Agilent 7890 GC Instrument Control Software Version 2.6

Similar documents
Agilent 7890 GC Instrument Control Software Version 2.5

Agilent 7890 GC Instrument Control Software Version 2.01

Waters Headspace Control Option, Version 3.0

Waters Fraction Collector III with Empower Instrument Control Software Version 1.00

Agilent Instrument Control Framework (ICF) Update A Driver Update 1 (DU1) Hot Fix 2 (HF2)

SCN 848 Release Notes

Empower 3 Feature Release 3 Hotfix 1 Release Notes

Waters Empower 2 Service Pack G

Waters Empower Software A1100 System Configuration Instructions for Ethernet Control

For additional information, see these documents on the Breeze 2 software DVD:

Waters ACQUITY QDa Instrument Component Software version 1.54

Agilent ICF Support v3.0

Waters Driver Pack 2016 Release 1

A. About this Manual

Waters 2707 Autosampler ICS v1.20 Installer

Empower 3 Installation, Configuration, and Upgrade Guide /Revision A Copyright Waters Corporation All rights reserved

MassLynx 4.2 SCN 989 Release Notes

ACQUITY UPLC Systems June 2011 Driver Pack and Firmware Updates

Empower 2 Feature Release 5 Upgrade Guide

Alliance e2695 Separations Module Firmware Version 3.04

Waters Empower Software Build 1154 Toolkit Service Pack Release Notes

The instrument drivers and firmware in Driver Pack 4 support these ACQUITY UPLC systems: ACQUITY UPLC Systems with 2D Technology

Breeze 2 Installation and Configuration Guide

Agilent OpenLAB CDS Waters Alliance HPLC Instrument Control Add-On. Installation, Upgrade and Migration Guide

Waters Empower 3 Feature Release 1

Waters Empower 3 Feature Release 1

MassLynx 4.1 SCN 804. Release Notes. SQ Detector 2

Waters Driver Pack 2018 Release 1

Empower 3 FR3 System Administrator's Guide / Revision A Copyright Waters Corporation All rights reserved

ACQUITY UPLC Local Console Controller Instructions

Empower Software and Security Software Interactions

M8240BA Shimadzu LC Control Driver 1.51 for OpenLAB CDS

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes. System Information. Agilent Technologies

Installation and Configuration User's Guide

New features and Workflow Enhancements Empower 3 Software

Agilent Instrument Control Framework A for Agilent LC/CE and GC Instruments in Non-Agilent Chromatography Data Systems Release Notes

Agilent OpenLAB CDS. Version 2.2. Release Notes. OpenLAB CDS Release Notes 1

Agilent 7890GC. Firmware Bulletin. Revision B and A External use only

Windows 7 Professional 64 bit Installation and Configuration for MassLynx or Empower Controlled Ethernet Instrument Communication

Release Notes for Avaya Proactive Contact Supervisor

Sharpdesk V3.3. Push Installation Guide for system administrator Version

Installing VisionPro. VisionPro PC Requirements. Minimum PC Requirements. Microsoft Visual Studio. Operating Systems

KYOCERA Net Admin Installation Guide

Release Notes for Avaya Proactive Contact 5.0 Supervisor. Release Notes for Avaya Proactive Contact 5.0 Supervisor

Installing and Using VeritiLink Software Quick Reference Card

ChromQuest 4.2 Chromatography Data System

Procedure to set up an HPIB 82350B card on an M57. M58 or C20x PC. Table 1: Parts required. Part Number Description Qty

Agilent MassHunter Easy Access Software

Subject: Installation Instructions from 2.0 or lower Released: 04/16/2015

IDEA 3.4 Upgrade Instructions

Thermal Transient Test

Dell Storage Center OS Version 7 Software Update Guide

CRA Wiz and Fair Lending Wiz. Installation Guide V6.9

unisys Agile Business Suite How to Install Visual Studio 2013 for AB Suite 5.0 Applies to: Developer 5.0

Data Acquisition with CP-2002/2003 Micro-GC Control

Perceptive Intelligent Capture

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

Relativity Data Server

ZENworks 2017 Update 2 ZENworks Agent Reference. February 2018

Warning 101 Invalid heater power for front detector, inlet, and aux 1 Warning 102 Invalid heater power for back detector, inlet, and aux 2

Micro Focus The Lawn Old Bath Road Newbury, Berkshire RG14 1QN UK

Relativity for Windows Workstations

Agilent G2727AA LC/MS Data Browser Quick Start

Installation Information Version (CLM) English. Leica Client License Manager (CLM)

Product Release Notes for Avaya Proactive Contact Supervisor

Agilent GC Drivers A

EPiServer Installation Instructions

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

Upgrade to and Installation of SQL Server 2008 (R2) in an SAP Environment

VisionPro 7.0. Quick Reference COGNEX. Distribué par : Contact : Tél : Fax :

Keithley Instruments ExceLINX-3A ExceLINX software for the Model 2000 Release Note for Version C02 3/26/2015

Data Acquisition with 3400/3600 GC Control

REVISIONS * The manual number is given on the bottom left of the back cover.

UNIFI UNIFI Installation and Configuration Guide / Revision A Copyright Waters Corporation 2013 All rights reserved

Symantec pcanywhere 12.5 SP4 Release Notes

Agilent GC/MSD Instructions

8100 Mobile Device System. Radio Access: Call Reliability Product Update

ImageAssist Static. User's Guide for Single Platform

HITACHI LACHROM ELITE

Agilent 1290 Infinity II Evaporating Light Scattering Detector (ELSD) in Empower Environment

EZChrom Elite Compact. What s New in EZChrom Elite Compact Service Pack 2

Customers should provide all necessary operating supplies upon request of the engineer.

XLmanage Version 2.4. Installation Guide. ClearCube Technology, Inc.

Release Notes for Avaya Proactive Contact 5.0 Agent. Release Notes for Avaya Proactive Contact 5.0 Agent

Fibre Channel Adapter STOR Miniport Driver for Windows. Table of Contents

CTC Sampler Implementation in the GC/MSD ChemStation. Technical Overview. Introduction

Copyright Autodesk, Inc.

WEBSEWSS SINGLE SERVER INSTALLATION INSTRUCTIONS

Ascent 6.06 Release Script for Hummingbird DM Release Notes

8100 Mobile Device Test System. Radio Access: Data Throughput Product Update

Receiver (Updater) for Windows 2.0

Records Manager Installation Guide

MassLynx TM 4.1 SCN 916 Release Notes

Subject: DataLine Version /27/2012 Released: 11/27/2012

Oracle Workflow Builder and Oracle XML Gateway Message Designer Hardware and Software Requirements

The minimum version of Microsoft's Internet Explorer is version If you need to upgrade, install version 6.0, service pack 1.

EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows. Installation Guide. 01/29/2016 3rd Edition

Inmagic Content Server Workgroup Version 9.00 Installation Notes for New and Upgrade Installations

Varian Modular HPLC System Galaxie Driver Installation and Configuration Instructions

These are the minimum supported OS and pre-requisites for Mediaocean Spectra-PF version 18.1 and above.

Transcription:

R E L E A S E N O T E S Agilent 7890 GC Instrument Control Software Version 2.6 Version 2.6 of the instrument control software (ICS) for the Agilent 7890 GC addresses several issues, provides support for the G3520 Transfer Line Interface (TLI), and corrects a problem involving operation of the inlet under cryogenic conditions. These release notes explain how to install Agilent 7890 GC ICS v2.6 for Empower 2, Empower 3, and MassLynx software applications. This v2.6 release of the ICS supports both the Agilent 7890A and 7890B GC. Tested firmware and software... 2 Installing the Agilent 7890 GC ICS... 4 Validation Information... 5 Verifying the Installation... 6 Uninstalling the ICS for the Agilent 7890 module... 6 Issues fixed in this release... 6 Known issues in this release... 7 Installation Files... 9 Test Configurations... 11 Personal workstation test configuration... 11 Database Server test configuration... 12 Client test configurations... 12 LAC/E 32 Acquisition Server test configuration... 12 Waters and "THE SCIENCE OF WHAT'S POSSIBLE." are registered trademarks and LAC/E is a trademark of Waters Corporation. Agilent is a registered trademark of Agilent Technologies, Inc. Citrix is a registered trademark of Citrix Systems, Inc. Microsoft and Windows are registered trademarks of Microsoft Corporation. All other trademarks are the sole property of their respective owners. Copyright 2015 Waters Corporation *716004276* *Rev.A* Page 1 of 12

Tested firmware and software The versions of 7890 GC firmware tested with this release are A.01.15 (7890A minimum) and B.02.02 (7890B minimum). Later versions of firmware are expected to work; refer to the Agilent firmware notes for qualification information. This version of the ICS supports Empower 2 and Empower 3 software in English, Japanese, (Simplified) Chinese, and Korean. The following table lists the software configurations, feature releases, service packs, and operating systems that were tested with the 7890 GC ICS v2.6. Application Software Empower Personal Minimum Feature Release/ Service Pack Operating system Empower 2 FR5 SPH HF1 Windows XP SP 3 Empower 2 FR5 Windows XP SP 3 Empower 3 FR1 Windows 7 Professional 64 bit Empower 3 FR2 Windows 7 Professional 64 bit Empower 3 SR1 Windows 7 Professional 64 bit Empower 3 SR2 Windows 7 Professional 64 bit Empower Workgroup and Enterprise Empower 2 Empower 3 FR5 SPH HF1 SR 2 Client: Windows XP SP 3 Server: Windows 2003 server R2 SP2 Client: Windows 7 Professional SP1 Server: Windows Server 2008 R2 Standard SP1 Empower 3 FR 2 Client: Windows XP SP 3 Empower 3 SR 1 Server: Windows Server 2008 R2 Standard SP1 LAC/E 32 : Windows 7 Professional SP1 Server: Win 2008 R2 SP1 Enterprise Empower 2 FR5 Client: Windows XP SP3 Server: Windows Server 2003, SP2 (32-bit) Empower 3 FR1 Client: Windows 7 SP1 Server: Windows Server 2008 R2 SP1 Enterprise (64-bit) Page 2 of 12

Application Software Citrix Application Server Minimum Feature Release/ Service Pack Operating system Empower 2 FR5 SPH HF1 Windows Server 2003, SP2 (32-bit) Empower 3 SR2 Windows Server 2008 R2 SP 1 Enterprise 64 bit MassLynx 4.1 SCN 905 for Xevo TQ-S and Xevo TQ MS SCN 723 for Xevo QTof SCN 781 for Synapt G2 ETD SCN 802 for Xevo G2 QTof SCN 805 for Quattro Micro GC SCN 815 for Autospec SCN 816 for GCT Premier SCN 843 for Xevo TQ-S/XEVO TQ MS SCN 851 for Synapt G2-S APGC Windows 7 Professional SP1 Windows XP SP3 Windows 7 SP1 Windows XP SP3 Windows 7 SP1 Windows 7 SP1 Windows 7 SP1 Windows XP SP3 Windows 7 SP1 Requirements: For Windows Server 2003, Windows Server 2008, Windows XP, and Windows 7 systems, Microsoft.NET Framework 3.5 is required and will be installed automatically if needed. For Windows Server 2003, Windows Server 2008, Windows XP, and Windows 7 systems, Microsoft Visual C++ 2008 Redistributable is required and will be installed automatically if needed. The minimum requirements for Empower 2 and Empower 3 Software are FR5 and SR1, respectively. The computer configurations and operating systems the Waters ICS supports for the 7890 GC are listed at the end of this document. For details on supported service packs and incremental operating-system and hotfix support, see the Empower 2 and Empower 3 installation and configuration guides. Also consult the relevant software release notes and the Waters Web site (www.waters.com). Page 3 of 12

Installing the Agilent 7890 GC ICS Recommendation: Back up all Empower projects, library information, and databases before installing this software. The Agilent 7890 GC ICS v2.6 consists of these components: Deployment Manager To install or uninstall the 7890 GC ICS driver. Driver Needed for Empower software to communicate with the module. User interface Includes the instrument method editor and control panels in Empower Quick Start and Run Samples utility. Online Help for the 7890 GC Access online Help when working with an Agilent instrument method by clicking the question mark while using the instrument method editor. Note: No Oracle or system files are affected by installing version 2.6 of the Agilent 7890 GC ICS. The only files installed when the ICS is installed are those files that are required by the ICS. Requirements: Install Empower software or MassLynx software before installing the 7890 GC driver. Install the 7890 GC v2.6 ICS using only the Waters Deployment Manager which is packaged with the Agilent 7890 GC ICS v2.6 media. To use the ICS software on an Empower Enterprise (client/server) system, you must install it on every computer, LAC/E 32 module, client, and Citrix application server that interacts with the 7890 GC, its methods, or results. For consistency, install the same version of the ICS on all clients, LAC/E 32 modules, and Citrix application servers. You need not install the ICS software on the database server unless the server hosts the Empower client software and interacts with the GC instrument, its methods, or its results. Note: Push installation is now supported using PsExec for the 7890 GC ICS. General installation instructions using ICS media (not for a Citrix application server): 1. Power-off the 7890 GC, and reboot the computer. 2. Log in to the computer using an account with local administrator privilege. 3. Insert the Agilent 7890 GC ICS media in the media drive. 4. Browse to the root of the media, and double-click the setup.exe file to begin the installation using Waters Deployment Manager. 5. Follow all prompts, to finish the installation. 6. Reboot the computer. 7. Power-on the 7890 GC. Note: If previous versions of the 7890 GC ICS (such as 7890 v2.0, 7890 v2.01, or 7890 v2.5) are installed you can upgrade to 7890 GC ICS version 2.6 by following the instructions above. Page 4 of 12

General installation instructions using a downloaded executable file: 1. Power-off the 7890 GC, and reboot the computer. 2. Log in to the computer using an account with local administrator privileges. 3. Browse to the A7890_GC_v26.exe file (downloaded from Waters.com) on your local hard drive, and then double-click the file. 4. Click Unzip, to extract the installation files, browse to the extracted file location, and then double-click the setup.exe file, to begin the installation using Waters Deployment Manager. 5. Follow all prompts to finish the installation. 6. Reboot the computer. 7. Power-on the 7890 GC. Note: If previous versions of the 7890 GC ICS (such as 7890 v2.0, 7890 v2.01, or 7890 v2.5) are installed, you can upgrade to 7890 GC ICS version 2.6 by following the instructions above. To install the Agilent 7890 GC ICS on an Empower Citrix server: 1. Power-off the 7890 GC, and reboot the computer. 2. Log in to the computer using an account with local administrator privilege. 3. Insert the 7890 GC ICS media into the media drive. 4. Put the Citrix server in Install mode by opening a command prompt and typing Change user /install. Result: An advisory appears: User session is ready to install applications. 5. Browse to the root of the media, and double-click the setup.exe file to begin the installation using Waters Deployment Manager. 6. Put the Citrix server in Execute mode by opening a command prompt and typing Change user /execute. Result: An advisory appears: User session is ready to execute applications. Validation Information After you install or uninstall the Agilent 7890 GC ICS on a qualified system, Waters recommends determining your requalification needs in accordance with your laboratory s standard operating procedures. If this is an initial installation in a GxP-regulated environment, perform a full qualification of Empower software. Waters recommends that you run the Verify Files utility or the ConnectionsAQT for Empower IQ and review the resulting file for an entry that states No installation changes were detected. This ensures that the installation did not alter or otherwise affect existing files. Note: The date displayed when the Verify Files (IQ) runs always reflects the previous installation. See the Empower.log file for the complete history. Page 5 of 12

Verifying the Installation To verify the installation, select Start > All Programs > Empower > Empower Installation Log. Search for lines similar to this: ***************************************************************** Installed Waters 7890 Software 2.6.14.0819 on 4-19-2015 21:10:11 ***************************************************************** The installation of any option or service pack is documented in the checksum.txt file on the Empower computer. This file indicates the installation of any option or (options) or service pack. The file also verifies the integrity of disk files by comparing their current cyclic redundancy check (CRC) and sizes with their original values. Those values were recorded during the installation of the base software and, if applicable, any installed option or service pack. This file is created when you run the Verify Files utility by selecting Start > Programs > Empower > Verify Files. To display the checksum.txt file, navigate to the \Empower\Script directory, and then double-click the checksum.txt file. Uninstalling the ICS for the Agilent 7890 module To ensure successful file verification following the removal of the ICS, you must reboot the computer before you uninstall the ICS. To remove any version of the Agilent 7890 GC ICS from your system: 1. Reboot the computer. 2. Log in to the computer using an account with local administrator privilege. 3. Open the Control Panel and double-click Add/Remove Programs. 4. At the Add/Remove Programs dialog box, click the Change or Remove Programs icon. 5. Click the version of Agilent 7890 GC ICS that is on your system, and then click the Change/Remove button. 6. Follow the prompts to remove the control software from your system. The registry and new CRC checksums are updated for the Empower installation. No Oracle or system files are affected. Issues fixed in this release Note: Waters uses product change system (PCS) numbers to track the status of issues. PCS Number Description 49110 Control is added for the G3520 Transfer Line Interface, used with Headspace analysis. Temperature is set using temperature zones Aux 1 or Aux 2. 49304 7890 GC ICS version 2.5 placed files, incorrectly, in the root directory of the computer. Files are placed in their correct location in version 2.6. Page 6 of 12

PCS Number Description 49525 Valve events for the 7890 GC were incorrectly recorded as 0 and 1 instead of On/Off. They are correctly recorded in version 2.6. 50393 Removing the A7890 v2.01 or v2.5 driver produces extra entries in the dir.cks file, causing the Empower Verify Files utility to report a failure when any component included in the 7890 v2.5 checksum file is modified to a different version. This behavior is corrected in version 2.6. Instead of uninstalling v2.01 or 2.5, upgrade them to v2.6. 51768 Negative temperature settings are now available for components that allow negative temperature settings when cryo cooling is properly configured and enabled. 51790 After installing A7890 v2.5, if any component included in the created checksum was updated, the Verify Files utility reported it as changed. Version 2.6 corrects this behavior. 52008 The Sample Offset setting for the 7683 autosampler is now functional. Known issues in this release Note: Waters uses Product Change System (PCS) numbers to track the status of issues. PCS Number Description 44323 The signal zero event of the analog signal does not function as expected. 47710 Using the Inject Ahead feature when analyzing a sample whose run time exceeds 10 minutes can cause an error that results in instrument failure. The Inject Ahead feature, which is not compatible with dual-tower injection capability in Empower software, is discontinued. 47858 If you fail to enter the serial number in the Empower node properties on the DHCP tab, the instrument scans as no instead of yes. To prevent this problem, complete all of the fields in the table during installation, so Yes appears when you scan the instrument. 48391 If you create a back injector instrument method and specify dual tower mode in Empower software, you must also enable the second data channel in the instrument method. 48600 Even if the dual-tower check box is enabled, the dual-tower option might not appear, as expected, in the tool bar. Disabling and then re-enabling dual-tower mode (by clicking View > Toolbars > Dual Tower Mode, thus deselecting and reselecting it) causes the option to appear in the tool bar. 48682 The online Help description of the tray chiller is inaccurate. The tray chiller interface does not control the heating or cooling of the vial tray. It merely determines whether a specified temperature is reached or is out of range. 48685 If you set up a run and then disconnect the Ethernet cable while the system is operating, error message 39 states Client is not GC owner. You must then reboot the 7890 GC and the Empower node, to re-establish the connection. 48724 When you uninstall the 7890 GC ICS from the MassLynx/Empower computer, and the ICS is the last one (or only one) to be uninstalled from the target computer, error message 1905 appears. The appearance of this message does not affect MassLynx/Empower functionality. 48769 For data acquired before Empower 3 software was installed, use the Comprehensive Status report group to report the post run information stored with Page 7 of 12

PCS Number 48773 48774 Description the channel. For data acquired by Empower 3 software, use the Post Run report group to report the post run information stored with the injection. An error message appears if you try to report pre-empower 3 data using the Post Run report group, or if you try to report Empower 3 (minimum) data using the Comprehensive Status report group. Empower Software cannot support both dual-tower GC injections and the "Inject Ahead" capability of the Agilent 7890 GC. With the support of dual-tower injection capability in Empower 2 SP H Hotfix 1 and Empower 3 FR1, support for the "Inject Ahead" capability of the 7890 GC autosampler has been discontinued. 52667 In the Aux zone, when a temperature is specified and then the method is saved, the unit changes from degrees Celsius to psi. On changing the page and returning to the Auxiliary page, the unit reverts to degrees Celsius. 52669 Valve box and Unknown can be controlled simultaneously by both Aux zones. The heating zones, like valve box etc., must be controlled by either Aux thermal 1 or Aux thermal 2. 53069 In the instrument method, clicking outside an edit box that contains an out-ofrange value prompts the error message Out of Range.. This message is prompted only once, and you cannot save the method nor make changes in it until you correct the out-of-range entry. 53154 When reporting an Empower 2 or Empower 3 instrument method for the Agilent 7890 GC, the fixed format of instrument method reporting can show "impossible" conditions, such as reporting a split-flow value for an inlet that does not support Split mode - the Purged Packed inlet, for example. This behavior does not affect the operation of the GC. 53369 When using Push installation to install the 7890 GC ICS in an Empower 2 configuration, Empower 3 incorrectly appears as the name of the installation log file in. For example, the file MACHINE-7890E2_2014-05-27_04-22-16-222- PM_Empower3_ICS should be named MACHINE-7890E2_2014-05-27_04-22-16-222-PM_Empower2_ICS. 53403 The Deployment Manager provided with the 7890 GC ICS v2.6 can be used only to install or upgrade from older versions of the 7890 GC ICS to version 2.6. Do not use the 7890 GC ICS v2.6 version of the Deployment Manager to install, upgrade, or remove any other ICS. 53436 When using Add/Remove Programs to view the size of a program, the size of the 7890 v2.6 ICS is incorrectly reported. The 7890 v2.6 installer does not calculate program size. The discrepancy is a Windows installer issue. 53467 In the Chinese, Japanese, and Korean method editor for the 7890 GC, when a few error messages are displayed, the title of the message boxes appear in English. 53549 On occasion, when trying to connect the 7890 GC to a new computer, the following error message can appear in the Empower message center: "67: The unit is not in a valid state to execute an operation." On receiving this message, restart both the PC and the instrument. If the message continues to appear, contact Waters support. Page 8 of 12

Installation Files The following files are installed in the Empower\Instruments directory. DiscoverInstruments.dll Waters DHCP Server Configuration WDHCPServerSvc WDHCPServerSvcResCHI.dll WDHCPServerSvcResENU.dll WDHCPServerSvcResJPN.dll WDHCPServerSvcResKOR.dll The following files are installed in the Empower\Instruments\Bin directory. A7890Common.dll A7890EditMgr.ocx A7890Instr.dll A7890Xml.dll InstrIDL.dll WS7890.dll WS7890.tlb WS7890Comms.dll WS7890Comms.tlb cmn.cks The following files are installed in the Empower\Instruments\Bin\En directory. A7890ResENU.dll The following files are installed in the Empower\Instruments\Bin\ja directory. A7890ResJPN.dll The following files are installed in the Empower\Instruments\Bin\ko directory. A7890ResKOR.dll The following files are installed in the Empower\Instruments\Bin\zh-CHS directory. A7890ResCHI.dll The following files are installed in the Empower\Instruments\HTML\A7890 directory. A7890-Config-Current.xml A7890-Config-R100.xsd A7890-Config-r100.xsl A7890-Method-Default.xml A7890-Method-R100.xsd A7890-PrintMethod-r100.xsl Page 9 of 12

A7890-PrintMethodNoALS-r100.xsl A7890-Report-Current.xml A7890-Report-r100.xsl A7890-Report-r100.xsd A7890-ResourceCHI-r100.xml A7890-ResourceENU-r100.xml A7890-ResourceJPN-r100.xml A7890-ResourceKOR-r100.xml A7890-StatusDetail-Current.xml A7890-StatusDetail-R100.xsd A7890.js A7890Button.bmp A7890ControlPanel.htm DefaultPrint-r102.xsl FieldDefToHTML.xsl FieldDefToText.xsl FieldDefToTextNoTabs.xsl ICSResources-r100.xsd Locale.xsl overlib_mini.js Syringe.JPG The following files are installed in the Empower\Instruments\Help\en directory. A7890.chm The following files are installed in the Empower\Instruments\Help\ja directory. A7890.chm The following files are installed in the Empower\Instruments\Help\ko directory. A7890.chm The following files are installed in the Empower\Instruments\Help\zh-CHS directory. A7890.chm The following file is installed in the Empower\Instruments\HTML\A7890\LVI directory. Useful GC calculations.xlsx This file contains calculations for Large Volume Injections for the Multimode inlet. It is included for convenience. Page 10 of 12

Test Configurations The following test configurations were used during the development and evaluation of A7890 ICS v2.6. Personal workstation test configuration Operating system and service pack: Microsoft Windows XP, SP3, English Microsoft Windows Hotfixes: KB898458 KB923723 KB2378111 KB2834903 KB952069 KB954155 KB973540 KB975558 KB978695 KB917734 KB936782 KB925398 KB923689 KB941569 KB2183461 KB2510531 KB2598845 KB2862772 KB2909210 KB2909921 KB2936068 KB2936068 KB2964358 KB2964358 KB938127 KB942615 KB944533 KB969897 KB982381 KB2564958 KB971513 KB936929 KB2079403 KB2115168 KB2160329 KB2229593 KB2286198 KB2296011 KB2345886 KB2347290 KB2387149 KB2393802 KB2419632 KB2423089 KB2443105 KB2467659 KB2478960 KB2478971 KB2479943 KB2481109 KB2483185 KB2485663 KB2506212 KB2507938 KB2508429 KB2509553 KB2510581 KB2535512 KB2536276-v2 KB2544893-v2 KB2566454 KB2570947 KB2584146 KB2585542 KB2592799 KB2598479 KB2603381 KB2619339 KB2620712 KB2631813 KB2653956 KB2655992 KB2659262 KB2661637 KB2676562 KB2686509 KB2691442 KB2698365 KB2705219 KB2712808 KB2719985 KB2723135-v2 KB2727528 KB2749655 KB2757638 KB2770660 KB2780091 KB2802968 KB2807986 KB2813345 KB2820917 KB2834886 KB2847311 KB2850869 KB2859537 KB2862152 KB2862330 KB2862335 KB2864063 KB2868038 KB2868626 KB2876217 KB2876331 KB2892075 KB2893294 KB2898715 KB2900986 KB2904266 KB2909212 KB2914368 KB2916036 KB2922229 KB2929961 KB2930275 KB2934207 KB923561 KB938464-v2 KB946648 KB950760 KB950762 KB950974 KB951066 KB951376-v2 KB951748 KB951978 KB952004 KB952287 KB952954 KB954459 KB954550-v5 KB954600 KB955069 KB955759 KB955839 KB956572 KB956744 KB956802 KB956803 KB956844 KB957097 KB958644 KB958687 KB958869 KB959426 KB960225 KB960803 KB960859 KB961118 KB961373 KB961501 KB967715 KB968389 KB968537 KB969059 KB969898 KB970238 KB970430 KB971029 KB971657 KB971961 KB972270 KB973507 KB973815 KB973869 KB973904 KB974112 KB974318 KB974392 KB974571 KB975025 KB975467 KB975560 KB975562 KB975713 KB977816 KB977914 KB978037 KB978338 KB978542 KB978601 KB978706 KB979309 KB979482 KB979687 KB980195 KB980218 KB980232 KB980436 KB981349 KB981793 KB981852 KB981997 KB982132 KB982214 KB982665 Operating system and service pack: Windows 7 Professional, SP1 Microsoft Windows Hotfixes: KB2849697 KB2849696 KB2841134 KB2670838 KB2830477 KB2592687 KB971033 KB2305420 KB2393802 KB2479943 KB2484033 KB2488113 KB2491683 KB2506014 KB2506212 KB2506928 KB2509553 KB2511250 KB2511455 KB2515325 KB2522422 KB2532531 KB2533552 KB2536275 KB2536276 KB2541014 KB2544893 KB2545698 KB2547666 KB2552343 KB2560656 KB2563227 KB2564958 KB2570947 KB2574819 KB2579686 KB2584146 KB2585542 KB2603229 KB2604115 KB2618451 KB2619339 KB2620704 KB2621440 KB2631813 KB2640148 KB2644615 KB2645640 KB2647753 KB2653956 KB2654428 KB2655992 KB2656356 KB2658846 KB2659262 KB2660075 KB2660649 KB2661254 KB2667402 KB2676562 KB2685811 KB2685813 KB2685939 KB2690533 KB2691442 KB2698365 KB2699779 KB2705219 KB2706045 KB2709630 KB2709981 KB2712808 KB2718704 KB2719857 KB2726535 KB2727528 KB2729094 KB2729452 KB2732059 KB2732487 KB2732500 KB2736422 KB2741355 KB2742599 KB2743555 KB2749655 KB2750841 KB2753842 KB2756921 KB2757638 KB2758857 KB2761217 KB2762895 KB2763523 KB2769369 KB2770660 KB2773072 KB2779562 KB2785220 KB2786081 KB2786400 KB2789645 KB2790113 KB2790655 KB2791765 KB2798162 KB2799926 KB2800095 KB2803821 KB2807986 KB2808679 KB2808735 KB2813170 KB2813347 KB2813430 KB2813956 KB2817183 KB2820331 KB2832414 KB2833946 KB2834140 KB2834886 KB2835364 KB2836502 KB2836942 KB2836943 KB2839894 KB2840149 KB2840631 KB2843630 KB2844286 KB2845187 KB2846960 KB2847077 KB2847311 KB2847927 KB2849470 KB2852386 KB2853952 KB2855844 KB2857650 KB2861191 KB2861698 KB2861855 Page 11 of 12

KB2862152 KB2862330 KB2862335 KB2862966 KB2862973 KB2863240 KB2864058 KB2864202 KB2868038 KB2868116 KB2868623 KB2868626 KB2868725 KB2872339 KB2875783 KB2876284 KB2876331 KB2882822 KB2884256 KB2887069 KB2888049 KB2891804 KB2892074 KB2893294 KB2893519 KB2898857 KB2900986 KB2901112 KB2904266 KB2908783 KB2909210 KB2911501 KB2912390 KB2913152 KB2913431 KB2913602 KB2916036 KB2918077 KB2919469 KB2922229 KB2923545 KB2925418 KB2928562 KB2929437 KB2929733 KB2929755 KB2929961 KB2930275 KB2936068 KB958488 KB976902 KB976932 KB982018 Database Server test configuration Operating system and service pack: Windows Server 2008 R2 Enterprise, SP1 Microsoft Windows Hotfixes: KB2305420 KB2393802 KB2425227 KB2506014 KB2506212 KB2509553 KB2511455 KB2536275 KB2536276 KB2544893 KB2552343 KB2560656 KB2564958 KB2570947 KB2584146 KB2585542 KB2618451 KB2620704 KB2621440 KB2631813 KB2643719 KB2644615 KB2645640 KB2653956 KB2654428 KB2655992 KB2658846 KB2659262 KB2661254 KB2667402 KB2676562 KB2685939 KB2690533 KB2691442 KB2698365 KB2705219 KB2706045 KB2712808 KB2718704 KB2743555 KB2749655 KB2753842 KB2757638 KB2758857 KB2765809 KB2769369 KB2770660 KB2785220 KB2790113 KB2790655 KB2807986 KB2808735 KB2813170 KB2813347 KB2817183 KB2840149 KB958488 KB976902 KB976932 Client test configurations Operating system and service pack: Windows 7 Professional SP1 64 Bit Microsoft Windows Hotfixes: KB2479943 KB2491683 KB2506014 KB2506212 KB2509553 KB2511455 KB2536275 KB2536276 KB2544893 KB2552343 KB2560656 KB2564958 KB2570947 KB2579686 KB2584146 KB2585542 KB2604115 KB2619339 KB2620704 KB2621440 KB2631813 KB2653956 KB2654428 KB2655992 KB2656356 KB2667402 KB2676562 KB2685939 KB2690533 KB2698365 KB2705219 KB2706045 KB2712808 KB2718704 KB2727528 KB2729452 KB2736422 KB2742599 KB2743555 KB2756921 KB2758857 KB2770660 KB2785220 KB2786081 KB2789645 KB2798162 KB2803821 KB2807986 KB2813347 KB2813430 KB2832414 KB2835364 KB2836942 KB2836943 KB2839894 KB2840149 KB2840631 KB2844286 KB2847311 KB2847927 KB2849470 KB2855844 KB2861191 KB2861698 KB2861855 KB2862152 KB2862330 KB2862335 KB2862966 KB2862973 KB2863240 KB2864058 KB2864202 KB2868038 KB2868116 KB2868626 KB2871997 KB2872339 KB2875783 KB2876284 KB2876331 KB2884256 KB2887069 KB2892074 KB2893294 KB2898857 KB2900986 KB2909210 KB2911501 KB2922229 KB2926765 KB2929733 KB2929961 KB2930275 KB2931356 KB2939576 KB2957189 KB2957503 KB2957509 KB2957689 KB958488 KB976902 LAC/E 32 Acquisition Server test configuration Operating system and service pack: Windows 7 Professional SP1 64 Bit Microsoft Windows Hotfixes: KB2425227 KB2479943 KB2491683 KB2503665 KB2506014 KB2506212 KB2507618 KB2509553 KB2510531 KB2511455 KB2518869 KB2533552 KB2536275 KB2536276 KB2539635 KB2544521 KB2544893 KB2552343 KB2556532 KB2560656 KB2564958 KB2567680 KB2570947 KB2572077 KB2579686 KB2588516 KB2618444 KB2618451 KB2619339 KB2620704 KB2620712 KB2633952 KB2639417 KB2641690 KB976902 Page 12 of 12