Sample. Pearson BTEC Levels 4 Higher Nationals in Engineering (RQF) Unit 15: Automation, Robotics and Programmable Logic Controllers (PLCs)

Similar documents
output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

Applications of Programmable Logic Controllers DG31 34

-----other notes This picture was taken from here:

Programmable Logic Controller

EEET 2204 Industrial Automation

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

ELECTRONIC SYSTEMS. Politecnico di Torino - ICT school. Goup B - goals. System block diagram Sensors and actuators Analog and digital signals


Question & its answer Remark Total marks 01 Attempt any THREE 12. a) State any three different tools used for Automation. 04 Ans.

Home Security System with Remote Home Automation Control

FMS-200 Flexible integrated assembly systems

Branch PLC. Velocio s Branch PLC

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

Electropneumatics Basic Level Textbook TP 201

PROGRAMMABLE LOGIC CONTROLLERS. Wiley USING CODESYS A PRACTICAL APPROACH TO IEC. Dag H. Hanssen Institute of Engineering and Safety,

Accessories. Embedded Control. Order number: Flash-RAM memory module, 128 K x 16 (for 680I) Accessories

Combinational and sequential systems. Prof. Cesar de Prada Dpt. of Systems Engineering and Automatic Control UVA

The use of automatic equipment instead of manual labor. Any plant or machine operating by it self without human

Programmable Logic Controllers

Introduction. Upon completion of Basics of PLCs you should be able to: Identify the major components of a PLC and describe their functions

ISSN Vol.03,Issue.06, May-2014, Pages:

1. PLC - Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

Programmable Logic Controller

AU-E - Practical Programmable Logic Controllers (PLCs) for Automation and Process Control

Product type designation. General information. Supply voltage. Input current

Proposal for SAS 2.x Specification to Enable Support for Active Cables

MT2 Introduction Embedded Systems. MT2.1 Mechatronic systems

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Figures 2 and 3 illustrate respectively a photograph and a labelled diagram of the PLC that will be discussed in this class.

NTX Series Product Comparison

Quick Start Installation Guide

HARDWARE OF SUPERVISORY CONTROL & DATA ACQUISITION SYSTEM

Building the Communication Cable

General information. Supply voltage

with its cables, connectors, Switches, Hubs and topologies

DC - Devices and Controller

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

Microprocessors/Microcontrollers

Summer 2003 Lecture 18 07/09/03

WIRELESS SERIES Single or Dual Axis MEMS Inclinometer

Controlesta RCO-Compact

CQM1 THE FLEXIBLE, HIGH SPEED CONTROL SOLUTION

Model User Manual Revision E 04/29/99. OEM Gaging System. Part Number R01

SMART E-BILL GENERATION USING PLC

Controllers. Presentation. Modicon M258 logic controller. Performance. Development and technology. Software configuration

AC : INFRARED COMMUNICATIONS FOR CONTROLLING A ROBOT

ICCS Controllers Intelligent Control and Command Systems

Electrical Motor Controls. Chapter 11 (4 th Edition) Chapter 6 (5 th Edition)

THE MICROCOMPUTER SYSTEM CHAPTER - 2

Limit switches for Dial Thermometers and Pressure gauges

48-Bit Isolated Digital I/O

Keywords: PLC, Three-Phase Induction Motor, AC Current Sensor, Proximity Sensor, AC Voltage Sensor.

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

Product Family: Electro Mechanical Relays Number: AN-LC-008

Product type designation. General information. Supply voltage

With a digital input we can read two states, a high or low. A switch can be open or closed.

Scientech Universal PLC Platform. Features. New

MECHATRONICS CATALOGUE

Q1. Describe C.P.U and its subunits with the help of diagram?

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

PLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

CREATED BY M BILAL & Arslan Ahmad Shaad Visit:

Programmable Logic Controllers

DIGITAL COMPASS SOLUTION

Module 1. Introduction. Version 2 EE IIT, Kharagpur 1

Introduction To Computer Hardware

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Advanced NI-DAQmx Programming Techniques with LabVIEW

Thermocouple Input Module Product Specifications and Installation Data

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

T100MD PLC Installation Guide

Supply voltage. Input current. Encoder supply. Memory

Project Planning. Module 4: Practice Exercises. Academic Services Unit PREPARED BY. August 2012

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

SYSMAC Remote Transistor Module

Installation and Setup

Central Processing Unit - CPU

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

270 MHz Control Modules

Standard Instructions Special Instructions High-Speed Instructions SIMATIC S7-200 Programmable Controller System Manual

- Electronic Limit Switches - Very Accurate - Easy to use - Robust - Dependable - High Resolution - Non Contact Measurement - Wide Temp.

Measurement Systems Datascan Installation and User Guide

Absolute Encoders Multiturn

An OR Operation. Or (O) Function I0.4 Q0.1 I0.5 I0.5 I0.4 Q0.1. Input 3. Input 4. Output 2

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

PROGRAMMABLE LOGIC CONTROLLER

Drive and Control Systems: Technical Update. John A. Looser Faustel, Incorporated

Proposal for SAS 2.x Specification to Enable Support for Active Cables

Modular controllers CECX

Rover 5. Explorer kit

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

solutions for teaching and learning

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

Transcription:

Pearson BTEC Levels 4 Higher Nationals in Engineering (RQF) Unit 15: Automation, Robotics and Programmable Logic Controllers (PLCs) Unit Workbook 1 in a series of 4 for this unit Learning Outcome 1 Design and Operational Characteristics of a PLC System Page 1 of 25

1.1 System Operational Characteristics Unitary PLCs This type of PLC exhibits all the features of a basic system within one compact unit. These may include Power supply CPU (central processing unit) Outputs Inputs Such compact unitary PLCs are commonly attached to the machine which they are intended to control. ADVANTAGES Compactness A complete basic system Portability Cost effectiveness DISADVANTAGES No scope for system expansion Failure often requires total replacement of the PLC Only basic functionality is available Unitary PLCs are often used in applications such as; A small machine Overhead door control Car park access system Parts inspection system Figure 1: The unitary Micro820 PLC from Allen-Bradley Page 5 of 25

Modular PLCs This type of PLC exhibits more features than a basic system because modules may be slotted together. These modules may include Power supply CPU (central processing unit) Outputs Inputs Such modular PLCs are commonly expanded with modules to increase the number of inputs and/or outputs available. ADVANTAGES Expansion Cost effective replacement of faulty modules DISADVANTAGES More expensive than a typical unitary PLC Modular PLCs are often used in applications where many inputs and outputs are required, such as process control in the manufacturing sector. Figure 2: Modular PLC units available from Siemens Page 6 of 25

Rack-mounted PLCs This type of PLC exhibits more features than both the unitary and modular types. They tend to be of a modular design, but these modules are usually supplied on cards which plug into slots on a rack, housed in a cabinet ADVANTAGES Easy expansion Plentiful inputs and outputs Communication with other systems Direct replacement of faulty cards DISADVANTAGES More expensive than a typical unitary or modular PLC Largest power consumption of the three types of PLC Rack-mounted PLCs are often used in complex applications where many inputs and outputs are required, such as large process control systems in the manufacturing sector. Figure 3: Rack-mounted PLC system available from Unico Page 7 of 25

Speed The speed of a PLC is mainly governed by the clock supplied to the CPU (processor). Typical clock speeds can range from 1 MHz up to 1 GHz, and beyond, depending on the sophistication of the system. Memory The working program which controls the operation of a PLC is stored in RAM (random access memory). The RAM in a PLC can range anywhere from a few hundred kb up to hundreds of MB, again, depending on the sophistication of the system. Scan Time The Scan Time of a PLC is the time taken for it to review and store the data files which contain the statuses of all the inputs and outputs. Again, depending on the sophistication of the system, the scan time can be as long as several hundred milliseconds, or as short as several microseconds (or even less). Voltage and Current Limits PLCs can interface with analogue input and output devices. Analogue signals are continuously variable but the range of these signals must be limited to suitable working voltage and current ranges. These will depend upon the PLC you are working with, but a typical voltage range might be 0 to 10 V DC, and a typical current range 4 ma to 20 ma. Input Devices There are very many input devices which can be employed with a PLC. Here is a list mechanical switche for position detection proximity switch photoelectric switch encoder temperature sensor pressure sensor potentiometer strain gauge thermistor thermotransistor Let s have a look at some of the ones highlighted in Bold type; Page 8 of 25

Mechanical Switch for Position Detection Figure 4: Switching arrangements for position detection A mechanical switch may be closed when the presence of a specimen is detected. Configuration (a) causes a DC voltage to be applied to the PLC input when the specimen is present. Arrangement (b) causes 0V DC (ground) to be applied to the PLC input when the specimen is detected. Proximity Switch There are three main types of proximity switch; EDDY CURRENT TYPE Figure 5: Proximity switch using eddy currents The ac current through the coil produces a constant alternating magnetic field. Eddy currents are induced into any close-by metallic object, causing a back e.m.f. (reverse voltage spike) which influences the ac supply current. An integral transistor circuit can be used to assign logic low or logic high when this occurs. Page 9 of 25

REED SWITCH TYPE Figure 6: Proximity switch using Reed contacts Reed contacts are normally close, but not touching. The presence of the magnetic field produced by the magnet causes the contacts to touch, completing a circuit. The removal of the magnet causes the contacts to spring back open. CAPACITIVE TYPE Figure 7: Proximity switch using capacitor dielectric properties An object moving between the plates of a capacitor will change the dielectric s permittivity, and hence the capacitance a change which can be processed as high or low. Page 10 of 25

Photoelectric Switch Figure 8: Object detection using light sources and detectors Transmissive type: detected object breaks a beam of light (a) Reflective type: object reflects a beam of light onto a detector (b) In both types the light is emitted by an LED (infrared). The detector could be a photodiode, phototransistor or photo-conductive cell. Encoder Figure 9: Angle detection using an encoder Page 11 of 25

LED light passes through slots in a disc, and is detected. When the disc is rotated the detected beam is goes and off. Therefore, a pulse is detected for each slot which passes by. The number of pulses is proportional to the angle through which the disc has rotated. With 60 slots then 6 degrees corresponds to moving from one slot to the next (total of 360 degrees, of course). Offset slots can produce much higher resolutions. Temperature Sensor Figure 10: Temperature detection using bi-metallic strips Two metal strips (commonly brass and iron) are bonded together. Each metal expands at different rates when the temperature varies. When the temperature increases the strip curves, causing the contacts to touch. For this to happen we need the metal with the highest expansion (brass) on the outside. Pressure Sensor Figure 11: Pressure detection using a piezoelectric crystal Page 12 of 25

Squeezing a piezoelectric crystal displaces charge on it a voltage appears across it (a). The Motorola MPX100AP (b) has a vacuum on one side of the diaphragm it measures absolute pressure. Many analogue input devices can have their signals digitised using an Analogue-to-Digital Converter (ADC), as in Figure 12; Figure 12: Digitising an analogue input signal The signal from the analogue sensor is presented to the analogue input of the ADC. The ADC then converts the analogue signal into a number of binary digits (8, as shown, or more). This digital representation of the signal is known as a word. With an 8-bit word there are 2 8 = 256 possible digital values. For example, 00000000 is zero, 00000011 is three, 11111111 is 256. We therefore have what we call 256 quantisation levels. Output Devices There are many output devices which can be employed with a PLC. Here is a short list relay contactor solenoid valve motor Let s have a look at a couple of these, highlighted in Bold type; Page 13 of 25

Communication Standards data Figure 15: PLC serial or parallel data RS-232 Serial communication one bit transmitted at a time over a single cable. Serial communication is used for transmitting data over long distances (cheaper). An example serial communications link is between a PLC and a PC, used as a programmer. The most common serial interface is RS-232. The prefix RS stands for Recommended Standard. A UART (universal asynchronous receiver transmitter) is used to convert serial data to parallel data (which the PLC uses internally). Figure 16: RS-232 male connector Although there are 25 pins in the RS-232 connector, only eight of these are commonly used. The pin assignments and descriptions for these are; Pin1: Ground (commonly connected to chassis) Pin 2: Transmitted Page 15 of 25

newer standards, it is possible to send data beyond 3000 feet, but with increasingly impaired data rate, and quality, with distance. In a PLC system, it is common for the RS-422 cable to use a 20 ma current loop for signalling, rather than voltage levels. This will improve immunity to electrical noise and increase the potential usable length of the cable. RS-485 The RS-485 standard is based upon the RS-422 standard. The improvement is that the RS-485 standard allows an output to drive up to 32 receivers. Data rates of 10 Mb/sec are viable, and cable runs of 4000 feet are possible. RS-485 uses three-state logic, meaning that individual transmitters can be turned off. This enables the system to act as a linear bus (i.e. a line) whereby individual devices may be connected along its length. A 120 Ω resistor is recommended to terminate each twisted pair at each end, to minimise noise fast rising signals will cause less corruption when faced with such a lower impedance. Star or Ring connections are not usually recommended, since signal reflections might cause problems. Figure 18: RS-422/485 pinouts Ethernet Basic Ethernet systems rely on a twisted pair of wires, and are therefore serial systems. However, more modern Ethernet systems use more than one twisted pairs, and are therefore considered to be parallel systems. The original Ethernet standard allowed for a transfer rate of up to 2.94 Mb/sec. More modern Ethernet systems can transfer data beyond 400 Gb/sec. Page 17 of 25

Internal Architecture Figure 20: Typical internal architecture of a PLC Figure 20 shows the core internal architecture of a PLC. The CPU (central processing unit) is at the heart of things, of course, and controls all the processes and operations need to maintain functionality. The CPU is time-regulated by a digital clock, which governs the speed at which it executes instructions, and how it synchronises with all other parts of the PLC system. Signals are carried around the various sub-systems by buses (a group of copper tracks on a pcb, or ribbon cable), which serve to convey parallel information in terms of memory addresses, data to be read or written, control signals, and input/output data. The CPU contains an ALU (Arithmetic and Logic Unit) which manipulates data, and carries out operations like addition, subtraction, multiplication and division. The ALU will also perform logical operations, as its name suggests, such as; AND, OR, NOT and exlusive-or. The CPU also contains registers (fast memory) used to hold data when programs execute. Information is conveyed on the buses in binary form (1 s and 0 s). Information may be grouped in words a word could consist of 8 bits (a byte). Each bit of a byte will be carried on its own copper track within the bus. Page 19 of 25

PLC Programming Languages The international standard for PLC programming languages (IEC 61131-3) describes a list of languages to be used with a PLC; Ladder diagram (LD) Sequential Function Charts (SFC) Function Block Diagram (FBD) Structured Text (ST) Mnemonic Instruction List (IL) A major benefit of this standard is that the program developer can choose which of the languages best fits the particular task. Ladder Logic This is by far the main and most common form of programming a PLC. It greatly reduces the amount of training needed by engineers and technicians before they can effectively program a PLC. Figure 22: A basic ladder logic program Don t worry at this stage what all the symbols mean in Figure 22. They will all be explained fully in the next workbook. For now, all you need to know is that the two long parallel vertical lines are the rungs of the ladder, the symbols marked X400/X401/Y430 are normally open contacts, the symbol marked Y430 with a Page 21 of 25

diagonal line is a normally closed contact, and the symbols with the curvy lines are a motor/lamp, as indicated. We read the program at the left of the top rung and move right. Once we have reached the far right hand side we move to the left of the second highest rung and move right again etc. Once we have read all rungs we move back to the start (top) and cycle through the instructions in a loop. Sequential Function Chart These are used to program more advanced PLCs. They are similar to flowcharts but much more powerful, since one does not need to follow a single path, as in a flowchart. Figure 23: A sequential function chart (left) with equivalent ladder logic (centre) Page 22 of 25