Delta V5 operation. Widetron Technologies Corp. Wu, Chung Ying. Progress through Synergy

Similar documents
CHEMISTRY DEPARTMENT Category Work Instruction

NMR INSTRUMENT INSTRUCTIONS: Safety and Sample Preparation

NMR Users Guide Organic Chemistry Laboratory

VNMRJ 4.2 INSTRUCTIONS: QANUC 500 FOR CHEMISTS

MNova Version Installation Instructions.

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 AND VARIAN VNMRS 500

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400

NMR Training VNMRJ 4.2A/VNMRS 400

Routine 1 H and 13 C NMR Data Acquisition Basic Topspin Processing Guide For PSC and NSC Bruker 400 NMR Spectrometer

Bruker Avance 400 MHz Instructions

Vanderbilt Small Molecule NMR Center

NMR Spectroscopy with VnmrJ. University of Toronto, Department of Chemistry

DCIF NMR Training Guide 400 MHz Bruker AVANCE III HD b400 last edit 3/9/2015

c. Saturday and Sunday: 10 minute time blocks and unlimited time.

Varian Solution NMR Procedure

DCIF NMR Training Guide 401 MHz Bruker AVANCE III HD b401 last edit 3/11/2015

Varian Solution NMR Automation Procedure (VNMRS Machines running VNMRJ 4.2 under Red Hat Enterprise 5.1)

PROCESSING 2D SPECTRA USING VNMRJ JB Stothers NMR Facility Materials Science Addition 0216 Department of Chemistry Western University

NMR Spectrometer Crib-Sheet

Bruker NMR Topspin Manual

1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR. Spectrometer without the Sample Changer and IconNMR

67 Series Spectrophotometer PC Software

North Carolina State University Department of Chemistry Varian NMR Training Manual

SAFARI General Instructions

Bruker Topspin NMR Training Manual

JASCO CANVAS PROGRAM OPERATION MANUAL

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

PINMRF. Bruker AV-III / Avance DRX NMR Spectrometers running TopSpin Training Supplement for Advanced 1D NMR Spectroscopy

Introduction to Microsoft Excel

Protein Deconvolution Quick Start Guide

4. The editing tool bar will appear across the top of the map.

Part 2 Add Frame, Arrow, Painted Text.

TopSpin. Multiplet Analysis Tutorial

Galaxie Report Editor

Brief IconNMR and Topspin 3.5 User Guide for Bruker NMR Spectrometers Avance IIIHD 400MHz NMR with Autosampler in Chemistry room 93 DISCLAIMER

Quick Start Guide. Introduction. Importing Raw Data. Method 1: Use Open Data Panel

Diffusion Ordered Spectroscopy (DOSY) Overview BRUKER last edit 5/14/12

Sema Foundation ICT Department. Lesson - 18

Short instructions for the basic operation of the AVANCE II 400 MHz Bruker NMR Using ICON-NMR (PS751)

Quick Guide to Topspin

Galaxie Photodiode Array Software

EQNMR Facility Rules of Use

NMR Assignments using NMRView I: Introduction to NMRView

1. AUTO CORRECT. To auto correct a text in MS Word the text manipulation includes following step.

IMSERC NMR MANUAL 02: Basic Processing of Varian 1D NMR Data

Object Manipulation and Basic Animation

Spectrometer Visible Light Spectrometer V4.4

Agilent MassHunter Qualitative Data Analysis

Bruker AVANCE III HD 400 MHz Spectrometer Operation

Capstone Appendix. A guide to your lab computer software

Bruker OminiFlex MALDI-TOF Mass Spectrometer Operation Quick Start

This presentation takes you through Region of Interest (ROI) Analysis.

DinoCapture Additional Software Instructions for Measurement models

Image Viewing. with WebScope

NMR Assignments using NMRView I: Introduction to NMRView

QUANTAX EDS SYSTEM SOP

Agilent VnmrJ 3.2. Quick Start Guide

Procedures for Group Quantitation

Introduction And Overview ANSYS, Inc. All rights reserved. 1 ANSYS, Inc. Proprietary

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software

Quick Start Guide: COLLECT

To Plot a Graph in Origin. Example: Number of Counts from a Geiger- Müller Tube as a Function of Supply Voltage

Instructions for 1 H-, 13 C-, 19 F-, and 31 P-Spectra on the Varian Mercury-Vx-300

Excel Basics. TJ McKeon

MALDI Software Users Guide (simplified version)

Processing data with Bruker TopSpin

For questions please contact: Lei-Ann Arceneaux, 4/13/2011

0. Procedure for Processing of NMR data

DATA ANALYSIS HIGHLIGHTS TOPICAL DESCRIPTION OF SOFTWARE

PINMRF. Varian 300 MHz NMR Spectrometers Training Guide for Basic 1D NMR Spectroscopy

Central Management Software for NVR-915 / NVR-1615 CV5-M256

Day : Date : Objects : Open MS Excel program. Subject : * Open Excel application. Select : start. Choose: programs. Choose : Microsoft Office

Microsoft Excel Microsoft Excel

DinoCapture Additional Software Instructions

Drawing. Chapter 12. Beam. A. Insert Views. Step 1. Click File Menu > New, click Drawing and OK. Step 2. Click Model View. on the View Layout toolbar.

Using IPACS Webserver:

introduction Manipulate objects and navigate in the 3Dworld Use the electronic catalogue (ecat) Change component parameters Connect components

Fitting NMR peaks for N,N DMA

Opening Screen When you first enter Slick!, a blank opening screen will appear as shown below.

BioIRC solutions. CFDVasc manual

Agenda. Spreadsheet Applications. Spreadsheet Terminology A workbook consists of multiple worksheets. By default, a workbook has 3 worksheets.

Microsoft Excel Basics Ben Johnson

DCIF NMR Training Guide 400 MHz Bruker DRX B401 Bruker DPX B400

Drawing Tools. Drawing a Rectangle

VITALSTIM PLUS Software Tutorial

Opal RAD User Manual

TopSpin QuickStart. Default State TopSpin should be running at all times. If this is not the case, you may need to Log In and Start TopSpin.

How to analyze complex NMR signals through spin simulation/iteration

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

Basic Procedure 1D NMR Data Collection

1 Filter the search by entering search criteria; 2 Enter a range of dates in which to search. 3 You can filter the search by modality type.

ibeam CONSTRUCTION CAMERAS

Fixed Perimeter Rectangles Geometry Creating a Document

Chemical Shift Perturbation Tutorial

Fluorimeter User s Booklet

Using Graphics. Digital Camera. Auto Shapes

Create Geomark in Google Earth Tutorial

FOILCONNECT. Quick Start Guide. Starting out. Create new job. Account

Introduction to the Visual Studio.NET Integrated Development Environment IDE. CSC 211 Intermediate Programming

Contents... 1 Installation... 3

Transcription:

Delta V5 operation Widetron Technologies Corp. Wu, Chung Ying

Connect to spectrometer 1. Start Delta V5 (double click ). 2. Open Spectrometer Control (click ). 3. Select spectrometer on Available Instruments. 4. Click and login with delta account (click ). Name Password remarks delta delta For installation account

Sample preparation 1. Set sample tube on SCM. 2. On Samples tab, you must defined your sample information. 3. On Samples tab, click. You can see new sample definition space on sample list. 4. Input sample name. 5. Select solvent. 6. Click Verified. 7. Click sample number. Clicked sample box becomes green color. 8. Click for sample loading.

Set up experiment (automation) 1. Click on Samples tab or key in the job name which you want to define your job. You can see the next tab (Jobs tab).

Set up experiment (automation) 2. We can choose some experiments which user want to do on Job Parameters box. 3. If user want to do another experiment which is not save in available methods, click for another experiments. Available Methods

Set up experiment (automation) 4. If you want to change the more detail parameters, select experiment name on Open Jobs list. Job Name Method Name Experiment Name

Set up experiment (automation) 5. We can change some experiments parameters on Job Parameters box.

Set up experiment (automation) 6. If you first time do this sample, click Force tune and Auto_gain. 7. If you tick Deliver data automatically, you can see the results on your display. 8. The parameters became red word when changed. Deliver data automatically results Data is saved to You can see results on your display. You can t see results on your display. Data Servers (spectrometer) and your workstation Data Servers (spectrometer) only

Submit experiment (automation) 9. Click. The experiments are started. 10. If you want to stop experiment, Click.

Open data (1) Case A: You have already connected to spectrometer. 1. Click on Delta Console window. 2. Click for downloading from spectrometer. You can select and download data.

1D processor (open data file) 1. When you open 1D NMR data, you can see 1D processor window. Sample FID Processing Pointer Bar

1D processor (Pointer Bar) 1. When you open 1D NMR data, you can see Pointer Bar. : Zoom (Zoom view of data) : Pan View (Pan view of data or slide view) : Amplitude gain (apply amplitude gain) : Select (To select data of geometry) : Phase correct (To adjust the phase of spectra) : Copy position (Copy position to paste buffer) : Peak threshold (Adjust the peak threshold) : Reference (To set a chemical shift reference axis marker) : Peak (Peak picking tool) : Integral (Integral tool) : Measure (To measure distance between peaks) : Cursor (make the horizontal and vertical line) : Annotation (edit annotation in the geometry) : Molecule (To display a structural formula and molecular formula in the geometry ) : PiP (Picture in Picture)

1D processor (open process list) 1. When you open 1D NMR data, you can see 1D processor window. Open processing list Apply process_list 2. If you want to open process_list, click. 3. When you apply process_list, click. * : for 1H process_list, : for 13C process_list

1D processor (edit process list) 1. When you want to edit process, you can edit on Processing tool. 2. If you click, you can see detail parameters for processing command. 3. When you apply process, click. 4. If you click, you can undo your process list.

1D processor (phase correction 1) 1. When you click (auto phase), the phase of spectrum is adjusted. 2. You can see phase correction values on the left upper in spectrum. 3. Those values are inputted in Phasing Tool. 4. If you want to adjust those, you can manipulate with Phasing Tool. 5. When you finish to adjust, click. (If you can t see Phasing Tool, please click on the left. )

1D processor (phase correction 2) 1. Click at Pointer Bar. (Pointer bar is on processor window.) 2. You can see the vertical line on you spectrum. 3. When your mouse cursor moves to that line, mouse cursor is changed to. 4. In that situation, you can change φp with dragging. 5. If you want to adjust φ0 and φ1, you can manipulate with Phasing Tool.

1D processor (Zoom process) 1. Click at Pointer Bar. (Pointer bar is on processor window.) 2. You can see your mouse cursor became magnifer. 3. When you drag any region or the border, the process window zoom will be changed.

1D processor (Peak threshold) 1. Click at Pointer Bar. (Pointer bar is on processor window.) 2. You can see your mouse cursor became peak threshold. 3. You could drag the green line or red line, this process influence peak picking and integral.

1D processor (Peak picking 1) 1. When user decide their peak threshold, click for auto peak picking

1D processor (Peak picking 2) 1. Click at Pointer Bar. (Pointer bar is on processor window.) 2. You can see your mouse cursor became peak picking. 3. Which peak you want to pick, move the mouse cursor to peak and click left mouse button.

1D processor (Peak integral 1) 1. When user decide their peak threshold, click for auto peak integral.

1D processor (Peak integral 2) 1. Click at Pointer Bar. (Pointer bar is on processor window.) 2. You can see your mouse cursor became peak picking. 3. Which peak you want to integral, move the mouse cursor to peak and drag the region by left mouse button.

1D processor (options) If you can t see Options panel, please click on the left. Peak Sep. : The minimum value between peak and peak for peak picking. Int Width : The range of integral. Nomal : Normalize value for integral. X Ref : the value for calibrating chemical shift. X start : the right edge of the spectrum. X Stop : the left edge of the spectrum.

1D processor (Peak reference) 1. Click at Pointer Bar. (Pointer bar is on processor window.) 2. You can see your mouse cursor became reference. 3. Which peak you want to decide reference peak, set the value in Xref on option bar and move the mouse cursor to peak and click by left mouse button.

1D processor (Peak integral normalized) 1. After auto integral, user could see the result about integral. 2. Click at Pointer Bar. (Pointer bar is on processor window.), select the integral and key in the value which user want to normalized on option bar

1D processor (prepare print) 1. After data process, click alt+f for data file name and alt+shift+c for method.

1D processor (prepare print) 1. Click. For pint data file. 2. If user want to print shim parameters, click delta and tick the print parameters and choose the location

Set up experiment ( 13 C automation) 1. We can click the carbon experiment icon on Job tab.

Set up experiment ( 13 C automation) 1. If you first time do this sample, click Force tune and Auto_gain. 2. If you tick Deliver data automatically, you can see the results on your display. 3. The parameters became red word when changed. Deliver data automatically results Data is saved to You can see results on your display. You can t see results on your display. Data Servers (spectrometer) and your workstation Data Servers (spectrometer) only

Set up experiment ( 13 C automation) 1. Click. The experiments are started. 2. Wait to collect data.

Set up experiment ( 13 C automation) 1. Click, and observed the real time spectrometer.

Set up experiment ( 13 C automation) 1. If you want to stop experiment, Click. 2. If tick save_aborted (default parameters), stop experiment, the data file will be saved in console

Finish experiment 1. When finish your experiment, click and check the Quene tab which is empty.

Finish experiment 1. Click and check the Job tab which is empty. 2. If not empty, click the Job and click to delete Job.

Finish experiment 1. Click and click verified. 2. Sample will eject 3. Click to delete sample for next user to use software.

Finish experiment 1. Check all your file will be save and click to close delta software.