INTEGRATED BUILDING ENERGY AND LIGHTING SIMULATION IN THE FRAMEWORK OF EU PV LIGHT PROJECT

Similar documents
Daylighting. Note: Daylight is typically defined as diffuse light and is very different from sunlight (direct solar radiation).

A lighting simulation tool for the new European daylighting standard

A SIMPLE METHOD OF DETERMINING THE INFLUENCE OF THE OVERHANG ON WINDOW SOLAR GAINS

J. Alstan Jakubiec Jeff Neimasz Modeling Dynamic Shading Devices with the DIVA Advanced Shading Module 1 / 30

RECENT ADVANCES IN SIMULATION-POWERED BUILDING SYSTEMS CONTROL

Control of an Adaptive Light Shelf Using Multi-Objective Optimization

Abstract. Introduction. Dynamic lighting simulation

ENCLOSURE SYSTEMS DESIGN AND CONTROL SUPPORT VIA DYNAMIC SIMULATION-ASSISTED OPTIMIZATION. Vienna, Austria. Bangkok, Thailand

Ecotect is not intuitive. Finding the location of the tools and their purposes is very difficult and time consuming.

DAYLIGHTING SIMULATION OF JAPANESE ARCHITECTURE USING ALL SKY MODEL

EFFECTS OF EXTERNAL SHADING DEVICES ON DAYLIGHTING AND NATURAL VENTILATION

Practical use of new visual discomfort probability index in the control strategy for solar shading devices Johnsen, Kjeld

Parametric Daylight Envelope: shading for maximum performance

Integrated Thermal and Light Simulations for Complex Daylight Systems Using TRNSYS and RADIANCE

DESIGN SUPPORT SIMULATIONS FOR A DOUBLE-SKIN FAÇADE

GOAL-BASED DAYLIGHTING DESIGN USING AN INTERACTIVE SIMULATION METHOD

Empirical Validation of IES<VE> Simulation in Term of Daylight in Self- Shading Office Room in Malaysia

Prediction of vertical irradiance on building surfaces: an empirical comparison of two models

ARCH 447 Electrical Services - Lighting

Daylight Performance of Subdivided Windows with Automatic and Manual Shading Devices

Shading Calculation for Passive House Certification Discussion and Development of a New Method

BUILDING INTEGRATED PHOTOVOLTAICS IN A THERMAL BUILDING SIMULATION TOOL

version: 3/16/2009 A Design Sequence for Diffuse Daylighting Tiffany Otis Christoph Reinhart Harvard Graduate School of Design

Development Of A Fast Simulation-aided-design Method For Office Building In Early Design Stage Ziwei Li 1, Borong Lin 1,*, and Hongzhong Chen 1 1 Scho


GENETIC OPTIMIZATION OF EXTERNAL SHADING DEVICES

A model study of the daylight and energy performance of rooms adjoining an atrium well

Lighting/Daylighting Software Current State of the Art Report

Atrium Design Strategies for Daylighting and Natural Ventilation

IMPLEMENTATION AND APPLICATION OF A NEW BI-DIRECTIONAL SOLAR MODELLING METHOD FOR COMPLEX FACADES WITHIN THE ESP-R BUILDING SIMULATION PROGRAM

POTENTIAL FOR VIRTUAL DAYLIGHT SENSORS USING DAYLIGHT SIMULATION AND HIGH-RESOLUTION MEASUREMENT OF SOLAR RADIATION

A Simulation-Based Expert System for Daylighting Design

solar energy. compared be able to with a low skyscrapers. buildings Solar The the room when the the sky, higher good view

A Parametric Analysis for the Impact of Facade Design Options on the Daylighting Performance of Office Spaces

Reliable, fast and intuitive daylight simulation for 3D architectural and urban models directly integrated within SketchUp graphic modeler

Comparative Daylight Glare Analysis Between Measured and Computer Simulation Predictions

DAYLIGHTING OPTIMIZATION IN SMART FAÇADE SYSTEMS.

Combined Daylight and Thermal Calculation Tool for Annual Energy Performance Simulation of Rooms with Advanced Daylight-Controlled Lighting Systems

Assessing thermal comfort near glass facades with new tools

Development of an Advanced Radiation Exchange Module for Use in Simulation of Spaces with Radiant Systems

Evaluating solar irradiance on urban sites by superimposing Radiance pictures

DYNAMIC DAYLIGHT GLARE EVALUATION. Jan Wienold 1.

Energy Efficient Configuration of Non-Conventional Solar Screens Using Hybrid Optimization Algorithm

Thermal Design Tool for Outdoor Space Based on a Numerical Simulation System Using 3D-CAD

Dynamic facade module prototype development for solar radiation prevention in high rise building

EUROPEAN RESEARCH PROJECT RE-VIS, DAYLIGHTING PRODUCTS WITH REDIRECTING VISUAL PROPERTIES

COOL-COVERINGS. André Santos, The Netherlands Copyright Active Space Technologies

A guide for the building of daylight scale models

ApacheSim User Guide <Virtual Environment> 6.0

Thermal modelling of complex fenestration systems Comparison of a BSDF-based model with simplified approaches

High-resolution spatial and electrical modeling for efficient BIPV system design

Dynamic daylight simulations for façade optimization (and some other applications)

SunCast - User Guide. IES Virtual Environment 2013

EVALUATION OF OVERHEATING PROTECTION WITH SUN-SHADING SYSTEMS

Formulating an Alternative Methodology for Singapore s Envelope Thermal Transfer Value Calculation Accounting for non-conventional shading strategies

Priority for School Buildings Programme

Module 5: Video Modeling Lecture 28: Illumination model. The Lecture Contains: Diffuse and Specular Reflection. Objectives_template

Radiance workshop 2012

INTRODUCTION 1. SIMULATION MODELS Physical Modelling

CONVR 2006 Application of 3D Modeling Software for Daylighting Simulation of Shading Devices

Table of Contents

Methods for integrating parametric design with building performance analysis

Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chambéry, France, August 26-28

ISSN: [Chenglin* et al., 6(5): May, 2017] Impact Factor: 4.116

Access from the University of Nottingham repository: unmarked.

Calculation Methods. IES Virtual Environment 6.4 CIBSE Heat Loss & Heat Gain (ApacheCalc)

XENOTEST 220/440. Light Exposure and Weathering Testing Instruments

Using Daylighting Performance to Optimise Façade Design. Colin Rees Consultancy Manager

SIMULATION OF DAYLIGHT PERFORMANCE OF BUILDINGS BY THE DAYLIGHT SOURCE MODEL BASED ON GEOSTATIONAL METEOROLOGICAL SATELLITE IMAGES

Journal of American Science 2015;11(11)

POSSIBILITIES AND CHALLENGES CREATED BY A SMART MATERIAL IN BUILDING PERFORMANCE SIMULATION

Development and Validation of a Radiance model for a Translucent Panel

Final Report. Abstract

By Helmut Kientz, R.A. Hixson Design & Illustration

CHAPTER 5. Special Cases

Window shades: selecting optical properties for visual comfort

Coupling dynamic energy and daylighting simulations for complex fenestration systems

space is used effectively. Outdoor space components such as fences and trees affect the solar radiation that the building receives. These components a

Application Note - How to Simulate a SolarEdge System in PVsyst

5.1 Exercise: Daylighting Analysis of a Single Office

Guideline to Daylight Simulations in LightStanza with MicroShade. Simulation of MicroShade in LightStanza. About MicroShade.

Window Material Daylighting Performance Assessment Algorithm: Comparing Radiosity and Split-Flux Methods

Daysim 3.0 DDS, New Validation Study

IES <Virtual Environment> Tutorial RadianceIES (Version 6.0)

A PARAMETRIC STUDY ON WINDOW-TO-FLOOR RATIO OF DOUBLE WINDOW GLAZING AND ITS SHADOWING USING DYNAMIC SIMULATION

Development of Optimal Design System based on Building Information Modeling

The importance of software's and weather file's choice in dynamic daylight simulations

urban context Darren Robinson Group Leader: Sustainable Urban Development / EPFL Visiting Professor: Technical Research Centre of Finland / VTT

Room controller LS 990 / LS plus Stainless Steel / Aluminium

DETAILED MODELING OF COMPLEX BIPV SYSTEMS

Simulating Complex Window Systems using BSDF Data

Application Note. Measuring the Geometric Attributes of Your Products AN

VALIDATION OF VELUX DAYLIGHT VISUALIZER 2 AGAINST CIE 171:2006 TEST CASES

Environmental Controls

SIMULATION OF TUBULAR DAYLIGHTING DEVICES AND DAYLIGHTING SHELVES IN ENERGYPLUS

METHODOLOGY FOR NATURAL VENTILATION DESIGN FOR HIGH-RISE BUILDINGS IN HOT AND HUMID CLIMATE

Bifacial PV Performance Models: Comparison and Field Results

BSRIA Air Conditioning Worldwide Market Intelligence

The benefits of FEM-SS-BES (Finite Element Method, State-Space, Building Energy Simulation) modeling exchange for building physics

INCORPORATING SKY LUMINANCE DATA MEASURED BY EKO SCANNER WITH A SCANNING SKY SIMULATOR FOR PREDICTING DAYLIGHT QUANTITY IN BUILDINGS

Transcription:

Eleventh International IBPSA Conference Glasgow, Scotland July 27-30, 2009 INTEGRATED BUILDING ENERGY AND LIGHTING SIMULATION IN THE FRAMEWORK OF EU PV LIGHT PROJECT Milan Janak 1 and Reinhard Kainberger 2 1 Slovak University of Technology, Civil Engineering Faculty, Department of Building Constructions, Radlinského 11, 813 68 Bratislava, Slovakia E-mail: milan@svf.stuba.sk, Tel: +421 2 59274 459, Fax: +421 2 52920 482 2 TAS Bauphysik, Welser Straße 35-39, 4060 Leonding, Austria E-mail: r.kainberger@tas-bauphysik.com, Tel: 0732 / 67 51 67-0, Fax: 0732 / 67 51 67-5 ABSTRACT In the paper we describe an integrated building lighting and thermal simulation activities carried out in the support of EU PV-Light Project. A part of the project has focused on an experimental quantification of a moveable PV solar shading façade modules fitted to the external test cells. An experimental data has been used to calibrate building energy and daylighting simulation models. The calibrated integrated building energy and daylighting models have been used to carry out a multiple runs with the different facades options under a range of the European climate conditions. The simulations have focused on the prediction of building heating, cooling and lighting demands that are used to assess an individual PV façades performance. INTRODUCTION The goal of the simulation work described in this paper was to evaluate three different types of moveable PV shading devices that should mainly be used for office buildings. It was examined how these different types influence the energy consumption of typical office room especially in cooling, heating energy and the energy needed for artificial lighting. The solar shading and daylight effects of these devices were simulated with global illumination simulation tool Radiance (Ward, 1992). The results of these pre-calculations were used for the whole building energy simulations using the simulation tool ESP-r (Clarke, 2001). This simulation algorithm for both light and energy was calibrated by a comparison with experimental measurement results. These measurements were carried out on the ZSW test area in Widderstall (Germany). The method used in this simulation work is the one described in details in (Janak, et. al. 1997, 1999 and 2003). The solar shading effect direct and diffuse (i.e. global vertical irradiance) of the moveable PV external shading devices on the building energy model has been pre-calculated with the global illumination tool Radiance on the hourly bases as described in (Janak, 2003). The artificial electrical lighting energy demand and resulting casual heat gains where simulated with the method of direct conflation between Radiance and ESP-r as described in (Janak, et. al., 1999). MOVEABLE PV SHADING DEVICES Three Louvers Canopy System model 1 The figure 1 shows the side view of this canopy system. The figure shows the zero-position (horizontal) for the overcast sky conditions. For clear sky the louvers are perpendicular to the sun position (in the vertical projection). The louvers are more or less completely covered with PV cells imbedded in a transparent plastic foil. (look at right picture of figure 4) This system is intended to be used for façades with windows and parapets. Figure 1 A section view of 3 louver canopy system Synchronous Tracking Louvre (STL) model 2 Figure 2 above shows the STL system. In the zeroposition for overcast sky conditions all louvers are horizontal. For clear sky the louvers are perpendicular to the sun position (in the vertical projection). The lower part of the single louvers contain the PV cells (opaque region) the upper part is a clear transparent foil. This system is intended to be used for the rooms with high glass facades. Counter Tracking Louvre (CTL) model 3 Figure 3 below shows the CTL system. At overcast sky condition the system goes into the position as drawn in the figure. For clear sky the louvers are perpendicular to the sun position (in the vertical projection). The PV louver is more or less completely covered with PV cells imbedded in the transparent foil and - 1671 -

the counter louver is a shading device covered with the foil with a light diffusing fabric inlay (see left figure 4.) Foil: T S = 0.73 T L = 0.78 T S and T L = 0.06 Figure 2 A section view of synchronous tracking louvre T S : solar transmittance T L : light transmittance Figure 4 PV louvre and the fabric of the counter shading panel The PV louver is more or less complete covered with PV cells imbedded in a transparent foil and the counter louver is a shading device which is a foil with a light diffusing fabric inlay. EXPERIMENTAL MEASUREMENTS AND MODEL CALIBRATION In order to compare the lighting and energy simulation models and approaches two containers were installed on the solar test field of ZSW (see figure 5). On one of the two containers the CTL system was installed, that is the most complex system for simulation. The second container was used for calibration of the container model only and there was no shading device installed. Illuminance and temperature sensors were placed in both boxes and weather data (temperature, solar radiation and wind) were measured at the site. Measurement data are available from 11.10.2006 to 12.12.2006 where two different container orientations have been evaluated. Figure 3 A section view of counter tracking louvre Figure 5 Containers without and with CTL moveable PV louvre shading panels Figure 6 shows an example of the measured and simulated illuminances at the sensors L13 (4.36 m behind the façade) over two simulated and measured days (container without shading device). At hour 17 there is visible the typical effect of the random clouds movement that can not be captured with the current mean sky models (Perez, 1999) that has been used as the boundary condition for daylighting simulations. Figure 7 shows the similar results for the case with container with moveable PV shading device. Figure 8 and figure 9 show comparison of measured and simulated container mean air temperature. For this configuration the simulated values are about 1 C - 1672 -

lower than the measured values for both the shaded and the not shaded container. Illuminance (lx) Room air temperature ( o C) 7000 6000 5000 4000 3000 2000 1000 0 Measured L13_Ovl Simulated L13_Ovl 1 4 7 10 13 16 19 22 25 28 31 34 37 40 43 46 49 Time (h) Figure 6 Comparison of measured and modelled illuminance in not shaded container Figure 7 Comparison of measured and modelled illuminance in shaded container 50 45 40 35 30 25 20 15 10 5 0-5 Period: 18.11.2006-24.11.2006 1 25 49 73 97 121 145 169 Tim e (h) 1d=24h; 7 days Measured average in 90 and 180 cm Simulated Figure 8 Comparison of measured and modelled air temperature in not shaded container Room air temperature ( o C) 50 45 40 35 30 25 20 15 10 5 0 Period: 18.11.2006-24.11.2006-5 1 25 49 73 97 121 145 169 Time (h) 1d=24h; 7 days Measured average in 90 and 180 cm Simulated Figure 9 Comparison of measured and modelled illuminance in the shaded container OFFICE MODELS AND SIMULATIONS For the described shading devices simulation models for daylighting and thermal calculations were created using the algorithm described. These shading devices were integrated into thermal and daylighting models of the typical office rooms. These virtual offices were located into two climates, one typical middle European (Berlin) and one typical south European (Madrid) climate in order to predict the energy demand for heating, cooling and artificial lighting. Additionally these calculations have been done for two office orientations (south and west orientation). General Boundary Conditions Office size: façade width: 3m; room depth: 5 m; room height: 2.8 m Parapet height: 0.8 m (only for 3 louvers canopy system) Fabric Framing: aluminium construction with U f = 2.0 W/(m²K) Glass: U g = 1.2 W/(m²K); SHGC = 0.6 Internal walls: gypsum plasterboard walls with 5 cm insulation inside Ceiling: suspended gypsum board ceiling below concrete ceiling Floor: carpet on concrete and impact noise insulation Parapet: U = 0.3 W/m²/K; concrete with exterior insulation Heating and cooling set points: 21 C and 26 C (weekends 18 C / 30 C) Ventilation Mechanical air exchange rate 1/h during 6 a.m. to 6 p.m.; 60 % heat recovery Infiltration rate 0.1/h during night and weekends Internal heat gains 1 person 1 computer (150 W sensible heat) light (10 W/m²) = 150 W Control of light On/off control: set point 250 lx on the table in 3 m distance of the façade. Heating, cooling and electric lighting energy Values for the energy demand per m² office area and year vary with climate and orientation 3 louvers canopy system model 1 cooling demand 26 53 kwh/(m².a) heating demand 0-13 kwh/(m².a) electric light demand 6 11 kwh/(m².a) Synchronous tracking louver model 2 cooling demand 2 15 kwh/(m².a) heating demand 17 55 kwh/(m².a) electric light demand 9 14 kwh/(m².a) Counter tracking louver model 3 cooling demand 0 5 kwh/(m².a) - 1673 -

heating demand 35 64 kwh/(m².a) electric light demand 16-21 kwh/(m².a) All demands are transferred to energy by using a simple conversion factor in order that the models could be inter compared. The spread of the values is again varying with the climate and the office orientation: model 1-64 73 kwh/(m².a) model 2-53 101 kwh/(m².a) model 3-88 120 kwh/(m².a) These figures are of course the theoretical values and could be used only for model relative inter comparison. VISUAL COMFORT For the design of a typical visual display terminal working environment the following rules could be considered for the assessment: 10 : 1 - criterion: In the view of the person in front of the monitor there should be no surfaces which are brighter the 10 times the mean luminance of the computer screen. That means for example about not more than 850 cd/m² for typical windows desktop. 3 : 1 - criterion Surfaces which are very close to the screen (keyboard, paper beside keyboard, table surface, ) should not have a higher luminance than 3-times the mean luminance of the screen (again approximately. not more than 250 cd/m² for typical windows application). This criterion is also valid for reflections directly on the screen from other surfaces. The Radiance models for the office with visual display terminal LCD monitor were used to demonstrate the glare situation in the office environment with PV shading devices. Luminance pictures (see figures 10 18) has been calculated under the following sky conditions: CIE clear sky on 14 th March in Berlin office with south facade direct normal irradiance: 430 W/m² diffuse horizontal irradiance: 193 W/m² The luminance pictures show that for the glare protection at least for the 3 louver canopy system and for the synchronous tracking system an additional internal glare protecting shading device is necessary in order to prevent direct sun light penetration into the office particularly directly onto the VDT screen. Even for the counter tracking louver the usage of such sun shading screen is recommended because of the occurrence of disturbing narrow sun patches (see figure 16 18). Figure 10 3 louvre canopy system - office view Figure 11 3 louvre canopy system visual display terminal view Figure 12 3 louvre canopy system - luminance distribution in visual display terminal view - 1674 -

Figure 13 synchronous tracking louvre office view Figure 16 counter tracking louvre office view Figure 14 synchronous tracking louvre visual display terminal view Figure 17 counter tracking louvre visual display terminal view Figure 15 synchronous tracking louvre luminance distribution in visual display view Figure 18 counter tracking louvre luminance distribution in visual display terminal view - 1675 -

CONCLUSION The aim of this work was to evaluate three different external shading device systems in terms of their influence on the energy required for heating, cooling and artificial lighting for the typical office rooms which are equipped with these systems. All systems are basically rotating PV louvers which are following the sun position (louvers are perpendicular to the direct solar radiation in the vertical projection). The 3 louvre canopy system is intended for facades with windows and parapets The Synchronous Tracking Louvre is for rooms with high facades. All louvers are moving parallel. The louvers are only partly covered with PV cells (self shading effect) The Counter Tracking Louvre is also for rooms with high facades. The PV louvers move parallel (red lines), the counter louvers (light diffusing material with low transmittance) move in the opposite direction. The PV louvers are completely covered with PV cells. On the solar test field of ZSW the influence of the Counter Tracking Louvre on the internal temperature and illuminances of a container box was measured in order to check - calibrate the simulation models for daylighting and thermal performance. For the typical office rooms the energy demand for cooling, heating and lighting was calculated by using a dynamic thermal simulation software. Typical internal heat sources also where considered (persons, computers and artificial light). Hourly values for the shading coefficients were pre-calculated with the RADIANCE computer software. Comparisons were made for two different climates (middle Europe Berlin, southern Europe Madrid) and two office orientations (west, south). The results can be summarized as follows: shading factors 3 louvre canopy system : 0,49 0,57 depending on orientation an climate STL: 0,29 0,38 depending on orientation an climate CTL: 0,16 0,23 depending on orientation an climate Energy demand Here only the qualitative facts could be determined in the terms of the total energy demand. This total energy demand was expressed as thermal energy, electric energy was converted to thermal energy by using a conversion factor. For a middle European climate an office with a 3 louver canopy system has the lowest total energy demand because the shading is still very efficient for reduction of the cooling load but allows some solar gain in the heating season. A STL equipped office needs about 10 % more a CTL equipped office about 40 % more overall energy. For a south European climate the STL equipped office has the lowest theoretical total energy demand, especially for south orientation the 3 louvre canopy system have about 40 % and the CLT about 50 % higher demands (for west orientation these figures are 10 % respectively 25 %). If we only look for electric energy (cooling + artificial lighting) the STL equipped office has the lowest energy demand for all climates and orientations. All the theoretical differences in energy demand are still in a range that the influence of user behaviour or/and not efficient controls for lighting, heating and cooling could result in higher differences. ACKNOWLEDGEMENT The work on this paper has been supported by scientific - research grant VEGA 1/0647/09. REFERENCES Clarke, J. A. 2001. Energy simulation in building design. Architectural Press, 2nd edition. Ward, G. J., The Radiance Lighting Simulation System, Global Illumination, Siggraph '92 Course Notes, July 1992. Janak, M. Coupling building energy and lighting simulation. Fifth International IBPSA Conference, September 8 10, 1997, Prague, pp. 313 319. Janak, M. and MacDonalld, I. Current state-of-the-art of integrated thermal and lighting simulation and future issues. Sixth International IBPSA Conference, September 13. 15. 1999, Kyoto, Japan, pp. Janak, M. 2003. Whole building energy simulation with complex external shading devices. Eighth - 1676 -

International IBPSA Conference, August 11. - 14., 2003, Eindhoven, Netherlands, pp. 571 576. Perez, R. at al. 1993. All-weather model for sky luminance distribution preliminary configuration and validation. Solar Energy 50(3), pp. 235 2-1677 -