Bagnoli TM 2-Channel Handheld EMG System

Similar documents
TRIGNO TM EMG System. 4-Channel FSR Adapter User s Guide. Copyright Delsys Incorporated

Trigno TM Wireless System User s Guide

Trigno TM Wireless System User s Guide

Trigno TM Wireless Biofeedback System

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

User manual v 1.1. Single channel EMG logger

BSL Hardware Guide for MP35 and MP30-1 -

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

User's Guide. Extech AM A AC Analog Clamp Meter

Model 7705 Control Module

LeCroy PP009 Passive Probe Instruction Manual

Mini Digital Multimeter

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User Guide True RMS Multimeter Extech EX205T

Trigno TM Wireless Biofeedback System

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Model 2657A-LIM-3 LO Interconnect Module

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Technical Note Series

Dual Link DVI Extender

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Mini Digital Multimeter

SPOTTER the multipurpose sensor

CerePlex A. Instructions for Use. 630 Komas Drive Suite 200. Salt Lake City UT USA P F

Mini Digital Multimeter

Mini Digital Multimeter Model MN15. User's Guide

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

2260B-RMK-Series Rack Mount Kit

AC/DC Current Probe Model SL206 USER MANUAL

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

TRIGNO TM Personal Monitor. User s Guide. Trigno TM Personal Monitor User s Guide PM-W02. Copyright 2014 Delsys Incorporated

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

MTS-2000 USER S MANUAL

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Video Borescope Inspection Camera

Drive 3G-S ENGLISH. Cellular Signal Booster A Customer Support: Mon-Fri 8 am to 6 pm.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

User s Guide. 600A AC Clamp Meter. Model 38387

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3

9040/9040UK. Users Manual. Phase Rotation Indicator

EPS Power Supply

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Line Impedance Stabilization Network (LISN)

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

User's Guide. Digital Multimeter. Model MN42

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

Cantata m100 Amplifier

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

DVI ELR Extender over one CAT5

DVI ELR Extender over one CAT5

DS-1H05 Ethernet-over-Coax Extender. User Manual

Tx Link. Quick Setup Guide. English. Connection module

Instruction Manual LeCroy PP007-WR / PP007-WS Passive Probe

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

User's Guide. Model High Precision Quad Output DC Power Supply

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TC100 Precision Thermocouple Calibrator

Conductive Level Controller

AutoRanging Digital MultiMeter

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

AUD-340 Installation Guide

1:4 3GSDI Splitter. User Manual EXT-3GSDI-144. Release A5

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Kramer Electronics, Ltd. USER MANUAL. Model: VP-111. XGA Line Driver

User Manual TL-FO-HD. 4K Optical Fiber Extender. All Rights Reserved. Version: TL-FO-HD_160628

PML 791-RO Low-Z Passive Probe. Instruction Manual

AC/DC Current Probe Model SL201

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Kramer Electronics, Ltd. USER MANUAL. Model: VP-2x2. 2x2 XGA/Audio Matrix Switcher

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

Page 2 262/264 LaserMount User s Manual. Table of Contents

USB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

Always there to help you Register your product and get support at BT6000 Question? BT6050 Contact BT6060 Philips User manual

LeCroy PP008 Passive Probe Instruction Manual

B&W RearView Camera Installation & Operation

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AUD-220 Installation Guide

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Installation, Operation & Maintenance Instructions / Technical Document

Manual. Bluetooth Headphone X9. Please read this manual before operating your headset, and keep it for future reference.

Visit us at

Transcription:

Bagnoli TM 2-Channel Handheld EMG System User s Guide PM-B06 Copyright by Delsys Incorporated Specifications and procedures outlined in this document are subject to change without notice. Delsys Logo, EMGworks, and Myomonitor are Registered Trademarks of Delsys Incorporated. MAN-001-1-4

Table of Contents Table of Contents... 1 Important Information... 3 Intended Use... 3 Contraindications... 3 Technical Service and Support... 3 Warnings and Precautions... 4 Device Information... 5 Disclaimer... 6 Limited Warranty... 6 Bagnoli 2-Channel Handheld EMG System... 7 Bagnoli-2 EMG System Components... 8 Main Amplifier Unit... 8 DE-2.1 Single Differential Surface EMG Sensor... 9 DE-3.1 Double Differential Surface EMG Sensor (Optional) 10 EMG Accessory Kit... 11 Analog Output Package (Option 1)... 11 EMGworks Package (Option 2)... 12 Getting Started with the Bagnoli-2 System... 13 Installing the 9V Battery... 13 Connecting the Analog Output Signals... 13 Installing the USB-6009 and EMGworks... 13 Connecting the Bagnoli-2 to the USB-6009... 14 Connecting the EMG Sensors... 15 Orienting the EMG Sensors on the Skin... 15 Using the Delsys Adhesive Sensor Interface... 16 Connecting the Reference Electrodes... 17 Turning the System On... 17 Selecting Appropriate Amplifier Gains... 18 Beginning Data Acquisition... 18 EMGworks Package... 18 Analog Output Package... 18 Maintenance and Care of the Bagnoli-2 System... 19 Main Amplifier Unit and Input Modules... 19 DE Series Surface EMG Sensors... 20 Specifications... 21 Main Amplifier Unit... 21 BNC Output Cable... 21 1

Output Cable for USB-6009... 21 EMGworks and National Instruments USB-6009... 21 DE-2.1 Single Differential Surface EMG Sensor... 22 DE-3.1 Double Differential Surface EMG Sensor (Optional) 22 Reference Electrode Cable... 22 Component References... 23 2 Bagnoli TM -2 EMG System User s Guide

Important Information Important Information Intended Use The Bagnoli TM 2-Channel EMG System is designed for research, investigational and scholarship purposes only. Delsys products are not intended for measurement purposes or for use in the treatment and diagnosis of humans. Rx ONLY Contraindications DO NOT USE on Patients with implanted electronic devices of any kind, including cardiac pace-makers or similar assistive devices, electronic infusion pumps, and implanted stimulators. DO NOT USE on irritated skin or open wounds. DO NOT USE on Patients with allergies to Silver. Technical Service and Support For information and assistance visit our web site at: www.delsys.com Contact us at: E-mail: support@delsys.com tel: (508) 545 8200 3

Important Information Warnings and Precautions Consult all accompanying documents for precautionary statements and other important information. Consult accompanying user s guide for detailed instructions. Keep the device dry. The presence of liquids may compromise the safety features of the device. Handle with care. Sensitive electronic device. Avoid static discharges. Do not operate or store near strong electrostatic, electromagnetic, magnetic or radioactive fields. Interference from external sources may decrease the signal-tonoise ratio or result in corrupted data. This device may cause electrical disturbances in sensitive equipment within its operating environment. Connect only to Delsys-approved devices. Connecting a patient to high-frequency surgical equipment while using Delsys EMG systems may result in burns at the site of the EMG sensor contacts. Immediately discontinue device use if skin irritation or discomfort occurs. Immediately discontinue device use if a change in the device s performance is noted. Contact Delsys technical support for assistance. Delsys Inc. guarantees the safety, reliability, and performance of the equipment only if assembly, modifications and repairs are carried out by authorized technicians; the electrical installation complies with the appropriate requirements; and the equipment is used in accordance with the instructions for use. 4 Bagnoli TM -2 EMG System User s Guide

Important Information Device Information Complies with Requirements put forth by the Medical Device Directive 93/42/EEC. Class I device, Annex VII. Type BF device (IEC 60601-1). Isolated device, (Class II, IEC 60601-1) Do not dispose this product with house waste. Contact Delsys Inc. for instructions on responsibly disposing this device. This product should not be mixed with other commercial wastes. Date of Manufacturing (appears on device) Serial Number (appears on device) Authorized Representative Manufacturer 5

Important Information Disclaimer DELSYS INC. makes no warranties, express or implied, as to the quality and performance of this product including but not limited to, any implied warranty of applicability for other than research uses by qualified individuals. DELSYS INC. shall not be liable to any person for any medical expenses or any direct or consequential damages resulting from any defect, failure or malfunction, whether a claim for such damages is based upon theory of warranty, contract, tort or otherwise. No representative, agent, or licensed practitioner is authorized to waive this disclaimer. DELSYS INC. makes no diagnosis or prescription by virtue of anything about this product. Limited Warranty The Bagnoli TM 2-Channel EMG Systems are warranted against failure of materials and workmanship for a period of 1 year from the date of delivery, provided that the product is given proper care and has not been subject to abuse during this period. This warranty is in lieu of all other warranties expressed or implied. Operation of this device outside specifications determined by DELSYS INC. or use with any other input devices other than DELSYS INC. sensors constitute an invalidation of this limited warranty. This warranty is not transferable. 6 Bagnoli TM -2 EMG System User s Guide

Bagnoli 2-Channel Handheld EMG System Bagnoli 2-Channel Handheld EMG System The Bagnoli 2-Channel EMG System is designed to make the acquisition of EMG signals hassle-free and reliable. The active sensors are specifically designed to optimally detect EMG signals at the skin surface while rejecting common noise signals such as motion and cable artifacts, yielding an excellent signalto-noise ratio. Gains of 100, 1000 or 10000 can be selected for the ideal acquisition of signals of various amplitudes. The unit is powered from a standard 9-Volt battery and is equipped with a low voltage battery indicator. Each channel output is isolated to 3750 Volts (RMS) and meets medical standards for CE marking and 510K Pre-approval. The integration of all these features in a lightweight portable unit lends the Bagnoli-2 practical in classroom, lab and field environments. Figure 1. Bagnoli 2-Channel EMG System with Analog Output Cable. Figure 2. Bagnoli 2-Channel EMG System with EMGworks Package. 7

Bagnoli-2 EMG System Components Bagnoli-2 EMG System Components Main Amplifier Unit This portable unit supplies power to the EMG Sensors and receives and conditions the signals detected by the EMG Sensors. Each channel has a selectable gain which can be set to a factor of 100, 1000 or 10000. EMG signals are filtered to a bandwidth of 20 to 450 Hz. The 2 analog outputs are supplied to a modular style output connector. Several cables are available to interface with the output connector. The power switch is located on the side of the unit along with an LED indicator that illuminates when the unit is turned on. The belt-clip provides a secure mounting option. Figure 3. Bagnoli-2 Main Amplifier Unit 8 Bagnoli TM -2 EMG System User s Guide

Bagnoli-2 EMG System Components DE-2.1 Single Differential Surface EMG Sensor The DE-2.1 EMG Sensor subtracts EMG potentials detected at two distinct locations on the surface of the skin directly above an active muscle. The EMG potentials are always measured with respect to the electric potential of a neutral site located away from the EMG muscle source. This potential is detected by the Reference Electrode. The sensor is designed using a parallel-bar contact geometry for ensuring signal stability, repeatability between recordings and optimal frequency content representation. This versatile sensor is well-suited for most EMG applications and ideal for both large and small muscles. Figure 4. DE-2.1 Single Differential Surface EMG Sensor. The surface EMG signal is the result of the potential difference between V 1 and V 2 on the skin surface. The sensor housing is constructed from durable polycarbonate and completely sealed. It is also internally shielded to reject ambient electrical noise. The sensor contacts are made from 99.9% pure silver bars measuring 10mm in length, 1mm in diameter and spaced 10mm apart for optimal signal detection and consistency. The curved enclosure geometry is designed to maximize skin contact and adhesion while minimizing the negative effects of sweat during vigorous activities. Figure 5. DE-2.1 EMG Sensor Geometry. 9

Bagnoli-2 EMG System Components DE-3.1 Double Differential Surface EMG Sensor (Optional) The DE-3.1 EMG Sensor is not included in the standard Bagnoli-2 EMG system and must be purchased separately. It is specifically designed to reduce the presence of EMG crosstalk emanating from muscles underneath and adjacent to the muscle of interest. The external dimensions of the sensor are identical to the standard DE-2.1 Sensors. This sensor uses 3 bars instead of 2, however. It works on the principle that a signal originating from a source further away (some other muscle) will arrive at adjacent detection surfaces with less relative latency than a signal which originates from the muscle beneath the sensor. By performing two subtractions, the signals with short relative latency (those originating from distant sources) will cancel out. Visit our web site at www.delsys.com for more information on the use of the DE-3.1 Double Differential Surface EMG Sensors. Figure 6. DE-3.1 Double Differential Surface EMG Sensor. The sensor performs a 2-stage subtraction: the first stage establishes the difference between contact V 1 and contact V 2 as well as between contact V 2 and contact V 3. The second stage then performs a subtraction between these differences. 10 Bagnoli TM -2 EMG System User s Guide

Bagnoli-2 EMG System Components EMG Accessory Kit All Delsys Systems include the essential accessories to get started with hassle-free EMG detection, including: Adhesive EMG Sensor Interfaces Reference Electrodes Reference Electrode Cable Figure 7. EMG Accessory Kit including Adhesive Sensor Interfaces and Reference Electrodes. Analog Output Package (Option 1) The Analog Output Package includes a BNC Output Cable, which connects to the Bagnoli-2 Main Amplifier Unit via a convenient modular plug and jack. The cable terminates into two BNC connectors for reliable connections to an oscilloscope or other data acquisition system. The cable is 25 feet long, which allows for a large usage area. Figure 8. Analog Output Cable terminates in 2 BNC cables. 11

Bagnoli-2 EMG System Components EMGworks Package (Option 2) The EMGworks Package includes all of the components necessary to control data acquisition using a Bagnoli-2 EMG System and EMGworks on a PC or laptop: EMGworks Data Acquisition and Analysis Software National Instruments USB-6009 DAQ Device Bagnoli-2 Output Cable for USB-6009 Figure 9. National Instruments USB-6009 Data Acquisition (DAQ) Device. This device interfaces with a USB port on a PC or laptop to enable data acquisition using EMGworks Software. Figure 10. Bagnoli-2 Output Cable for USB-6009. This cable connects to the Bagnoli-2 Main Amplifier Unit to the NI USB-6009 Data Acquisition (DAQ) Device. The cable is 25 feet long, which allows for a large usage area. 12 Bagnoli TM -2 EMG System User s Guide

Getting Started with the Bagnoli-2 System Getting Started with the Bagnoli-2 System Installing the 9V Battery Open the battery door on the underside of the Bagnoli-2 Main Amplifier and carefully install a 9V battery. Close the door when the battery is secure. Connecting the Analog Output Signals If you are using the Analog Output Cable, the Bagnoli-2 can easily be connected to an oscilloscope or a data acquisition system via the convenient BNC connectors. The input of any device connected to the Bagnoli-2 EMG System with the BNC Output Cable should be appropriately buffered. The output impedance of each Bagnoli-2 channel is approximately 15 K. Installing the USB-6009 and EMGworks The National Instruments (NI) drivers, USB-6009 device, and EMGworks must be installed on the computer that will be used for data acquisition. 1. Insert the Delsys Software CD into the computer and proceed to install the NI drivers. The computer will need to be restarted in order to complete the installation. Note: If the Delsys Software CD is not available to provide the NI drivers, use the National Instruments CDs provided with the USB-6009 or download the drivers from the EMGworks page on the Delsys web site (www.delsys.com). 2. Connect the USB-6009 device to an available USB port on the computer and allow Windows to find and install the necessary drivers. 3. Install EMGworks after the NI drivers and the USB-6009 have installed properly Refer to the EMGworks Installation Guide for detailed installation instructions. Consult the National Instruments documentation provided with the USB-6009 for detailed hardware information. 13

Getting Started with the Bagnoli-2 System Connecting the Bagnoli-2 to the USB-6009 The Output Cable then connects the Main Amplifier Unit to the USB-6009 device. Figure 11. Connecting the Output Cable to the USB-6009. Ensure the Bagnoli-2 Output Cable is connected to the Analog input side of the USB-6009 device. Connecting to the Digital output side of the USB-6009 may cause damage to the Bagnoli-2 Main Amplifier and USB-6009 device. Figure 12. Ensure the Cable is connected to the Analog input side of the USB-6009 device. 14 Bagnoli TM -2 EMG System User s Guide

Getting Started with the Bagnoli-2 System Connecting the EMG Sensors The Bagnoli-2 EMG System is supplied with DE-2.1 Single Differential Surface EMG Sensors. These plug into the receptacles on the Main Amplifier that are labeled with channel numbers. The connectors have a key so that they can only be inserted with a specific orientation. The order of the sensors can be interchanged with no consequences to the performance of the EMG System. The sensor cables are five feet in length so that they can be placed on any part of a user s body when the Main Amplifier is mounted at waist level. Only use sensors that have been approved by Delsys. Connecting unapproved sensors to the Bagnoli-2 System constitutes an invalidation of the Delsys Warranty and may result in personal injury and/or permanent damage to the system or the sensors. Orienting the EMG Sensors on the Skin The DE-2.1 EMG Sensor is fitted with two silver bar contacts for detecting the EMG signal at the skin surface. It is crucial that the orientation of these bars be perpendicular to the muscle fibers for maximum signal detection. The top of the sensor is stamped with an arrow to aid in the determination of this orientation. The arrow should be placed parallel to the muscle fibers underneath the sensor. The sensor should also be placed in the center of the muscle belly away from tendons and the edge of the muscle. The sensor is easily attached to the skin using the Delsys Adhesive Sensor Interface. Muscle Fiber Direction Figure 13. Sensor orientation with respect to the muscle fibers. It is important that the orientation of the arrow on the sensor be parallel to the underlying muscle fibers. 15

Getting Started with the Bagnoli-2 System Using the Delsys Adhesive Sensor Interface The Adhesive Sensor Interfaces use medical-grade adhesive specifically designed for dermatological applications. Usage of the interface promotes a high quality electrical connection between the sensor bars and the skin, minimizing motion artifacts and the ill-effects of line interference. To ensure a strong bond with the skin, it is advised to remove excessive hair and wipe the skin area and the EMG Sensor with isopropyl alcohol to remove oils and surface residues. Allow the skin to dry completely before applying the interfaces. 1) Remove the interface from its strip and apply to the sensors. 2) Remove liner to expose the adhesive. 3) Apply to the skin site. Do not reposition once skin contact is made. Figure 14. Application of the Adhesive Sensor Interface. Adhesive Sensor Interfaces are for single use only. Immediately discontinue use if skin irritation or discomfort occurs. All Adhesive Sensor Interfaces and Reference Electrodes are for single use only. Discard after using. Reseal storage bag to maintain freshness. 16 Bagnoli TM -2 EMG System User s Guide

Getting Started with the Bagnoli-2 System Connecting the Reference Electrodes Connect the Reference Electrode Cable to the Main Amplifier Unit using the banana jack. Apply the Reference Electrode to the skin considering the points below: A high quality electrical connection between the Reference Electrode and the skin is critical for obtaining reliable EMG signals. Be sure to clean and, if necessary, shave the skin prior to affixing the Reference. Only one Reference Electrode is required when collecting EMG signals. The site should be an electrically inactive area on the skin surface. The Sensor Accessory Kit includes disposable disc Reference Electrodes that provide a robust connection and superior conductance. These electrodes are lined with a conductive medical grade adhesive. Conductive electrodes other than the ones supplied may be used as substitutes, but note that performance may vary significantly between manufacturers. Consult the labeling of the supplied Reference Electrodes for details on their proper use. Immediately discontinue use if skin irritation or discomfort occurs. All Adhesive Sensor Interfaces and Reference Electrodes are for single use only. Discard after using. Reseal storage bag to maintain freshness. Turning the System On The power switch is located on the side of the Main Amplifier Unit. The switch is labeled with an I to indicate the on position and with an O to indicate the off position. The switch is purposefully recessed to minimize its obtrusiveness and the possibility for accidental power off during EMG acquisition. The LED located next to the power switch illuminates when a charged battery is correctly installed and the unit is in use. This LED will flash when the battery needs to be replaced. Never use an AC adapter to substitute power for the 9-volt battery. This will negate the safety features of the system and may place the user at risk. 17

Getting Started with the Bagnoli-2 System Selecting Appropriate Amplifier Gains There are two slide-switches located on the Main Amplifier Unit, each controlling the gain of a channel. Gains can be set to one of the following options: 100: This position sets the channel gain to 100. Gains of 100 should be used when recording abnormally large EMG signal amplitudes. Surface potentials ranging from 10 mv to 50 mv will result in output signal voltages of 1 to 5 Volts. Using this gain on EMG signals lower than 10 mv will result in recorded signals of poor resolution. 1k: This position sets the channel gain to 1000. This is the nominal gain for typical surface EMG signals ranging from 100μV to 5 mv, resulting in output voltage signals of 100mV to 5 Volts. This setting provides the ideal resolution when sampling with 16-bit A/D acquisition systems. 10k: This position sets the channel gain to 10000. This extremely sensitive gain should only be selected when attempting to record particularly faint EMG signals, in the range of 100 V to 500 V. The output yielded in this case is 1 V to 5 V, but the resolution is not optimized. Beginning Data Acquisition EMGworks Package Data acquisition with the USB-6009 is controlled by EMGworks Acquisition. Refer to the EMGworks User s Guide for detailed data acquisition instructions. Analog Output Package Data acquisition with the BNC Package requires an oscilloscope or other data acquisition system. Consult the documentation for the oscilloscope or data acquisition system being used for instructions. 18 Bagnoli TM -2 EMG System User s Guide

Maintenance and Care of the Bagnoli-2 System Maintenance and Care of the Bagnoli-2 System Main Amplifier Unit and Input Modules The Bagnoli-2 System is designed to provide years of reliable service when proper care is followed. A one-time calibration is performed at the time of manufacturing. No further calibration is needed. While the Main Amplifier Unit case is made of durable plastic, the following points should be kept in mind when using and handling the Bagnoli-2 EMG system: The device and its accessories should be visually inspected before every use to ensure that no mechanical deterioration has occurred. The Bagnoli-2 Main Amplifier Unit can be easily cleaned with a damp cloth and mild detergent. The unit is not shockproof and should not be dropped or be subjected to excessive forces or accelerations. Provide ample strain relief for the interconnecting cables so that none of them are under excessive tension. Do not pull on any of the interconnecting cables. Remove the 9V battery from the Main Amplifier Unit if the device will not be used for an extended period of time. Only use sensors that have been approved by Delsys. Connecting unapproved sensors to the Bagnoli-2 System constitutes an invalidation of the Delsys Warranty and may result in personal injury and/or permanent damage to the system or the sensors. The Main Unit and the Input Modules are not waterresistant. Under no circumstance should the units be exposed to water or any other type of liquids. Caution: The risk of electric shock exists if the Main Unit is operated while in contact with liquids. 19

Maintenance and Care of the Bagnoli-2 System DE Series Surface EMG Sensors The DE Series Surface EMG Sensors are encased in a sealed polycarbonate case. The following points should be kept in mind when handling the sensors. All sensors should be visually inspected before each use to ensure that no mechanical deterioration has occurred The sensors can be cleaned and sterilized with a damp cloth and mild detergent, with isopropyl alcohol swabs, or with a 70% isopropyl alcohol solution. It is crucial that the sensor contacts remain clean at all times. The sensors are completely sealed and are water-resistant. These can be used on damp skin surfaces and in the presence of sweat without compromise to safety, sensor integrity or operation. The sensors should never be completely submerged in any liquid. The sensors contacts are made of pure silver and are quite soft. Care should be taken to preserve the integrity of these contacts. Do not scrape or dent these contacts. Do not pull on the sensor cable. Avoid kinks in the cable, as these will result in damage to the internal cable wires and intermittent connections. Handle the sensors with care: do not drop them on the ground or step on them. The sensors must only be used with Delsys EMG Systems. The DE-2.1 and the DE-3.1 EMG Sensors are specifically designed for the Bagnoli series EMG Systems. Using these sensors as inputs to any other EMG system constitutes an invalidation of the Delsys Warranty and may result in personal injury and/or permanent damage to the sensors or the system. Do not submerge the sensors in any liquid under any circumstance. The sensors contain sensitive electronic circuitry. Static discharges and intense magnetic fields should be avoided to prevent possible irreparable damage to the sensors. 20 Bagnoli TM -2 EMG System User s Guide

Specifications Specifications Main Amplifier Unit Number of Channels 2 Analog EMG Overall Amplification per Channel 100, 1000, 10000 Max. Output Voltage Range ± 5 Volts Channel Frequency Response 20±5 Hz to 450±50 Hz, 80 db/decade EMG Sensors DE-2.1 (single differential) or DE-3.1 (double differential) System Noise (R.T.I.) <1.2 μv(rms) for the specified bandwidth Power Requirements 9 VDC, 10mA (quiescent) Channel Output Isolation 3750 V(rms) @ 60 Hz for 60 sec. Operating Temperature 15 C to 40 C Case Dimensions 114 mm x 71 mm x 33 mm Weight 0.2 kg BNC Output Cable Output Connector Male BNC (2) Length 7.62 m Cable Shielded, 4-Conductor flat Output Cable for USB-6009 Output Connector Length Cable USB DAQ connector, 16 position 7.62 m Shielded, 4-Conductor flat EMGworks and National Instruments USB-6009 Sampling Rate 48 ks/s Aggregate Resolution 14 bit PC Interface USB 2.0 21

Specifications DE-2.1 Single Differential Surface EMG Sensor Output Connector Length Cable Sensor Contacts Contact Spacing Sensor Dimensions Preamplification CMRR Power Cable Length Number of Conductors Case Material USB DAQ connector, 16 position 7.62 m Shielded, 4-Conductor flat 2 silver bars 10 mm x 1 mm diameter 10 mm 19.8 mm x 5.4 x 35 mm 10 V/V 92 db (typical) 84 db (minimum) ± 18 mw (quiescent) 1.67 m 4 (shielded) Polycarbonate plastic DE-3.1 Double Differential Surface EMG Sensor (Optional) Sensor Contacts Contact Spacing Sensor Dimensions Preamplification CMRR Power Cable Length Number of Conductors Case Material 3 silver bars 10 mm x 1 mm diameter 10 mm double differential configuration 19.8 mm x 5.4 x 35 mm 10 V/V (per differentiator) 92 db (typical) 84 db (minimum) ± 41 mw (quiescent) 1.67 m 4 (shielded) Polycarbonate plastic Reference Electrode Cable Connector Banana & 2mm Tip plug Conductor Single Length 1.67m 22 Bagnoli TM -2 EMG System User s Guide

Component References Component References Part Description Bagnoli-2 EMG System with Analog Output Package Bagnoli-2 EMG System with EMGworks Package Bagnoli-2 Main Amplifier Unit DE 2.1 EMG Sensor DE 3.1 EMG Sensor Bagnoli-2 BNC Output Cable, 25ft Bagnoli-2 USB DAQ Output Cable, 25ft DAQ Module for USB (NI USB-6009) EMG Accessory Kit Adhesive Sensor Interfaces DE 2.1 DE 3.1 Reference Electrode Cable 9V Battery Carrying Case Bagnoli-2 EMG System User s Guide EMGworks Signal Acquisition and Analysis Software Part Number DS-B01 DS-B05 SP-B02 SP-E04 or SP-E09 SP-E06 or SP-E11 DC-T03 DC-T06 SC-A10 SC-K05 SC-F01 SC-F02 DC-R02 SC-T01 SC-C07 PM-B06 SC-S04 * N.B. Medical Device regulations prohibit the individual resale of the components listed above. These can only be obtained through the purchase of a complete Bagnoli-2 System since the Intended Use, the Safety and the Performance of these components can only be guaranteed when they are connected and used in accordance with the Bagnoli-2 Design Specifications. 23

Component References 24 Bagnoli TM -2 EMG System User s Guide