Installation Instructions

Similar documents
Four-channel Venetian blind actuator 230 V Installation Instructions

1-channel shutter actuator 6A UP Installation Instructions

KNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function

Operating Instructions

Bus coupler 3 Bus coupler 3 external sensor Order No

Product documentation

Product documentation

Product documentation

Water-protected surface-mounted push-button bus coupler Order No , , ,

KNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :

Product and Application Description

KNX/EIB Product documentation. Page 1 of 23. Order-No xx Order-No xx Order-No xx Order-No xx

Operating Instructions. DALI-Gateway

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

252F 5WG FB_1 DELTA

Push button UP 287, 4 - fold

The output variables can be force-controlled from a coordinating control system.

1 Safety instructions. 2 Device components. KNX Touch/Glass sensor comfort

Operating Instructions. Power-DALI-Potentiometer

DELTA profil wall switch, single UP 241/2 5WG AB_2

Product documentation

Product documentation

DELTA i-system wall switch single UP 221/2 5WG AB_2

Mounting and Operating Instructions

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

B.IQ push button comfort 1-4gang, Flush-mounted (Up) x, x, x, x

Electrical devices may only be mounted and connected by electrically skilled persons.

The LED display (1) turns green when the load is switched on.

1 Safety instructions. 2 Device components. 3 Function. Control unit, 1-10 V 3-gang. Order-No. : Operating instructions

Product and functional description

Structure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions

GVS K-BUS R KNX/EIB Push Button Sensor Contents 1. Summary

instabus EIB System Actuator

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 Controls:

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

584 5WG AB_1 DELTA

Product documentation

Product and Function Description

Application description. KNX Push-button module 1gang. KNX Push-button module 2gang

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

EMO valve drive. 1. Function 1. Table of Contents. 2. Installation

Tebis application software

Line Coupler, MDRC LK/S 3.1, GH Q R0001

DDC110-L1.. DDC110-L4 technolon Room Module

Technical Datasheet clima RCM-CC

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

6173 AG GJB A0138

Application description. Motion detector KNX- BCU

Product and functional description

Product and functional description

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Technische Daten: instabus EIB supply instabus line: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

Application description

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Room controller LS 990 / LS plus Stainless Steel / Aluminium

Product and function description

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

Technical Manual Room temperature controller

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Application program: description and examples

Push Button Interface UP 220D31

Colour Touch Panel 3.5

Operating instructions Evaluation system for flow sensors VS / / 2013

B.IQ push button 3gang, Flush-mounted (Up) x

Blind actuator 4-gang 230 V AC Order-No

Product and Applications Description

HOME VENTILATION WITH HEAT RECOVERY. Ventilation units M-WRG-S/Z-S M-WRG-S/Z-24 M-WRG-S/Z-EIB M-WRG-S/Z-KNX (-F, -FC)

EIB/KNX ENO Radio bus interface (32-channel)

Technical Datasheet clima RCM-FC 1. Product description

/ 2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. Room temperature controller with display 6108/18-500

Product documentation

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating and mounting instructions

MeTa for Premium, Standard and Starter versions

Supplementary operating instructions for your air curtain system Controller TMC 500

Product and functional description

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

Product and Application Description

Operating instructions. Speed monitor D / / 2014

Application description. KNX push-button 1gang. KNX push-button 2gang. KNX push-button 3gang. KNX push-button 4gang. Page 1/51

u::lux Switch RJ45 Manual u::lux Switch RJ45 Manual Tel: +43/662/ Fax: +43/662/

MTN MTN

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

An optional analog input module, Order no connected to a 6-pole system connector adds four more analog sensors to the device.

Connections, displays and operating elements. Hand 1 / / 4

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Glass sensors 35. Supplementary products 39

DuoFern Multiple Wall Controller

KNX DALI Gateway Plus - User Manual

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

Deseo KNX Manual. Deseo KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 65 v basalte

Weather station AP 257/51

Line Coupler, MDRC LK/S 2.1, GH Q R0001

EY-RU 355: Room operating unit, ecounit355

1. Function 1. System M multi-function push-button, 4- gang, with room temperature control unit. Table of Contents

Product and functional description

Use of the application program

Transcription:

Dual EIB bus coupler Order no.: 1246 651, 1246 661, 1246 671 rmation The Gira SmartSensor is a product of the Instabus KNX/EIB System and complies with KNX/EIBA directives. The functions of the device depend on the software. The SmartSensor makes use of modern electronics and electrical installation technology to communicate with other EIB devices in the house and can therefore be used flexibly and in compliance with the user s requirements for many different applications. The present instructions contain information about the essential functions and operation of the device. Danger Attention! This device contains no elements which can be serviced by the user. Installation and mounting should only be effected by an electrician specialist! Failure to observe the instructions may damage the device and cause fire or other hazards. If you have questions concerning the Gira SmartSensor or special wishes as to its functions, please contact your electrical fitter. Function LC display (1) and control knob (2) Display of messages and system states control of EIB devices with control knob / pushbutton touch sensor functions time-of-day and date display (only with time synchronization via EIB) display of actual, setpoint and outside temperature sleep mode with master function Room temperature control function Heating / cooling comfort mode standby mode night-time mode frost / heat protection dew-point mode comfort prolongation Touch sensor function (3) Each rocker key can be separately programmed for: Switching toggling dimming (single-sided or double-sided actuation of key) shutter control level transmitter recalling / storing of light-scenes status LED (4) selection of controller operating mode presence pushbutton disabling of individual or all key functions 4/06 Page 1 of 10

Configuration (to be filled-in by the electrician) Left Right Controlknob Operation LC-display Rocker 1: Rocker 2: Rocker 3: Rocker 4: Masterfunction: Password: Fitting location: LC-display Symbols indicates further lines below actual highlighted line indicates further lines above actual highlighted line standby mode comfort mode night-time mode rocker operation completely or partly disabled fan running 0...9 fan intensity level service mode active password-protected functions active alarm triggered or still active room being heated room being cooled controller disabled, e.g. dew-point alarm room temperature indication outside temperature indication 4/06 Page 2 of 10

Operation Control knob The LC-display is operated only with the control knob. The following functions are available: (1) Turning: navigation in menu structure, i.e. the bar is moved up and down. (2) Brief actuation (press): selection of a page or a function; confirmation of selected item or of a value ("Enter"). Menu structure At rest, the LC display displays a title page which can include, for instance, room temperature, time of day, date, graphics, company logo or system states. After brief actuation of the control knob (turn or press), the menus structure is displayed. The menu structure comprises a maximum of 3 levels in a tree structure. The scope and the contents depend on programming and on the respective installation. (3) Long actuation (press): return to next higher level without entering the selected value ("Esc"). (4) Very long actuation: activation of service function (see chapter "Service area") (5) Master function: If no actuations are registered over a prolonged period, the SmartSensor switches the LC-display off ("Sleep mode"). Pressing/turning of the control knob will now trigger a certain room function. Selecting a menu item A menu item is selected by moving the marker bar to this menu item and by pressing the control knob briefly. The actual position inside the menu structure can be indicated at the bottom of the LC-display (example: "1.03" menu 1, then submenu 3 selected). Functions Depending on the function activated switching, dimming, shutter control, light-scene setting, etc. the type of actuation has different effects: 4/06 Page 3 of 10

"Switching" function Brief press: Indication of the state not active.triggering of the function by brief press. Turn: Selection between "On" and "Off". Long press: Return to previous menu. "Dimming" function Turn: Adjusting the brightness level. Triggering of the function by brief press. Long press: Return to previous menu. "Shutter control" function Brief press: Display "UP" Turn: Selection between "UP" and "DOWN". Selection of function by brief press. After selection of "UP" or "DOWN", the display displays "STOP", a new brief press stop the shutter movement. Important: If programmed accordingly, the device accepts also predefined positions as values (%). "Recall light-scene" function Brief press: Recall light-scene ("Set"). Long press: Return to previous menu. "Adjust light-scene" function The SmartSensor permits modification of light-scenes on the sensor itself by excluding actuators from the scene and by changing the values of individual actuators inside the scene. The modified scene is then written back into memory by a storage instruction. Changing a value / excluding from scene Brief press: Turn: Display actual actuator value Change value by turning knob to the right. Exclude actuator by turning knob to the left to "nn". Adopt new setting by another brief press. Long press: Return to previous menu. Long: Quit setting without storing Room temperature controller By means of an integrated room temperature sensor the room temperature controller is enabled to control an existing heating / cooling system. The setpoint temperature and the operation of the heating and cooling appliances depends on the operating mode of the controller. Modes of operation Comfort mode / comfort prolongation Setpoint temperature during the presence of persons, e.g. 20 C. The comfort prolongation can be activated during night-time or frost / heat protection mode (exception: windows open) e.g. by pressing the comfort button (if programmed, or by a presence detector, etc.). The setpoint temperature of the comfort mode is then activated for a preset time e.g. 1 hour. Thereafter, the controller switches back to the original mode of operation. 4/06 Page 4 of 10

Standby mode Temperature reduction during a brief absence of persons; when the controller goes back to the comfort mode, the room temperature can be quickly brought back to the reference value set for the comfort mode. Night-time mode ("Economy") Setpoint temperature for the night or other prolonged periods during which a room is not used for energysaving purposes. Heating and cooling Depending on programming, the SmartSensor can: The operating modes "Comfort", "Standby" and "Night-time" have their own setpoint values for heating and cooling and display these values accordingly. Frost / heat protection Useful for energy saving, for instance, when windows are open. The heating is activated only to such an extent that the heating pipes do not freeze in (frost protection); installed cooling appliances are activated only to such an extent that rooms are not overheated (heat protection, e.g. to prevent health hazards for persons witch circulatory problems). Alarm list The SmartSensor can handle up to 12 different alarm messages. On reception of an alarm message, the alarm list is displayed until all alarms have been confirmed. To confirm, the individual alarms must be selected by turning the control knob and by pressing this knob. The alarm symbol is displayed until all alarms have been deactivated. Alarms are displayed in the order of priority. Non-confirmed alarms are on a higher priority level than confirmed ones. An alarm is cancelled by eliminating the cause of the alarm and after the SmartSensor has received a corresponding reset telegram via the EIB. Depending on importance, alarm messages can be displayed as flashing messages or be accompanied by warning tones. Disabling of functions The rocker keys of the SmartSensor can be disabled completely or partly. When the SmartSensor is disabled, the "Lock" symbol is displayed. Dew point / controller disable The controller function can be disabled, e.g. by the signal from a dew-point sensor. During this time, the rockers are operational and also the modes of operation can be changed. 4/06 Page 5 of 10

Password Operation of the SmartSensors via the menu structure can be protected completely or partly against unauthorized operation by means of a password. When a password-protected function is selected, the LCdisplay displays the "Hand" symbol. The password is entered by selecting the corresponding menu item (brief press). In the following screen the password is symbolized by 4 asterisks "* * * *".. After a new brief press, the first figure (0...9) can be selected by turning the control knob. A second press confirms the input; the figure is now displayed again as an asterisk ("*") and the next figure can be entered. If the entered password is wrong, the device returns to the menu.. If programmed, the password can be changed from a remote location (e.g. visualization software, control panel, etc.). The password is factory-set to "1 2 3 4". Service area If programmed, the "Service area" can be activated where additional menus and settings are offered which are not available in normal operation. When the service area is active, the device displays the "Wrench" symbol. Paging system If programmed, the SmartSensor can be used to realize a paging system for transmission of free text messages or for recalling fixed texts. Example: "janitor service tel. 222" Depending on importance, the text messages can be displayed as flashing texts or also be accompanied by signalling tones. 4/06 Page 6 of 10

Montage Fitting System information The Gira SmartSensor can only be used in conjunction with the dual EIB bus coupler. The dual EIB bus coupler serves at the same time as the controller for an e2i system and integrates this system into Instabus EIB installation. The Gira SmartSensor is a product of the Instabus EIB system and complies with EIBA directives. Detailed technical knowledge is a prerequisite to proper understanding. The functions of the device depend on the application module used and on parameter programming. Planning, installation and commissioning of the device are effected with the help of PC software. The updated product database and the technical description are available in the Internet under www.gira.de. Description The Gira SmartSensor is composed of two components: The dual EIB bus coupler ensures the connection to the EIB and the e2i system, serves as an e2i controller and supplies the connected e2i modules with power. The SmartSensor application module is plugged onto the dual bus coupler and is equipped with the following elements: LC display, control knob (turn/push), control keys and temperature sensor. The functions of the SmartSensor / dual EIB bus coupler are defined by the parameters programmed into the devices. Functions See operating instructions. Safety warnings Attention: Electrical equipment must be installed and fitted by qualified electricians only and in strict observance of the relevant accident prevention regulations. Failure to observe any of the installation instructions may result in damage to the device, in fire and in other hazards. 4/06 Page 7 of 10

Installation of the dual bus coupler Install the dual EIB bus coupler in a suitable installation box (see Technical Data) or into an ITS 30 dual profile box. Fitting position see fig. A. Fitting instructions for the ITS 30 are provided in the documentation supplied. Use a safety transformer in acc. with DIN EN 61558-2-9 (VDE 0570-2-9) or the unchoked output of a corresponding EIB power supply unit as 24 V power supply. Connect the power supply with the yellow/white terminal supplied (fig. B, (4)). Lay the lines for the external supply and the e2i bus line in compliance with the prescriptions for safety extra low voltage (SELV). Connection to the EIB must be made with the red/ black EIB bus terminal (fig. B, (5)). Important: The second pair of wires of the EIB bus line can be used for the auxiliary supply. Observe the EIB rules concerning the use of the second pair of wires. Connect the wires of the e2i bus line by means of the 4- pole terminal supplied (fig. B, (6)) as follows: Connection of 4-pole e2i bus line 1. red 2. yellow 3. white 4. black Allocation of physical address: Start the address allocation procedure in the EIB software. Depress the programming button (fig. A, (1)) until the programming LED is lit up (fig. A, (2)). Important: This must not be done on several EIB devices at the same time The programming LED goes out when the flushmounted EIB bus coupler has adopted the physical address. Installation of the SmartSensor application module: After programming of the dual EIB bus coupler, the SmartSensor (fig. C, (7)) is plugged onto the bus coupler. The electrical contact is established by means of the 10-pole interface connector (fig. C, (3)). Important information: The interface shown (fig. C, (3)) is not an EIB application interface. For this reason, no EIB application modules must be plugged into this interface. Failure to observe this warning may result in damage to the device and/or in malfunctions. 4/06 Page 8 of 10

After plugging in the device for the first time, the LEDs behind the control knob are flashing slowly. The SmartSensor and the dual bus coupler must now be adapted to one another. To do so, depress the control knob briefly. After successful adaptation, the LEDs are switched off. The device is protected against removal by a screw; see fig. D. Remove the incription label cover carefully with a screwdriver or the nail of your finger FIG. E. Software download Program the SmartSensor application module with the EIB commissioning software. Documentation Note the physical address on the SmartSensor and on the dual EIB bus coupler. Note the basic programming data in the operating instructions ( Configuration and Disabling of functions chapters) and hand the operating instructions over to the customer. Important: The LED behind the control knob and the key LED of the SmartSensor signal the states of operation, especially in the event of failures (e.g. devices interchanged in operation during renovation work). Further details in this respect can be found in the technical documentation of the device. 4/06 Page 9 of 10

Technical data EIB voltage: 24 V DC (+6 V /-4 V) SELV Ambient temperature: -5 C... +45 C External auxiliary supply: EIB power consumption: Power consumption of auxiliary supply: Max. line length of e2i bus: Max. number of e2i devices: 6 24 V AC/DC (+/- 3 V) 4 W in acc. with DIN EN 61558-2-9 (VDE 0570-2-9) or unchoked output of EIB power supply (30 V DC) max. 12 ma at 24 V max. 12 ma at 24 V 50 m Type of e2i bus line: J-Y(St)Y 2x2x0.6 or J-Y(St)Y 2x2x0.8 Connection e2i system: 4-pole terminal (grey) 24-V supply: 2-pole terminal (yellow/white) EIB: 2-pole terminal (red/black) Storage/transport temp.: -25 C... +70 C Type of protection: IP 20 Safety class: Fitting depth: III 32 mm Suitable installation boxes, e.g. flush-mounting: double unit connection box Kaiser, Art. no. 1656-02 hollow wall : double unit connection box Kaiser, Art. no. 9062-02 Kaiser, Art. no. 9062-77 (halogen-free) concrete: universal box B2, Spelsberg, Art. no. 974 002 01 plus 2 installation bridges Spelsberg, Art. no. 974 120 01 plus 4 screws Spelsberg, Art. no. 974 130 01 Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: Gira Giersiepen GmbH & Co. KG Service Center Dahlienstrasse 12 D-42477 Radevormwald The CE sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. Gira Giersiepen GmbH & Co. KG Postfach 1220 D-42461 Radevormwald Telefon: +49 / 21 95 / 602-0 Telefax: +49 / 21 95 / 602-339 Internet: www.gira.de 4/06 Page 10 of 10