000 System

Dell Networking S4100-ON Series. Set-Up Guide

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

S5048F-ON. Set-up Guide

Shared LOM support on Modular

Installing the Cisco AS5400XM Universal Gateway

Dell SupportAssist Version 1.2 For Dell OpenManage Essentials Support Matrix

Dell Latitude E6220. Setup And Features Information. About Warnings. Front And Back View

Dell PowerVault Network Attached Storage (NAS) Systems Running Windows Storage Server 2012 Troubleshooting Guide

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for VSP 4850GTS

Dell Networking C9010 Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide

Installing the Cisco Unified Videoconferencing 3545 MCU

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SC7020 Storage Controller Getting Started Guide

Perle SMI Media Converter Installation Guide

LSI SAS i PCIe to 6Gb/s SAS HBA Running On Dell Systems Important Information

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell Optiplex 390. Setup And Features Information. About Warnings. Mini-Tower Front And Back View

Dell Vostro 1310/1510/1710/2510 Setup and Features Information

Dell PowerEdge M905, M805, M605, and M600. Getting Started With Your System

Installing the IPS 4345 and IPS 4360

AI130 AIswitch Series 130 Chassis Installation Guide

Dell Inspiron N5110 Service Manual

Installing the Cisco 2524 and Cisco 2525 Routers

Power Supply Installation

Dell Networking S3100 Series Installation Guide. June 2016

Dell Appliance for Wyse

Installation and Maintenance

TRC-190 User s Manual

TRC-190 User s Manual

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Quick Start Guide S X. 1. Unpacking the Switch. 2. Identifying Your System. Front View

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Configuring Direct-Connect between a DR Series System and Backup Media Server

Power Supply and Fan Module Installation

Dell Vostro 3350/3450/3550/3555/3750

Installing the Cisco SFS 3504 Server Switch

Installing and Managing the Switch

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

Dell XPS 14z Owner s Manual

Dell Server Deployment Pack Version 2.0 for Microsoft System Center Configuration Manager User's Guide

Dell Fabric Manager Deployment Guide 1.0.0

AI180I AIswitch Series 180 Integrated Chassis Installation Guide

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Dell Vostro 320 Setup and Features Information Tech Sheet

Lifecycle Controller with Dell Repository Manager

Using Dell Repository Manager with Dell OpenManage Essentials

Installation. Package Contents CHAPTER

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell SupportAssist Version For Dell OpenManage Essentials Quick Start Guide

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell Reseller Option Kit Important Information

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Installing the Cisco MDS 9020 Fabric Switch

Dell Precision M4600/M6600 Mobile Workstation

Dell Server PRO Management Pack 3.0 for Microsoft System Center Virtual Machine Manager Installation Guide

Catalyst 2360 Switch Getting Started Guide

Dell Latitude E5410/E5510

Dell SC7020 and SC7020F Storage Systems Owner s Manual

CHASSIS-1. Form number 7660

Active Fabric Manager Installation Guide 1.5

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Dell Server PRO Management Pack for Microsoft System Center Virtual Machine Manager Installation Guide

QUICK START GUIDE 7000 SERIES DEVICES. 3D7010/7020/7030 (Chassis: CHRY-1U-AC) 3D7115/7125, AMP7150 (Chassis: GERY-1U-4C8S-AC)

Setting Up Replication between Dell DR Series Deduplication Appliances with NetVault 9.2 as Backup Software

Dell EMC Storage MD1280 Enclosure Owner's Manual

How to Set Up Your SRX4100 Services Gateway

Dell SC460 Expansion Enclosure Getting Started Guide

Dell SupportAssist Version 1.2 For Dell OpenManage Essentials Quick Start Guide

Using Lifecycle Controller to Configure UEFI Secure Boot and OS Deployment

D-Link Switch User Manual. Table of Contents

VEP4600 Installation Guide. July 2018

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

16-SLOT IN-BAND MANAGEMENT CHASSIS

Replacing the Power Supply

Transcription:

Dell Force10 S55 and S60 Systems Quick Start Guide Regulatory Model: S55/S60

Dell Force10 S55 and S60 Systems Quick Start Guide Regulatory Model: S55/S60

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. If you purchased a Dell n Series computer, any references in this publication to Microsoft Windows operating systems are not applicable. Information in this publication is subject to change without notice. 2011 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell, the DELL logo, Dell Precision, OptiPlex, Latitude, PowerEdge, PowerVault, PowerConnect, OpenManage, EqualLogic, KACE, FlexAddress and Vostro are trademarks of Dell Inc. Intel, Pentium, Xeon, Core and Celeron are registered trademarks of Intel Corporation in the U.S. and other countries. AMD is a registered trademark and AMD Opteron, AMD Phenom, and AMD Sempron are trademarks of Advanced Micro Devices, Inc. Microsoft, Windows, Windows Server, MS-DOS and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat Enterprise Linux and Enterprise Linux are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell is a registered trademark and SUSE is a trademark of Novell Inc. in the United States and other countries. Oracle is a registered trademark of Oracle Corporation and/or its affiliates. Citrix, Xen, XenServer and XenMotion are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware, Virtual SMP, vmotion, vcenter, and vsphere are registered trademarks or trademarks of VMWare, Inc. in the United States or other countries. Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. Regulatory Model: S55/S60 2011-9 P/N 045FRK Rev. A00

About this Guide This document is intended as a Quick Start Guide to get new systems up and running and ready for configuration. For complete installation and configuration information, refer to the following documents: Documentation S55 S60 Hardware installation and Installing the S55 System Installing the S60 System power-up instructions Software configuration FTOS Configuration Guide for the S55 System FTOS Configuration Guide for the S60 System Command line interface Latest updates FTOS Command Reference for the S55 System Release Notes for the S55 System FTOS Command Reference for the S60 System Release Notes for the S60 System About this Guide 3

4 About this Guide

1 Installing the Hardware This guide assumes all site preparation has been performed before installing the chassis. Installing the Chassis in a Rack or Cabinet To install the S55 or S60 systems, Dell Force10 recommends that you complete the installation procedures in the order presented below. NOTE: Unless stated otherwise, the installation instructions below apply to both the S55 and S60 chassis. Always handle the system and its components with care. Avoid dropping the switch or its field replaceable units. CAUTION: Always wear an ESD-preventive wrist or heel ground strap when handling the chassis and its components. As with all electrical devices of this type, take all necessary safety precautions to prevent injury when installing this system. Electrostatic discharge (ESD) damage can occur if components are mishandled. Attaching Mounting Brackets The chassis is shipped with mounting brackets (rack ears) and required screws for rack or cabinet installation. The brackets are enclosed in a package with the chassis.. Step NOTE: Dell Force10 recommends attaching the brackets at the PSU side. This provides the greatest weight support for the chassis in the rack or cabinet. Task 1 Take the brackets and screws out of their packaging. Installing the Hardware 5

Step Task 2 Attach the brackets to the sides of the chassis at the PSU end, using four screws for each bracket. Attach the bracket so that the ear faces the PSU and the outside of the chassis. S55 View from Chassis Rear Power Supply/Fan Module Screws Connect to Rack/Cabinet (ears) View from Chassis Front Screws S60 Power Supply/Fan Module Connect to Rack/Cabinet (ears) Power Supply View from chassis rear Connect to rack/cabinet (ear) Screws View of chassis front Power Supply Connect to rack/cabinet (ear) 6 Installing the Hardware

Install Chassis into Rack or Cabinet Ensure that there is adequate clearance surrounding the rack or within the cabinet to permit access and airflow. Step Task 1 Dell Force10 recommends that one person hold the chassis in place while a second person attaches the brackets to the posts. 2 Attach the bracket "ears" to the rack or cabinet posts, using two screws for each bracket. Ensure the screws are tightened firmly. S55 PSU0 PSU1 Rack/Cabinet Post Rack Mounting ears S60 PSU0 PSU1 Rack Mounting "ears" Rack/Cabinet Post Attach a Ground Cable to the System The system is shipped with necessary 10-32 screw(s) for attaching a ground cable to the chassis. The cable itself is not included. Dell Force10 recommends a 6AWG one-hole (for the S55) or two-hole (for the S60) lug, #10 hole size, 63" spacing (not included in shipping) to properly ground the chassis. The lug must be a UL recognized, crimp-type lug. NOTE: The rack installation ears are not suitable for grounding. CAUTION: Grounding conductors must be made of copper. Do not use aluminum conductors. Installing the Hardware 7

NOTE: Coat the one-hole lug with an anti-oxidant compound prior to crimping. Bring any un-plated mating surfaces to a shiny finish, and coat with an anti-oxidant prior to mating. Plated mating surfaces must be clean and free from contamination. Step Task 1 Take the 10-32 screw(s) from the package. 2 Cut cable to desired length. Cable length must facilitate the proper operation of fault interrupt circuits. Dell Force10 recommends using of the shortest cable route allowable. 3 Attach the lug to the chassis as shown, using the supplied 10-32 screw(s) with captive internal tooth lock washer. Each screw should be torqued to 20 in-lbs. S55 S60 1 2 4 Attach the other end of the ground cable to a suitable ground point. The rack installation ears are not a suitable grounding point. The S60 is shipped with 2 10-32 screws for attaching a ground cable to the chassis. The cable itself is not included. Dell Force10 recommends a 6AWG two-hole lug, #10 hole size, 63" spacing (not included in shipping) to properly ground the chassis. The two-hole lug must be a UL recognized, crimp-type lug. 8 Installing the Hardware

Install the SFP and SFP+ Optics The chassis are shipped as follows: The S55 has 4 SFP optical ports in the PSU side of the chassis in addition to the optional SFP+ optical modules. The S60 has 4 SFP optical ports in the front of the chassis in addition to the optional SFP+ optical modules. CAUTION: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the chassis and its components. WARNING: Follow all warning labels when working with optical fibers. Always wear eye protection when working with optical fibers. Never look directly into the end of a terminated or unterminated fiber or connector as it may cause eye damage. Step Task 1 Position the SFP or SFP+ so it is in the correct position. (The optic has a key that prevents it from being inserted incorrectly.). 2 Insert the optic into the port until it gently snaps into place. NOTE: For details on Dell Force10 supported optics, refer to http://www.force10networks.com/products/specifications.asp Power Up Sequence Supply Power and Power Up the System Dell Force10 recommends re-inspecting your system prior to powering up. Verify that: The equipment is properly secured to the rack and properly grounded. The equipment rack is properly mounted and grounded. The ambient temperature around the unit (which may be higher than the room temperature) is within the limits specified for the unit. There is sufficient airflow around the unit. Installing the Hardware 9

The input circuits are correctly sized for the loads and that sufficient overcurrent protection devices are used. All protective covers are in place. Blank panels are installed if optional modules are not installed. Blank panels are installed if redundant power supplies are not installed on the S55. NOTE: A US AC power cable is included in the shipping container for powering up an AC power supply. All other power cables must be ordered separately. CAUTION: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the system and its components. When the chassis powers up, the fans immediately come on at high speed. The fan speed slows as the system boots up. The PWR LED blinks until the boot-up sequence is complete. When the boot up is complete the PWD LED is steadily lit. The Stack ID LED displays a digit to show the position of the unit in a stacking chain. For a single chassis, a 0 displays. AC Power Connect the plug to each AC receptacle, making sure that the power cord is secure. As soon as the cable is connected between the system and the power source, the chassis is powered-up; there is no on/off switch. DC Power To connect the chassis to the DC power source, follow the steps below: Step Task S55 Task S60 1 Connect the plug to each DC receptacle, making sure that the power cord is secure. Remove the small plastic cover from the DC connectors. 10 Installing the Hardware

Step Task S55 Task S60 2 As soon as the cable is connected between the S55 and the power source, the chassis is powered-up; there is no on/off switch. Power Supplies The S55 and S60 chassis are designed to support two hot-swappable power supplies with integrated fans that provide the cooling for the chassis. There are two types of power supplies (AC or DC) and there are two air-flow directions (Normal and Reversed). Two power supplies are required for full redundancy, but each system will operate with a single power supply. In the S55, a blank panel must be attached as redundant power supplies are not installed. In the S60, one of the power supply bays can be equipped with a fan only module. WARNING: To prevent electrical shock, make sure the system is grounded properly. If you do not ground your equipment correctly, excessive emissions may result. Use a qualified electrician to ensure that the power cables meet your local electrical requirements. Fans The chassis come from the factory with the following: Attach the connectors to the both DC power units at the rear of the S60, making sure that the connection is secure. 3 Replace the plastic cover over the DC connectors. 4 Turn the power switch on. The S55 comes with 1 power supply and 2 fan modules installed in the chassis. The S60 comes with 1 power supply and 1 fan module installed in the chassis. Both the fan modules and the integrated fan-power supply are hot-swappable if a second (redundant) power supply is installed and running. With redundant power supplies, traffic will not be interrupted if a fan module is removed. Installing the Hardware 11

NOTE: Both slots must have operating fan units to run the system. If a module is not installed in each slot (either as part of the PSU or as an independent fan module), the system will shut down in 1 minute. The S55 and the S60 both support two airflow direction options. Only a single direction can be used in a chassis; do not mix fan flow types in a chassis. The system will shutdown in 1 minute, if the airflow directions are mismatched. Normal is airflow from I/O panel to power supply Reversed is airflow from power supply to I/O panel There are environmental factors that could decrease the amount of time required between air filter replacements. Check these environmental factors regularly. Any unusual environmental circumstance at the site that causes an increase in temperature and/or particulate matter in the air might affect performance (for example, new equipment installation). Specifications Chassis Physical Design Parameter S55 Specifications S60 Specifications Height 1.73 inches (4.4 cm) 1.7 inches (4.3 cm) Width 17.32 inches (44.0 cm) 17.32 inches (44.0 cm) Depth 18.74 inches (47.6cm) 16.73 inches (42.5cm) Chassis weight with factory-installed components 14.41 pounds (approx.) (6.54 kg) 14.39 pounds (approx.) (6.54 kg) Rack clearance required Front: 5-inches (12.7 cm) Rear: 5-inches (12.7 cm) Front: 5-inches (12.7 cm) Rear: 5-inches (12.7 cm) Thermal dissipation 461 BTU/hr (135W) 597 BTU/hr Power Consumption 115 Watts (nominal) 135 Watts (maximum) 175 Watts (nominal) 225 Watts (maximum) 12 Installing the Hardware

Environmental Parameters Parameter S55 Specifications S60 Specifications Temperature Maximum altitude 32 to 104 F (0 to 40 C) -40 to 158 F (-40 to 70 C) No performance degradation to 10,000 feet (3,048 meters) 32 to 122 F (0 to 50 C) -40 to 158 F (-40 to 70 C) non-operating No performance degradation to 10,000 feet (3,048 meters) Relative humidity 10 to 85% non-condensing 10 to 85% non-condensing 5 to 95% non-condensing (non-operating) Shock MIL-STD-810 MIL-STD-810 Vibration Bellcore GR-63 AC Power Requirements Parameter S55 Specifications S60 Specifications Nominal Input Voltage 100 to 240 VAC, 47-63 Hz 100 to 240 VAC, 50/60 Hz Maximum AC Power Supply Input Current Maximum System Power Input 5 A 2 A at 100/120 VAC 135 W 225W DC Power Requirements Parameter S55 Specifications S60 Specifications Nominal Input Voltage Maximum Power Supply Input Current Maximum System Power Input -43 to -72 VDC at startup -36 to -72 VDC during normal operation 40 to 60 VDC 10 A 3.6 A at -48 VDC 135 W 225W Power Supplies The S55 and the S60 are designed to support two hot-swappable power supplies with integrated fans that provide the cooling for the chassis. Installing the Hardware 13

WARNING: To prevent electrical shock, make sure the systems are grounded properly. If you do not ground your equipment correctly, excessive emissions may result. Use a qualified electrician to ensure that the power cables meet your local electrical requirements. WARNING: Electrostatic discharge (ESD) damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the systems and their components. CAUTION: Remove the power cable from the modules prior to removing the module itself. Power must not be connected prior to insertion in the chassis. WARNING: Prevent exposure and contact with hazardous voltages. Do not attempt to operate this system with the safety cover removed. CAUTION: The DC power supply comes with a 6-8inch cord with a snap-in plug that attaches to the DC power supply and screw terminals that attach to the main power. Dell Force10 recommends using a longer cable, to ensure sufficient room. CAUTION: The power supply is marked + 48V -. Connect the + (plus sign) to the red cable on the 6-8 inch cord; the - (minus sign) connects to the black cable. BE SURE TO connect the RED to RETURN and connect the BLACK to -48V. NOTE: For a NEBS compliant installation, the AC power connections must use a surge protection device (SPD) to protect the AC power supplies from damage to excessive power line surges. NOTE: To comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC Power Ports, an external surge protection device (SPD) is intended to be used at the AC input of the router. NOTE: The DC power return conductor must be isolated from the chassis or frame when connections to the power supply are made. 14 Installing the Hardware

Install a DC Power Supply The power supply modules should slide into the slots smoothly. Do not force a module into a slot. This may damage the power supply or the chassis. S55 S60 Securing Screw Fans and Filters Fan Module PSU0 PSU1 PSU0 Optional Module Grab Handle DC Power Connector Power Switch Cable Connector PSU1 Grab Handle Step Task 1 Take the power supply unit out of the shipping box. 2 Remove the small plastic cover over the DC connectors. Do not throw the cover away; you will replace it when installation is complete. 3 Using the grab handle, slide the unit in to the power supply bay. 4 Tighten the securing screw at the top of the unit. 5 Attach power cables. 6 Replace the small plastic cover over the DC connectors. 7 Turn on power if installing a DC unit. Installing the Hardware 15

16 Installing the Hardware

2 Installing the Software Navigating CLI Modes The FTOS prompt changes to indicate the CLI mode. You must move linearly through the command modes, with the exception of the end command which takes you directly to EXEC Privilege mode; the exit command moves you up one command mode level. Console Access NOTE: You must have a password configured on a virtual terminal line before you can Telnet into the system. Therefore, you must use a console connection when connecting to the system for the first time. The S55/S60 has 2 management ports available for system access: a serial console port and a USB-B port. The USB-B ports acts exactly as the console port. By default, the S55/S60 sends system messages to the serial console port. However, only one console connection can be active at a time. When both the serial console port and the USB-B port are connected, the system defaults to the USB-B port. The console connection is considered inactive if the USB-B port is also connected. You can switch between console connections by physically connecting or disconnecting the cables. A system message is displayed on the serial console prior to switching to the USB-B console. When the USB-B cable is detached, the system returns to the serial console default. Installing the Software 17

Serial Console The RS-232 console port is labeled on the chassis. It is in the upper right-hand side, as you face the rear of the chassis. S55 RJ-45 Console Port S60 Console Port Step Task 1 Install an RJ-45 copper cable into the console port.use a rollover (crossover) cable to connect the S55 or S60 console port to a terminal server. 2 Connect the other end of the cable to the DTE terminal server. 3 Terminal settings on the console port cannot be changed in the software and are set as follows: 9600 baud rate No parity 8 data bits 1 stop bit No flow control Accessing the RJ-45 console port with a DB-9 adapter You can connect to the console using an RJ-45 to RJ-45 rollover cable and an RJ-45 to DB-9 female DTE adapter to a terminal server (for example, PC). Table 2-1 lists the pin assignments. Table 2-1. Pin Assignments Between the Console and a DTE Terminal Server S55/S60 Console Port RJ-45 to RJ-45 Rollover Cable RJ-45 to DB-9 Adapter Terminal Server Device Signal RJ-45 pinout RJ-45 Pinout DB-9 Pin Signal RTS 1 8 8 CTS 18 Installing the Software

Table 2-1. Pin Assignments Between the Console and a DTE Terminal Server S55/S60 Console Port NC 2 7 6 DSR TxD 3 6 2 RxD GND 4 5 5 GND GND 5 4 5 GND RxD 6 3 3 TxD NC 7 2 4 DTR CTS 8 1 7 RTS USB-B Console RJ-45 to RJ-45 Rollover Cable RJ-45 to DB-9 Adapter Terminal Server Device Signal RJ-45 pinout RJ-45 Pinout DB-9 Pin Signal The USB-B connector port is labeled on the S55/S60 chassis. It is to the left of the management ports, as you face the rear of the chassis. S55 S60 USB-B Port USB-B Port Step Task 1 Power on the PC (XP operating system recommended). 2 Connect the USB-A end of cable (supplied) into an available USB port on the PC. 3 Connect the USB-B end of cable into the USB-B console port on the chassis. 4 Power on the chassis. 5 Install necessary USB device drivers (internet connection required). Contact Dell Force10 TAC for CD, if necessary. Installing the Software 19

Step Task 6 Open your terminal software emulation program to access the chassis. 7 Using the terminal settings shown here, set the terminal connection settings. 9600 baud rate, No parity, 8 data bits, 1 stop bit, No flow control 8 You will see the message below when you are connected to the chassis. Default Configuration A version of the Dell Force10 Operating System (FTOS) is pre-loaded onto the chassis, however the system is not configured when you power up for the first time (except for the default hostname, which is Force10). You must configure the system using the Command Line Interface (CLI). Configure Layer 2 (Data Link) Mode Use the switchport command in INTERFACE mode to enable Layer 2 data transmissions through an individual interface. The user can not configure switching or Layer 2 protocols such as spanning tree protocol on an interface unless the interface has been set to Layer 2 mode. Step Task Command Syntax Command Mode 1 Enable the interface. no shutdown INTERFACE 2 Place the interface in Layer 2 (switching) mode. switchport To view the interfaces in Layer 2 mode, use the show interfaces switchport command in the EXEC mode. Configure a Host Name INTERFACE The host name appears in the prompt. The default host name is Force10. Host names must start with a letter and end with a letter or digit. Characters within the string can be letters, digits, and hyphens. 20 Installing the Software

Task Command Syntax Command Mode Create a new host name. hostname name CONFIGURATION Access the System Remotely You can configure the system to be accessed remotely by Telnet. Both the S55 and the S60 has a dedicated management port and a management routing table that is separate from the IP routing table. Step Task 1 Configure an IP address for the management port. 2 Configure a management route with a default gateway. 3 Configure a username and password. Configure the Management Port IP Address Assign IP addresses to the management ports in order to access the system remotely. NOTE: Assign different IP addresses to each RPM s management port. Step Task Command Syntax Command Mode 1 Enter INTERFACE mode for the Management port. 2 Assign an IP address to the interface. Configure a Management Route interface ManagementEthernet slot/port ip address ip-address/mask CONFIGURATION INTERFACE 3 Enable the interface. no shutdown INTERFACE Define a path from the system to the network from which you are accessing the system remotely. Management routes are separate from IP routes and are only used to manage the system through the management port. Installing the Software 21

Task Command Syntax Command Mode Configure a management route to the network from which you are accessing the system. management route ip-address/mask gateway Configure a Username and Password CONFIGURATION Configure a system username and password to access the system remotely. Task Command Syntax Command Mode Configure a username and password to access the system remotely. username username password [encryption-type] Configure the Enable Password CONFIGURATION The EXEC Privilege mode is unrestricted by default. Configure a password as a basic security measure. There are two types of enable passwords: enable password stores the password in the running/startup configuration using a DES encryption method. enable secret is stored in the running/startup configuration in using a stronger, MD5 encryption method. Dell Force10 recommends using the enable secret password. Task Command Syntax Command Mode Create a password to access EXEC Privilege mode. enable [password secret] [level level] [encryption-type] password CONFIGURATION 22 Installing the Software

Create a Port-based VLAN The Default VLAN as VLAN 1 is part of the system startup configuration and does not require configuration. To configure a port-based VLAN, you must create the VLAN and then add physical interfaces or port channel (LAG) interfaces to the VLAN. Task Command Syntax Command Mode Configure a port-based VLAN (if the vlan-id is different from the Default VLAN ID) and enter INTERFACE VLAN mode. interface vlan vlan-id CONFIGURATION NOTE: After you create a VLAN, you must assign interfaces in Layer 2 mode to the VLAN to activate the VLAN. Use the show vlan command in the EXEC privilege mode to view the configured VLANs. Assign Interfaces to a VLAN To view just the interfaces that are in Layer 2 mode, enter the show interfaces switchport command in the EXEC privilege mode or EXEC mode. To tag frames leaving an interface in Layer 2 mode, you must assign that interface to a port-based VLAN to tag it with that VLAN ID. To tag interfaces, use these commands in the following sequence: Step Task Command Syntax Command Mode 1 Access the INTERFACE VLAN mode of the VLAN to which you want to assign the interface. 2 Enable an interface to include the IEEE 802.1Q tag header. interface vlan vlan-id tagged interface CONFIGURATION INTERFACE Installing the Software 23

Use the untagged command to move untagged interfaces from the Default VLAN to another VLAN: Step Task Command Syntax Command Mode 1 Access the INTERFACE VLAN mode of the VLAN to which you want to assign the interface. 2 Configure an interface as untagged. This command is available only in VLAN interfaces. interface vlan vlan-id untagged interface Assign an IP address to a VLAN CONFIGURATION INTERFACE NOTE: An IP address cannot be assigned to the Default VLAN, which, by default, is VLAN 1. To assign another VLAN ID to the Default VLAN, use the default vlan-id vlan-id command. Task Command Syntax Command Mode Configure an IP address and mask on the interface. ip address ip-address mask [secondary] INTERFACE Connecting the Chassis to the Network Once you have completed the hardware installation and software configuration, you can connect to your company network by following your company s cabling requirements. 24 Installing the Software

Printed in the U.S.A. www.dell.com support.dell.com