PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit

Similar documents
PowerFlex DC Stand-Alone Regulator (SAR) Field Circuit Board

PowerFlex DC Stand-Alone Regulator (SAR) Switching Power Supply Circuit Board

PowerFlex DC Stand-Alone Regulator (SAR) Power Interface Circuit Board

PowerFlex 755 Transition Section and Splicing Kit for Floormount Drives and CENTERLINE 2100 Motor Control Centers

PowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement

PowerFlex DC Stand-Alone Regulator (SAR) In-Rush Limiting Resistor

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

PowerMonitor 1000 Unit Catalog Number Upgrade

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

InView Communication Modules

Ferrite Core for Internal DPI Cables on PowerFlex 700S Frame 3 and 4 Drives

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

PowerFlex 750-Series Power Option Cabinets

Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494

Allen-Bradley to-230V Conversion Kit Cat. Nos FC FC075

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

SynchLink Board for PowerFlex 700S Drives with Phase II Control

RGU Main Control Board Replacement Firmware Version 3.01

Embedded EtherNet/IP Option Card for DriveLogix 5730 Controllers

PowerMonitor 5000 USB Driver

Second Encoder Option Card for PowerFlex 700S Drives with Phase II Control

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

Kinetix 6000 Axis Module and Shunt Module

Starter and Circuit Breaker Application with PowerFlex 7000

PowerFlex 400 Drive Firmware Version 7.01

PowerFlex 700H Drive Firmware Revision

PowerFlex 700H AC Drive Safe Torque Off Option

POINT I/O and ArmorPOINT I/O EtherNet/IP Adapters

Kinetix 5500 Servo Drives

PowerFlex 700S and 700H Frame 11 Replacement Power Structures

Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

ControlLogix HART Analog I/O Modules

PHOTOSWITCH Distance Measurement Sensor

Reference Manual. Rockwell Automation Library of Process Objects: Condition Gate Delay (P_Gate) Version 3.5

Quick Start. Logix5000 Control Systems: Connect Kinetix 350 Drives over an EtherNet/IP Network

(Catalog Numbers 1394-FK10TS and -FK22TS)

Removing and Replacing the Line Interface Module Internal Components

Memory Expansion for DriveLogix Controller

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

PowerFlex 700S and 700H Frame 13 Replacement Power Structures

USB-to-DeviceNet Cable

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

Application Technique. Products: Guardmaster 440C-CR30 Configurable Safety Relay, PowerFlex 755 Drive. Safety Rating: CAT. 3, PLe to ISO : 2008

Application Guide. Considerations for 32 Bit Integer Parameters in 16 Bit Processors. PowerFlex 700VC, PowerFlex 700S. Introduction.

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

IntelliCENTER IEC Integration Unit

PowerFlex 700 Power Jumpers

Fork Sensors. Technical Data. Plastic Fork Sensors

DriveTools SP Version 5.06 Software Patch

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

1756 ControlLogix Chassis Specifications

Allen-Bradley 1397 AC Tachometer Interface Card

Application Technique. Products: Guardmaster 440C-CR30 Configurable Safety Relay, PowerFlex 525 AC Drive

20-COMM-E EtherNet/IP Adapter Firmware Revision 4.002

InView Firmware Update

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

You cannot install the module unless the connector is fully extended. ATTENTION: Allen-Bradley HMIs

Rockwell Automation Library of Steam Table Instructions

PowerFlex 700 AC Drive with Vector Control Option, Firmware Revision

DriveTools SP v5.05 Software Patch

Installation Data. The 1771 OB module can control the following output devices: dc motor starters indicators solenoids

Kinetix 2000 Integrated Axis Module and Axis Module

Wiring and Grounding Guidelines for PanelView Plus Terminals

ControlNet Comm Glass Fiber Adapter Kit

Light Arrays. Installation Instructions. Introduction. Catalog Numbers 45MLA-F, 45MLA-CTRL-100F. Original Instructions. Figure 1 - Typical Application

PCI 2 Axis Servo Card

Safety Function: Actuator Subsystems Stop Category 1 via the PowerFlex 525 and PowerFlex 527 Drives with Safe Torque-off

TRC-190 User s Manual

Solar Combiner Enclosure

SensaGuard 18 mm Barrels

Allen-Bradley Parts. Solid State Drive Upgrade Kit. Installation Instructions. About this Product

CompactLogix Power Supplies Specifications

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

PCI 2 Axis Servo Card

ArmorPoint I/O Field Potential Distributor, Series A

Replacing the Power Supply

PowerMonitor 5000 Unit Catalog Number Upgrade

Digital ac/dc (24V) Input Module

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

TRC-190 User s Manual

AB Spares. Installation Data

Zener Barriers Bulletin 937Z

Compact Industrial Non-display Computers

Drive Software Wizards Version 3.10

Replacing or Upgrading DiskOnChip Memory

460 to 230 Volt Conversion Kit for FlexPak 3000 or WebPak 3000 Drives

In this section we tell you how to key your I/O chassis, install your module and make your wiring connections.

Replacement Keyswitch Assembly

Logix5000 Controllers Nonvolatile Memory Card

Installation Data. The 1771 IH module is compatible with the following 2 wire devices: pushbuttons limit switches float switches selector switches

Resolver to Digital Expansion Board

Reference Manual. Rockwell Automation Sequencer Object Version 4.0

Display Solid-state Temperature Switch

In this section we tell you how to key your I/O chassis, install your module and make your wiring connections.

* * Agilent Power Distribution Unit (PDU) Installation Guide

DeviceNet ArmorBlock Network Powered 16-input Module

Transcription:

Installation Instructions PowerFlex 755 Common DC Input Drives, Frames 8...10 Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit Catalog Numbers 20G14x, 21G14x Topic Page General Precautions 1 Before You Begin 1 Install the Retrofit Kit 2 Additional Resources 11 This retrofit kit can be used to improve the access to the molded case switch (SW1) on common DC input drives for lock-out, tag-out procedures. Install this kit only on DC input with precharge modules with catalog numbers 20-750-P5-C770D740 and 20-750-P5-E510F500. General Precautions ATTENTION: Only qualified personnel familiar with adjustable frequency AC drives and associated machinery should plan or implement the installation, start-up and subsequent maintenance of the system. Failure to comply may result in personal injury and/or equipment damage. This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when you install, test, service, or repair this assembly. Component damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, reference Guarding Against Electrostatic Damage, publication 8000-4.5.2 or any other applicable ESD protection handbook. Before You Begin Before you install the retrofit kit, complete these tasks: Review the parts list and verify that you have all items that are listed, page 2 Gather the tools that are required to install the kit, page 2

Kit Parts List This kit contains the following parts. DC precharge left-front cover with access panel DC bus guard Interlock assembly L-bracket and two M5 x 14 mm hexalobular screws Required Tools Tool Description Allen socket wrench ESD-protected place of work ESD-protective clothing Details 2.5 mm Work surface, Floor cover, seat, and ground connections Wrist wrap, shoes, overall clothing (coat) Flash light Hexalobular screw driver/bit #20, #25 Multi-meter Digital multi-meter, capable of AC and DC voltage, continuity, resistance, capacitance measurements, and forward diode bias tests. Fluke model 87 III or equivalent. Nose pliers Phillips screw driver / bit #1 Install the Retrofit Kit Follow theses steps to install the interlock assembly and precharge assembly, left cover retrofit kit. Remove Power from the Drive ATTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged completely before servicing. Measure the DC bus voltage at the -DC and +DC TESTPOINT sockets on the front of the power module (show in the illustration in step 3). Remove power before you remove or make cable connections. When you remove or insert a cable connector with power applied, an electrical arc may occur. An electrical arc may cause these system events, which can cause personal injury or property damage. An erroneous signal to system field devices, which can cause unintended machine motion An explosion in a hazardous environment Electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts can create electrical resistance. 1. Turn off and lock out all input power, including any external power sources (such as an AFE or other DC power source). 2. Wait 15 minutes and verify that there is no voltage at the drive inputpower terminals. 2 Rockwell Automation Publication 750-IN037A-EN-P - June 2015

3. Measure the DC bus voltage at the -DC and +DC TESTPOINT sockets on the front of the power module. Rockwell Automation Publication 750-IN037A-EN-P - June 2015 3

ATTENTION: To avoid an electric shock hazard when servicing the drive, a means for Lockout/Tagout of the external, single-phase 120/240V and, if present, 120V uninterruptible power supply sources must be provided. 4. Turn off and lock the drive circuit breaker SW5 (if used). 5. Turn off the drive disconnect switch SW2. SW2 Frame 9 Common DC Input Drive Shown SW5 4 Rockwell Automation Publication 750-IN037A-EN-P - June 2015

Remove the DC Precharge Left-front Cover and Disconnect Switch Handle and Handle Shaft 1. Remove only the four M5 x 14 mm screws that secure the DC precharge left-front cover to the assembly and remove the cover and top and left guards. 2. Remove the four M5 x 14 mm screws that secure the top and left guards to the cover, and remove the guards. Retain the guards and screws for reuse. = T25 2.8 N m (25 lb in) 2 1 2 3. Remove the two M4 x 12 mm hexalobular screws and washers that secure the rotary disconnect on/off handle to the front cover and remove the handle. Retain the handle, screws, and washers for reuse. 1.8 N m (16 lb in) Rockwell Automation Publication 750-IN037A-EN-P - June 2015 5

4. Loosen the hexagonal screw that secures the disconnect handle shaft to the disconnect switch and remove the handle. 2.5 mm 0.6 N m (5.4 lb in) Install the New Disconnect Switch Interlock Assembly 1. Complete steps a. d to install the interlock assembly on the disconnect handle shaft. a. Position the interlock rod (A) under the clamp assembly (as shown in the illustration). b. Position the set screw (B) to the right of the clamp assembly. c. Position the pins (C) on the disconnect handle shaft vertically and slide the base of the shaft through the square opening in the clamp assembly. C B A 6 Rockwell Automation Publication 750-IN037A-EN-P - June 2015

d. Position the back of the interlock clamp assembly 34 mm (1.33 in.) from the base of the shaft and tighten the M3 x 1.5 mm set screw. P1 1.13 N m (10 lb in) 33.8 mm (1.33 in.) 2. With the interlock rod (D) positioned below the handle shaft, fully insert the handle shaft (E) into the receptacle on the disconnect switch. E D 3. Secure the handle shaft in place by using the set screw on the disconnect switch. See step 4 of Remove the DC Precharge Left-front Cover and Disconnect Switch Handle and Handle Shaft on page 5 for recommended torque. Rockwell Automation Publication 750-IN037A-EN-P - June 2015 7

Replace the DC Bus Guard 1. By using a pliers, remove the four cable tie mounts, which secure the resistor wires, from the back of the existing DC bus guard. 2. Loosen the two M4 x 12 mm hexalobular screws that secure the clear, plastic shield to the front of the DC bus guard and remove the plastic panel. Retain this panel for reuse. 3. Loosen the two M4 x 12 mm hexlobular screws that secure the sheet metal DC bus guard to the resistor assembly and remove and discard the guard. 3 1.8 N m (16 lb in) 2.8 N m (25 lb in) 2 1 4. Place the new sheet metal DC bus guard on the resistor assembly and secure the guard by tightening the two existing screws. 5. Place the clear, plastic shield on the new DC bus guard and secure the shield by tightening the existing screws. 6. Fully insert the four cable tie mounts, which secure the resistor wires, into the holes on the new DC bus guard. 5 2.8 N m (25 lb in) 6 1.8 N m (16 lb in) 4 8 Rockwell Automation Publication 750-IN037A-EN-P - June 2015

Install the Rotary Disconnect Handle and New DC Precharge Cover 1. Secure the existing rotary on/off disconnect handle to the new DC precharge assembly left front cover by using the two M4 x 8 mm long screws and washers. See step 3 of Remove the DC Precharge Left-front Cover and Disconnect Switch Handle and Handle Shaft on page 5 for recommended torque. 2. Secure the two clear plastic guards to the new DC precharge assembly left front cover by using the four existing M5 x 14 mm screws. See step 2 of Remove the DC Precharge Left-front Cover and Disconnect Switch Handle and Handle Shaft on page 5 for recommended torque. 3. Set the rotary on/off handle and the disconnect handle shaft to the off position. The disconnect handle shaft is in the off position when the pins on the end of the shaft are oriented horizontally. 4. Align the rotary disconnect handle and shaft and place the new front cover on the DC precharge unit. 5. Secure the front cover by using the existing screws. See step 2 of Remove the DC Precharge Left-front Cover and Disconnect Switch Handle and Handle Shaft on page 5 for recommended torque. Rockwell Automation Publication 750-IN037A-EN-P - June 2015 9

Install the Interlock Bracket 1. Loosen the two hexalobular screws that secure the circuit-breaker access door to the left front cover and lower the door. 1.8 N m (16 lb in) 1 2. Position the L-bracket with the square opening on top and the screw holes to the front and flush with the back of the cover. IMPORTANT The interlock rod behind the cover must fit into the square opening on the top of the L-bracket (as shown in the illustration). 2 2.8 N m (25 lb in) 10 Rockwell Automation Publication 750-IN037A-EN-P - June 2015

3. Secure the L-bracket by using the two M5 x 14 mm hexalobular screws that are provided in the kit. 4. Close and secure the circuit-breaker access door. 5. Move the disconnect handle to the ON position. 6. Verify that the circuit- breaker access door cannot be opened. 7. Secure the circuit-breaker access door by tightening the two hexalobular screws. Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource PowerFlex 750-Series AC Drives, Frame 8 and Larger Hardware Service Manual, publication 750-TG001 Product Certifications website, http://www.ab.com Description Provides a recommended preventative maintenance schedule, major component test and hardware replacement procedures, and schematic diagrams for frame 8 and larger PowerFlex 750-Series AC drives. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. Rockwell Automation Publication 750-IN037A-EN-P - June 2015 11

Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellautomation.com/support you can find technical and application notes, sample code, and links to software service packs. You can also visit our Support Center at https://rockwellautomation.custhelp.com/ for software updates, support chats and forums, technical information, FAQs, and to sign up for product notification updates. In addition, we offer multiple support programs for installation, configuration, and troubleshooting. For more information, contact your local distributor or Rockwell Automation representative, or visit http://www.rockwellautomation.com/services/online-phone. Installation Assistance If you experience a problem within the first 24 hours of installation, review the information that is contained in this manual. You can contact Customer Support for initial help in getting your product up and running. United States or Canada 1.440.646.3434 Outside United States or Canada Use the Worldwide Locator at http://www.rockwellautomation.com/rockwellautomation/support/overview.page, or contact your local Rockwell Automation representative. New Product Satisfaction Return Rockwell Automation tests all of its products to help ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Outside United States Contact your distributor. You must provide a Customer Support case number (call the phone number above to obtain one) to your distributor to complete the return process. Please contact your local Rockwell Automation representative for the return procedure. Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/. U.S. Allen-Bradley Drives Technical Support - Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, E-mail: support@drives.ra.rockwell.com Online: www.ab.com/support/abdrives. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, PowerFlex, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 750-IN037A-EN-P - June 2015 PN-318377 Copyright 2015 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.