Digital Multimeter User's Manual

Similar documents
Model INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

ETHOS Auto Ranging Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Autoranging True RMS Multimeter User Manual

Mini Digital Multimeter

Mini Digital Multimeter

POCKET MULTIMETER Model No: MM18

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

OPERATING INSTRUCTION

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

User Guide True RMS Multimeter Extech EX205T

Mini Digital Multimeter Model MN15. User's Guide

Mini Digital Multimeter

Autoranging Mini Multimeter

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Model R5010. TRMS Digital Multimeter. Instruction Manual

AutoRanging Digital MultiMeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

User's Guide. Digital Multimeter. Model MN42

2 in 1 LAN Tester and Multimeter Model:

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

USER MANUAL. True RMS Multimeter. Extech EX430A

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

USER'S MANUAL DCL-650

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER MAS830 MAS830L

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Model A Mini AC/DC Clamp Meter. User's Guide

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

True RMS Multimeter with IR Thermometer

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patented

Bench Multimeter. Users Manual

MTP INSTRUCTION MANUAL

WARNING CAUTION 1. SAFETY

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented

True RMS Industrial Multimeter Extech EX520

Industrial Multimeter Extech EX510

700 Series 200 Amp Clamp Meters

Autoranging Multimeter Extech EX503

True RMS Digital Bench Multimeter Model:

Digital Clamp Meter User Manual

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A

True RMS Multimeter with IR Thermometer

7032 Digital-Analog Multimeter

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Autoranging Mini Multimeter Model MN16A

Mini Multimeter with Non-Contact Voltage Detector (NCV)

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

Digital Clamp-on Meter Instruction Manual

True RMS Industrial Multimeter Extech EX530

Wireless TRMS Multimeter and Insulation Tester

RS Stock No Instruction Manual RS Input Data Logging Thermometer

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Digital Multimeter Instruction Manual

TENMA INSTRUCTION MANUAL MULTI-TESTER

9040/9040UK. Users Manual. Phase Rotation Indicator

User s Guide. 600A AC Clamp Meter. Model 38387

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

Variable Temperature Digital Solder and Testing Station

Model 3526-B Digi-Probe Multimeter

General Warranty. For more details, please refer to the user manual, it can be downloaded at

User's Guide. Extech AM A AC Analog Clamp Meter

Model. True RMSmA Clamp Meter. Instruction Manual

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

General Warranty. For more details, please refer to the user manual, it can be downloaded at

Digital Clamp-on Meter Instruction Manual

Wireless TRMS Multimeter and Insulation Tester

POCKET MULTIMETER 5115 ENGLISH User Manual

Monarch Instrument 2002 all rights reserved MONARCH INSTRUMENT. True RMS Multimeter. Instruction Manual. Monarch 120

True RMS Multimeter with IR Thermometer

Insulation Resistance Multimeter CAT III

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

OPERATING INSTRUCTIONS

Wireless TRMS Multimeter

OPERATING MANUAL INDUSTRIAL MULTIMETER CMM-40

Digital Clamp-on Meter Instruction Manual

Digital Clamp-on Meter Instruction Manual

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

Wireless TRMS Multimeter

Digital Clamp-on Meter Amp Plus. Instruction Manual

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

Model OPERATING MANUAL

General Warranty. For more details, please refer to the user manual, it can be downloaded at

Digital Clamp-on Meter Amp Plus. Instruction Manual

EARTH RESISTANCE & RESISTIVITY TESTER

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Transcription:

Digital Multimeter User's Manual MS8238C MS8238C DIGITAL MULTIMETER FUNC HOLD RAN NCV TEMP V μa ma 12V 9V 1.5V CAT III COM FUSED 10A 30 sec. every 15 min. 200mA FUSED Autorange Auto power off TEMP maμav CAT III

CONTENTS 1.Overview...1 2. Safety Information...1 2.1 Safety Standards...1 2.2 Precautions...1 2.3 Electrical Symbols...3 3. Description and Usage...4 3.1 Front Panel...4 3.2 Display...5 3.3 Using the Meter...6 3.4 Auto Power Off Function...6 4. Operating Instructions...7 4.1 AC/DC voltage measurement...7 4.2 AC/DC current measurementrent...7 4.3 Resistance measurement...8 4.4 Continuity measurement...9 4.5 Diode test...9 4.6 Battery test...10 4.7 Temperature measurement...10 5. Specifications...11 5.1 General Specifications...11 5.2 Technical Specifications...12 6. Maintenance...15 6.1 General Maintenance...15 6.2 Replacing the Battery and Fuses...16 6.3 Replacing the Probe...16

1.Overview To avoid electrical shock or personal injury, please read all safety information,warnings and precautions before using the meter. The MS8238C is a small, safe and reliable 3 ½ digit handheld auto ranging multimeter.this meter can measure AC/DC voltage, AC/DC current, resistance, diode, continuity, battery test, temperature and non-contact voltage tests.this tool is ideal for professionals and hobbyists alike. 2. Safety Information 2.1 Safety Standards The MS8238C meets standards for CAT III installations and a pollution degree of 2. The protection provided by the meter can only be ensured if all safety procedures are strictly followed. The safety symbols on the meter are to advise of potential dangerous situations.caution is required when measuring close to the meter s safety limits. Never exceed the protection limit values indicated in the specifications for each range of measurement. The special attention should be paid when using the meter because the improper usage may cause electric shock and damage the meter.the safety measures in common safety regulations and operating instruction should be complied with when using. In order to make fully use of its functions and ensure safe operations please comply with the usage in this section carefully. 2.2 Precautions To avoid electrical shock or personal injury, observe and follow all safety precautions Check the meter for damage before use.do not use if any damage is observed. Check the test leads for cracks or exposed wires before using the meter.replace if necessary. Ensure the meter works properly by testing a known voltage source first. If not working properly, the protective equipment may be damaged; have the meter serviced before using. Never measure voltages that may exceed the protection limit indicated on the meter. Always be careful when working with voltages above 60V DC or 30V AC rms. Keep fingers behind the probe barriers when making voltage measurements. Make sure the test leads are in the correct input jacks before measurement. Do not expose the meter to explosive gas, dust or vapor. When connecting the test leads to a measurement circuit, connect the common lead first, then the live lead. Reverse when disconnecting. Turn off power to circuit and discharge all capacitors before making resistance, continuity or diode measurements. In order to avoid incorrect DC voltage readings, check the circuit for AC voltage first, then put the meter in the appropriate DC voltage range. Turn off circuit power and check fuses before connect the leads when measuring current.turn circuit power on after making connection. Never use the meter unless the back cover is in place and fastened securely. 01 02

When the low battery indicator is displayed, replace the battery.the accuracy of the meter cannot be guaranteed while the low battery indicator is on. Before opening the case, always disconnect test leads from all energized circuits. For continued protection against fire, replace fuse only with the specified voltage and current ratings listed in the manual. Measure known voltage with the meter to verify that the meter is working properly. If the meter is working abnormally, stop using it immediately. A protective device may be damaged. If there is any doubt, please have the meter inspected by a qualified technician. 2.3 Electrical Symbols Important safety information. High voltage with danger. Ground. Double Insulation (Class II safety equipment). Fuse must be replaced as per the specification herein. Accord with the related EU laws and regulations AC (Alternating Current) DC (Alternating Current) AC & DC (Both direct and Alternating Current) Conforms to UL STD. 61010-1, 61010-2-030 and 61010-2-033; Certified to CSA STD. C22.2 NO. 61010-1, 61010-2-030 and IEC STD.61010-2-033 CAT III : MEASUREMENT CATEGORY III is applicable to test and measuring circuits connected to the distribution part of the building s low-voltage MAINS installation. 3 Description and Usage 3.1 Front Panel 1 4 5 6 MS8238C DIGITAL MULTIMETER FUNC HOLD RAN NCV TEMP V CAT III μa ma COM FUSED 10A FUSED 200mA 30 sec. every 15 min. 12V 9V 1.5V Autorange Auto power off TEMP maμav 7 8 9 1.LCD display 2.Non-contact voltage (NCV) button 3.Range button 4.Function button 5.Data hold button 6.Rotary switch 7.A input jack 8.Common jack 9.Input jack (all functions except current greater than 200mA) 2 3 03 04

3.2 Display 4 2 3 1 AUTO DC AC 1.AC (alternating current) 2.Polarity indicator 3.DC (direct current) 4.Auto range 5.Data hold 6.Diode measurement 7.Continuity measurement 8.Low battery indicator 9.Reading display 10.Measurement units DATA 9 5 6 7 8 kmω mµva 10 3.3 Button Functions FUNC button: Press FUNC to switch between AC/DC or between functions. HOLD button: Press HOLD to keep the current reading on screen. DATA H symbol will appear on the display. Press HOLD again to release the hold. RAN button: Press RAN to switch to manual range.each press of the button will switch to the next highest range, until reaching the highest range where it will switch to the lowest range. Hold RAN to return to auto range. NCV button: Hold the NCV button down in any mode and the meter will activate the non-contact voltage detection. Hold the meter up to a voltage source and the buzzer will sound and the NCV indicator will light up if voltage is detected. Release the NCV button to stop NCV detection. 3.4 Auto Power Off Function After 15 minutes of non-use the meter will automatically turn itself off. To turn the meter back on, press any button or turn the rotary switch to any position. To deactivate the auto power off function, hold down HOLD when turning on the meter. 05 06

4. Operating Instructions 4.1 AC/DC voltage measurement Set the rotary switch to the AC/DC voltage position. Press FUNC to switch between AC and DC voltage. Connect the red test lead to the input jack and the black Connect the leads to the circuit under test and read the measurement on the display.observe polarity for DC measurements.if OL is display, it means the measurement has exceeded the current range.move the rotary switch to a higher range. Do not measure voltages higher than DC or ACrms to prevent damage to the meter or personal injury 4.2 AC/DC current measurementrent AC/DC current measurement Turn off power to the circuit. Allow all capacitors to discharge. Set the rotary switch to the appropriate AC/DC current range. Press FUNC to switch between AC and DC current. Depending on the current to be measured, connect the red test lead to either the input or 10A jack and the black Break the circuit and connect the leads in series with the circuit (black lead on the lower voltage side). Turn circuit power on and read the measurement on the display.if OL is display, it means the measurement has exceeded the current range.move the rotary switch to a higher range. Never measure open-circuit voltages exceeding between the input terminals and ground to prevent injury or damage to the meter Check fuses before making current measurements. Make sure to use correct input jicks to prevent damage to the meter. 4.3 Resistance measurement Turn off power to the circuit. Allow all capacitors to discharge. Set the rotary switch to the multi-function position. The default function is resistance. Connect the red test lead to the input jack and the black Connect the leads to the circuit under test and read the measurement on the display. Tips for measuring resistance: In-circuit resistance is usually different from a resistors rating due to the fact that the meter s test current flows in parallel with the circuit. For increased accuracy when measuring low resistances, short the test leads, record the value displayed, then connect the leads to the circuit and subtract the shorted value from the circuit measurement. When the leads are disconnected from the circuit under test, OL will be displayed on the screen. To prevent injury or damage to the meter,turn off power to circuit and discharge all capacitors fully before making resistance measurements. 07 08

4.4 Continuity measurement Turn off power to the circuit. Allow all capacitors to discharge. Set the rotary switch to the multi-function position. Press FUNC twice to enter continuity mode. Connect the red test lead to the input jack and the black Connect the leads to the circuit under test.if the measured resistance is less than 30Ω, the buzzer will sound. To prevent injury or damage to the meter,turn off power to circuit and discharge all capacitors fully before making continuity measurements. 4.5 Diode test Turn off power to the circuit. Allow all capacitors to discharge. Set the rotary switch to the multi-function position. Press FUNC once to enter diode mode. Connect the red test lead to the input jack and the black Connect the red test lead to the anode (+) and the black lead to the cathode (-) of the diode and read the measurement on the display. The meter will display OL if the connection is reversed. To prevent injury or damage to the meter,turn off power to circuit and discharge all capacitors fully before making diode measurements. 4.6 Battery test Set the rotary switch to the appropriate battery test range. Connect the red test lead to the input jack and the black Connect the red test lead to the positive (+) end and the black lead to the negative (-) end of the battery and read the measurement on the display. To prevent injury or damage to the meter,do not connect the meter to a battery with a voltage rating exceeding 60V AC or 30V DC 4.7 Temperature measurement Set the rotary switch to the temperature position. Press FUNC to switch between Celsius and Fahrenheit. Connect the positive end of the K-type thermocouple to the input jack and the negative end to the COM jack. Place the tip of the thermocouple to the surface of the object to be tested and read the measurement on the display. To avoid injury or damage to the meter,do not move the rotary switch to the temperture position while measuring voltages exceeding 30V 09 10

5. Specifications 5.1 General Specifications Function Safety Rating Range Operating Altitude <2000m Operating Temperature/ Humidity Storage Temperature/ Humidity Temperature coefficient Max. Input between terminals and earth ground Fuse Protection Sample Rate Display Overload Indication CAT III, pollution degree: II 0~40 C, <80% RH -10~60 C, <70% RH, remove battery 0.1xaccuracy/ C (>18 C or <28 C) DC or AC rms µa/ma ranges: FF 400mA H 10A range: FF 10A H Approx. 3 times/sec. 3 ½ digit LCD display Display shows OL When battery voltage drops below Low Battery Indication normal operating voltage, is shown on the display Polarity Indication Display automatically displays - Power Supply Size(LxWxH) weight DC 9V, NEDA 1604 or 6F22 148x73.5x50mm about 232g 5.2 Technical Specifications : ±(% of reading + digits) at 18 C~28 C with a relative humidity of <80%; guaranteed for a period of one year. 5.2.1 DC Voltage Measuring range 200mV 2V 20V 200V Input impedance: 10MΩ Max. input voltage: DC or AC rms. 5.2.2 AC Voltage Measuring range 2V 0.1mV 0.001V 0.01V 0.1V 1V 0.001V 20V 0.01V 200V 0.1V 1V ±(0.5% of reading +3 digits) ±(0.8% of reading +3 digits) ±(0.5% of reading +5 digits) ±(1.0% of reading +5 digits) Input impedance: 10MΩ Max. input voltage: DC or AC rms. Frequency Response: 40~400Hz, sine wave rms (avg. response) 11 12

5.2.3 Resistance Measuring range 200Ω 2kΩ 20kΩ 200kΩ 2MΩ 20MΩ 0.1Ω 0.001kΩ 0.01kΩ 0.1kΩ 0.001MΩ 0.01MΩ Overload protection: DC or AC rms 5.2.4 Diode Test Function Diode Test Overload protection: DC or AC rms 5.2.5 Continuity Function Rang 1.5V 1mV Description If measured resistance is less than 30Ω, buzzer will sound Overload protection: DC or AC rms ±(0.8% of reading +4 digits) ±(1.0% of reading +4 digits) Description Display shows forward voltage drop Description Open circuit voltage:~0.5v 5.2.6 DC Current Measuring range 200µA 0.1µA 2000µA 20mA 200mA 10A 1µA 0.01mA 0.1mA 10mA ±(0.8% of reading +3 digits) ±(1.0% of reading +10digits) Overload protection: ma jack: FF 400mA H fuse 10A jack: FF 10A H fuse Max input current: ma jack: 200mA DC 10A jack: 10A DC When measuring current exceeding 2A, do not measure for longer than 2 minutes continuously. Wait 10 minutes to continue measurement. 5.2.7 AC Current Measuring range 200µA 0.1µA 2000µA 1µA 20mA 200mA 10A 0.01mA 0.1mA 10mA ±(1.0% of reading +3 digits) ±(1.2% of reading +3digits) ±(1.5% of reading +10digits) Overload protection: ma jack: FF 400mA H fuse 10A jack: FF 10A H fuse Frequency Response: 40~400Hz, sine wave rms (avg. response) Max input current: ma jack: 200mA AC rms 10A jack: 10A AC rms 13 14

When measuring current exceeding 2A, do not measure for longer than 2 minutes continuously.wait 10 minutes to continue measurement. 5.2.8 Temperature Position -20~750 C 1 C -4~1382 F 1 F Overload protection: FF 400mA H fuse 5.2.9 Battery Test Position 12V 0.01V 9V 0.01V 1.5V 0.001V 6. Maintenance 6.1 General Maintenance This section provides basic information on maintaining the meter, such as replacing fuses and the battery. Only experienced and authorized personnel should make repairs to the meter. To avoid injury or damage to the meter,do not allow moisture inside the case and remove test leads before opening battery cover Use a damp cloth to regularly clean the outside of the meter.do not use abrasives or chemical solvents.dirty or damp input jack can adversely affect readings. To clean input jacks, follow the following steps: 1.Turn off the instrument and remove the test leads. 2.Clear any dirt or other particles on the input jacks. 3.Use a cotton ball/swab with a lubricant (i.e. WD-40) to clean off the contacts of the input jacks. 4.Use a separate cotton ball/swab for each jack to prevent cross-contamination. ±(2.0% of reading +2 digits) ±(2.0% of reading +4 digits) 6.2 Replacing the Battery and Fuses Overload protection: FF 400mA H fuse ±(0.8% of reading +7 digits) ±(0.8% of reading +7 digits) ±(3.0% of reading +5 digits) 1. Under normal conditions, it is unnecessary to replace the fuse. Don't replace it until the probes are unplugged and the power is shut down. Take out the two screws of the rear cover to remove the housing. 2. The specification of the fuse is: F1 F 10A H, F2 F 400mA H The replacement should be of the same specification. 3. The battery for this multimeter is 9V NEDA 1604 or 6F22. The replacement should be of the same specification. 4. Don't put the instrument into use until the rear cover is screwed after replacing battery or fuse. Warning To avoid electric shock, make sure the probes are disconnected from the measured circuit before removing the rear cover. Make sure the rear cover is tightly screwed before using the instrument. 6.3 Replacing the Probe If insulation on probe is damaged, replace it. Use meet EN 61010-031 standard, rated CAT III, 10A or better probe. 15 16

R-00-05-1568