Output Voltage* (nom.)(adjustable)

Similar documents
Output Voltage* (nom.)(adjustable)

Industrial Power Supplies

Universal Power Supplies

Enclosed Power Supplies

Industrial Power Supplies

Industrial Power Supplies

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

Industrial Power Supplies

Industrial Power Supplies

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

TEP 100WIR Series, 100 Watt

Universal input VAC <150mW No load power consumption

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

C B. Models. Operating up to 5000m altitude 5 year product warranty

Industrial Power Supplies

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

IEC/EN/UL60950 & CE certified, EN55032 Class B

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

Rhino PSM Power Supplies. Operating Instructions

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Switching Power Supplies

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

TEP 75WI Series, 75 Watt

12-15VDC (12V±5%) 24-28VDC (24V±5%)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Safety Standards. Model Number: Unit Weight:

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Constant Voltage Mode

12-15VDC (12V±5%) 24-28VDC (24V±5%)

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Safety Standards. Model Number:

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Power supply CP-E 48/1.25 Primary switch mode power supply

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Packaging (5) Protection (3) Isolation Voltage (4)

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

Safety Standards. Model Number:

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

PMT. Safety Standards. Model Number:

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

Power supply CP-E 24/0.75 Primary switch mode power supply

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

VP ELECTRONIQUE MASSY - Tel

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

AI561 Analog Input Module

Safety Standards. Model Number:

DI572 Digital Input Module

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Features. Applications and Benefits TRC ELECTRONICS, INC

DI561 Digital Input Module

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

DC562, digital input/output module,

Packaging (4) Isolation Voltage (3) nom. Output Voltage

Gelo LED Driver 100W, Single output RGLD100-24

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Electronic timer CT-AHD.22

Safety Standards. Model Number:

Electronic timer CT-ERD.12

DX561 Digital Input/Output Module

DC561, digital input/output module,

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

60 Watt Medical (MWLT)

Safety Standards. Model Number:

Voltage Current Front-mounting bracket

Power supply CP-D 12/2.1 Primary switch mode power supply

DATASHEET. Ultra Capacitor Charger, UCC-4

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

Transcription:

Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 59,5mm Suitable for mounting in domestic installation panels Low output ripples and spikes Fully compliance to ECO-Standard Suitable for houshold appliance Safety class ll product UL 1310 class II, NEC class 2 compliance UL 508 listed Universal input range 85 to 264 VAC Operating temperature range: 25 C to +70 C max. Adjustable output voltage Short circuit and overload protection DC OK indicator This new DIN-Rail mounting power supplies are designed for industrial and residential applications. They are lower cost than the existing TBL range, with similar electrical specifications. Additionally, they fully comply to the new standby power and efficiency requirements (ECO Standard). They are intended for connecting as class II devices, so the safety earth connection is not required. They are mountable in flat racks due to their small dimensions in depth. Their dimensions comply to the DIN 43 880 standard. CB Scheme UL60950-1 UL508 UL1310 Models Order Code Output Power (max.) Output Voltage* (nom.)(adjustable) Output Current (max.) Efficiency (typ.) TBLC 06-105 6 W 5.0 VDC 1.2 A 74 % TBLC 06-112 6 W 12 VDC 0.5 A 81 % TBLC 06-124 6 W 24 VDC 0.25 A 79 % TBLC 15-105 12 W 5.0 VDC 2.4 A 81 % TBLC 15-112 15 W 12 VDC 1.25 A 85 % TBLC 15-124 15 W 24 VDC 0.63 A 85 % TBLC 25-105 20 W 5.0 VDC 4.0 A 82 % TBLC 25-112 24 W 12 VDC 2.0 A 86 % TBLC 25-124 25 W 24 VDC 1.05 A 87 % TBLC 50-112 48 W 12 VDC 4.0 A 88 % TBLC 50-124 50 W 24 VDC 2.1 A 89 % TBLC 75-112 72 W 12 VDC 6.0 A 89 % TBLC 75-124 75 W 24 VDC 3.1 A 89 % TBLC 90-112 90 W 12 VDC 7.5 A 90 % TBLC 90-124 90 W 24 VDC 3.75 A 90 % http://www.tracopower.com Page 1 of 5

Input Specifications Input voltage nominal ranges 100 240 VAC; 50/60 Hz effective ranges 85 264 VAC; 47-63 Hz (below 100 VAC a derating of 2%/V is required) Input voltage frequency No load power consumption 47 63 Hz 6 50 W models: > 0.3 W 75 90 W models: > 0.5 W Harmonic limits EN 61000-3-2, class A Leakage current Inrush current Output Specifications Output voltage / current 0.25 ma max. 6 50 W models: 15/30 A (115/230 VAC) 75 90 W models: 25/50 A (115/230 VAC) 5 VDC models: 5.0 5.5 VDC* 12 VDC models: 12.0 16.0 VDC* 24 VDC models: 24.0 28.0 VDC* Regulation Input variation 0.3 % max. Load variation (10 90 %) 0.3 % max. Hold-up time 60 ms min. (at 230 VAC) 15 ms typ. (at 115 VAC) Start-up Start up behaviour TBLC 075-112 and 090-112: 0-75 % constant current load other models: 0-100 % constant current load Start up time 1 s max. Ripple and Noise (20MHz bandwidth) Current limit (continuous) Short circuit current Output overvoltage protection 50 mvp-p max. 105 130 % of Iout nom., constant current 70 200 % of Iout nom. (typ.), foldback 150 % of Vout nom. (typ.) DC OK signal trigger threshold ON > 95 % of the set voltage General Specifications Operating temperature Storage temperature Temperature coefficient Cooling Pollution degree 2 Humidity (non condensing) Altitude during operation 25 C to +70 C max. derating above +55ºC : 2.5%/K 40 C to +85 C max. 0.02 %/K convection cooling, no internal fan 5 95 % rel. H max. 4800 m max. Isolation I/O isolation 3000 VAC (4242 VDC) Class of protection safety class II Degree of protection IP 20 (IEC/EN 60529) * Output voltage can be adjusted as indicated. However, output power has to be maintained at nominal value. This means the output nominal current has to be reduced in accordance with the increase of output voltage. All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 5

General Specifications (continued) Safety standards Information technology equipment IEC/EN 60950-1, UL 60950-1 Household applications IEC/EN 60335-1 Safety of machinery EN 60204 Safety for power electronic converter systems IEC/EN 62477 Industrial control equipment UL 508 Class II Power units UL 1310 NEC class 2 UL 1310 (except TBLC 75-112 and 90-112) Electronic equipment for power installation EN 50178 Safety of transformers EN 61558-2-8, EN 61558-2-16 Certification documents (pending) www.tracopower.com/overview/tblc Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 Conducted RI suppression on input EN 55022 class B, Radiated RI suppression EN 55022 class B, Harmonic current emissions IEC 61000-3-2 class A Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 Electrostatic discharge (ESD) IEC/EN 61000-4-2 4 kv/8 kv criteria B Radiated RF field immunity IEC/EN 61000-4-3 10 V/m criteria A Electrical fast transient / burst immunity IEC/EN 61000-4-4 2 kv criteria B Surge immunity IEC/EN 61000-4-5 1 kv/2 kv criteria B Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V criteria A Power frequency field immunity IEC/EN 61000-4-8 30 A/m criteria A Mains voltage dips and interruptions IEC/EN 61000-4-11 0% / 20ms 40% / 200ms 70% / 500ms Environment Vibration acc. IEC 60068-2-6 3 axis, 2g sine sweep, 10 55 Hz, 11 Oct/min Shock acc. IEC 60068-2-27 3 axis, 20g half sine, 11 ms Enclosure material V2 rated plastic Mounting DIN-rail mounting for DIN-rails as per EN 50022-35x15/7.5 (snap-on with self-locking spring) (included) Environmental compliance Reach www.tracopower.com/products/reach-declaration.pdf RoHS RoHS directive 2011/65/EU Connection screw terminal with combi-type screwheads for wire size 0.5 2.5mm 2 http://www.tracopower.com Page 3 of 5

Function Specification Block Diagram Current Limit Characteristic V I nominal I short > 70% Inominal I max < 200% Inominal The load characteristic is designed to accomplish reliable start-up of devices requiring full current at reduced output DC voltage. The maximum current will not exceed 200% of the nominal or 8A, whilst the output power will always be less than 100W for normal and overload operation with nominal output voltages (except TBLC 90-112). Note: All 6W models (TBLC 06-xxx) implement a pulsing power characteristic when in overload or short circuit conditions All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. http://www.tracopower.com Page 4 of 5

Outline Dimensions 59.5 mm Model Width (A) mm Weigth g (oz) TBLC 006 18 60 TBLC 015 27 80 TBLC 025 36 110 TBLC 050 54 180 TBLC 075 72 220 TBLC 090 90 280 45 mm 89.5 mm 43.5 mm 54.5 mm A Wall Mounting Bracket Instead of on a DIN-rail, the modules can also be mounted on a chassis or wall with help of a mounting bracket which is supplied as standard with each power supply Dimensions in [mm], () = Inch Tolerances: ±0.5 mm (±0.02) Wiring Description Wire size Torque AC Input all models: L, N only (2 pin terminal) AWG 20 14 / 0.5 2.5 mm² max. 0.5 Nm DC Output 6 50 W models: single terminal AWG 20 14 / 0.5 2.5 mm² max. 0.5 Nm DC Output 75 90 W models: double terminal AWG 20 14 / 0.5 2.5 mm² max. 0.5 Nm Copyright 2016 Traco Electronic AG Specifications can be changed without notice! www.tracopower.com Rev. March 06. 2017 Page 5 of 5