NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Similar documents
NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

RS-485 FClink Networking Room Thermostats with LCD for Fan Coil Units

RS-485 Modbus RTU Networking Room Thermostats with LCD for Fan Coil Units

RS-485 Modbus RTU Networking FCU Thermostats with 0(2)-10 VDC Fan Output

BACnet Product Overview

BACnet MS/TP Gateways for Mega Controls Modbus RTU Networking Devices

BACnet-over-Ethernet (BACnet TCP/IP) Gateways for Modbus RTU Devices

Field selectable application type and room module series, via dip-switches on controller

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

FCU-4 FAN COIL CONTROLLER

RCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

RCF-230CTD. Room controller for fan-coil applications with outputs for two thermal or one 3-position actuator or function for an electric heater

TC-9102 Terminal Controller

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

IntesisBox PA-AW-MBS-1 v.2.0

MOD-RI Room Interface Modules with Modbus

Temperature controller Ducted systems

ECL Comfort V a.c. and 24 V a.c.

BA/BS4S Temperature Sensor Installation & Operating Instructions

FCU-4 FAN COIL CONTROLLER

RTD-RA. realtime. Installation Instructions. English A B. Installation Instructions Control Systems LEDS ALL DIMENSIONS IN MM

Evolution TH. Pre-configured controller with display, clock and communication. Evolution. Applications. TH version. Sensors

HLS34 Modbus FCU/VAV Controllers installation instructions

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Networkable Dual Duct VAV Controller Specification and Installation Instructions

TC-8900 Controller Units with PM-8900 Power Modules

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Precision humidity/temperature sensing/control

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

Carbon Monoxide Sensor - ModBus

LLR-MOD Modbus Light Level and Occupancy Sensor

THERMOSTATS & CONTROLLERS

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

FCU-MULTI Modbus Fan Coil Unit Controller

TLR-D42 with OPA-D42 Intelligent PI fan coil controller for modulating actuators. Cabinet mounted base, wall mounted operation terminal.

Millennium Simplicity Elite Parameter Points and Quirks

Measure & Control Temperature & CO2 levels with analog & digital I/O

P216. Condenser fan speed controller. Product bulletin. Features

clarity 3 Programmable Controller

HARDWARE GUIDE. VAV Zone Controller C1000 Series. Specifications and Operational Guide

Pre-programmed room controller with display and communication

FX Input/Output (I/O) Modules XM07 and XM14

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

SE7600E Series Application Guide

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Fast Route to Reliable Energy Savings ZIP Economizer

Pre-programmed room controller with display and communication

Siemens BACnet Programmable TEC Unit Conditioner Controller

CDR Room CO 2 and Temperature Sensor with Modbus

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

TF243 Series Digital Thermostat Fan Coil Unit Control

CONTROLLER INSTALLATION OPERATION & QUICK START

ECON-ZIP-BASE. ZIP Economizer Base Module

BAPI-Stat 4MB Modbus Temp or Temp/Humidity Sensor

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

Room controller STRA-17

RC-CDTO. Pre-programmed room controller with display, communication and three-point control

SE7600E Series Application Guide

BACnet Flow Controller for Fan Filter Units

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

TER-MOD Active Room Temperature Sensors (Controllers) with Modbus

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

IntesisBox ModBus RTU Fujitsu Air Conditioning

MicroTech Unit Ventilator Controller

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Networkable VAV Controller Specification and Installation Instructions. Controller Model EVCB14NIT4X (4 TRIACS / independent / external motor)

SUPERVISION AND CONTROL FOR HYDRONIC TERMINAL UNITS

BACnet MS/TP Interface User s Guide

Non-communicating room controllers

Room Temperature Controller

Master room unit for RRV controllers

STRA-17 Room controller. Installation and maintenance manual. Content

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

MANUAL INSTALLATION + SERVICE. Price Intelligent Controller. PIC Series. v400 Issue Date: 12/18/ Price Industries Limited. All rights reserved.

BACnet Integration Manual September 1, 2010

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

RHR-MOD Combined Room Temperature and Humidity Sensors (Controllers) with Modbus

Communicating Thermostats. Add More Flexibility to Building Automation with. Communicating Thermostats

Temperature Controller (Heat Pumps)

RWD68U Universal Controller

FXVMA Variable Air Volume (VAV) Box Controller

FX06 Field Controller

Room Temperature Controller

SEZ7260X5x45B Installation Guide for BACnet MS/TP Zone Controller

Technical data sheet

WE TAKE BUILDING AUTOMATION PERSONALLY MANUAL RCF

P216 Series Condenser Fan Speed Controller

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Controllers / Automation Stations U-DDC

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Transcription:

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat Features Modern Appearance Stylish rotary dial and buttons Large LCD with backlight Support Modbus RTU protocol Support standalone operation on RS485 communication failure Retention of temperature set-point and fanspeed upon power failure Unoccupied mode contact for energy-saving 2-wire on-off, 0-10 VDC and 3-wire floating models Dual-output model provides auto cooling/ heating changeover with adjustable deadband or/and manual override PI Algorithm (modulating models) Parameter setup manual Remote temperature sensor capability Seasonal changeover sensor availability Optional remote controller Additional Binary Input Extendibility to BACnet network with our BACnet MS/TP Gateway module (BMG) Selectable Functions Selectable ºC or ºF temperature display Field selectable program to retain last operating event upon power failure Measured temperature off-set Selectable P-band and I-time Selectable Actuator stoke time (3-wire floating model) Field selectable 1 to 5 K deadband for dualoutput models Field adjustable high and low set point limit Field adjustable cooling and heating energy saving mode set points Selectable fan action in unoccupied mode Selectable Auto Fan sequence in heating mode Selectable operating mode sequence for dual-output models Selectable manual/auto operating sequence for single output models Selectable constant display of temperature between sensing or set-point General The NT50 Series RS485 Modbus RTU networking LCD Fan Coil applies communication technology of Modbus RTU master/slave protocol to monitor and supervise year around air conditioning units in commercial, industrial and residential Installation. Typical application includes the control of fan coil units, packaged terminal air conditioners and combination heating and cooling equipment, as part of the system that consists of two-way or three-way valve and a multispeed line voltage fan. The maximum number of NT50 slaves in a Modbus RTU network is 32. Optional BACnet MS/TP Gateway module (BMG) is available for order. It works as an interface to link up the NT50 thermostats with BACnet MS/TP communication bus. Please refer to the product bulletin of BMG BACnet MS/TP Gateway for details. Ordering To order the NT50 Series thermostat, contact the nearest Cyrus representative. Specify the desired product code number from model selection guide. E026-1301 1

Product Overview The NT50 are line voltage RS485 Modbus RTU networking LCD thermostat with 5 basic models that cover all type of FCU applications. There are models for cooling only, heating only and heating/ cooling fan coil system integrate with 2-wire, 0-10 VDC or 3-wire input valve control. On-board high accuracy NTC sensor allows precision comfort control over occupied space area. The display temperature offset for the built-in temperature sensor will be compensated after being energized for approximately 15 minutes. 86 x 86mm size of NT50 allows for 75 x 75 x 35 mm standard wall box installation. Model NT50-1 The Model NT50-1 is a line voltage RS485 Modbus cooling only / heating only fan coil unit with 2-wire onoff valve actuator application. Integral with system of Cooling/Heating-Fan-Off button that allows users to cutoff power for fan and the output for valve actuator. It allows to select the fan speed simply by pressing the fan button. All fan outputs by relay that can withstand max. of 3 Amp (resistive) 1 Amp (Inductive) operating current. Model NT50-1F The Model NT50-1F is a line voltage RS485 Modbus cooling only / heating only fan coil unit with 3-wire floating valve actuator application. Integral with system of Cooling/Heating-Fan-Off button that allows users to cutoff power for fan and the output for valve can withstand max. of 3 Amp (resistive) 1 Amp Model NT50-1A The Model NT50-1A is a line voltage RS485 Modbus cooling only / heating only fan coil unit with 0-10VDC input valve actuator application. Integral with system of Cooling/Heating-Fan-Off button that allows users to cutoff power for fan and the output for valve can withstand max. of 5 Amp (resistive) 2 Amp Model NT50-2 The Model NT50-2 is a line voltage RS485 Modbus cooling and heating fan coil unit with 2-wire on-off valve actuator application. Integral with system of Cooling/Heating/Auto-Fan-Off button that allows users to cutoff power for fan and the output for valve can withstand max. of 3 Amp (resistive) 1 Amp Model NT50-2A The Model NT50-2A is a line voltage RS485 Modbus cooling and heating fan coil unit with 0-10 VDC input valve actuator application. Integral with system of Cooling/Heating/Auto-Fan-Off button that allows users to cutoff power for fan and the output for valve can withstand max. of 5 Amp (resistive) 2 Amp Model Selection Guide NT5 0-2A - R Power 0 = 100-250 V, 50/60 Hz 0 Valve Control Output 1 = 2-wire on-off (Heating only or Cooling only2-pipe) 1F = 3-wire floating (Heating only or Cooling only 2-pipe) 1A = 0-10 VDC (Heating only or Cooling only2-pipe) 2 = 2-wire on-off (Heating / Cooling 4-pipe) 2A = 0-10 VDC (Heating / Cooling 4-pipe) 2A Options & Color Compliance Nil = Grey Faceplate W = White Faceplate 2 R = IR Receiver for Remote Controller R

LCD Segments and Buttons Operation Notes Temperature Display Backlight LCD shows measured temperature constantly except when temperature set point adjustment is being made The backlight will light up for 5 seconds when any button is pressed Mode of operation Press the system control key to enter into the desired operating mode: Cooling-Heating-Auto-Fan Only-Off Fan speed Press the fan control key to change the fan speed mode: High-Med-Low-Auto Temperature Set-point Unoccupied Mode (Energy-saving) Increase or decrease temperature set point by rotating the adjustment dial clockwise or counterclockwise. When the dial is rotated, the LCD shows the set point temperature The energy saving mode is activated while OCU contact is in closure. In unoccupied mode, the factory temperature set points are 26 o C and 16 o C for cooling and heating respectively. Fan speed is always set at low. Parameter setup menu The thermostat allows authorized service agents to change certain number of operating parameters, please refer to parameter setup manual for details. Dimensions in mm Remote Controller 3

Network & Cabling Requirements To ensure network stability and reliable communications, particularly at high speeds on a BACnet MS/TP or Modbus RTU network for a number of devices, it is imperative that the following network and cabling requirements are adhered to: Item Cabling Topology Maximum Nodes Terminator Repeater Description For BACnet MS/TP and Modbus RTU networks, it is recommended to use networking cabling that matches the following specifications: Balanced 100 to 120 ohms nominal impedance, 22 or 24 AWG Twisted Shielded Pair (TSP) Cable Nominal capacitance of 52 pf/m or lower Nominal velocity of propagation of 66% or higher Ensure the MS/TP or Modbus RTU network cable is installed as a daisy chain from one device to the next. The maximum number of devices per MS/TP or Modbus RTU network without any repeaters is 32. A terminator of 120-ohm impedance must be installed at each end of each MS/TP or Modbud RTU network segment, or two per MS/TP or Modbus RTU network. Ensure that this requirement is not overlooked in laying out the network architecture and ordering product. A repeater is not necessary unless the MS/TP or Modbus RTU network is extended beyond 1,000 m. Network Configuration To a BACnet MS/TP Network Supervisor BMG (Master) BACnet MS/TP Network BMG (Master) BACnet MS/TP Network Notes: 1. Ensure the recommended balanced cable is used. 2. Ensure the cable is installed as a daisy chain from one device to the next (1,000 m maximum) and the shield is grounded at one single point of the network only. 3. Ensure a MS/TP terminator is installed on each end of each MS/TP network. 4. The maximum nodes per MS/TP network is 32 without a repeater. Modbus RTU Network Notes: 4 RS485 Modbus RTU Network NT50 NT50 NT50 NT50 Slaves 1. Ensure the recommended balanced cable is used. 2. Ensure the cable is installed as a daisy chain from one device to the next (1,000 m maximum) and the shield is grounded at one single point of the network only. 3. Ensure a terminator is installed on each end of each or Modbus RTU network. 4. The maximum nodes per Modbus RTU network is 32

Wiring Diagrams and Application Notes Cut jumper JP1 open if an external sensor is wired to SR1 and GND. Run the wiring away from any electrical motors or power wiring. Failure to do so may result in poor thermostat performance due to electrical noise. 22 or 24 AWG twisted shielded pair double-insulated cable is recommended as remote sensor wiring and its length must not exceed 25 m. Do not bundle and run power wiring and remote sensor wiring in the same conduit. The seasonal changeover sensor should be wrapped around the supply water pipe when associated with a water system. When the changeover sensor temperature exceeds 30 ºC, the thermostat enters into heating mode. External seasonal changeover sensor or switch is applicable to heating only or cooling only 2-pipe models only. OCU contact closure activates unoccupied mode. The thermostat 2-wire and 3-wire valve control outputs are designed for controlling zone valves. If used for controlling electric heaters, external contactors must be used. Hidden-line wiring for Terminal 7 of CN6 are applicable to dual-output model and 3-wire model only. On a single-output unit, V1 can be either a 2-wire spring-return cooling or heating valve. On a dual-output unit, V1 must be a 2-wire spring-return cooling valve and V2 a 2-wire spring-return heating valve. For a 3-wire floating output model set in cooling mode, Terminal 6 of CN6 is wired to open valve on temperature rise and Terminal 7 of CN6 to close valve on temperature drop. The action in heating mode is reversed. On a single-output unit, V4 can be either a 0-10 VDC cooling or heating valve. On a dual-output unit, V4 must be a 0-10 VDC cooling valve and V5 a 0-10 VDC heating valve. JP4 is available for 0-10 VDC models. Cut it if 2-10 VDC control signal is required. It s recommended to set the P-band to 1K and I-time to 0 min if the NT50-1F is used for on-off output. WARNING Incorrect wiring connection may cause permanent equipment damages to the thermostat. NT50-1 / NT50-2 NT50-1F Sensor connections For all models V1 and V2 are 2-wire on-off spring-return valves V3 is a 3-wire floating valve NT50-1A / NT50-2A V4 and V5 are 0-10 VDC valves CN2, CN3, CN6 socket and setup jumpers are located at the back of the PCB of the LCD unit 5

Jumper settings NT50-2 and NT50-2A can be re-configured in the field to various models by a qualified servicing agent, if necessary, by resetting the jumper positions of JP2 and JP3. The location of the jumpers will be found after removing the thermostat cover from its baseplate. Model Number Jumper Settings JP2 JP3 NT50-2 Uncut Uncut NT50-2A Uncut Uncut NT50-1F Cut Uncut NT50-1 Cut Cut NT50-1A Cut Cut CN2 V1+ Gnd V2+ 485+ 485- CN1 CN3 SR2 GND DI1 OCU SR1 Technical Specifications Product Model Power Requirements Operating Temperature Differential (for 2-Wire On-Off Models) See NT50 Series Model Number Selection Guide 100...250 V, 50/60 Hz Fixed at 1 K for both cooling and heating modes Temperature Display Range 5-35 º C in 0.5 K increments: accuracy ±1 K (41-95ºF in 0.5 R increments, accuracy ±1 R) Temperature Set Point Range Deadband of Dual-Output Models Auto Fan Temperature Differential Sensing Element Unoccupied Mode Additional Binary Input RS-485 Communication Speed 5-35 º C in 0.5 K increments, initial factory setting at 22 º C (41-95ºF in 0.5 R increments) 3 K (Adjustable 1 to 5 K in setup menu) At 2 K (2 R) increments. At >0 K, fan is on low speed in cooling mode and fan status in heating mode depends on auto fan action selection setting. NTC thermistor, 10 kω@25ºc; accuracy ±0.5 K@25ºC Input signal from external voltage-free contact Baud rate fixed at 19200 bps Device MAC Addressing 01-32 via parameter setup menu, factory set address 01 Modbus RTU Network Guideline Body Material Finish Electrical Ratings Maximum 32 devices and maximum 1,000 m cable length Self-extinguishing, molded ABS Off white body / grey face plate (white face plate is available up on request) 2-wire and 3-wire models Valve output relays 100-250 V, 3 A resistive, 1 A inductive, 50/60 Hz Fan output relays 100-250 V, 3 A resistive, 1 A inductive, 50/60 Hz Total rating 100-250 V, 5 A maximum, 50/60 Hz 0-10 VDC models Valve output impedance Minimum 10,000 Ω Fan output relays 100-250 V, 5 A resistive, 2 A inductive, 50/60 Hz Total rating 100-250 V, 5 A maximum, 50/60 Hz Ambient/Storage Temperature Limits Connections Power Wires Sensor Wires Agency Approval Shipping Weight Dimensions 0 to 50 o C / -30 to 50 o C, 10% to 90% RH non-condensing Non-removable terminal blocks Wire size 1 mm 2 or 18 AWG solid copper recommended 22 AWG twisted shielded pair double-insulated cable CE Mark compliant to EMC and low voltage directives 350 g See Dimensions drawing in mm The specification above are normal and conform to generally acceptable industry standard. Cyrus is not responsible for damages resulting from misapplication or misuse of its products.