Platinum RTD Thermometer MODEL NO

Similar documents
Platinum RTD Thermometer MODEL NO

Instruction Manual. Single-Input RTD Thermometer (Model )

Barnant Company. Humidity Data Logger MODEL NO YR MIN HOLD MO MAX DAY STORE LOG RECALL PRINT C/ F PRINT SETUP.

Temp-360 RTD Data logging Thermometer

OPERATING MANUAL COMPACT PUMP DRIVES MODEL NOS.

HI HI N HI HI

PUMP DRIVE OPERA TING MANUAL: A Edition 01

HI HI N HI HI

Cole-Parmer Instrument Company

Instruction Manual Temp JKT Temperature Meter Series

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Mini Digital Multimeter

User Guide. Moisture Meter. Model MO250

User's Guide. Extech AM A AC Analog Clamp Meter

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

HI HI HI HI Portable Microprocessor Thermistor Thermometers

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Cole-Parmer Instrument Company

Model ST-610B. Instruction Manual. Digital Thermocouple Thermometer. reedinstruments. www. com

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

TC2100 HOLD MAX AVG MIN SETUP THERMOMETER. K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN. K INTERVAL hour:min POWER T1 T2.

RS Stock No Instruction Manual RS Input Data Logging Thermometer

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual.

WalkLAB ph mv/orptemperature

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

User Guide True RMS Multimeter Extech EX205T

True RMS Multimeter with IR Thermometer

WEB SITE:

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

-auto Power Off- T1/T2/T1-T2

HI ma Simulator

Pro II. Sound Level Meter V-9992

Model R2400. Instruction Manual. Digital Thermocouple Thermometer. reedinstruments

HI ma Simulator

DEVAR Inc. Model d-rtti User Manual

Sound Level Pen Instruction Manual

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

BetaProbe TI/TI+ High Accuracy Digital Thermometer. User Reference Manual

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

Mini Digital Multimeter

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

HI 8751 HI 8752 HI 8753 Portable Thermistor Thermometers

Mini Digital Multimeter

50 Amp AC/DC Current Probe PA-655 INSTRUCTION MANUAL 安培交流 / 直流電流探測鉗. DC 500KHz. 5mA 50A.

Instruction Manual Extreme Temperature (XT) Data Logger

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Mini Digital Multimeter Model MN15. User's Guide

Type K/J Thermometers

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

GE Infrastructure Sensing. Druck DPI 832. Electrical loop calibrator User manual - K393

Variable-Speed Vortex Mixer

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

MODEL PS-11 DIGITAL PORTION SCALE

TC100 Precision Thermocouple Calibrator

User s Guide. 600A AC Clamp Meter. Model 38387

Model 6815 HYGRO-THERMOMETER ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

OPERATING MANUAL. EchoThermJ PROGRAMMABLE, DIGITAL, ELECTRONIC CHILLING/HEATING PLATE MODEL IC25, IC25XR, IC25XT, IC35 and IC35XT

Dual Moisture Meter Pin / Pinless Moisture Meter

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

Digital Thermometer MEM. PC-Link READ

Video Borescope Inspection Camera

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

HAND-HELD THERMOCOUPLE THERMOMETER SERVICE MANUAL. CATALOG NUMBERS , and , and PROPRIETARY

Druck DPI 620 advanced modular calibrator

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Instruction Manual Standard Multi-Position Stirrers Advanced Multi-Position Stirrers

OPERATION MANUAL MODEL TT-LP

Instruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications.

VELOCICALC Air Velocity Meter

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

Operations Manual EcoSense ph100

Sonic Ruptor 400. User Manual

4-Channel Thermometer

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

DC 100 A Current Probe

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Operation Manual. MODEL ph/ec80. Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter. ph/ec80

User's Guide. MiniTec TM Series Model MN25 MultiMeter

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

Nuclear Associates

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

Series RMT Hot Runner Controller Setup and Operation Manual

DC 100 A Current Probe

Vibration Meter Instruction Manual

CM-140. Instruction Manual SOUND LEVEL METER G A L A X Y A U D I O

PV Remote Unit A 1378 Instruction manual Version 2.1, Code no

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

DICKSON TC200/TH300 DICKSON. Handheld Temperature and Temperature / RH Indicators. Useful Features. Applications & Product. Specifications.

Transcription:

Platinum RTD Thermometer MODEL NO. 93410-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com e-mail: techinfo@coleparmer.com A-1299-0864 Edition 01 68X309904 Rev 1 04/04

INTRODUCTION This versatile hand-held instrument provides highly accurate temperature measurements. The instrument is designed for easy operation and includes the following features: Operator selection of Celsius or Fahrenheit scale Resolution of 0.1 (auto ranging) Four-digit LCD Hold feature for temporarily retaining a reading Field calibration capability Low battery warning Built-in tilt stand for easy hands-free operation 3-pin circular connector input Operates with a wide selection of probes 1

SAFETY PRECAUTIONS DANGER VOLTAGES PRESENT AT THE RTD MAY ALSO BE PRESENT AT THE BATTERY TERMINALS. AL- WAYS DISCONNECT THE RTD WHEN CHANG- ING BATTERIES. THIS INSTRUMENT IS WARNING DESIGNED TO ACCEPT LOW LEVEL SIGNALS SUPPLIED BY STAN- DARD 100 OHM PLATINUM RTDS. UNDER NO CIRCUMSTANCES SHOULD THE INPUT VOLT- AGE EXCEED THE SPECIFIED 10 V RMS. DO NOT USE OR STORE CAUTION THIS INSTRUMENT IN MICROWAVE OVENS OR ANY ABNORMALLY HOT OR COLD AREAS. WEAK BATTERIES SHOULD CAUTION NOT BE LEFT IN THE IN- STRUMENT. DEAD BATTERIES CAN LEAK AND CAUSE DAMAGE TO UNIT. 2

SPECIFICATIONS PLATINUM RTD PROBES 100 ohm platinum: alpha = 0.003850 200 C to 850 C ( 392 F to 1562 F) Out of range display: Ur, Or, open Accuracy and Resolution: Range Accuracy Resolution 200 to 100 C ( 392 to 148 F) ±2 C (±4 F) 1 100 to 200 C ( 148 to 392 F) ±0.2 C (±0.4 F) 0.1 200 to 850 C (392 to 1562 F) ±2 C (±4 F) 1 Display: 4-digit LCD with 0.4 inch (10 mm) high numerals. Display update rate: 0.5 sec per update. Input: One probe with 3-pin circular connector (Switchcraft TA3F). Input Protection: 10V rms Battery: Two AA, 1.5V alkaline ANSI-L40, IEC- LR6. Battery Life: 200 hours continuous, typical. Low battery indication: Battery symbol on when 8 to 10 hours of battery life remains. Auto Shutoff: 17 minutes after last key press. 3

Operating: Stated accuracy: 18 C to 28 C (64 F to 82 F) Useful range: 0 C to 40 C (32 F to 104 F) Storage: 40 C to 65 C ( 40 F to 149 F) Humidity: 10% to 90% (non-condensing) Dimensions 3 cm D x 8.4 cm W x 15.8 cm H (1.2 in x 3.3 in x 6.2 in) Weight with batteries: 227 grams (8 ounces) Ingress protection: Meets IEC-529 IP-54 for dustand water-resistant enclosures. Compliance (For CE Mark): EN61326-1/A1: 1998 (EU EMC Directive) 4

BATTERY INSTALLATION AND REPLACEMENT VOLTAGES PRESENT AT DANGER THE RTD MAY ALSO BE PRESENT AT THE BATTERY TERMINALS. AL- WAYS DISCONNECT THE RTD WHEN CHANG- ING BATTERIES. WEAK BATTERIES SHOULD CAUTION NOT BE LEFT IN THE INSTRUMENT. DEAD BATTERIES CAN LEAK AND CAUSE DAMAGE TO UNIT. 5

If battery indicator turns on, battery life is approximately 8 to 10 hours. See SPECIFICATIONS for battery type. 1. Before changing battery, turn instrument off and disconnect probe. 2. Loosen screw and lift battery cover off back of case. 3. Remove the two AA batteries. 4. Insert two new batteries, observing polarity. 5. Install cover and tighten screw. 6

CONNECTING AN RTD Use the correct 100 ohm RTD (alpha = 0.003850) for your instrument. Using an incorrect probe type will result in erroneous readings. Insert the 3-pin plug into the mating connector on the top of the instrument. 7

8

9

OPERATION 1. Press the ON/OFF key. The thermometer performs a self-test and all display digits and indicators, as shown below, should remain on for approximately two seconds. 2. If a probe is not connected or if the probe is defective, the display will indicate open. 3. Select C or F by pressing the C/ F key. Temperature scale can be switched at any time. The thermometer retains the last selected scale the next time you turn the power on. 4. For optimum instrument accuracy, allow one minute for ambient temperature stabilization. If the unit has been stored at an extreme ambient condition, more time will be needed. When taking temperature measurements, allow time for the reading to stabilize. Multiplying the time constant of the probe by 5 will give you the approximate time required. If desired, press the HOLD key to retain the reading on the display. Press HOLD key again for normal operation. The display will show Ur (under range) or Or (over range) if the temperature reading is out of range of the instrument. 10

FIELD CALIBRATION The thermometer is factory calibrated and does not require calibration before use. The CAL function allows single point calibration of the thermometer at 0 C (32 F) to compensate for probe offset error. It is not necessary to perform a field calibration to obtain specified meter accuracy. Use the field calibration feature to improve thermometer/probe accuracy. 1. Follow steps 1 through 4 in FIELD CALIBRA- TION CLEAR/UNLOCK section. 2. Pack sensing end of probe in a container tightly packed with crushed ice and filled with distilled water. Allow temperature to stabilize. 3. Press and release the CAL key to enter the calibration mode. 4. The display will momentarily show CA and then the temperature reading starts blinking. 5. If the measured temperature is from 5 C to 5 C (23 to 41 F) when the temperature reading is stable, press the HOLD key to confirm calibration. The display will momentarily show CO and the reading will be set to 0 C (32 F). The CAL indicator will turn on, indicating a field calibration is active. The field calibration is automatically locked as well. If Err is displayed, either the displayed reading is outside the above limits or the batteries are weak. 11

FIELD CALIBRATION CLEAR/UNLOCK The calibration clear/unlock feature will cancel any previous field calibration (the thermometer reverts to the default factory calibration) and also enables the field calibration operation. 1. Turn the thermometer off. 2. Hold the CAL key down while pressing the ON/ OFF key. 3. Unit will first display 8888 then the firmware version number. 4. When the CAL key is released, the unit will return to measurement mode. FIELD CALIBRATION LOCKOUT The calibration lockout feature prevents any field calibration changes. The lockout remains in effect until a clear/enable has been performed. Use the following procedures to lockout the field calibration operation. Lockout Procedure 1. Turn the thermometer off. 2. Hold the HOLD key down while pressing the ON/ OFF key. 3. Unit will first display 8888 then the firmware version number. 4. When the HOLD key is released, the unit will display 8888 and then turn off. (If field calibration is already locked, the unit will return to measurement mode.) 12

MAINTENANCE Properly used, the thermometer should maintain calibration indefinitely and not require service other than occasional cleaning of the housing and changing of the batteries. Do not clean with abrasives or solvents. Use mild detergents; never immerse nor use excessive fluid. BATTERIES If there is no display when the thermometer is turned on, check condition of the two AA batteries. Also check that the battery terminals are clean and batteries are properly installed. If replacement is necessary, refer to the BATTERY INSTALLATION AND REPLACEMENT section for replacement procedure. SERVICE There are no internal adjustments or userreplaceable parts. Note: Serial number label is located inside battery compartment. 13

ACCESSORY RTD PROBES Cole-Parmer offers a wide variety of RTD probes, connectors, extension cables, accessories and calibration services. The popular probes listed below have a nylon handle, a 5-ft coiled cord and a 316 SS sheath. General-purpose probe, 10 in long x 0.188 in dia. 10 second time constant. 08117-70 PTFE-coated general-purpose probe, 10 in long x 0.145 in dia. 15 second time constant. 08117-87 Penetration probe, 4 in long x 0.188 in dia sharp tip. 10 second time constant. 08117-85 Surface probe, 8 in long with 0.25 in dia aluminum and ceramic tip. 24 second time constant. 08117-75 Air/gas probe, 10 in long sheath with 0.25 in dia radiant heat shield. 4 second time constant. 08117-90 37000-98 Carrying case. Hard plastic case with foam insert holds one meter and up to five probes. Measures 21 in W x 12 in H x 3 in D. 91100-90 Soft carrying case.

WARRANTY The Manufacturer warrants this product to be free from significant deviations from published specifications. If repair or adjustment is necessary within the warranty period, the problem will be corrected at no charge if it is not due to misuse or abuse on your part as determined by the Manufacturer. Repair costs outside the warranty period, or those resulting from product misuse or abuse, may be invoiced to you. This product comes with a 3 year warranty. PRODUCT RETURN To limit charges and delays, contact the seller or Manufacturer for authorization and shipping instructions before returning the product, either within or outside of the warranty period. When returning the product, please state the reason for the return. For your protection, pack the product carefully and insure it against possible damage or loss. Any damages resulting from improper packaging are your responsibility. TECHNICAL ASSISTANCE If you have any questions about the use of this product, contact the Manufacturer or authorized seller. Trademarks bearing the symbol in this publication are registered in the U.S. and in other countries. A-3477-69 Printed in Singapore 68X309904 Rev 1 04/04