Product User Guide. QuadTemp and OctTemp. QuadTemp 4-Channel Thermocouple Based Temperature Data Logger

Similar documents
Product User Guide. OctProcessV2 and QuadProcessV2. QuadProcessV2-3A 4-Channel Low Level DC Current

Product User Guide CTL2000. CTL2000 Carcass Temperature Data Logger with 8 Remote Thermocouple Channels

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

HiTemp140-FP-TSK High Temperature Data Logger with Flexible RTD Probe and Thermal Shield

User s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector

Xxxxx Xxxxxx DC Voltage Data Logger

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

High Temperature Data Logger

2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

User s Guide. OM-CP-HITEMP140X2 High Temperature Dual Probe Data Logger Series

OctTemp2000. Data Logger Manual

TITAN S8. Portable Data Acquisition Logger. Product User Guide

User s Guide. OM-CP-SMR101A-KIT Soil Moisture Data Logger

Product User Guide. RFRTDTemp2000A. RFRTDTemp2000A Precision RTD Based Temperature Data Logger

TITAN S8. Transportable Data Acquisition Device. Product Brochure EN

Data Logger Quick Start Guide

Product User Guide. RFPRHTemp2000A. RFPRHTemp2000A Wireless Pressure, Humidity & Temperature Data Logger

SensorWATCH Basic RH - Wireless Setup Users Help Guide Part Number: A Revision: 1.1.0

Datalogging RH / Temperature Pen Instruction Manual

HOBO State Data Logger (UX90-001x) Manual

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

RHTemp2000. Data Logger Manual

HOBO Temp/RH 3.5% Data Logger (UX ) Manual

Software Manual. MadgeTech 4 Data Logger Software

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

Product User Guide. RFTCTemp2000A. RFTCTemp2000A Wireless Thermocouple Temperature Data Logger. *Probe Sold Separately

HOBO Temp/RH 2.5% Data Logger (UX ) Manual

HOBO Light On/Off Data Logger (UX90-002x) Manual

HOBO State Data Logger (UX90-001x) Manual

HOBO Temp Data Logger (UX ) Manual

HOBO External Temp/RH Data Logger (UX ) Manual

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

Datalogging IAQ Meter Instruction Manual

HOBO Motor On/Off Data Logger (UX90-004x) Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

RTD Probe Sold Separately. RFRTDTemp2000A. Precision RTD Based Temperature Data Logger. Product User Guide

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

Humidity & Temperature Datalogger

4 Channel Datalogging Thermometer. Instruction Manual

RH/Temperature SD Card Datalogger. Instruction Manual

MadgeTech 4 Software User Guide:

CL600 SIMPLE LOGGER RMS CLAMP-ON MODULE E N G L I S H. User Manual

Specifications FEATURES

Element CO2 Wireless CO2, Humidity & Temperature Data Logger. Product User Guide

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

HI ma Simulator

Datalogging Conductivity/ TDS Meter. Instruction Manual

User Guide True RMS Multimeter Extech EX205T

Mini Digital Multimeter

3 Channel Datalogging Thermometer

Component identification

Visible Light SD Card Datalogger

Thermocouple Calibrator

5504 Thermocouple Analog Input Module

Mini Digital Multimeter

HI HI N HI HI

Evaluates: MAX MAX31856 Evaluation System. General Description. Features. EV System Contents. MAX31856 EV Kit Files. MAX31856 EV System Photo

To connect the AC adapter:

HI ma Simulator

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

Installing LE History Record Reader program software.

User Manual. Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging. Model with NIST-Traceable Calibration

TCM-4 Data Logger Battery Replacement Instructions

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

USB-5100 Series Multi-Channel Data Loggers

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

SMT-A3 8 Channel Wireless Data Acquisition Unit

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Mini Digital Multimeter Model MN15. User's Guide

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Anemometer SD Card Datalogger. Instruction Manual

INTERFACE & SOFTWARE GUIDE

Xxxxx Xxxxxx OM-CP-TEMP1000IS-A. Intrinsically Safe Temperature Data Logger with Stainless Steel Enclosure INSTRUCTION SHEET MQS5096/1216

TC100 Precision Thermocouple Calibrator

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

For technical support please contact

3-Axis G-Force Datalogger

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

AE21 SERIES DISPLAY CONTROL TERMINAL

User's Guide. Digital Multimeter. Model MN42

CncGcoder Models HD & HDx Manual

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Datalogging Hot Wire CFM Anemometer

S7999D SOLA Operator Interface Display

3700 SERIES USER MANUAL

ATD-5493 Wireless Battery System Tester

Simple Logger II Series

Thermo-Anemometer Data Logger Model 1227

Plus-X 300. Installation and Operation Manual

A803 INSTRUCTION MANUAL

DwyerLog Logger Interface Software

MANUAL PCE-123

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

PIECAL 520B & 521B Thermocouple Source Operating Instructions

HOBO U-Shuttle (U-DT-x) Manual

3M Temperature Logger TL20/TL25 - Software Installation Guide

Transcription:

Product User Guide QuadTemp and OctTemp *Thermocouple Plugs/Probes Sold Separately *Thermocouple Plugs/Probes Sold Separately QuadTemp 4-Channel Thermocouple Based Temperature Data Logger OctTemp 8-Channel Thermocouple Based Temperature Data Logger To view the full MadgeTech product line, visit our website at www.madgetech.com.

Product User Guide Table of Contents QuadTemp and OctTemp Data Loggers Quick Start Steps... 1 Product Overview... 2 Additional Features & Operation... 3-4 Product Maintenance... 5 Recalibration... 5 RMA Instructions... 5 General Specifications... 6-9 Support... Back Cover To view the full MadgeTech product line, visit our website at www.madgetech.com.

Quick Start Steps QuadTemp and OctTemp Product Operation 1. Insert the Software USB Stick in an open USB port. If the autorun does not appear, locate the drive on the computer and double click on Autorun.exe. Follow the instructions provided in the Wizard. Install the MadgeTech 4 Software and USB Drivers onto a Windows PC. 2. Launch the MadgeTech 4 Software. 3. The IFC200 interface comes with a USB cable. Plug one end of the cable into an available USB port on the PC and plug the opposite end of the cable into the communication port on the IFC200. The drivers will install automatically. 4. The device will appear in the Connected Devices list, highlight the desired data logger. For most applications, select Custom Start from the menu bar and choose the desired start method, reading rate and other parameters appropriate for the data logging application and click Start. ( Quick Start applies the most recent custom start options, Batch Start is used for managing multiple loggers at once, Real Time Start stores the dataset as it records while connected to the logger.) The status of the device will change to Running, Waiting to Start or Waiting to Manual Start, depending upon your start method. 5. Disconnect the data logger from the interface cable and place it in the environment to measure. Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device cannot be restarted until it has been re-armed by the computer. 6. To download data, connect the logger to the interface cable. Highlight the data logger in the Connected Devices list. Click Stop on the menu bar. Once the data logger is stopped, with the logger highlighted, click Download. You will be prompted to name your report. Downloading will offload and save all the recorded data to the PC. 1

Product User Guide Product Overview The QuadTemp is a four channel thermocouple temperature data logger with a reading rate of up to 4 Hz. It can measure and record data for up to 500,000 readings per channel. To maximize memory capacity, users can disable unused channels to add additional memory onto enabled channels. For easy identification, each channel can be named with up to a ten *Thermocouple Plugs/Probes Sold Separately digit title. In addition, the QuadTemp features individual cold junction compensation for each channel providing increased accuracy and response time, and if a probe is removed or severed during logging, the software automatically annotates the data. The QuadTemp is ideal for a variety of applications, whether it is remote temperature monitoring, or multiple points in a central location. Data from all channels is simultaneously logged. After the monitoring cycle is complete, data can be downloaded for analysis. The QuadTemp comes with a wall mounted universal power adapter. The OctTemp is an eight channel thermocouple data logger with a reading rate of up to 4 Hz. It can measure and record data for up to 500,000 readings per channel. To maximize memory capacity, users can disable unused channels to add additional memory onto enabled channels. For easy identification, each channel can be named with up to a ten digit title. In addition, the OctTemp features individual cold junction compensation for *Thermocouple Plugs/Probes Sold Separately each channel providing increased accuracy and response time, and if a probe is removed or severed during logging, the software automatically annotates the data. The OctTemp is ideal for a variety of applications, whether it is remote temperature monitoring, or multiple points in a central location. The OctTemp comes with a wall mounted universal power adapter. 2

QuadTemp and OctTemp Additional Features and Operation Wiring the Data Logger Wiring Options The QuadTemp has four SMP connections and the OctTemp has eight. These connections allow the user to insert subminiature thermocouple plugs into the connectors on the device. The diagram below shows how to connect the individual thermocouples for each of the devices. Warning: Note the polarity instructions. Do not attach wires to the wrong terminals. Manual Start Click the Custom Start button on the Device panel, or right-click on the device and hover on the start selection, then chose custom start. Apply the options desired and select Start. Once armed through the software, to activate the Manual Start, hold the recessed push button, adjacent to the interface cable plug, down for 10 seconds. To see the change in the status, hit Refresh Devices within the software. Enable/Disable Channels By default, all channels are enabled. 1. In the Connected Devices panel, click the device desired. 2. On the Device Tab, in the Information Group, click Properties. Or, right-click the device and select Properties in the context menu. 3. Toggle the Enable Data Recording options for the thermocouple channels as desired. 4. Apply these changes, there will be a prompt to reset the device, select yes. Note: When the checkmark is empty, the channel is disabled and will not record data or appear in the downloaded datasets. When the checkmark is clearly checked, it will be visible and record data. Thermocouple Type To change the thermocouple type 1. In the Connected Devices panel, click the device desired. 2. On the Device Tab, in the Information Group, click Properties. Or, right-click the device and select Properties in the context menu. 3. On the General Tab, change the Thermocouple type in the drop down menu. 4. Apply these changes, there will be a prompt to reset the device, select yes. Please note that the same thermocouple type must be used on all of the channels. 3

Product User Guide Additional Features and Operation Continued Set Password To password protect the device so that others cannot start, stop or reset the device; 1. In the Connected Devices panel, click the device desired. 2. On the Device Tab, in the Information Group, click Properties. Or, right-click the device and select Properties in the context menu. 3. On the General Tab, click Set Password. 4. Enter and confirm the password in the box that appears, then select OK. Channel Naming Up to a 10-character channel name can be programmed into the data logger for each channel. This ability helps to rename a channel in a report to distinguish it from other similarly named channels. 1. In the Connected Devices panel, click the device desired. 2. On the Device Tab, in the Information Group, click Properties. Or, right-click the device and select Properties in the context menu. 3. In the Channels panel, find the channel desired, then select Use custom name. 4. This will prompt a space to type in a name. 5. Select OK, then there will be a prompt to reset the device, select yes. 4 Still need help? For more troubleshooting tips and information, refer to the built in help section of the MadgeTech 4 software, visit our Knowledge Base online at www.madgetech.com/kbase or contact us for customer support at 603-456-2011.

QuadTemp and OctTemp Product Maintenance Battery Replacement Materials: 3/32 HEX Driver (Allen Key) and Replacement Battery (U9VL-J) - Remove the cover from the device by unscrewing the two screws. - Remove the battery from its compartment and unsnap it from the connector. - Snap the new battery into the terminals and verify it is secure. - Replace the cover taking care not to pinch the wires. Screw the enclosure back together securely. Note: Be sure not to over tighten the screws or strip the threads. Recalibration The QuadTemp or OctTemp standard calibration is one point at 25 C for the internal temperature sensor and 0 mvs for the thermocouple channels. Additional Services: Custom calibration and verification point options available, please call for pricing. Call for custom calibration options to accommodate specific application needs. Prices and specifications subject to change. See MadgeTech s terms and conditions at www.madgetech.com To send devices to MadgeTech for calibration, service or repair, please use the MadgeTech RMA Process by visiting www.madgetech.com, then under the services tab, select RMA Process. RMA Instructions To send a device back in to MadgeTech, follow the instructions below to create an RMA (Return Merchandise Authorization) on the MadgeTech website: 1. Visit www.madgetech.com, under the Services tab select RMA Process. 2. When the web page opens, please sign in. If this is the first time, select Click here to register an account and create one. Once signed in, click on the Make New RMA button and fill in all the blank fields. 3. Complete the applicable fields on the form including customer Billing and Shipping information, even if they are the same. Please see the field explanation below for a more detailed description about questions asked in the Device Information section. 4. When all of the fields are complete, click Generate RMA. 5. Print out the confirmation page that follows containing the RMA number and MadgeTech s address for shipping. A Return Merchandise Authorization must be accompanied by a copy of the RMA paperwork and shipping is prepaid by the customer. The RMA number should be clearly marked on the outside of the package. 6. Please ship the package via UPS, FedEx, TNT, or DHL to the address listed on the confirmation page. USPS will not ship MadgeTech data loggers. 7. A notification email will be automatically sent when MadgeTech has received the RMA. 5

Product User Guide QuadTemp General Specifications 4 Internal Channels Temperature Range Temperature Resolution Calibrated Accuracy -20 ºC to +60 ºC (-4 ºF to +140 ºF) 0.05 ºC (0.09 ºF) ±0.5 ºC (0 ºC to +50 ºC) 4 Remote Channels Remote Channel Thermocouple Types Thermocouple Connection Cold Junction Compensation Maximum Thermocouple Resistance J, K, T, E, R, S, B, N Female subminiature (SMP) Automatic, based on internal channel 1000 Ω, <100 Ω recommended Thermocouple Range (ºC) Resolution Accuracy Start Modes Real Time Recording Memory J -210 to +760 0.1 ºC ±0.5 ºC K -270 to +1370 0.1 ºC ±0.5 ºC T -270 to +400 0.1 ºC ±0.5 ºC E -270 to +980 0.1 ºC ±0.5 ºC R -50 to +1760 0.5 ºC ±2.0 º C S -50 to +1760 0.5 ºC ±2.0 º C B +50 to +1820 0.5 ºC ±2.0 º C N -270 to +1300 0.1 ºC ±0.5 ºC Software programmable immediate start or delay start up to six months in advance May be used with PC to monitor and record data in real time 500,000 readings per channel, channels can be disabled to increase memory Reading Rate Calibration Calibration Date Battery Type 4 readings per second up to 1 every 24 hours Digital calibration through software Automatically recorded within device 9 Volt lithium or alkaline battery included, user replaceable 6

QuadTemp and OctTemp QuadTemp General Specifications Cont. Battery Life 18 months typical Data Format Date and time stamped ºC, ºF, K, ºR, mv, V Time Accuracy ±1 minute/month Computer Interface USB (Interface cable required); 115,200 baud Software XP SP3/Vista/Windows 7/Windows 8 (MadgeTech 4 only) Operating Environment -20 ºC to +60 ºC (-4 ºF to +140 ºF), 0 %RH to 95 %RH non-condensing Dimensions 7.24 in x 2.7 in x 1.02 in (183 mm x 68 mm x 26 mm) Material Black anodized aluminum Weight 15.2 oz (430 g) Approvals CE Battery Warning BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 ºC (176 ºF). Specifications subject to change. See MadgeTech s terms and conditions at www.madgetech.com 7

Product User Guide OctTemp General Specifications 8 Internal Channels Temperature Range Temperature Resolution Calibrated Accuracy -20 ºC to +60 ºC (-4 ºF to +140 ºF) 0.05 ºC (0.09 ºF) ±0.5 ºC (0 ºC to +50 ºC) 8 Remote Channels Remote Channel Thermocouple Types Thermocouple Connection Cold Junction Compensation Maximum Thermocouple Resistance J, K, T, E, R, S, B, N Female subminiature (SMP) Automatic, based on internal channel 1000Ω, <100Ω recommended Thermocouple Range (ºC) Resolution Accuracy Start Modes Real Time Recording Memory J -210 to +760 0.1 ºC ±0.5 ºC K -270 to +1370 0.1 ºC ±0.5 ºC T -270 to +400 0.1 ºC ±0.5 ºC E -270 to +980 0.1 ºC ±0.5 ºC R -50 to +1760 0.5 ºC ±2.0 º C S -50 to +1760 0.5 ºC ±2.0 º C B +50 to +1820 0.5 ºC ±2.0 º C N -270 to +1300 0.1 ºC ±0.5 ºC Software programmable immediate start or delay start up to six months in advance May be used with PC to monitor and record data in real time 500,000 readings per channel, channels can be disabled to increase memory Reading Rate Calibration Calibration Date Battery Type 4 readings per second up to 1 every 24 hours Digital calibration through software Automatically recorded within device 9 Volt lithium or alkaline battery included, user replaceable 8

QuadTemp and OctTemp OctTemp General Specifications Cont. Battery Life 18 months typical Data Format Date and time stamped ºC, ºF, K, ºR, mv, V Time Accuracy ±1 minute/month Computer Interface USB (Interface cable required); 115,200 baud Software Operating Environment Dimensions XP SP3/Vista/Windows 7/Windows 8 (MadgeTech 4 only) -20 ºC to +60 ºC (-4 ºF to +140 ºF), 0 %RH to 95 %RH non-condensing 7.24 in x 2.7 in x 1.26 in (183 mm x 68 mm x 32 mm) Material Black anodized aluminum Weight 17.3 oz (490 g) Approvals CE Battery Warning BATTERY WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 80 ºC (176 ºF). Specifications subject to change. See MadgeTech s terms and conditions at www.madgetech.com 9

Troubleshooting Tips Why is the data logger not appearing in the software? If the QuadTemp or OctTemp doesn t appear in the Connected Devices panel, or an error message is received while using either device, try the following: Check that the IFC200 is properly connected. For more information, see Troubleshooting Interface Cable problems (below). Ensure that the battery is not discharged. For best voltage accuracy, use a voltage meter connected to the battery of the device. If possible, try switching the battery with a new 9V lithium. Ensure that no other MadgeTech software (such as MadgeTech 2) is running in the background. Ensure that the Connected Devices panel is large enough to display devices. This can be verified by positioning the cursor on the edge of the Connected Devices panel until the resize cursor appears, then dragging the edge of the panel to resize it. The screen layout may also be reset in the options menu by selecting File, Options, and scrolling to the bottom. Troubleshooting Interface Cable problems Check that the software properly recognizes the connected IFC200 interface cable. If either data logger is not appearing in the Connected Devices list, it may be that the IFC200 is not properly connected. 1. In the software, click the File button, then click Options. 2. In the Options window, click Communications. 3. The Detected Interfaces box will list all of the available communication interfaces. If the IFC200 is listed here, then the software has correctly recognized and is ready to use it. Check that Windows recognizes the connected IFC200 interface cable. If the software does not recognize the IFC200, there may be a problem with Windows or the USB drivers. 1. In Windows, click Start, right-click Computer and choose Properties or press Windows+Break as a keyboard shortcut. 2. Click Device Manager in the left hand column. 3. Double click Universal Serial Bus Controllers. 4. Look for an entry for Data logger Interface. 5. If the entry is present, and there are no warning messages or icons, then windows has correctly recognized the connected IFC200. 6. If the entry is not present, or has an exclamation point icon next to it, the USB drivers may need to be installed. These are available on the software flash drive included with the IFC200, and on the MadgeTech website. Ensure that the USB end of the IFC200 is securely connected to the computer. 1. Locate the USB-A plug of the IFC200. 2. If the interface cable is connected to the PC, unplug it. Wait ten seconds. 3. Reconnect the cable to the PC. 4. Check to make sure that the red LED is lit, indicating a successful connection. MadgeTech, Inc. 6 Warner Road Warner, NH 03278 Phone 603.456.2011 Fax 603.456.2012 www.madgetech.com info@madgetech.com DOC-1002/1003036-00 REV 4 2014.11.25